ML22286A046

From kanterella
Jump to navigation Jump to search

Application for the Model No. F-522 Transport Package - Supplemental Information Needed
ML22286A046
Person / Time
Site: 07103091
Issue date: 10/31/2022
From: Garcia-Santos N
Storage and Transportation Licensing Branch
To: Boyle R
US Dept of Transportation, Office of Hazardous Materials Safety
Garcia-Santos N
Shared Package
ML22286A046 List:
References
A33010, EPID L-2022-DOT-0004
Download: ML22286A046 (5)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Richard W. Boyle, Chief Sciences Branch Division of Engineering and Research Office of Hazardous Materials Safety U.S. Department of Transportation 1200 New Jersey Ave., S.E.

Washington, D.C. 20590

SUBJECT:

APPLICATION FOR THE MODEL NO. F-522 TRANSPORT PACKAGE -

SUPPLEMENTAL INFORMATION NEEDED

Dear Richard Boyle:

By letter dated May 16, 2022 (Agencywide Documents Access and Management System Accession No. ML22160A421), as supplemented on June 8 (ML22160A424), and August 3, 2022 (ML22160230), the U.S. Department of Transportation requested that the U.S. Nuclear Regulatory Commission (NRC) staff performs a review of the Canadian Approval Certificate Number CDN/2094/B(U)-96, Revision 4, Model No. F-522 transport package, and make a recommendation concerning the revalidation of the package for import and export use.

The NRC staff performed an acceptance review of your application to determine whether the application contains sufficient technical information in scope and depth to allow the NRC staff to complete a detailed technical review per the International Atomic Energy Agency Specific Safety Requirements No. 6, Regulations for the Safe Transport of Radioactive Material, 2012 Edition.

This letter is to advise you that based on our acceptance review, the application does not contain sufficient technical information. The information needed to continue our review is described in the enclosure to this letter as request for supplemental information.

In order to start our technical review and keep this high priority case on schedule, this information should be provided within 3 weeks from the date of this letter. If the NRC receives acceptable responses in a timely manner, you should expect to receive a request for additional information in December 2022, approximately.

October 31, 2022

R. Boyle If you wish to discuss these issues in more detail prior to submitting your response, the staff is available for a public meeting. Please reference Docket No. 71-3091 and EPID L-2022-DOT-0004 in future correspondence related to this action.

If you have any questions regarding these matters, please contact me at 301-415-6999 or ngs@nrc.gov.

Sincerely, Norma Garcia Santos, Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-3091 EPID L-2022-DOT-0004

Enclosure:

Request for Supplemental Information Signed by Garcia Santos, Norma on 10/31/22

Enclosure Request for Supplemental Information U.S. Department of Transportation Canadian Approval Certificate Number CDN/2094/B(U)-96 Revision No. 4 Docket No. 71-3091 Model No. F-522 Package REQUEST FOR SUPPLEMENTAL INFORMATION Materials Evaluation RSI-Ma-1 Provide the drawings for the F-522/F-528 package configuration.

Drawings listed in Appendix A, Drawing and Document List for the F-522 Transport Package, do not appear to be included in the submittal.

This information is necessary to demonstrate compliance with the requirements in paragraphs 220, 640, and 809(b) of the IAEA SSR-6, 2012 Edition.

Structural Evaluation RSI-St-1 Provide the drop test results for the F-522/F-528 package configuration.

Section 3 of Appendix 19, Justification of the F-522/F-528 Package Configuration, states the following:

significant difference [20% more mass than the mass of the UK-201 shielding vessel with contents] will be assessed with a full scale drop test in accordance with a plan approved by the CNSC.

However, the descriptions and results of the full scale drop test were not included in Addendum A19.4, F-522/F-528 Drop Test Results (IS/TR 2690 F522), of the application to demonstrate that the package and its content (including the top plug/screws) remained intact and leaktight. This section of the SAR was added as a place holder, but never was updated with the test results.

This information is necessary to demonstrate compliance with the requirements in paragraphs 719, 722 and 727 of the IAEA SSR-6, 2012 Edition.

RSI-St-2 Provide the tie-down test results for the F-522/F-528 package configuration.

Section 3 of Appendix 11.4, Tie-Down Testing, states that similar performance is expected from the F-522/F-528 configuration. This will be demonstrated with a full scale test with an applied load of at least 1,219 kg. However, the full scale tie-down test was not included in the application. It was noted that the tie-down test report is missing from Appendix 11.4.2 of the IS/TR 2650 F522 Report. This

2 section was added to the SAR as a place holder, but never was updated with the test results or an analysis to demonstrate that the tie-down points are designed to withstand the total load without yield.

This information is necessary to demonstrate compliance with the requirements in paragraph 638 of the IAEA SSR-6, 2012 Edition.

RSI-St-3 Provide the testing analysis including the evaluations and results performed for the F-522 with the F-528 shielding vessel.

Section 2.5 of IS/TR 2650 F522 states that Retesting is planned with the F-522/F-528 prototype and a load of 1219 kg per aperture. The results will be provided in Appendix 11. Similarly, it also states that another specimen for the F-522/F-528 was subjected to the two 1-m pin drops and a 9-m drop, and that the F-522/F-528 was drop tested with the 12 lbs//ft3 FR-3712 foam. However, Appendix 11 does not include the testing analysis including the evaluations and results performed for the F-522 with the F-528 shielding vessel.

This information is necessary to demonstrate compliance with the requirements in paragraphs 719, 722 and 727 of the IAEA SSR-6, 2012 Edition.

ML22286A046; ML22286A046 OFFICE NMSS/DFM/STLB NRR/DEX/EMIB NRR/DEX/ESEB NMSS/DFM/STLB NAME NGarcia JHuang JLopez SFigueroa DATE Oct 13, 2022 Oct 13, 2022 Oct 13, 2022 Oct 13, 2022 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/MSB NMSS/DFM/STLB NAME NGarcia NGarcia TBoyce YDiaz-Sanabria DATE Oct 17, 2022 Oct 18, 2022 Oct 18, 2022 Oct 31, 2022 OFFICE NMSS/DFM/STLB NAME NGarcia DATE Oct 31, 2022