6 to Updated Finl Safety Analysis Report, Figure 7.3-2, Sheet 1 of 2, Drawing 338070, Revision 3, Logic Diagram Reactor Coolant Pump. Sheet 1
ML21305A335
Person / Time
Site: Diablo Canyon  
Issue date: 10/11/2021
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21306A142 List: ... further results
References
DCL-21-074 338070, Rev. 3
Download: ML21305A335 (1)


Text

~I

~I 0

0L08££ I

2 3

4 5

6 7

8 ii 9

10

"-1

"- I CS/START OVERLOAD 212

(----0 ON E

OFF E

Q 42-12J-18 NO, 14 CS/STOP 42-12J-13 NO.

12 7'

~

42-12I-37 NO.

I I 42-12I-21 NO.

13 REACTOR COOLANT 2/2

('\\PUMP RUNNING L/ 50 SEC RCWP THRUST BEARING OIL LIFT PUMP l\\

1CS/CLOSE(SWG;)

BREAKER~ 2/2 D

IN TEST 1_£'.0S IT ION__,

Q D

CS/START

~

RCWP THRUST BACK-UP BKR CLOSE 3/3 u

BRG OIL LIFT PUMP RUNNING

~

RCP OIL LIFT 2/2 PRESSURE

../ 120 SEC r:

NOTES:

CLOSE

!b CS/STOP 52 r

I. - DENOTES INTERCONNECTION TO OTHER LOGIC DIAGRAM, REF 5, TRIP PRIMARY BREAKER~

2. INDICATION LIGHTS ON MAIN CONTROL BOARD INDICATE BOTH THE PRI BREAKER & B-U BREAKER POSITIONS.

CS/TRIP(SWGR) 52VD6(RCPl4)

( 3.

12.)

52VD7(RCPl2)

FOR RCP BUS UNDERFREQUENCY LOGIC SEE REF.

(_i

-_, 12K V BUS U/V TR IP lOR]

52VE3( RCP I I) 52VE4(RCPl3)

FOLD REF, 5 TRANSFER TRIP SIGNA~

FOLD C

12KV BUS DIFF'L TRIP C

~

SEE NOTE 2 o:O ii'-

OVER CURRENT

\\J T

~o

~co RCP U/F BUS D(E){(NOTE 3 )/

)

~1'0

/

g; f'0 SSPS(TRAIN A) 2/2 -- --7 SSPS(TRAIN Al ~

2 I 2

'--1

REFERENCES:

DWG NO.

f ~----------0 REACTOR IN TEST POS er:

COOLANT SSPS TEST PB I

PUMP I. LOG l C SYMBOLS ________________________ '.:) 9425]

I

2. ELECTRICAL DEVICE LIST------------------ 050024 DEPRESSED

/"

LOSS OF FLOW INPUT 1/2 - SEE __.,_ ___ TO PROTECTION SYS, REF 12)

3. INSTRUMENT REF _______________________ I 02038 RCP U/F BUS 0( El (( NOTE 3) I
4. SLM&R 12KV BUS D&E _____________________ 437531 NOTE 2
5. LOGIC DlAG 12KV BUS SECT D&E AUTO TRANSFER ____ 19423 SSPS(TRAJN 8)

SSPS(TRAIN Bl ~

2/2

6. SCHEMATIC DIAGRAM SSPS TRAIN A ____________ 50 r 869

}

IN TEST POS

7. SCHEMATIC DIAGRAM SSPS TRAIN B ------------ 503088.,

I ~

SSPS TEST PB

8. SCHEMATIC DIAGRAM REACTOR COOLANT PUMP I I _____ 477846 B

B DEPRESSED

9. SCHEMATIC DIAGRAM REACTOR COOLANT PUMP 12 _____ 477847

,I

\\

I O. SCHEMATIC DIAGRAM REACTOR COOLANT PUMP 13 _____ 477848 CS/CLOSElSWGRl I I. SCHEMATIC DIAGRAM REACTOR COOLANT PUMP 14 _____ 477849 I 2. FUNCTIONAL LOGIC DIAGRAM PRIMARY COOLANT SYSTEM TRIP SIGNAL __ 495845-}

2/2 PRl BKR OPEN a

CLOSE \\ J CS/TRlP(SWGRl 52 b

TRIP OWG OWG TYPE SUBJECT DRAWING TITLE UNIT No, BACK-UP BREAKER G]

IRIEIAKITIOIRI lclololLIAINITI IPlulMIPI I I I I I I I "I I I RM INDEXED REV OVERCURRENT Q

52VD6R(RCPl4) 14 15 16 21 16-44 42 44

~

52VD7R(RCPl2)

PROJECT INSTALLATION DIVISION DD MAN DRAWING

'i'\\\\()fESSiol(,f 52VE3R( RCP I I )

LOCATION TYPE NAME MISC CODE HOURS CADD SOURCE

~,._,~

'f"..

V IDI IIAIBILlol

[]

[§]

@:@ I I I I [g

~

....._c.;

fC' INST 0/C 52VE4R(RCPl3)

~

-~R hn 45-50 51 52 53 55 56 57 59 60 70 i!!

m,

  • Jo s011

~

L/ 0. I 0 SEC

'I-No. 163

>)

NUCLEAR SAFETY RELATED

.r;-4 Ft tcnn c\\l.,.';_."'"

A 3

('{)

is.~

J/11/._

C I 2'?, I '/ l>/~!/'lv le Of Cf..l\\(ti A

REV REGISTERED ENGINEER SI GNAT URE CA REG NO.

EXP DATE COAST VALLEY DIVISIDN KEY Dk/G SECT _ 3_

UNIT I MICROFILM

..t3 APPROVED GM 167027 BILL OF MATL 3 1*/'t. <111-ADD NOTE 3, REF 12, REV REF DWG NO 1,6, 7 &

CAR lit, u.,

BY SUPV H HERTING LOGIC DIAGRAM DWO LIST REV LOGIC DIAGRAM (FCT-16395)

FJM DSGN E ZE ITER REACTOR COOLANT PUMP 19403 SUPSDS 2 4-6-87 REV LOGIC ACCORD TO SCHEME;ADD BACK-UP 167027 DWL LCV JC KC/S~C SA ON DWN E JOHNSON QC PROT LOGIC(DCI -EE 54l5)AS BUILT NAA CHKD E ZEITER SUPSD BY I 10-7-77 REVISED & REDRAWN IECO E189) 167027 ELJ EZ HH FJM ON JWC JWC OK HH WV DIABLO CANYON SHEET NO.

SHEETS DATE 9-14-77 DEPARTMENT OF ENGINEERING REV NO.

DATE DESCRIPTION GM/SPEC OWN CHKD SUPV APVD BY NO.

DATE DESCRIPTION GM/SPEC OWN CHKD SUPV APVD BY PACIFIC GAS AND ELECTRIC COMPANY 338070 338D70D.E62 0 I - I I -94 CAR R E V I S I 0 N S R E V I S I 0 N S SCALES SAN FRANCISCO, CALIFO NIA 3

JRH NONE NIB08 I

I I

~

I 2

~I 3

4 5

d1 6

7 8 ~I 9

3 10 Uli2-102787

"-