AUX. SALTWATER PUMP 2-1 SUCTION BAY 2
33
<KY AUX. SALTWATER PUMP 2-2 SUCTION BAY 248A-E 33 LS 164 31B 32B 33B UNIT I AUX. SALTWATER PUMPS s
~
)
IA 2-I AUXILIARY SALTWATER PUMPS DC-663030- I 24" X20" NOTE
( TYP. )
14 IT]
200 55 GI -687-24 NOTE 6 NOTE I
@HIA 5
FCV-496
~
s 185A/B GI G2 YX 484 4"
-D V 2"
S/C:
DWG:
NOTE 4 EMBEDDED R-0183 3/4"-316 (UNIT I l
~ Gl-933-24 57
- 3 S8-3/4 AUXILIARY~ l------....:....::--=----=-------1-t++--iXJ-----'
SALTWATER dTI INTERTIE NOTE 19 NOTE 14 GI -676-24 C E s
IT]
201 t--------i~l----'--'----------'--------9----,
54 GI -680-24 NOTE I
++-----------+--)
@HIA NOTE 6 2 -2
~-
34B MECH.
< 196-E I 35)1
?
' I 4
CIVIL 438093&94 G2-6159-24 NOTE 35B MECH.
G 2 G I I 7 ----t-----.
NOTE 16
~
C NOTE 2 36B 37B 38B 39B V
V r,
r, E-3405-2 E-3406-2 w 57.2 57.2 I
NOTE 3 NOTE 20 V
(21s1311,s, 1 w~ru1 (TYP) 57-E 14 2" I GI -4 2"
f----1 >4.______.IT]_c "--------'G'--'-l _-....:.7--=I -=-3--2=-4--------+-----=-E M--=B::...:E::...:D:...:D:...:E:...:D _____..,__----,-_J__.. TO OCEAN NOTE 18 95-3710 31B 60 I 1930-92 ljJ MECH.
CIVIL MECH.
438093&94 NOTE 2--+-~
( 198-E I 35)1 G2-6158-24 TW 485 I
G2 GI GI -687-24 NOTE S/C: 95-2800
( TYP. 2 PLCS. l Pl NOTE 7 2-1
( 162-AI 34)
NOTE 3 H~Kf----.----,
J--3/4-i)f----.---l><HNOTE 3 57.2 D & LX L!.J LJ-m TC
--- S/C:
L!.J 1/4"
( TYP.
TC fcl
- 57. 2
[If LJ D & LX COMPONENT COOLING WATER HEAT EXCHANGERS DC-663212-41&42 V
V r,
r, ill_
lIJ E-3403-2 E-3404-2 57.2 57.2
__ill_ill lIJ NOTE 3 NOTE 20 (TYP)
VI 5 7-D 14 94-4736 2 PLCS. l S2-518-2 UNIT I S2-4000-2 6 9 -E I 9 r=-=----___:_.::....:....--=-_..---,
LIQUID WASTE FILTERS S2-519-2 NOTE 15 E-1445-4
~---r=--~
56B-A 16 MAKE-UP WTR. SYS.
Vr.i S2-2 NOTE 5 S2-3068-6 32 GI -3681 -6
~
32 S2-2 NOTE 15
)
Gl-3682-6 NOTE 32 2,, It-+! +----'--il---1 6-r-+-I f----.JL__--+~-----,~
f---lDl~*>4R**---=-G...:...I _-...:...7...:...1 4...:...--=-2=-4'--..,_ __
+----1....::C...1.._---=.E--=M=-B =-E D=-D=-E::..:D=---____..,_ __
...1.._r-l TO OCEAN NOTE 18 FCV-503 NOTE GI -680 -24 8 95-3710 6011930-92 30B S/C: 95-2800 -
(TYP. 2 PLCS.)
2-2 8
Pl NOTE 7 AUXILIARY SALTWATER SYSTEM ljJ NO T E 3 H:Xf----.----,
NOTES:
Qffi CWP 2-I SUCTION BAY C E SCREENED VENT C E NOTE 9 C2 E(TYP.)
C2 E 3NPGIC 3 size 4"
3" NOTE I I
( TYP. )
3 "
4" C2-5198-4
~1-:::::-1NOTE I 2 3"
NOTE 10
( TYP. l C2 E C E GI -680-24 s- -(35B-c>-m--------~
I~
3" 4"
3" 3 "
4" C2-5199-4 3"
C2 E C E
~1-:::::-1NOTE I 2 GI -687-24 5----(35B~) TIJ- - - - - - -- ~
ASW-VACUUM RELIEF VALVES I~
SCREENED VENT 3"
SEE CIVIL DWG 438094 SUMP
---3/4-(33 A -B) 0 I 2020 ZNS4 FXC2 N/ A NOT REQUIRED PER CF3. I D5 DATE DWN RE IV PROFESSIONAL ENGINEER PE DISC.
232
.1. f--- -- S/C: 94-4736 1
- PORTIONS OF LINES Gl-680-24 AND Gl-687-24 IN THE INVERT AREA ARE INSULATED WITH I THICK ARMSTRONG ARMAFLEX II", AND PORTIONS OF LINES G2-6158-24 & G2-6159-24 ARE COATED WITH L!.J L!.J
( TYP. 2 PLCS. l 5 7. 2
____W TC STACKWRAP COATING IN THE INVERT AREA.
SEE DWG. 425852.(r-3~3B--A--)(33B-C)
D & LX LJ lIJ TCtE-57.2 E LJ D & LX
- 2.
11/2" CONTROMATICS BALL VALVE WITH 4" FLANGE. SEE NOTES: CONT I NUA TI ON
- 15.
VALVES REFERRED TO THIS NOTE FALL UNDER SPEC.0722(38B-B/C)
( 39B-B)
- 16.
24" DIELECTRIC 15ou INSULATION KIT <STOCK CODE u95-05231 EXCEPT EXISTING FLANGE GASKET RETAINED (35B-A)(35B-C)
I 7.
- 18.
- 19.
- 20.
PIPE SB/B-675 STOCK CODE u95-0171, FLANGE SB/B-462 STOCK CODE *95-0 I 70 ( 35B-A) ( 35B-C)
FE-500 AND FE-501 ARE ULTRASONIC FLOWMETERS THAT HAVE BEEN STRAPPED ONTO THE OUTSIDE OF THE ASW PIPES. (34B-A) (34B-C)
GARLOCK STYLE 204HP, S/C 95-2341, SEE DC-663323-24.(32B-B)
Tl-186 & Tl-187 CAN BE REMOVED TEMPORARILY & RTD'S CAN BE INSTALLED FOR TESTING. (37B-A) (37B-C)
Revised Per DFT-7*5069 PE EXP.
DWG. 6006473-216 OR SW-2-864 ( 3SB-A)(35B-C)
DWG. 6011930-70 FOR SW-2-865
- 3.
USE PIPE SPECIFICATION "Ml" (36B-A/C) 4, ALL S.S. %" AUTOMATIC AIR VENT ARMSTRONG NO, I I -AV OR APPROVED EQUAL ( 33B-B)
- 5.
VALVES WITH ITEM NUMBERS FALL UNDER SPEC. 8729, UNLESS REFERRED TO NOTE 15.(39B-B) 6, 24" C&S CHECK VALVE, SEE DC-6006473-160 (32B-AX32B-C)
- 7.
FOR PROVISIONS FOR LONG TERM COOLING WATER SEE DWGS.
107031 AND DC-663212-1 I & 38 ( 36B-CX 36B-B)
- 8.
GARLOCK STYLE 204 HP, S/C 94-5753 (35B-CX37B-CX37B-AX35B-A)
<SEE DC-663323-141
- 9.
SPECE PIPE THREADS INTO A STAINLESS STEEL FLANGE, WHICH IS CONSIDERED PART OF THE SEISMIC SUPPORT AT THE VACUUM BREAKER INLET(31B-D)
- 10.
FOR 3"-150* FLANGED ENDS ALUMINUM BRONZE SWING CHECK VALVE WI TH VACUUM BREAKER SEE DC-663313-47 AND DC-663313-57. ( 31B-D)
I I, FOR 3"-150* FLANGED ENDS ALUMINUM BRONZE FLEX WEDGE GATE VALVE WITH 10" DIA. HANDWHEEL SEE DC-663313-48(30B-D) 12, FLAT FACE FLANGES ON LINES 5198 & 5199 TO HAVE RUBBER GASKETS ONLY.( 30B-E)
- 13.
ALL PIPES ON THIS SHEET ARE PG&E CLASS C" UNLESS OTHERWISE NOTED
- 14.
REFER TO PG&E DRAWING 053094 SH.6 FOR DETAILS ON INSULATING CDIELECTRICI FLANGE ASSEMBLY INSTALLATION AT THESE LOCATIONS
-NOTES CONTINUED AT LEFT-LJ NIT 2 DIABLO CANYON POWER PLANT - PG&E CO, SALTWATER SYSTEM DRAWING SHEET PAGE REV 080 7 3B 0 84 A