ML21305A532
Text
I 88Sl£e col-JTA/1.JMENT I ISOLATION PHASE Al op EN SA p ----.----------
e l
sBao tNDIC,._TION CONTACT FOR MON I TOI? LI G /IT BTHIIO 3'/J CI cs/NEor-ornv H
_l 8880 CNAC,r B T CS/OPEN t
'f..P/15877 C
POSB77
~
XP¢S877
£3 f;2
-t m
411*/
!<605 0
~
- z
<:)
RNS¢8 A9~
,;f
,11-2
- g -,;
El j
KP¢SB7,{
~
POS878 ci or OPEN
> ~
XPPSB18 1 ~
PMIB4-c<
SV.357 8880
~ N l = i N
CNAC.
PM 184-NI G,
R E5 L
BTHIIO TD ERFVS ir MUX03-IZ.-2 LT CNAC K r~--c, 3(.
31'.
XP(;S878J 'I-P~S877 POS87,S POS877 Al~
A
""""((oSr XP~S878 NI XP"ijS8T7 88B0 ACCUM Nz 5UPPLY HDR CIRCUIT NQ RSI JIB OTHER 5.1.S. VALVE, S\\MIL"-1'. AS SHOWN ~ELOW, USE DETAIL "i' CONTROL,WITCH FOR. "-LL VALVES VALVE o.e,,
VALVE SOLENOID 50L-.VALVE CIRCUIT NOf\\MAL ENG.SF GD. VALVE POSITION SW.(POS.)
LOl.OF
~
6 CONTACT P05IT\\ONS f\\EMARl<.5 CLOSE OPEN CLOSE NEUT. OPEN m
C>-jf-o A
X 5/'AR.G C>-jf--0 8
)(
THIS 01'/G.
o-lJ-<> C X
X rn,s owe,..
0-11---0 D X
X SPII IZE J)fTAIL'A" CONTROL 5lJITCH 8~~0 ) W, W, 8~~
3 U5EO AT LOCATIONS CIH,C,
OIR.
SPRING RETUl'N TO NEUTl'.AL FROM OPEN
- CLOSE OPEN CONTACT POS lrlONS RE.MARKS CLOSE OP~t..l C>-jf-0 I A
)(.
T~ IS owe..
o-H-c I e
)(
SPl>-RE
(§J DE TA I L B" CONTROL SWITCH 8
~~sA USEO AT Lo,AnON5 UIAC C.t-lR NO SPf\\lNG RETURN,
SAFETY lf.JJElTION SIG~l I SOLATION 5\\GN~L P~A>t /\\ PENN.
NO-DESC.RIPTION tKT. NO, LOC. NO-VALVE NO. LQC, NO.
NO.
POSITION fUNC TION CLOSED OPEl\\l CONT~OL DEVICE LO C..
CONTACT DEVICE LOC.
CONTACT NO.
ERFDS 8880 ACCUM '12 SUP?L'( f!DR.
3I7D
)(8880 357 PM\\84-RS! 118 CI.OSEO T
B1l 878 CNAC -- -- ---
K60; eNspe, 11-1.11'-bll*l Piu,03-12-2.
8871 1/CCI/M TEST IS{}L (/1/CQ#TIIJ!IMCNT, 317D X887!
224 £:,. PM/27 RSI/38 CLOSED T
874-87.3 CNIIC -- -- ---
KflOS Rf/SOIi ',/0-5-#-(,IIJ-I, 12£ MUX03*I2*I 89&/
1/t.C.IJM Tt5 T I'SOL fOilTCO!fTI/INM[N 215D
~ 355 PMIM I/SJ/50 UOSED T
890
/l89 QM(. -- -- ---
KG05 RN5/J8 10-)">f'(,!0*4 --
MUX02*23*/
8883 SIIFETY INJECfltJN T[5T LINE 21.5 I)
X8/38!J
~GO PM l84 l?SI/9/ aosw T
883 884-
£./iK -- --
--- xr,os IINS!)8 ~/0-S,IN,IO*, --
MUXOZ-23-Z SA t.!L_
(J!j..C t_ _
_ O_pic._t:i_ ___ ---J.
IN_D ICATIO"-.
£:,. Al>~EP 17IOl>E AT OJAC P --,-0--o-Pl--.s:<<= - --
C A J_ 8875A Or,s/OPEN L 1 CNAC a
CNM 1
3G 3R
.()
f""
~= r.,,
2
T)( 2E
~
BTX 2E 1
3G 3R 5
PM48
'"" J """'
0 ci u:.
> w SV331 o£ POS 828 pos 82 7 887511 A
OPrN A
CLOSE SA~ QIN.
IHlltE N --L......{CJ!-o/~/,/~ NI Ni NI
~TG2E PM4-8
)(P¢S828 l{P¢SSZ7 8875A ACCUMULATOR TANK 11 VENT CIRCUIT NO. RSI0O1 OTHER S.[.S. VALV.S 51"1\\Ll>.R AS S~OWN IN TABLE.
USE OETl>-IL "B" COIJT"-O L SWITCH FOR ALL VALV~S
- VALVE D.C.
VAi.VE SOL.VAL\\I: SOL,V/>-1.VE VAi.VE POSITION SW.(P05\\
LOC. OF CIRCUIT PENN.
NO, DESCRIPTION CKT, NO, LOG.NO.
\\110.
LOC No.
CLOSED OPE!-l CONT!sOL No.
NO.
ERFDS 8675A ACtUM. TANK 1l VE.NT 2-41!)
)(B875A 332
! ~
B2.7 82.B illM 1'(51001 it MUX04<1I aBl&A I ACrnM. TANK t1 DMll\\l XB\\37/oA I 333
, PM 29 82'l 830__
~
! 004-2.E.
I
~-*--
- - - --,f---
-+---4 I
~
~
RHR HX. I !NJ. TEST v ** REAC.5Wi 24ID
)<.886"-A 33/o l l<Sl'.'_33~ __ 835 63'.
C,J[.\\
f(5l013 II E
! BBBSA I I 1 I I I HX. I X8685A 337 XSV337, 831 B:>.8 CNR 01&
IIE 8\\364B I I 2 I I I /i'EAC. I XB864B. 338 _ ~Tg:iq-- 840 _ -
-+---f CNR***-_
0Iq II E.
8885B t
1'* 21 I
I HX.
I X888SB !
3~q
.PM122 l
~84I 842 CNR 022 IIE
~l8A.
ACCUM.TANKllSU PPLY
)<.8818A 1.340 PM29 843 844 CNAC - --
02.S H
--- ~
81315B.
AC.CUM,TANKli -v {~'.
\\(8875B 341 PMI25 845.J'~"'- _______
C_!'!_AC
_ __ Q2.8_
1.E MUX04-f1-2 887&B AtC.UM. TANK 12. DRAIIJ JC.887(,B 342 PM lo&
, 847 848 Ct-lAC 031 2.e *
( TAt,Li! CONTINtJEO)
VALVE DESC!c/PT/ON D. C.
VALVE:
.SOL.VALV.f 12l!.VALVE NO.
CKT Na. LOC. Na, NO. ~-
NO.
I 882.!>
COLO LE(; LOOPS 1 TEST 2410 I>'><<<?*
PM/22 138Z.4 HOT,Eci, i.OOPS 1-4 nr:sr YRA?,L 369 PM/22 B82S RHR TO HOT LE<,5 /-f. TE~T
~
35'0 PMG7 l
~
~ =---t-*-...,,____,,
~
8884C HOT Li!!C,, LOOP.S
'f:l!!ST YSOgdC.
391 PMl:>2 8884D f/OT LEG LOOP4-TE.ST
~
394 ~
681813 ACCUM. TAIJI<. 12 SUPPLY 24ID
)(./3871313 345 PMlo&
' 6S3 854 CNAC 1'(51040 2E I
~ -
8815C Ac,uM,TANKl'.IVENT -+1--..:_,~, 34*
_f'__M4_6_+
~5_5 -f-8%_+--+---~A_C __ --* 043
\\IE MUXO'l-17-3 8871,t ' At,uM-TANK 13 DRAIN xss1,c 347 PM'9 851 858 CtcAC.
j 04&
\\IE V
"v
'v I
-v i-- - -+-----------+----+-- --+-- - -+--- -+---+---~--+' ---+--
- -. -* t----+---,t J...
8878C A"UM, TANK 13 SUPFLY 24\\D
)(8B18C.
350 PM b9 -
B ~
864 lli_M.
f(51055 2E 887S0 I ACCUM, TANK 14 VENT 1~8S15D 351
~
- _8*"-~-,~a....
I tNAC 1
058 1.E MJJX04*N 881/oO ACC.UM, fAWK 14 Df\\A\\N I
t
\\l.861&D.
35'2.
, f'Mll 8b1 9;,5
, C.NA.I, OE>/
2.E
~
7
~
1
~
---~ --*
.A
.A.
~
.A 1-c~~-+--~-----=--+-~~-+-~ --~! _ ____L
--'---+-----,f----<
66780 1>-"UM. fANK 14 'lUP?LY 24ID
)(86180 35Co I PMlO 875 87Co
' CNAC 11'(51073 U:
I I
l J
i
( T413i.t=
CONTINlJliD ON.SIOE)
CONTACTS POSITIONS REMA/?K5
~~! OPEN
---fl--
A X
GREEN L1511r
---ft-B X
SPARE
---ff--
C X
SPARE
---ft-0 X
SEENoT£ VALVE OPEN POSITION SWITCH NOTE* SEAL [lo/ FOR Pos 873,878, 889, 884 SPARE Fo,, Ail OTHER POSs CONTACTS POSITIONS REMARKS CLOSE ?[fti~
--II-A X
RED LIGHT
--ii-B X
SPARE
- C X
5EE Nor1,
-<I-D X
SPARE VALVE CLOS£ POSITION 5_WJTCH NOTE. MONITOR L,: FoR POS 874,817 8(H, 890. SPARE FoR/UI.OTNl'li RlSs VALVE POSIT/ONSW. (PoS,) lOC. Or C/,f!r;LI/ T PtSNN.
CLOSED OPEN C()NT'RaL NO, Na, 130&
8/0 s;1/E.
RSZ/60 ZE.
BIZ B/4 rlJO J?SI/65' z E.
816 8/7 Y:1.E RSI/ ?O ZE 891 8~4
('.A//;>
R...Z/7S ei.:
900
'102
.Q::iE RSI/80 21:.
~
)
TABLE OF DEVICES FUNCTION SOLENOID VALVE SB ___ I Fl.OW COIJTROL VALVE PO, ___, ~ALVE POS ITION !;WITCH K~OS tD !-lTAINMENT ISOLATION PHA5E II l>.v'< *
- RELAY RATING EQUIP~_ENT LOCATION NUMBERS CNR- -
COtJTf\\01. 60"-RD RE5\\0UAL HEAT MFR.
I TYPE CNAC -
CO~TROL F.>01>-RO ACCUMULATOR 5Ef\\VICE RNS~A NUCI.EAI', SAFEGUi>,P.D OUTPUT RI.CK
/1, GA.T, /
owe..tJo.
(i'.l)
PMC.4 -
MECH. PANH NO, 64 AGCUMMULATOR TAIJK HA l<>TG2C.E- -
TE"-MIIJAL BOX G
1.bE BTHl/0---TERMINAL BOX H
110 xeaao - - - FLOW COIJTROL VALVE BBBO REFERENCE DRAWINGS I 0 REMARl"-5 S*E TA6LE FOR VALVE
,EE TAe.LI; FOR. SWIT'I
- 1.
l:~UIPt{IEt-lT LOC/1,TION NUMioERS ----------- DWG,NO. I0Iqoo
- 2.
DE.5CRIPT\\ON OF ELECT, 5CHEMl>,T\\C D\\A,GRAM 5YMl:IOL~ ANO CIRCUIT DESIC.N ------------DWGo.N0.050003
- 3.
PIPING Sct-lE'MATIC-SA.FETY INJEGTIOl\\l SYSTEM----- DWG., NO. I02.ooq 4
- lN5TRUMENT SCMcMATlt-fcOW llll*TRUMEN'T SYSTEM--- DW(,, NO, \\O'l.031.
- s.
G.
7,
- 8.
- 9.
\\0.
SIIJ~I.E L\\WE 1/\\E'l:Efl.
~ f\\E'-"-'<
12sv.o.c. SYSHM,~H.I
DWC..N0-43.754b CIRCUIT SCHrDlJLE -
NUCLE'AR CONTROL -
DWG-NO. 103072 DELETED
@ FUNCTION D/ At; RA r,,1=,
@ SOLID STAH. ;>ROff.Cf\\O N SY!;.r~M SCHEMATIC DIAGRAM MONITOR 1.-IGHT eox 8, c II BLOCK DIAG. ERFDS TECH. SUPPORT CENTE.R 8, CONTROL ROOM RE.C. ['io.
l?e:c. No.
DWG. N9*
DWC,. NO.
pW,;.
NO.
- 501809,
'=ib:,I')$
60~2.e.\\
437G97, f 445278 4417077 503088 It,
',JN6lE LINEMETE/<. t, l'-EIAr,m PC '>Y~TEM, 1\\*H
- 13.
$ CHEM DIAG SSPS OUTPUT RELAYS, TRAIN A, TRAIN 8 ___
0WG VALVE Nos.:
,8880, 8875A, 881~/',~
88841', 1 8BB*
~
8S18C, 88 150, 887~D,
- 8B7SD, 8684B, 088513, \\387SA, 6S75B, 887',\\3,
. 8818130 8815',
~
8"1>",B871,8%1ytl82~,68Z4,6'S?&,8884C, 58e4D, A
)___
NUC LEAR SAFETY RELATED KE Y DWG.
SEC T I ON_4_
UN I T I B
C P. G. &E. SY PHASE SEQU A-C-B DATE 10 2010 0. 0.
MNRU R.E.
FxC2 I. v.
I & C SCHEMA T ! C O ! AGRAM SAFETY IN JECTION SYSTEM SOLENOID VALVES 01A8LO CANYQ:,.J POWER PLANT PAC IF IC GAS AND ELECTRIC COMPANY SAN FRANCISCO,
CAL I FORNI A 4 3R7W5N8 8 I SHE'° I POE