6 to Updated Final Safety Analysis Report, Figure 3.3-31, Sheet 1 of 4, Drawing 437600-1, Electrical Schematic Diagram Containment Fan Coolers
ML21305A216
Person / Time
Site: Diablo Canyon  
Issue date: 10/11/2021
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21306A142 List: ... further results
References
DCL-21-074
Download: ML21305A216 (1)


Text

{{#Wiki_filter:OLD4 CUTLINE E FOLD D C FOLD B 0-. ~ A r-- C sr Ol o u 00

  • C a, 0 o,+-

'U 0 .o 'o 0 0-v, Ul1z r-- ON rt')o"" V<<JL II I"'- Q) 0::..., (/) w " ::J f--- VlZO <( C)<( 0:: OU I 009L£\\7 A 4-BOV MCC BUS SE.CT IF E>-----i------ C -----ir--t--..--- 2 3 4 5 C' 0: L II 0.L.AUX REL HIGH SPEED LOW SPEED I CONTROL ROOM I HOT SHUT DOWN PNL 4KV AUTO BUS TRANSFER INOl SIS TI ME DELAY 1 CONTROL 1 SIS ROOM TIME DELAY I I 6 7 INDICATION CONTROL TRANSFER REL. LOW SPEED START AUX. RELAY FU-LA SPF H0 I i H=i+~-;::.2XI~>-+--------.-----------+------------+------+----------~-+-----+--+-----<---+--o FU-LsSPFCN~ I 42X2 IF-I FU-01-01 FU-01-02 I. SPF L II PCCFCll 42X-IF-IL 1 LOW T PCCFC~~ 21 SPF 42X-IF-I HIGH I x:TI =<ii.r-------+---------+-------------+------+-----------t:-----j---{,'--f--+------jl-----.--+-. PB f A lR*IF*I J STOP ~ CNC I SPF LOCAL SPF B -E2~-,.-...._ ___ f----------------+..:;-,-c, _,,__+------ B < P_CC_FCI B ~2-IF-I I 42-IF-I 41-IF-I 'l CS/NEUT ON 7 5 2FIAX A 42-IF-I CS/LOW 42-IF-I TI TI G LOW r ~-----.., I 1 l l :

' T 1 I

I L. -~- -- *..J ~ Q'. ~ SPF ,t---jf--------t---------o--,.o--51 -"i"O:C~ 400/SA 4--'c'---T-+--+---------<>-<;>--OC - CNC.l 21 23 ~B0/120V : ~ I CS/HIGH 42-IF*I CI CS/ON CNC I 9D I HI 2, 42X-IF-I *rCS/ON E5_H0I 4HFXFl,a HIGH +/-SPF TDC 18 11 H01 1


~

PCCF:,l I L4 DT CS/ON 5 J, 2FIX E '?CNCI T9 y,_PCCFCI IL Ml -~*2FI __ z:0~A SPF Ml 8 49 IF! ,ow 42 IF I LOW 42A It: I HIG.H SPF AL 8TG19[ ~ BTX23E ~ AL MPFI FAN CLR No. 12 ' M 42/FI H/6H r--:') 49/F I L5' HIGH \\ f,00/5A BH CH t ~ BH Cl-/ MOTOR CIRCUIT BKR. No LOC. PRIMARY BACK-UP CKT. No. MPF I 52-IF-I 52-IF-IR FO I POO 42A-IF-I ~ ~42-IF-I HIGH LOW '-,L----, S_P_F ----~ 42X-1F-1 sPF IH2 ]" H[GH 35 S_P_F ----'~ 'T 43X-I F-1 SPF IL SPF K608XF I ca 5 PCCFCI II 43X-IF-1: 13 ~ 49X-IF-I 2 PCCFCI SPF 1H L 2F I AX , - Al A3j1 O PCCFCI I, 11el ::!f I ~IH4-0 18 43X-IF-1 I" I SPF

tJ ~ 12 I

A2 A< I 2F IX L... ----10 49-IF-I PCCFCI IHl SPF 42X-IF*I HIGH r 2 14 16;:::::c:LII 9 ] 7 ~l ~l ~l ~~l ~l : 1 iT ~T ;1 ~ T iT 1 I s 1s 11 V)2J a I L __________...J 49-IF-I 37 21 43X-IF-I; 23 9 PCCFCI j ---0-IL I-<>------~ SPF 2FIX 2FI/TD


7 ii 13 zls I -

2 1 6 ii Bl ii' RI Ti1:R1 T1 3 R3 T1 4 R4 i 7-I 7 1_..... I "- ~-.... ~:; - ~ ~:; -~-.... I I / 7 -.-~; ~ ~- -~? - ~--

- ~-.... ; - II I

tr: V, N V> I I ~! V, V, V, I 14 ~ I I B4 x ~ ii I I ~ 1--- I I ~ ~ - ~ I I 9 10 I I Ml M1 Ml M4 I RELAYHA54-POLES~


PC~I~ SPF _____ _J ONLY 2 ARE SHOWN 2F I AX FOR CLAR I TY 1- - -

7

13 ls :

2 16 : RELAY HAS 4 POLES I 7 7 ~ 2:: ~- ~ I ONLY 2 ARE SHOWN I .t.

.t-,~, -
:;; ~1 -~-* I FOR CLARITY I 14

~ V'>

  • I I

I I I I_ - 9 IO I PCCFCI ~------------------,----¢----~ OL/LOWT OL/HIGH PCCFCI SPF i 49-IF-I x2 ____.._l..__~.._ ___________________________________ __.,~ L=/~LO=W~-----+-~' S_P_F 120VAC CONTROL SCHEMATIC I ~

==~==~==~ I J 4!7G': I BA s-21'-2 IF I LOW 10 42 IF I LOW j /I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -cNOT;,- CONTAINMENT FAN COOLER No. 12 CIRCUIT No. FOIPOO CONTAINl-1ENT FAN COOLERS No's 11, 13, 14 & 15 SIMILAR EXCEPT AS SHOWN IN TABLE CONDENSATE DRAIN SYSTEM BUS PENN SIS AUX RELAY 1--~~~-~~~----~=~=~~~c-1125V DC VALVE SV SV SW CONTACT CONTACT DEVICE FOR IND. SECT. NO. No. No. LOC. FOR sv HI-HI

  • HIGH
  • VLV POS CKT. No.

CK T. No. PENN No. IF 29E K609XF I LCV125 125 XSV125 43CDV (Cl LS73R LS72 43CDV II 241D l0125SVOI 2E ALARM CIRCUIT No. s ERFDS OVER-TRANSFER VIBHRIAGlHIDN DRIP PAN DRAIN LEVEL CURRENT OF CONT MOTOR & FAN HIGH LOW MUXOl-24-3 AI0413DF AY5065DF AY0408D AY2501D AY2502D FOR OTHER CFCU'S SEE APPLICABLE DETAILS ON 437600-2 AS SHOWN IN TABLE NOT USED1 COMPUTER CKT. No, CNT ISOL PH.A BREAKER 1------+-'fll~l=OR-'--'-iOCr-B~Y~PA=S.c.aS CLOSED DEVICE CONTACT CYIOOIDF C.O. SW POSITION CONTROL TRANSFER RELAY CUT-OUT SW NORMAL CUT-OUT FUSES PRIMARY (CONT, CKT. l FU-01-01, FU-01-02 " 42 IF-I LOW I I NOR/rlAL ';cur rN ~J-G CUT OLJ1 (RJR FAN CLRS

II_,

13& 14) ALARf/11 I!£ IN PARALLL ;,/Ac4/?M CONTACT OF RLY-S 4;;t.-JF-~ lf:i--..',JW-/ FUSES SECONDARY (CONT, CKT. l FU-0 I -03, FU-LA, FU-LB I I MPF2 52-IF-2 51-IF-2R F02POO IF 32E K608XF2 LCV120 120 XSV120 43CDV I Bl LS71 LS70 43CDV IH 10120SVOI MUXOl-24-2 A I 04 I 2DF AY0407D CYIOOODF NORMAL CUT - IN FU-02-01, FU-02-02 FU-02-03, FU-LA, FU-LB 13 14 15 MPG I 52-IG-I 51-IG-IR GO I POO IG 9E K608XGI LCV126 126 XSV 126 43CDV ID) LS75 LS74R 43CDV IJ 10126SVOI MUX02-20-4 AI0414DG AY5066DG AY0409D MPH I 52-IH-I 51-IH*IR HO I POO IH 3E K609XHI LCVl29 129 XSV129 43CDV IE) LS77R LS76 43CDV IK 10129SVOI MUX03-II-I Al0415DH AY5067DH AY0410D MPG2 52-IG-2 51-IG-2R G02POO IG 15E K609XG2 LCV 130 130 XSV130 43CDV IFl LS79R LS78 43CDV IL 10130SVOI MUX02-25-3 AI0416DG AY04 I ID

  • LEVEL SWITCH LOC. PMl24 SIS AUTO BUS TRANSFER SHFl2 SPF AUXILIARY RELAY AUXILIARY RELAY

~-o--::sF5-3-~-->-----------------~ RNS,e/A SPF 8F4-4-0-- K609XFI 4HFXFI i+- 5 I-6 2 7 3 8 4 I I 13 - -1 51627384 I 13 I I I I '

  • I I

I I I I L 0 f-- I 4 9 w a:: <(

a.

Vl 10 w , a:: <(

a.

Vl I I w a:: - <( -

a.

Vl 12 I I I w I > a:: I<'~ I Vl I I w w a::, a:: <( <(

a.
a.

Vl v, w 0:: <( Q. Vl 0 f-- <( 0 w Vl

u. -

N - f-- f-a:: 0 z < --~ f-- Vl w w ~=~~

a.
a.

Vl Vl I 1 14 9 IO I I 12 L_ ----------------- '---0-0F-ct-o----------------~ SHFl2 SPF SHGl2 ,----0---8G5-4 _j RNS0B ( REF. 5 l ~ :: 8G4-7 OG SHGl2 SHFl2 ,----o---BF5-3 _j RNS0A (REF.4)~ 8F4-3 OG SHFl2 SHGl2 ,----o---BG5-4 _j _fil,I S g/B ~11---0-- 8 G 4 -6 (REF.5) OG SHGl2 SHHl2 ~--<-::>--8 H 5 - 3 SHHl2 SPH ,----0--- 8 H 7 - 2 ] ~~ _fil,IS0A (REF.6)@ 8H7-2 SHHl2 Lo-- OH PM 124 ~o:: o-- X -c1--..... ------------------ 0 N sr "' 0 0-. o._ r--..., 0 z 0 f--- z u 3c u 0 <( LL 0 w N 0: ~---u El FU5 FU15 PMl24 ~ BTG33E ~ BTX33E El ,, XLS74 ,-~--------1 I e---------NC I I LI I I L2 LS-74 I I , C I L-1------- __ I u XLS74 u E2 E3 BTX33E IX BTG33E E2 E3 PMl24 LS-74R PMI 24 <02 6 5 4 3 " 7 L_ w ); 0 <t :;::

0.

I Vl f-- 8

u.

w a:: a:: w a:: <

a.

Vl '~

3---~

<( CONDENSATE DRAIN SYSTEM LEVEL MONITORING CYl002DG CYl003DH CYl004DG Q_ _J w z <tN Q__ zN I NORMAL CUT - IN NORMAL CUT - IN NORMAL CUT-OUT OFF! 2 \\

  • ,3.,
  • 5 NO SPRING RETURN FU-01-01, FU-01-02 FU-0 I -03, FU-LA, FU-LB FU-01-01, FU-01-02 FU-0 I -03, FU-LA, FU-LB FU-02-01, FU-02-02 FU-02-03, FU-LA, FU-LB POSITIONS CONTACTSr0~F~F~-1-i-~2---i-'-~3"--r-4~~5-1 REMARKS

~ I-A X 1-f-B I-I-C HI-D HI-E YI-F .-<I-G X HI-H HI-I HI-J HI-K YI-L SPARE X FAN COOLER I I !THIS DWGI X FAN COOLER 12 ITHIS DWGI X FAN COOLER 13 ITHIS DWGI X FAN COOLER 14 ITHIS DWGI X FAN COOLER 15 ITHIS DWGI SPARE X FAN COOLER I I ITHIS DWGI X FAN COOLER 12 ITHIS DWGI X FAN COOLER 13 ITHIS DWGI X FAN COOLER 14 (THIS DWGI X FAN COOLER 15 !THIS DWGI SELECTOR SWITCH 43CDV USED AT LOCATION CNCS I REF 21 I KEY DWG. SECTION 4 C' a' 8 0' DEVICE NQ AA-: CT 4HFXFl,4HFXF2,4HGXGI 4HGXG2,4HHXHI 4 -fF-1 l.E=2._ /G-1 _J_Q:-1_ -lrH 4r-1F-l 1:df~;~; ~~;~ l~ 4@.- ll=-1 11='-.2 -IG,-1 IG-:2 -IH-1 I.OW l "-.OW ;"UwllL.OW l"['V7;' - H - I l..t...,:..'- I {, - I I lli..:.l LOW LOW 'T"l"fGT' 'TOW -I~- IF-2 IG-1 ,n-l H I G H ' l:l"T'?'T]

  • R""f1'n:I I i7 H ' H I G H K608XF1,K608XGl,K609XFl,K609XHl,K609XG1 49X-IF-!, JF-2, 16-J, IG-2,IH-!

52-lf-l, IF-2,IG-l,-IG-2,-IH-I .52*1F-IR,2R .SZ-IG-IR, 2R 82-IH-IR FCV sv LS73R, LS74R,(LS77R, LS79R LS 9 TABLE oF DEVICES FUNCTION RAT:NG MFR TYP!a CAT/DWGi-Jll, AMMETER 511 WECOPf CURRENT TRANSFORMER 4C0/5A /E CO,Rf EC/ AUTO BUS TRANSFER SIGNAL AUX RLY 120V AC P & B KHU MOTOR AUX STARTER (HI SPEED, !BOl'AC WE. WRF v10TOR STARTER (HIGH SPEED) 48/JVAC WE LORP ftlOTOR STAP.TER (LOW SPEED) 480 VA( ~

MOTOR STARTER AIJXILIARY RELAY 12 o V AC LOW SPEE.D START AUX RELA1 120V AL 1<i E,CDll.r' A11.420A MOTOR OVERLOAD (HIGh SPEE Ji WE CO'

YE COl<f WE CORP PB KRP 644B637Al9 237A970G06 KHUl7Al6-110 /3)(7)(8) (IO) KRP I I AG

11) 7803~

10 PEMARKS SCALE 0-400A PART Of MOTOR STARTER PART OF MOTOS: STARTER PART OF MOTOR STARTER PART OF MOTOR STARTER NORM, ENERGIZED HAND RESET YS9, YSIO, YSI I, YSl2, YSl3 MOTOR V1BR!'TION SWITCH >-----------+-------------1/ZSV QC OBERTSHAW 36b ELECT. & HANO RESET CONTACTS TO BE CONNECTED YSl5,YSl6,YSl7,YSl8,YSl9 fAN 3G6A IN PARALLEL PER ALARM CKTS. 2F2X,2F2AX 2FIX,2FIAX 2GIX,2GIAX 2HIX,2HIAX 2G2X,2G2AX 42X-IF-2L,42X-IF-IL 42X-IG-IL,42X-IH-IL 42X-IG-2L 2F I, 2F2, 2G I, 2G2, 2H I 2F2A,2FIA,2GIA 2HIA,2G2A DETAIL DRAWING THIS DWG A 437600-2 B 437600-2 C 437600-2 D 437600-2 SAFETY !NJ SIGNAL AUTO XFR AUX RELAY 120V AC P&B KHU KHUl7Al6-110 CFCU II, 12, 13, 14 & 15 A200MOCACDEJ4 LOW SPEED START AUXILIARY RELAY 120V AC C -H A200 OR A201KOCA CFCU 11, 11, 13, 14 & 15 W/141JII OR J20 AUX. CONTACT SETS INSTALLED SAFETY !NJ SIGNAL TIMING RELAY 120V AC AGASTAT ETR ETR-1413D-004 CFCU 11, 12, 13, 14, 15 AUTO TRANSFER TIMING RELAY 120V AC AGASTAT ETR ETR-1413D-004 CFCU 11, 11, 13, 14 & 15 POSITIONS CONT.4CTS OFF NEUT. ON R£t.1ARKS -ii-- ~ X X THIS DV'IG --,1---- B X T/115 DWG S Al T. H 42 !Fj 42 IF2, !2 /G_/ 42 !G c 42 If! 1 C01VTROL L,, I IC I - cs c.s C5 ' cs c.s !/SE[) AT LOCATION H(!I SPRING RETURN TO NEUTRAL aJNrROL LOCAL ROOM (§) CONTACTS -ii-A -,I-B


,1-C

--1t-D POSITIONS X X X REMARKS Tl/IS D/1'/G THIS DWG SPARc TRANSFER SWITCH 43R IF/. IF z_ 161-/6 2 -/fl-I USED AT LOCATION II@! NO SPRING RETURN lww HIGa I (§) SELECT O PUSH OPERATOR CONTACTS --11-- A --1 f-B --I>- C --if-D PO.SI TIO/VS LOW HIG!I >--~--+---~---< REMARKS Rfi.EA5[) DEPRESSED REiEASi) EPRESSEO X X {H,3 owe, X .X THIS EV/G X THIS DW6 X THIS ul," CONTROL SWITCH 421FI cs 421F2 cs 421GI 421G2 421HI cs cs cs USED AT LOC.4 T/0,V CNCI NOTES: I. ROBERTSHAW VIBRASWITCH MODEL 366-A-7 PER NMOD/RPE ORDER 60045749. EQUIPMENT LOCATION NUMBERS: CNCI _CONTROL BOARD CONTAINMENT VENTILATION ISECT. IVBI l H0'1 - HOT SHUT DOWN REMOTE CONTROL PANEL I. MPFI -CONTAINMENT FAN COOLER 12. SHF12-4KV SWITCHGEAR BUS F CUBICLE 12 SPF -480V MOTOR CONTROL CENTER BUS SECTION IF. BTG2E - TERM] NAL BOX G2E CNCS _ CONTROL BOARD CONTAINMENT SPRAY ( SECT I VB I l XSV I 30- INSTRUMENT NO. SV I 30 LOCAL MOUNTED. SPFR-480V MCC BUS SECTION IF,BACK-UP O.C.

REFERENCES:

I. DESCRIPTION OF ELECTRICAL SCHEMATIC DIAGRAM DWGS: SYMBOLS & CIRCUIT DESIGNATION.--------------------------050003

2. EQUIPMENT LOCATION NO.S. --------------------------------

101900

3. SINGLE LINE METER & RELAY 480V BUS SECTION IF.----------- 437916
4. SCHEMATIC DIAGRAM 4KV BUS F AUTOMATIC TRANSFER. ----------437625
5. SCHEMATIC DIAGRAM 4KV BUS G AUTOMATIC TRANSFER. ----------437626
6. SCHEMATIC DIAGRAM 4KV BUS H AUTOMATIC TRANSFER. ---------- 437627
7. SINGLE LINE METER & RELAY 480V BUS SECTION IG.------------437542
8. SINGLE LINE METER & RELAY 480V BUS SECTION IH.------------437543
9. PIPING SCHEMATIC VENTILATION & AIR CONDITION SYSTEMS.----- 102023 FOLD FOLD

~o io ~ U) C r--..., OLD4 I I. I 2. INSTRUMENT SCHEMATIC LEVEL INSTRUMENT SYSTEM. ____________ 102033 1--- REVIS[ON DESCRIPTION SINGLE LINE METER & RELAY 125V DC SYSTEM.----------------.437546,

445075, 445076 13, CONTAINTMENT FAN COOLERS ________________________________ REC.NO.

663079

14. SCHEMATIC DIAGRAM MAIN ANNUNCIATOR SH. I.---------------- 501121
16. SCHEMATIC DIAGRAM MONITOR LIGHT PANEL C. -----------------437698
17. LOGIC DIAGRAM, __________________________________________ 19407
18. SCHEMATIC DIAGRAM SIS MOV'S. ---------------------------- 437606 19, SCHEMATIC DIAGRAM MONITOR LIGHT AUX. RELAY*--------------*445287 20.BLOCK DIAGRAM EMERGENCY RESPONSE FACILITY DATA SYSTEM*----*445278 2 I. BI LL OF MATER I AL VERT I CAL BDS

______________ - - - - - - - - - - - - IO 194 I NUCLEAR SAFETY RELATED UNIT I DWG SCALE: ~ ,,( B C P,G.&E. SYSTEM PHASE SEQUENCE A-C-B DATE 04-17-2019 Revised Per DFT-7*4827 ELECTRICAL SCHEMATIC DIAGRAM CONTAINMENT FAN COOLERS BILL OF MATLc D. D. V!BRi!T/0/(BESET CKT J10 I0003YS02 CONDENSATE DFIAIN SYSTE.f:1 E'cxTs LJSTED ON DWG 10.a*~o"'.;..""9"-"'5-=======--- R. E. I. V. P. E. 4NPG "I S lze I I I I I I ZNS4 RXG2 NIA N/A I DIABLO CANYON POWER PLANT PACIFIC GAS AND ELECTRIC COMPANY SAN FRANCISCO, CALIFORNIA I U2-441313 I SUPSDS: SUPSD BY: DRAWi NG SHEET PAGE REV 437600 I O 42}}