ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: PALISADES NUCLEAR PLANT Date of Examination: 2/13 - 2/20 2017 Examination Level: RO SRO-I SRO-U Operating Test Number: __________
Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System / JPM Title Type Code*
Safety Function
- a. Synch Main Generator D,S 4S
- b. Respond to Safety Injection Tank high pressure N,S 3
- c. Respond to Control Room Outside Air Intake Radiation Monitor Alarms N,S 9
- d. Shift 4160VAC Busses from Startup Power to Station Power N,S 6
- e. Open MSIVs after Reactor is Critical A,D,L,S 4P
- f. Primary Coolant System Inventory Control A,EN,M,S 1
- g. Containment Air Cooler Service Water Leak N,S 5
- h. Hot Leg Injection Using P-66B and Split Flow A,L,M,S 2
In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
- i. Respond to Radiation Monitor RIA-1810 Low Sample Flow Rate N,R 8
- j. Purge the Main Generator to Raise Hydrogen Purity N
4S
- k. Isolate B SG from Outside the Control Room A,E,M 3
All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1 1 / 1 / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1
ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: PALISADES NUCLEAR PLANT Date of Examination: 2/13 - 2/20 2017 Examination Level: RO SRO-I SRO-U Operating Test Number: __________
Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System / JPM Title Type Code*
Safety Function
- a. Synch Main Generator D,S 4S
- b. Respond to Safety Injection Tank high pressure N,S 3
- c. N/A N/A N/A
- d. Shift 4160VAC Busses from Startup Power to Station Power N,S 6
- e. Open MSIVs after Reactor is Critical A,D,L,S 4P
- f. Primary Coolant System Inventory Control A,EN,M,S 1
- g. Containment Air Cooler Service Water Leak N,S 5
- h. Hot Leg Injection Using P-66B and Split Flow A,L,M,S 2
In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
- i. Respond to Radiation Monitor RIA-1810 Low Sample Flow Rate N,R 8
- j. Purge the Main Generator to Raise Hydrogen Purity N
4S
- k. Isolate B SG from Outside the Control Room A,E,M 3
All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO / SRO-I / SRO-U A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1 1 / 1 / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1
ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: PALISADES NUCLEAR PLANT Date of Examination: 2/13 - 2/20 2017 Examination Level: RO SRO-I SRO-U Operating Test Number: __________
Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System / JPM Title Type Code*
Safety Function
- f. Primary Coolant System Inventory Control A,EN,M,S 1
- g. Containment Air Cooler Service Water Leak N,S 5
- h. Hot Leg Injection Using P-66B and Split Flow A,L,M,S 2
In-Plant Systems* (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
- i. Respond to Radiation Monitor RIA-1810 Low Sample Flow Rate N,R 8
- k. Isolate B SG from Outside the Control Room A,E,M 3
All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO / SRO-I / SRO-U A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1 1 / 1 / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1