ML21305A478

From kanterella
Jump to navigation Jump to search
6 to Updated Final Safety Analysis Report, Figure 3.2-17, Sheet 5 of 18, Drawing 102017-5, Saltwater Systems
ML21305A478
Person / Time
Site: Diablo Canyon  
Issue date: 10/11/2021
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21306A142 List: ... further results
References
DCL-21-074
Download: ML21305A478 (1)


Text

E D

C B

en 0

N I

0 I

'SI" C

o 01 "IJ

~~t U1 'f.\\'=;

I 0

r--

I 'SI"

-UlVl 0,z Nr--N o-..

-OL 11 N

Q) er:: 0

(/)

w-=i I-II l/lZO

<.(C)<.(

cr::ou 50 DOMESTIC WATER REF DWG 4001982 35-B UNIT I

AUXILIARY SALTWATER BAY CHLORINE INJECTION 35- ---t UNIT I

AUXILIARY SALTWATER BAY CHLORINE INJECTION NOTE 7 (TYP, 4) 51 f NOTE 25 NOTE 24 NOTE 11 BACKFLOW PREVENTER NOTE 26 NOTE 24 FILL LINE 52 3/4.

NOTE 23

( TYP OF 2 l CARBON FILTER I "

ION EXCHANGER NOTE 28 ri 0-1501 NOTES 17 8, 27 0-1495 0-1496 r*--------------------------------------7 L..J j

J..,

AUXILIARY SALTWATER CONT I NUOUS D

CHLORINATION FEED PUMPS

~

Al

~

~

0-1499 53 54 55 WATER PURGE TANK 250 GALLONS 1----------'-----'----~-*-]IE NOTE 24 S -3/4 "

3/4 X1/2 _B------,---1 R-0109 1445 TYGON HOSE L..J L.JTO FLOOR DRAIN S - 7 I O 7 -1/2 59A -E NOTE 28 0-1502

.----------li----...t-J F L O A T _____._

VALVE NOTE 10 R-0109 FILLxf-__ 4-_E_-6_16_6_-_2,---__ ___,_,---~

LINE NOTE 17

_....f------lXIF I LL NOTES I 7 & 27 LINE 1221 0-1494 0-1493 SODIUM I

Al I 0-1497 L.J D BROMIDE~:

TANK 0-1 --

T. C.

r-1111 1220 1214 E-6163-2 T. C.

r7 R-0109 (El")

'-'Ii 2 I 5 56 NOTE 13 E-6162-2 DC-6014454-3 NOTE 15 1213 HASTELOY-C CAP~ I A I

  • ~

c::::::::::::::

HYPOCHLORITE PUMP SYSTEM CONTAINMENT TANK VENT(IB SEAWATER CHLORINATION TANK 0-1 (HYPOCHLORITEl DC-6014454-1 NOTE 15 1226 NOTE 14 NOTE 14 L..J D 1216 1217 T. C.

r7 1219 E-6164-2 1230 1232 1231 2X3/4 E-2 E-2 1229

~

r,

~

1303 NOTE 18

( TYP 4 l

& I X1/2

( TYP 4)

E-6167-2 L..J D NOTE 19 (TYP 4)

CHLORINE ROOM FILL LINE 1243 NOTE 17 VENT V

r7 SEAWATER CHLORINATION TANK 0-2 zt/)

I 155 00

~

~

(HYPOCHLORITEl DC-6014454-1 NOTE 15

~

E-6164-2 1225 1241 NOTE 20 (TYP 4)

NOTE

( TYP 35

-B er::

35 31

-c

-B 17 er::

57 31

-B 17 NOTE 6 f----- ::,<'.'.

UV)

NOTE 5 0

0

( I 080 I 7)

I-I-

35-B UNIT 2 AUXILIARY SALTWATER BAY CHLORINE INJECTION 35-D V

( TYP.

r7 V

r7

24)

WQ_

7

~

I 153 z=:J o~,

~

UNIT 2 AUXILIARY SALTWATER BAY CHLORINE INJECTION L----------------------------------------

1 TO INTAKE F-705-4 II STRUCTURE (.J.3."..::4!!._<B~(--------,~----1 V..,

G-0627 9 5 -E I 8 >--------l FIRE PROTECTION SYSTEM F-709-4 FCV-493 NOTE L..J D

>---]

~

14 ETD 1/2X:%

E-21/2 G-0 I 17 E-1306-21/2 E-6115-3/4 G-0285 L..J D

CHLORINATION SYSTEM

~

lj 3NPGIC 3 size DC-663026-22 04-I 0-20 I 9 ZNS4 FXC2 N/ A NOT REQUIRED PER CF3. I D5 DATE OWN RE IV PROFESSIONAL ENGINEER PE DISC.

u u

UNIT 2 w

w er::

er::

oZ enZ 0

0 en :::::

co :::::

I-I-

'SI" er::

'SI" er::

u u

'w

'w w

w

>u

>u u <.(

u <.(

oZ enZ LL Cl.

LL Cl.

en :::::

co :::::

V)

V)

'SI" er::

'SI" er::

'w

'w LL LL

>u

>u 0

0 u <.(

u <.(

LL Cl.

LL Cl.

Cl.

Cl.

V)

V)

LL LL 0

0 Cl.

Cl.

Revised Per DFT-7*4856 PE EXP.

58 59 NOTES:

I. ALL PIPING IN THIS SHEET ARE PG&E CODE CLASS "E

2. DELETED
3. DELETED
4. DELETED
5. ** 1/2" OD HASTELOY C TUBING, 0.035 WALL THICKNESS, AND HASTELOY SWAGELOK FITTINGS
6. 1/2" WHITEY HASTELOY BALL VALVE WITH SWAGELOK END CONNECTIONS, MODEL # HC-63TS8-T <18)
7. 1/2" NUPRO HASTELOY SPRING LOADED CHECK VALVE WITH 10 PSIG CRACKING PRESSURE AND SWAGELOK END CONNECTIONS, MODEL# HC-BC-TR-10 ~
8. DELETED
9. DELETED
10. FLOAT VALVE l"XI" BRASS ROBERTS P/N R400 OR EQUIVALENT~
11.

BACKFLOW PREVENTER 3/4" WATTS REGULATOR P/N 3/4"X 3/4" 2-2 OR EQUIVALENT (ABANDONED) ~

12.

I" SS BALL VALVE, WHITEY 651Sl6 OR EQUIVALENT~

13, 2" PVC CHECK VALVE PASTOMATIC CKMIOOV OR EQUIVALENT~

14. DRAIN VALVE PROVIDED BY TANK VENDOR~
15. TANK AND CONTAINMENT BULKHEAD FITTING ARE THREADED CONNECTIONS AS PROVIDED BY MANUFACTURER. CONNECTION BETWEEN TANK AND CONTAINMENT IS FLEXIBLE PVC~

I 6. DELETED

17. SECONDARY CONTAINMENT FOR FILL LINES PROVIDED BY 4 E-SPEC PIPING 18, TRUE UNION TYPE I THREADED BALL VALVES,WITH VITON ELASTOMERS

( OR EQUIVALENT l ~

19. 1/2" HASTELOY C TUBING,.035" WALL~
20. NUPRO "C" SERIES CHECK VALVE WITH1/2" SWAGELOK END CONNECTIONS, 10# CRACKING PRESS. <HC-8C-IO OR EQUIVALENT)~
21. WHITEY SERIES "60" BALL VALVE WITH1/2" SWAGELOK END CONNECTIONS (HC-63TS8, OR EQUIVALENT)~
22.,. DENOTES EQUIPMENT SUPPL I ED BY OTHERS
23. 3/4" FLEXHOSE SYNFLEX 3130-12 STOCK CODE 17-2193 W/ 3/4" NPT FLEXHOSE COUPLINGS ( STOCK CODE I 7-2 I 85 OR EQUIV. ) (52/53-E)
24. BALL VALVE 3/4" SPEC R-0388 (STOCK CODE 72-9968 OR EQUIV. l~
25. TUBE AND FITTINGS IAW "S" SPEC, UNLESS OTHERWISE NOTED (]ID
26.
27.
28.

3/4 PRESSURE REDUCING BACKFLOW PREVENTER FEBCO MODEL 825-Y OR EQUIV.~

FOR PROFILE VIEW & PIPE SUPPORT SEE DWG 6023269-19. ~

DRAIN VALVES FOR LEAK DETECTION AT LOW POINT OF SECONDARY LEAKAGE CONTAINMENT PIPE FOR LINE 6166 AND 6167. ~

UN IT DIABLO CANYON POWER PLANT - PG&E CO, SALTWATER SYSTEMS DRAWING SHEET PAGE REV 020 7 5

0 99 E