NOTE:
2 M RAW WATER 5_8l RESERVOIR RUN "G4" RUN "G3" RUN "GI" RUN "G2" 230KV TRANSFORMERS RUN "G" SHEET 2 SOOKV TRANSFORMERS RUN 11 A 11 SHEET 2 3
YARD RUN "M" SHEET 2 UNIT I FUEL HANDLING BLDG SHEET 3 4
LOOP FIREWATER TANK 0-1 FIREWATER PUMPS UNIT I CONTAINMENT STRUCTURE SHEET 7 UNIT I TURBINE GENERATOR BLDG SHEETS 4 & 4A AUTO SPRINKLER SYSTEM YARD LOOP RUN II B 11 SHEET 2 5
6
~D RADWA~I1 RAGE BLDG UNIT I UNIT 2 SHEET 2
.............. UNIT 2 AUX BLDG SHEET 5 UNIT I
UNIT 2 UN[T I UNIT 2 RUN "K" MANHOLE 7
FILLING STATION CO2 STORAGE TANK BUILDING DESIGNATION 8
9 SHEET 6 CO, FIRE PROTECTION SYSTEM TURBINE LO RM SWITCHGEAR RMS BATTERY RM CABLE SPREADING RMS DIESEL GEN RMS, UNIT I VAPORIZER CO2 VAPOR HEATER 10
@Im TURBINE GENERA TOR PURGE SW - SOL[D RADWASTE STORAGE BU[LDING YL - YARD LOOP A - AUXILIARY & FUEL HANDLING BUILDING C - CONTAINMENT BUILDING FIRE WATER HOSEREEL STATION T - TURBINE BUILDING I -
INTAKE STRUCTURE FW-100-A45-I UNIT NO. EXCEPT YARD LOOP AND SOLID RADWASTE BLDG STATION NUMBER BLDG DESIGNATION ELEVATION EXCEPT YL SYSTEM STATION FROM TH[S REV[S[ON FORWARD EACH SHEET WILL BE REVISED INDIVIDUALLY.
SHEET I DOES NOT REQUIRE REVISION WITH OTHER SHEETS.
REFER TO SHEET 18 FOR CHANGE
[NFORMATION.
CHANGE INFORMAT[ON SHEET CAN BE VIEWED IN THE W[P LlBRARY.
SHEETS 8 & 9 ELEV 54',60',64' 73' -0" 85" -0" 85' -0" I 00' -0" I I 5' -0" I 40' -0" I 00' -0" I I 5' -0" I 40' -0" 85' -100' 85', 100', 140'
<DETAILS I 91 '-0" 91 '-0" I 40' -O" I 40' -0" I I 5' -0" AREA MECH DWG NOS H & K 500 121, 500994 H & K 500122,500995 H & K 500123,500996 H
500124 H & K 500125,500998 H & K 500126,500999 H & K 500127,501000 J
500128 I
500129 J
500130 L
500131 G
500132 F,G 500155 G
500157 F
500158 G
500159 F
500160 SOLID RADWASTE 501012 M 16690 Exp. 3/31/00 I.
FOR HOSEREEL STAT[ON DETA[LS SEE MECHAN[CAL DESIGN STANDARDS 064358 & 064359. FOR SPECIFIC APPLICATIONS, SEE THE DRAINAGE AND FIRE FIGHTING DRAWINGS, LISTED IN THE TABLE (THIS SHEET). FIRE HOSE AND SERVICE WATER ISOLATION VALVES IN CLASS "G" PIPING REPRESENT CODE CLASS "G" BOUNDARY.
BASIC DIAGRAM UNIT INPG DATE 7/13/98 DES CR I PT ION OWN.
PMH2 Revised pe, FCT 02 3 2 3 8 R.E.
BSGI I NDEP.
VERIFIER P.E.
KJD3 REVISION INFORMATION COORDINATION NUCL.
MECH.
ELEC.
CIVIL PIPING l&C PIPING SCHEMATIC FIRE PROTECTION SYSTEMS DIABLO CANYON POWER PLANT PACIFIC GAS AND ELECTRIC COMPANY SAN FRANCISCO, CALIFORNIA DWG SCALE BILL OF MATL SUPSDS SUPSD BY SHEET NO.
OF 23 102018 REV 82