Certificate of Compliance No. 1014 Appendix D Proposed Amendment No. 16A 2-11 Approved Contents 2.0 Table 2.1-4 BURNUP AND COOLING TIME FUEL QUALIFICATION FOR MPC-32M Region No.Cell Decay Heat Load Limit (kW)
(see Figure 2.1-1Notes 1, 2, 3)
Polynomial Coefficients, see Paragraph 2.II.1.5.2 A
B C
D 1 (Inner) 0.83 6.57083E-14
-4.02593E-09 1.47107E-04 8.01647E-01 2 (Outer)0.83 < decay heat 1.25 1.25 < decay heat 1.46 1.46 < decay heat 1.81 1.81 < decay heat 3.26 5.58795e-154.11020E-14 1.21147E-14 3.82652E-15 3.76103E-16
-5.13598e 4.62813E-09
-1.08013E-09
-2.38729E-10 4.83486E-11 5.81723e-052.17444E-04 8.66361E-05 4.75134E-05 1.74805E-05 4.09393e 5.55545E-01 4.04455E-01 6.36443E-01 6.53455E-01 The burnup and cooling time for every fuel loaded into the MPC-32M must satisfy the following equation:
- where,
= 3 + 2 + +
Ct
= Minimum cooling time (years),
Bu
= Assembly-average burnup (MWd/mtU),
A, B, C, D
= Polynomial coefficients listed in Table 2.1-4 Notes:
- 1. Decay heat per fuel assembly is presented A decay heat value that is equal to or greater than the appropriate decay heat load limit 2.1. The polynomial coefficients associated for decay heat load 1.81 < decay heat 3.26 are applied to the UNVENTILATED OVERPACK MPC-32M decay heat load range of 0.83 < decay heat 3.26 Holtec Letter 5014951 Attachment 6 Page 1 of 2