Chris Speer 50.72 Rulemaking Update

Status

  • Federal Register Notice (FRN) posted - available for comments
  • NRC Staff recommend rulemaking to remove 6 criteria and update the guidance for 2 criteria

Reporting Requirements Summary Table

  • 11 Total Reports
  • 6 Reports recommended for removal
  • 1 Addition - MAP-X 10 CFR 50.72 Paragraph Condition Requiring NotificationRecommendation (b)(1)

Deviation from TS under 10 CFR 50.54(x)

No change (b)(2)(i)

Plant shutdown required by TS No change (b)(2)(iv)(A)

System actuation (ECCS discharge)

Eliminate (b)(2)(iv)(B)

System actuation (RPS actuation) No change (b)(2)(xi)

News release or notifications of other government agency Eliminate (b)(3)(ii)(A)

Degraded condition Update NUREG 1022 (b)(3)(ii)(B)

Unanalyzed condition Update NUREG 1022 (b)(3)(iv)

System actuation (valid or invalid actuation)

Eliminate (b)(3)(v)

Event or condition that could have prevented fulfillment of a safety function Eliminate (b)(3)(xii)

Transport of a contaminated person offsite Eliminate (b)(3)(xiii)

Loss of EP capabilities Eliminate (a)(1)

Alternative Reporting Method (MAP-X)

New

Path Forward

  • Public Meeting - Early December
  • Communicate regulatory process forward
  • Describe recommendations and their bases
  • Describe process for submitting comments
  • Answer questions from public
  • Consider comments during next steps of the rulemaking

Future Proposed rule to the Commission: May 2024 Proposed rule to the Commission: May 2024

  • Public meeting(s)
  • Public comment period after Commission approval Final rule to the Commission: February 2026 Final rule to the Commission: February 2026 These are estimated dates.

These are estimated dates.