05000250/LER-2021-004, Cancelation of LER 2021-004, Through-Wall Leakage from Core Exit Thermocouple Tubing

From kanterella
(Redirected from ML22087A079)
Jump to navigation Jump to search
Cancelation of LER 2021-004, Through-Wall Leakage from Core Exit Thermocouple Tubing
ML22087A079
Person / Time
Site: Turkey Point NextEra Energy icon.png
Issue date: 03/28/2022
From: Pearce M
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2022-047, LER 2021-004-00
Download: ML22087A079 (1)


LER-2021-004, Cancelation of LER 2021-004, Through-Wall Leakage from Core Exit Thermocouple Tubing
Event date:
Report date:
2502021004R00 - NRC Website

text

10 CFR 50.73 L-2022-047 March 28, 2022

U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001

RE: Turkey Point Unit 3 Docket No. 50-250 Reportable Event: 2021-004-00 ( Cancelation)

Date of Event: November 12, 2021 Title: Cancelation of LER 2021-004, Through-Wall Leakage from Core Exit Thermocouple Tubing

On 11/12/2021 Licensee Event Report 05000250/2021-004-00 was submitted pursuant to 10 CFR 50.73 (a)(2)(ii)(A), due to evidence of RCS pressure boundary through-wall leakage on a Core Exit Thermocouple (CET) tube.

Subsequent analysis performed by an independent laboratory found that there was no RCS Pressure Boundary through-wall leakage and that the observed leakage likely originated from a threaded compression fitting on a tubing joint. On 3/10/2022 FPL Engineering concluded that the observed condition was not an ASME Section XI through-wall flaw and is therefore not reportable. The original NRCOC notification, EN 55574, has been retracted. This letter serves to cancel LER 2021-004-00.

If there are any questions, please call Mr. Robert Hess at 305-246-4112 or e-mail Robert.Hess@fpl.com.

Sincerely,

~~

Michael Pearce Site Vice President - Turkey Point Nuclear Plant Florida Power & Light Company

Attachments: None

cc: USNRC Senior Resident Inspector, Turkey Point Plant USNRC Regional Administrator, Region II

Florida P owe r & Light Comp an y

9760 SW 344th St., Hom es t ea d, FL 33035