6 to Updated Final Safety Analysis Report, Figure 7.3-36, Sheet 2 of 2, Drawing 441489-1, Reactor Trip Breaker
ML21305A217
Person / Time
Site: Diablo Canyon  
Issue date: 10/11/2021
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21306A142 List: ... further results
References
DCL-21-074
Download: ML21305A217 (1)


Text

(LO<

CUTL IHE E

  • <Lo D

C B

<><D*

~ A N

a:,

0 w

C:

+-

Cl' C)

U 0

  • C:

"'CJ>:::,

coua;:

  • Z

-en~

s:::T co **

..-,.- L II -

t1) 0: "" "'

w.,- ::::,

f-VlZO

<1 C> <1 o:ou 4NPG 4 S 1.,.,

16Bt,lt,t, 2

3 Bf<..l=A/<.ER 5:z/ Jt:TA

(.SW(il't. C-ELL 1/3)

IJNOE/t.Yl!Jt:P-l,e f<EACTOI<.

5 0

5 mtPIF S2<!5YA IS 6

7 r s l:3~AKER, _§_2/13YB

( SWGR CELL 2C)

UND~"-.

V<UTA&li LOGIC TRAIN g

10 DESCRIPTION DfVICE No.

/:"UNCTION TYPE r./OlfG. NO.

REMARKS Sl/RTA Rtoclor Tri ~reolrer '-

(//)

Sl 'RfB

~actor Trip Breo~r wB'

,¥.E, (a (JI)

Sl/~YA R~lor &/PoSS 8r~er NA I UV SHUN/ /RI/'.,

BrR. CLOSE~0IOITI<>~ I*

t:>f'.EA/<./a/'<.. MN-IUAJ..

T"-IP C/f'-Q//TS

.j Tf'.IP

  • +

LOCAL TRIP K Cl.OSE / IN O/"'E~TinVI _ !NOIC/'\\TION_

t3_REAI<~ M,..,.;_UAL -~IP c1=.~~.,_r..s=--------+--

IN/'1Jrro I

§.l/8YB R!_oclor &Jposs 8Moker '8' I

~~ I *"-

i rns oe-1 ~

,----------------P.:-----------------------------,

p 7l*2IZ9

~p~

I

.JM t'.Q.!lleJ I

I I

I

... I ~,

~

~

~I 11

<:ll

~I

'11 ~,

9'.J ~

I CFU-0 I FOR BKR 72-2229 IS Ji, TO ERFDS

~XO I 2 Pl-----~

J

/I Cl

.ff!:

I RT/CS m,,.

Pl JD5 DJ L

L

  • 2*

CNAC L

2. _g;J__C__;C~~.2.
t.

I ll/lJJ(.T~I H

2SI / CS T/f.11" cc:z.

46 Ylt: l'Jfe>f L(>(;/C

~!NA t-------1 J B508 - l 1 T81 08-2

~+

RN SLA EZ El

~--==::========-=-P2~ -~_-_--:_-;;, _: _-;--7----i

, -~.:--o--P2.-AtL

£t,'.Y I

L......--4--111-.J":1 PORT82 L__f'.l c£~E~

52!51'A R ya t;.,."" I~,r,.,, y;,,."" 1':'M' I,,,;,~JP IO{li'i'IP 1,,-(RIP I OI/

'P C/,r;~.!:__2_:g;NAC ~F F

'L2----

2 -1=

CCI

-2

'-----'>-------+--------------"'~

~,('i

~1i

}---7z-r;-13----~
;~ -:- -~ ;.;--1~ 7 rr,---rz-i----7;- ; - N~~ ~;~

~ ~s ~;=---r,1

, ~
T I jsz l

~n~~i :~

i~n~~ :~

r I Tk{ f SZ i ~ ~n~~i
~i i~n~~ :~~ ; l '1 I G7s2 D

§~:~:

~a5

=~~:~ ~ffi I

lr;-lsz

~

'.3 §~:~:~_~a:l~

§~Ct
:_~_~ ~.r:3

~

I TX-TT l'l::

'<l'"**O--

V**:0---

lx Y

7C" O

Ct::

vc,;-- '-

,. z V<C-

  • o r-I UJ,XA 1-u..1!::!v,7-9.;._s; N~-;;

s: ~v-! 9:;

~---:!-.,

tt Z¥ I 1E ? <,,, e! Q,.;:,'ie,. :a:2 < "'a:Qx:=:. Eae <,. < ~-

""" "'" """, "", "'",..,, '°"",... :::

I '"'

,r~

sz o..

o

_, 3:::::i:z...J O.. LLJ ::::ia..

....1 =i3:::::,:zo... w ~o... a..

a..

-:AOV I I

1,/'1 U!:_~~-<l V) t..,_-.c:( V)

-<t _t-Cl~ -

t/11..L.c:(t/1 VJ Vl

~Q.!

I I s

~

1 ttttiiii tttitttt 1

1 I

I

& Ii 15 ~ Ii Ii & Ii

..,..,.... p. -

I I

"'1"'1"'! "'! ""i "'1"'1 <1 '

  • 1 I 1

0 0

0 0

0

.,, 0,. "

I IC') 0,. ~ ~ ~ ~ C\\i ~

~ =t ~ ~ ~ =t =t ~

I " ~ ~ -e;

~ = §~ -= ~t1/2 I

~

Ii) 0- ~ ~ t: ~ ~ ~ ~ ~ ~ ~ -'t :a:

i I

I a -

7 _

AUX. SIi. CONT AC TS _ s~~L~o?t, CONTAl~i~A/CI ll J L

2NC <NC 8NC IONC,2ic 14NC 16NC 18N':J jB - - - - - - - - - -j7 AUX. SW.

CONTACTS -

CE~~Es~oT t9N TA: Ts 52BYB/ C1?_J

.1

~n.,,

PORTB I 18FU-02 OcVICf S?/RTA L-------'

DEVICE" sz/~YB L

.£:!..____,6 ~

N =<J,=...-U:::::JJ--.,__ _________ __,

2CFU-02 72-2129 ICFU-02 N-~O---;lD)L--1>-.,_------------~

/JREA!fEI?

NO.

52/RTA

'il/RT8 FO =? l::IKH 72 - 2229 SW6R.

CELL NrJ.

/8 IC REACTOR TRIP 8RcAKER Sc/RTA, CIRCUIT NO. /~9D TYPICIIL SCHEMATIC OIA6RAH FOR REIICTOR TRIP BREAKER S?/RT/lf. 5!/lr'TB, EXCEPT AS SHOWN IN TABLE 8£(.0W.

ll5JIPC

!3R£Al(Elf L06/C UY SHUNT TRIP,A!IXIL/ARY ALARM CK!. NO. AL ARM CK T.

NO TIWN AUX. ANNUN.

MA IN ANNUN.

C!RC!J/T NIJ. LOCATION L()(AT!O!I RELAY RELAY REACTOR TR IP REACTOR TR IP

/291) f¢/fT/JJ

/0151.A UV.KA trfXt!J-AYWI//{)

AY07{)UJ) 2?9D f¢RT!3/

.R.NSL{J I UVXB

-flfKfc-

. ERf{)5 NO.

11UXt7/-t7-2 MllXot-cf-Z POR-R2 2BF J -02 FOR BKR 72-2229 REACTOR TRIP BYPASS BREAKER 5c/l3Y8, CIRCUIT NO. 1~90 TYPIC,4(. SCHEMATIC. DUG/UH FOi? RcACTOf' TRIP,BY.q,f.S,5 8RFAKi'lr 52/8Y8<# se/13YA, EXCEPT,4S.SHOWN IN T/IBlE Bel.OW BRfAl<ER SWOR.

,esvoc BREAl<EI? (. ()(jlC CONTACT CONTACT INPur ro j f-1O, CELL/VO. CIIKU!TN<J (.OCATION Tff.!_N /90flf-Joa, ~

LCGIC TR Sc/8Y8 zc lc9D

~RT82 ~

Tl?IP TRIP RNSLB S2/8YA

??./SYA --

52/BYII ZB 2c9D PfJRTBZ RMSU.

TRIP TRIP P..NSLA S?/BYB s2/sYe 61 Escutch,oa I

!llilli jRTlA,RTXt, IReocmr Trip&-r..WJ,Rtltl'f j;zoVAC 8~~~ii~Lal MDR IMDJi' /34-1 E*

. PORT32 H8 528YB

-C~

I I

I I UVM,l!Vl~ luv JHlJN[ !Rlf RllAY 48V PC t-'01 11:.H-MDI(

MDIWJ4-8RLiMF I ELD 48 VDC FROM LOGIC TRA" A i----1 TB508-~+/-

+/- :8108-1 BfilUJ i~

~'==1-CONTACTS.

. __,. *-*' ' REMARKS wwr. ACTUATEI, All o-i l--0 8/ I X

1 AJ,JNUNCIA10fi?.

Al~<>-1 f-oBI~ X SP/IRE Al o-/ 'r--08/

)(

t.OGIC TRAIN A 115 o-H-o BS X

LOGIC TRAIN 13 A6<>--11--0B6

)(

SPARE I 117 0-1 t-oB 7 X

C II 0--1 H> DI/

X CI Z <>-i l--0 D12

)(

Ct o-H-oOI

)(

TltJP 51/Rra C 5 o-/ l--0 D~-

X TA!P 52/RTA C-6 <>-l I-o D6 X

SPARE C7o->1t-oOT

)(

COMPt.JrER AUTQ SHUNT T/11! 7l5T GRAYH I LL SERIES!

Nlitr AJJTQ !HUNT TR!!' Bl/Xl GRA YH I LL !ERIES/

7*1',f CONT,4CTS POSITION.!

R.GM-4/N,*s RESET T~IP

'O Escutcheon IRT/CS TRIP 0

i~r: u tr: l'I eon 2Rr/cs All o-H-<> BIi AIZD-11-<> BIZ Al o-11-<> Bl AS <>-l t-<> BS A6 o-11-<> 86 A7 o-11-o B 7 Cl/ o-11-<>Dtl Cl!o-U--o Oil Cl o-U-oD/

CS o-11-<> DS C6o--ll-<>06 C7o-ll--<>D7

£ II o-lH F II E/2 o -o F IZ e I o-1 I--<>.CI

£7 o-j~.c~

E 6 <>-it-<>.C6 E7o-l~F7 6 I I o-l I-<> It' II QIZ<>-11--o ff' Ii 51 °-U-o#/

6 ; o--11-o JI; i,6 o-H---0 H' 6 Q 7 e>-11-o It' 7 UI I NT X

)(

)(

X X

)<

>< X X

X ><

X tl[Ul INT TRI IRT l2RT CL OSE 521,=n t..lSPA.RE X'

SPARE

)( AN/lit/NC/ATOR.

CLOSE 12/RTBISPARE X

SP/IRE X COMPUTER SPARE X

f.l"A~,:

X Tff.JP 52/R.TA

.SPARE.

X

.5.PARe X 1R IP 52./RT8 5f',IJ.,l?.E

)(

~ARe X

iR.IP SZ/BYB

.SPARE -

X

.$P,4RG X 7RIP.52/EJYA X X

-,f != NOTE 2.

>< X SPA.RE X )(

5EE NOTE. 3 X X SPARE CONTROi._.JWITC/.1 R£ACrOR TRIP

.!&:... llI:

cs ' cs V.J'£,!) 4T t.tJC.4TIOIY ill,&. CHY

.S,,Oli'/1'1"7 R£,r(/l?/V nJ IY£VrRA,:.

W:.E. CO-E'~ TYP£ W-2 ;Jf'OSITI01'/

@lJFJ.il:NT LOCATION NIJMB/iR$

CONTROL Jfll/TCh'*.fA;Err {!YJECT/tJN "!J ' 2c-¥ SD2I SWGR. IX 125 V BUS 2/

PORTB I CONT. PNL. RE,Al;TOR TRIP 8/?EAl<ERS,

PORTB2 CONT-PNL. REACTOR TRIP~ BKRS.

cct CONT* CCN. ;;MIN.* /.IIAKE-tJP'MfJi!FF, "1__

CONr. CON.PEACTOR CONTROL SZ/RTA ! >

SZ/RT8 Lf.

~1 II

,------r=:: !}MT/32 L.6UJ CONNECTION TO ROO CONTROi. /'ANELS All>

B,o C¢ 5Z/BY"1,--i-- '

m ~.

R

_ 5~8YBti-~

I ~.

~

?

PpRTBZ 1_ CIRCUIT l29DtS X

!illill elIBlllJ

~

)(I FU64

~

lJ\\..

~

~ ~

~..

,; ~

~~

(i '1\\-

~ t

<:, l;f

~ "I Is I

I I

I I 6 Jib 52RTA er us PORT82 E2 RNASA M5 12BYA

~

I, RTXA


--i

~*~JC I ~Ni( I \\~pl 8NC~l:~p 'ONCI

~ "'P We,

"'~

I

~

~

~3 w

1.:*1 u,

,£ a::

I J

c.:

s:

I I

'J°

~ 7 9

1.n..1,:: 1,iw:i 11:-tJ,:: 1 ':-t.1('

I 8NO I 8NC ~ I ?N( I iNO

I ~,~

.. c I"

~ -~*c re ~v-. --?~-I:

U I

e; e=,

~

~~

I J

I L __ ll __.,s __ 17

"': __ II _j CIRCU/7 22!JDIS X

RNASB PORTS I

~XI

>c V)

(\\J

~ "......

~~

~ 't

~ ':1-

~

FU64

/~~Ill,

~

l 12RTB lb O

cT

/17 I~

/ t, Iii PORTB I 115 12BYB

l. 528¥8

-r-rcr-

)1.,

PORTB2 I

£2

~

RTX8 1

I

N¥C r
N¥C I :~~~

NO 8NC~'~I°f~

I

"'~pil

a.
a.

<!~3:

Lu I

t/l V"l

~~c

'.:Sa:'.

°"

I I

<[

i..:

z 1 6 I

3

~~7-9 I

14NC 14NO 16NC 16NO

!ENO 18NC 12NO 12NC I ~v

~~T

~~ ~µTl

(./

a.

a..

a.
a.

l I

VI Vl VI VI L ___,1 __,s __,1 ___,, _J BUS CONNECTION FROM MG SET SYNC BREAKERS R£ACTOR TRIP 8R£AK£RS AUXILIARY RELAYS UfED AT LOCAT/OIY ~*

CCZ.

51'~1/Y(i R.!Tu'Rll ??l 1'1£dTRll L N,!. CtJr,o. Typ, ltl-2, 2,Dorir/or,, JI-~/,:,¥,:,, 5°tJ?'412~9-0I CNI etJWr.. BOARD CJEM. Yet. (bff. 5("ST&vl__

CN~ a)NT, BaA!V) ACWMUl.Art)R SefN/e,E ANNVIYC/4 roR DEVICE CONT,4CT CIRCUIV*~

OE.ICR/.PT/0#

/RT/CS A I <>*O-o Bl AY0T4SNI

?RT/CS Al <Hl-<> BI MAlltlAL l?EACT(n('TmP

/SJ/CS Al l<>-11-<> BI I csJ/cs Al l<>-H-<> 81 I.fr0705Di N,f/1'119' l.fFe/'Y l'#JEC/'ION St?/BYA 2J CX~l"-<>24 AY0751D RMCTPR Ji('//' 8Y.P,IF.r

.5,?/81"8 2J <<<<H~.>o14 tM'.iAKE.R IZOJEIJ COHl'CITER CIRCUIT N o'.s DEVICE CONT/ICT Cll?CUIT/'J.

52/li?TA 9 0-0--010 CYOOC6Df Sl/li'TB 9 <Hk>IO CY0007l)F 5</BYA 9 o-H-o/O CY00260G Sc/BYB 9 o-il--0/0 CY00270G

!RT/CS l.47~!--0B7 CY0 004 0G l/?T/CS A7<>-lk> B7 CY0005 0G ISi/CS cro-0-007 CY0B21/)

~SI/CS Cl<>-1t--oD7 (YO'}ZOJ)

TRAIN A TRAJNB

~

Hl °l 21 HIO

~ ~

52RTB l 52RTB b

Cl b-Tei 22 H9 22 H9 PCRTB I E.Q.!lI£J E4 E4 EIBill

~=

2, t:1 "; "'

m.!!..

~

~ 1 ~

b J CI b

T CJ 22 l HI 0 22 HI 0

, PORTB2 i

~ PORT32 E-E-

PORTB I 9 PORT81 EQB.la_l

~ e..Q..Bil_l E+

E-cKr NI.

E*

E-CKT,v~

Rl1SLA RA(:.!( N() SVEGUAR.f) LOGIC. A Rl1ASA

/?.40< NU AUX SA~ C4B A NOTES l CELL SWlrCII CC¥vTACTS SJiOIV/V WITH ~I< IN 0/'t=l{ArfNG /VSIT/ON.

L. 6/2 *Gii AND Hl/*H/2. AM JUlt/Pcl(El) IN MCJO(JLe. Cb/VlllCTS F/e.Of,I l!eT/C.S ANO

~T/cs Af'.e CO/VNl:CTl=D IN SE/~JES ANO FED INTO T~IN t, LOGIC INFUT.

-'* H~ -H5 AND G~-,5 Al'(£ JUM.PEl'.ED IN Mol)IJLE. CLJN'IACTS FMM /l{T/CS A/JD 21(.T / CS Af(E. Ct,N/-JECTEIJ IN Sl!l(./ES ANP /"Et> INTO TMIN 'A' /..06/C IN/'f/T,

4. FOR FUSE RA TING AND TYPE, SEE FUSE LI ST DWG. 066 145.

REFER.:/YC.: ORAlf'lll(f}S I. /Je1crl.Dlion 0./" £/ectric Jc/Jemofic [}109'. fvmMlf (Ciirvif/Je.rl9pq/-!011J

___________ tJ~OOOB

c.,frl(.fipme11I-tOc'11-hn l'lvmb~r Li.fl- _____________________________________________ ______

_ ______ /OJ {'(5

.3..ft"n9le Li;-;e #efer-Rei<7f LJhFrt:lA'l.,l~S Volt iJC f9sfem __

44~24C1

,I..fcl!emol/c !Jlo9rom lllr.0/111: ConfrQ/ ______________

_ ___ ______________________________ 4412 53

5. SCHEMATIC o: AGRAM AU X BO PLC POB2-IO Dl GITAL INPUTS & ~owER
  • ..fcnemof;c 1Jk9rom., Mo11.7,t/n/)(/nc1i7ror, 811.

____________________________________________________ 50D17S 7 S,nf//~ L1M Meter I Rehy ~,ugrum f;,stl'J A.C. Srsti:m ___________________ _4-4-/e,fl JI,, H5J!'O 8

Schemabi:: Oiaqram Control Rod t:Jr111e M-G Set Sit 2 -----*

________ ____________ 44/488 9 Reodar mp Swdcl,qeor


663197

/0. Fvnct ional LO<JIC 0,"c¥g-n:vns ------------------------------------------------------------------------------ 663 /95 I I. Solid Stqt~ Protection S 'lstem

____________________________________________________________ 663 23I IZ * $che111t1t1C [//atyr,m Control Rod Dr,n!

M*G Set Sh I ______________________________________ _44/487

13.

@) E /emen/trrl/ Wiring D1ag-mm ______________________________________________________________________________ 663193 14 SFISMIC T~ IP SCHEMATIC O'AGRAM _______________________________________________________________________,935/2.1#. ~

15. BLOCK D!AG. -[Rfl)S TECH 51/PPOl?T CENTER ANb CONT/?Ol ROOM ________________________________ 445297

/G, SCH£nmc DIAGRAM STEAM DIJNIP SYSTEM _______________________________________________________________ 4-4 1503 NUCLEAR SAFETY RELATED

~

)___

B C

P.G. &E. SYST EM PHASE SEO UEl1 CE

,\\-C-B "lf-Ct===::I=~* /'Z9Dl8

+-4*.:..=.-::::p

'129DM TBI06-4 ~~

-5 ~!lt!.ill TB5C6-, 2!ill:J.B -5 1/4!ill:J.B KEY DWG.

SECT ION 4

UN[T 2 REACTOR TRIPPED INPUT TIJ SAFEGUARD LOGIC

& FOR FEED WATER I SOLA T ft.UTO S. I. BLOCK I NTLK.

~

DATE OB-29-20 1 1 D. D.

MNRU R. E.

SM85 I. v.

P. E. I R2M5 REV!SlON DESCRI PTION REV I SED PER DAS-6 *426-0

~ :

ELECTRICAL SCHAEMAT IC DIAGRAM REACTOR TRIP BRE AK ER DI ABLO CA NY Or,,, POWER PLANT PACI F IC GAS AND ELECTRIC COMPANY SAN FRANC ISCO, CALJFORN{ A OWG SCALE:

BILL OF MATL :

SUPSDS:

SUPSD SY,

ORAWING 441 489 SHEET I POE I IE7 FOLD fOLO C7 0:,

jLO OL0 4

'"'