Email from NRC to Duke - Additional Feedback for RAI B2.1.7-4a
ML22192A067
Person / Time
Issue date: 07/06/2022
From: Mary Johnson
NRC/NRR/DNRL/NLRP
To: Gambrell R, Guill P
Duke Energy
Shared Package
ML22192A062 List:
References
Download: ML22192A067 (1)


Text

From:

Johnson, Marieliz To:

Gambrell, Reene; Guill, Paul F Cc:

Wu, Angela

Subject:

RAI B2.1.7-4a Date:

Wednesday, July 06, 2022 10:27:08 AM Hi Paul, Reene, welcome back J

As Jim was finalizing his SE he noticed that AMR item 3.1.1-118 is related to RAI B2.1.7-4a, and that because of the information that is going to be submitted on the RAI response the AMR item might need to be updated to be consistent. The AMR item was last updated on the RAI Response Set 2 Letter dated February 14th, 2022 (ADAMS Accession No. ML22045A020).

a) For the amended SLRA Table 3.1.2-2 AMR item on Core Barrel Cylinder, subitem on Cracking as linked to the Reactor Vessel Internals Program on page 7 of Enclosure 1, 4 in the February 14, 2022 letter, please check whether that subitem should be amended to align to: (1) NUREG-2191 Item IV.B4.R-423, (2) NUREG-2192 Table 1 Item 3.1.1-118, and (3) NEI Note B.

b) For the current status of SLRA Table 3.1.1, Item 3.1.1-118 (where the current status is either Not Used or Not Applicable), please check whether Item 3.1.1-118 now needs to be amended to be consistent with GALL-SLR/SRP-SLR.

Feel free to contact me if any questions