ML23047A295

From kanterella
Jump to navigation Jump to search

Conversation Record - Clarification Call with TVA Regarding Its 080422 Exemption Request for Sequoyah Nuclear Plant Independent Spent Fuel Storage Installation
ML23047A295
Person / Time
Site: Sequoyah  
Issue date: 02/08/2023
From: Tilda Liu
Storage and Transportation Licensing Branch
To: Cupp B, Mcneil A
Tennessee Valley Authority
References
EPID L-2022-LLE-0027
Download: ML23047A295 (2)


Text

(12-2020)

NRC FORM 699 U.S. NUCLEAR REGULATORY COMMISSION CONVERSATION RECORD Page 1 of 2 NRC Form 699 (12-2020)

NAME OF PERSON(S)/TITLE CONTACTED OR IN CONTACT WITH YOU Brian Cupp, Andrew McNeil, TVA Licensing, et. al.

(see below)

DATE OF CONTACT 02/08/2023 E-MAIL ADDRESS MS Teams Call Link Sent by NRC TELEPHONE NUMBER Teams Call TYPE OF CONVERSATION E-MAIL TELEPHONE

INCOMING OUTGOING

ORGANIZATION Tennessee Valley Authority (TVA), Sequoyah Nuclear Plant DOCKET NUMBER(S) 07200034 LICENSE NAME AND NUMBER(S)

Sequoyah Nuclear Plant Independent Spent Fuel Storage Installation; Docket Nos: 50-327, 50-328, and 72-034 MAIL CONTROL NUMBER(S)

EPID No: L-2022-LLE-0027 SUBJECT Clarification call with TVA regarding its August 4, 2022 exemption request (ADAMS Accession No. ML22216A078) for Sequoyah Nuclear Plant (SQN) Independent Spent Fuel Storage Installation (ISFSI)

SUMMARY

AND ACTION REQUIRED (IF ANY)

SUBJECT Exemption request for deviating from various 10 CFR 72 non-destructive examination compliance requirements related to Sequoyah Nuclear Plant (SQN) ISFSI dated August 4, 2022

SUMMARY

On February 8, 2023, the NRC staff held a call with TVA representatives to discuss certain portions of TVA's November 18, 2022 (ML22318A147) response to the staff's December 19, 2022 (ML22353A066) request for supplemental information (RSI) pertaining to SQN's August 4, 2022 (ML22216A078) exemption request. See continuation page. No NRC staff decision, neither technical nor regulatory in nature, was made at the call.

As a result of the discussion, the staff indicated that it plans to provide followup questions via email to support additional clarity in order to allow TVA/SQN to respond in writing. TVA personnel expressed that it agreed with the staff's proposed plan. TVA/SQN was given an opportunity to review and comment on this summary.

PARTICIPANTS NRC/NMSS: Omar Khan, Juan Lopez, Darrell Dunn, Sujit Samaddar,Tilda Liu TVA/SQN: Brian Cupp, Andrew McNeil, William Whitener Holtec (contractor/vendor to TVA/SQN): Chuck Bullard, Kyle Trotter, Anveshan Bommareddi, Vaughn Curcio, Robert Tindal NAME OF PERSON DOCUMENTING CONVERSATION Tilda Liu, NMSS/DFM/STLB Add 1 Continuation Page Delete 1 Continuation Page SIGNATURE AND DATE Tilda Y. Liu Digitally signed by Tilda Y. Liu Date: 2023.02.15 16:46:28 -05'00'

CONVERSATION RECORD (continued)

NRC FORM 699 (12-2020)

U.S. NUCLEAR REGULATORY COMMISSION Page 2 of 2 NRC Form 699 (12-2020)

LICENSE NAME AND NUMBER(S)

Sequoyah Nuclear Plant Independent Spent Fuel Storage Installation; Docket Nos: 50-327, 50-328, and 72-034 MAIL CONTROL NUMBER(S)

EPID No: L-2022-LLE-0027

SUMMARY

AND ACTION REQUIRED (IF ANY) (Continued)

Staff Follow-up to TVA's Response to RSI Related to August 4, 2022, Sequoyah ISFSI Exemption Request*

DRAFT Material Discipline

1. Confirm whether 100% of all repairs were performed from the outside diameter of the multipurpose canister (MPC). [RSI-M1, RSI-M2]
2. Repair 1 -- specify the location of the lack of fusion (LOF) (i.e., root/back-weld, root face, or sidewall of the weld joint). [RSI-M1]
3. Repair 2 -- specify the location of the LOF (i.e., root/back-weld, root face, or sidewall of the weld joint).

[RSI-M2]

Note: As the second iteration of radiographic testing (RT) identified 0.327 inches of LOF within the view of 0-1 for weld no. 21, located approximately 4 to 14 inches from the bottom of the MPC baseplate, explain and/or justify how the defect removal via excavation caused the repair area extend into the adjacent view 1-2, which is approximately 8.5 to 25 inches from the bottom of the baseplate for the total length of the excavation shown in Figure 5 as 16.5 inches.

4. Specify the location of the 7.5 inches section with the missing RT. [RSI-M1, RSI-M2]

Structural Discipline The staff noted that the RSI response did not include sufficient information in demonstrating how the local membrane plus primary bending stress remains acceptable after considering the reduction factor established for the exemption request. [RSI-S3]

Note: Section 1.5 of Holtec RRTI-3087-007, Revision 2, evaluates only the primary membrane stress for the shell and does not address the local membrane plus primary bending stress and its resulting safety factor. The staff notes that Section 1.5.2 in analysis No. HI 2094418, Revision 20, Structural Calculation Package for HISTORM FW System," evaluates both the primary membrane stress AND the local membrane plus primary bending stress for the shell.

EPID No.: L-2022-LLE-0027 Docket No.72-034

1032, Amendment No. 3 (ML17214A039), Appendix B, Section 3.3, "Codes and Standards." By letter dated November 18, 2022 (ML22318A147), the NRC staff provided a request for supplemental information (RSI) to TVA as part of the acceptance review process. By letter dated December 19, 2022 (ML22353A066), TVA provided its response to NRC's RSI.

Add 2nd Continuation Page Delete 2nd Continuation Page