Category:Graphics incl Charts and Tables
MONTHYEARML21286A5422021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Table 14.5, Analyses of Abnormal Operational Transients ML21286A3972021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.12, Process Radiation Monitoring Systems Characteristics ML21286A3422021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 4, Table 4.9, Reactor Water Cleanup System Equipment Design Data ML21286A3592021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 6, Table 6.4, (Deleted by Amendment 13) ML21286A3762021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.1, Systems (or Portions of Systems) Required to Mitigate LOCA And/Or HELB ML21286A3732021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.2, Reactor Protection System Instrumentation Specifications ML21286A3682021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.3, Primary Containment Isolation ML21286A3892021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.7, Reactor Manual Control System Instrumentation ML21286A3952021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.6, Refueling Interlocks Effectiveness ML21286A5662021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Table 14.13-1, Results of BFN Atwsi Evaluation ML21286A5522021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Figure 14.5, Analyses of Abnormal Operational Transients ML21286A5502021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Table 14.4, Approach to Safety Analysis ML21286A5482021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Table 14.6, Iodine-131 Activity (Ci) by Location as Function of Time for CRDA ML21286A5432021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Table 13.5, Startup and Power Test Program ML21286A4042021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.13, Area Radiation Monitoring ML21286A5322021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Figure 14.6, Analysis of Design Basis Accidents ML21286A5282021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Figure 14.4, Approach to Safety Analysis ML21286A5162021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 10, Table 10.17, Process Sampling Systems ML21286A4942021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 10, Table 10.11, Power Block Structures ML21286A4602021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 10, Table 10.4, Tools and Servicing Equipment ML21286A4572021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 12, Table 12.2, Reactor Building Concrete Structure Base Slab Design Data ML21286A4522021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 12, Table 12.3, Plant Radiation Zone Classification ML21286A4272021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 8, Table 8.4, Normal Auxiliary Power ML21286A4242021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 8, Table 8.6, 250-V DC Power Supply ML21286A4232021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.20, Design Output Documents ML21286A4142021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 8, Table 8.5, Standby AC Power Supply ML21286A4092021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.16, Process Computer System ML21286A2772021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 2, Table 2.3, Meteorology ML21286A2232021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Appendix G, State B ML21286A2222021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Appendix G - BWR Operating States ML21286A2262021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Appendix G, State D ML21286A2272021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Appendix G, State a ML21286A2622021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 1, Table 1.11, Id Resolution of Construction Permit Concern - Summary ML21286A2522021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 1, Table 1.4-1, Class of BWR Systems Criteria Requirements for Safety Evaluation ML21286A2662021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 2, Table 2.5, Sheets 1-3, Historical Earthquake Listing 200 Mile Radius Around 87.11 W Lon 34/71 N Lat ML21286A3172021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 4, Table 4.3, Reactor Recirculation System ML21286A2002021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Appendix a, AEC General Design Criteria - Group 1 (Overall Plant Requirements) ML21286A2722021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 1, Table 1.7, Comparison of Nuclear System Design Characteristics ML21286A3482021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 6, Table 6.5, Plant Parameters Used Locaa Analysis ML21286A3542021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 6, Table 6.3, Emergency Core Cooling Systems Equipment Design Data Summary ML21286A3672021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.5, Neutron Monitoring System, SRM Trips ML21286A3962021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 7, Table 7.8, Reactor Vessel Instrumentation ML21286A3122021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 3, Table 3.2-1, Deleted by Amendment No. 16 ML21286A3132021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 3, Table 3.3, Reactor Vessel Internals, Mechanical Design Data ML21286A2962021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 4, Table 4.2, Reactor Pressure Vessel Materials ML21286A2822021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 2, Table 2.4A, Maximum Possible Flood ML21286A2842021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 2, Table, 2.4, Deleted ML21286A3112021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 4, Table 4.4, Nuclear Steam Pressure Relief System ML21286A3242021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 3, Table 3.6, Definition of Fuel Design Limits ML21286A3432021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 4, Table 4.8, Residual Heat Removal System Equipment Design Data 2021-10-04
[Table view] Category:Updated Final Safety Analysis Report (UFSAR)
MONTHYEARML23335A0672023-10-31031 October 2023 Updated Final Safety Analysis Report (Fsar), Amendment 30, Public Use Redacted ML23278A0122023-10-0505 October 2023 Updated Final Safety Analysis Report, Amendment 30 ML22049B3242021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Appendix N, Unit 1 Cycle 14 Reload Analysis (July 2020) - Redacted ML21286A5542021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.2, Unacceptable Safety Results for Abnormal Operational Transients ML21286A5582021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section, 14.12 Analysis of the Primary Containment Response ML21286A5402021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Section 13.3, Training Programs ML21286A5442021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Section 13.4, Preoperational Test Program ML21286A5362021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Table of Contents ML21286A5312021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Section 13.9, Refueling Operations ML21286A5502021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Table 14.4, Approach to Safety Analysis ML21286A5372021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.8, Analytical Methods ML21286A5482021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Table 14.6, Iodine-131 Activity (Ci) by Location as Function of Time for CRDA ML21286A5262021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Figure 13.2, Organization and Responsibility ML21286A5242021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 10, Section 10.20, Auxiliary Boiler System ML21286A5292021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Section 13.5, Startup and Power Test Program ML21286A5522021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Figure 14.5, Analyses of Abnormal Operational Transients ML21286A5352021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Table 14.8, Analytical Methods, ML21286A5332021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Section 13.2, Organization and Responsibility ML21286A5462021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.6, Analysis of Design Basis Accidents ML21286A5672021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Table 14.11-1 Through Table 14.11-9 (Deleted) ML21286A5692021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.11 Analyses of Design Basis Accidents (Deleted) ML22049B3192021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Appendix 2.4A, Probable Maximum Flood (PMF) - Redacted ML21286A5652021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Plant Safety Analysis, Table of Contents ML21286A5602021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Figures 14.10-1 Through 14.10-20 Deleted by Amendment 28 ML21286A5622021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Figure 14.8, Fuel Rod and Fuel Bundle Details ML21286A5662021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Table 14.13-1, Results of BFN Atwsi Evaluation ML22049B3212021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 8, Figure 8.6, Instrument and Controls DC and AC Power System - Redacted ML21286A5592021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.9, Deleted ML21286A5552021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.5, Analyses of Abnormal Operational Transients ML21286A5472021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.4, Approach to Safety Analysis ML22049B3222021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 10, Section 10.12, Heating, Ventilation, and Air Conditioning Systems - Redacted ML21286A5302021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Figure 13.5, Startup and Power Test Program ML21286A5382021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Section 13.10, Refueling Test Program ML22047A1602021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 2, Figure 2.2, Site Description - Redacted ML21286A5562021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Figure 13.6, Normal Operations ML21286A5392021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Section 13.6, Normal Operations ML21286A5222021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 10, Section 10.25, Emergency High Pressure Makeup (Ehpm) System ML21286A5232021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 10, Section 10.18, Plant Communications System ML21286A5492021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.1, Analytical Objective ML21286A5642021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.10, Deleted ML21286A5682021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.13, Anticipated Transients Without Scram with Instability (Atwsi) ML21286A5532021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Figure 13.4, Typical Preoperational Test Sequence ML21286A5452021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Section 13.8, Operational Review and Audits ML21286A5322021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Figure 14.6, Analysis of Design Basis Accidents ML21286A5422021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Table 14.5, Analyses of Abnormal Operational Transients ML21286A5432021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Table 13.5, Startup and Power Test Program ML21286A5342021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Section 14.3, Unacceptable Safety Results for Accidents ML21286A5512021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Section 13.7, Records (Deleted) ML21286A5272021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 13, Conduct of Operations, Section 13.1, Organizational Structure of the Conduct of Operations ML21286A5282021-10-0404 October 2021 Amendment 29 to Updated Final Safety Analysis Report, Chapter 14, Figure 14.4, Approach to Safety Analysis 2023-10-05
[Table view] |
Text
BFN-18
Table 7.13-1
(Deleted by Amendment 13)
BFN-18
Table 7.13-2
LOCATIONS OF AREA RADIATION MONITORS
Unit 1
Sheet 1
CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR
Floor Approx TVA Station Range Elevation Col Inst No. MR/HR Feet No. Description Number
1 0.1 1000 664.0 px-R5 Fuel Storage Pool Area - RE-90-1 Reactor Building
2 0.1 1000 664.0 ux-R3 Service Floor Area - RE-90-2 Reactor Building
3 0.1 1000 639.0 p-R5 New Fuel Storage - Reactor RE-90-3 Building
4 0.1 1000 639.0 s-R5 Recirculating Pump MG Set Area - RE-90-4 Reactor Building
5 0.1 1000 617.0 d-T4 Generator Operating Floor - RE-90-5 Turbine Building
6 0.1 1000 617.0 e-T6 RFP Operating Floor - RE-90-6 Turbine Building
7 0.1 1000 617.0 k-T3 Turbine Operating Floor - RE-90-7 Turbine Building
8 0.1 1000 617.0 p-R7 Main Control Room RE-90-8
9 0.1 1000 621.25 t-R6 Cleanup System Area - RE-90-9 Reactor Building
10 Not Used
11 0.1 1000 586.0 b-T6 SJAE and SPE Area - RE-90-11 Turbine Building
12 0.1 1000 586.0 d-T6 Feedwater Heater Area - RE-90-12 Turbine Building
13 0.1 1000 593.0 p-R6 North Cleanup System Area - RE-90-13 Reactor Building
14 0.1 1000 593.0 s-R6 South Cleanup System Area - RE-90-14 Reactor Building
15 0.1 1000 577.75 b-T2 Decontamination Room - RE-90-15 Turbine Building
16 0.1 1000 557.0 c-T4 Hotwell Pump Area - RE-90-16 Turbine Building
BFN-18
Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS
Unit 1 (Continued)
Sheet 2
CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR
Floor Approx TVA Station Range Elevation Col Inst No. MR/HR Feet No. Description Number
17 0.1 1000 557.0 f-T4 Condenser Corridor - RE-90-17 Turbine Building
18 0.1 1000 557.0 f-T6 Condensate Demineralizer Area - RE-90-18 Turbine Building
19 0.1 1000 565.0 j-T3 Outside Steam Line Cavity - RE-90-19 Turbine Building
20 0.1 1000 565.0 r-R2 CRD-HCU West Area - RE-90-20 Reactor Building
21 0.1 1000 565.0 r-R6 CRD-HCU East Area - RE-90-21 Reactor Building
22 0 106 565.0 p-R5 TIP Room - Reactor Building RE-90-22
23 0.1 1000 565.0 p-R5 TIP Drive Area - Reactor RE-90-23 Building
24 0.1 1000 519.0 u-R1 HPCI Room - Reactor Building RE-90-24
25 0.1 1000 519.0 u-R1 RHR West Room - Reactor Building RE-90-25
26 0.1 1000 519.0 n-R1 Core Spray - RCIC Room - RE-90-26 Reactor Building
27 0.1 1000 519.0 n-R7 Core Spray Room - Reactor RE-90-27 Building
28 0.1 1000 519.0 u-R7 RHR East Room - Reactor Building RE-90-28
29 0.1 1000 519.0 u-R7 Pressure Suppression Pool Area RE-90-29 Reactor Building
32 0.1 1000 568.0 - Stack Room RE-90-32
BFN-18
Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS
Unit 2
Sheet 3
CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR
Floor Approx TVA Station Range Elevation Col Inst No. MR/HR Feet No. Description Number
1 0.1 1000 664.0 px-R11 Fuel Storage Pool Area - Reactor RE-90-1 Building
2 0.1 1000 664.0 ux-R10 Service Floor Area - Reactor RE-90-2 Building
3 0.1 1000 639.0 p-R10 New Fuel Storage - Reactor RE-90-3 Building
4 0.1 1000 639.0 s-R10 Recirculating Pump M-G Set Area - RE-90-4 Reactor Building
5 0.1 1000 617.0 d-T8 Generator Operating Floor - RE-90-5 Turbine Building
6 0.1 1000 617.0 e-T6 RFP Operating Floor - Turbine RE-90-6 Building
7 0.1 1000 617.0 k-T9 Turbine Operating Floor - Turbine RE-90-7 Building
8 Not Used
9 0.1 1000 621.25 t-R9 Cleanup System Area - Reactor RE-90-9 Building
10 0.1 1000 586.0 j-T6 Feedwater Heater Area - Turbine RE-90-10 Building 11 Not Used
12 Not Used
13 0.1 1000 593.0 p-R9 North Cleanup System Area - RE-90-13 Reactor Building
14 0.1 1000 593.0 s-R9 South Cleanup System Area - RE-90-14 Reactor Building 15 Not Used
16 0.1 1000 557.0 c-T8 Hotwell Pump Area - Turbine RE-90-16 Building
17 0.1 1000 557.0 f-T8 Condenser Corridor - Turbine RE-90-17 Building 18 Not used
19 0.1 1000 565.0 j-T9 Outside Steam Line Cavity - RE-90-19 Turbine Building BFN-18
Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS
Unit 2 (Continued)
Sheet 4
CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR
Floor Approx TVA Station Range Elevation Col Inst No. MR/HR Feet No. Description Number
20 0.1 1000 565.0 r-R9 CRD-HCU West Area - Reactor RE-90-20 Building
21 0.1 1000 565.0 r-R13 CRD-HCU East Area - Reactor RE-90-21 Building
22 10 106 565.0 p-R12 TIP Room - Reactor Building RE-90-22
23 0.1 1000 565.0 p-R12 TIP Drive Area - Reactor Building RE-90-23
24 0.1 1000 519.0 u-R14 HPCI Room - Reactor Building RE-90-24
25 0.1 1000 519.0 u-R8 RHR West Room - Reactor RE-90-25 Building
26 0.1 1000 519.0 n-R8 Core Spray - RCIC Room - RE-90-26 Reactor Building
27 0.1 1000 519.0 n-R14 Core Spray Room - Reactor RE-90-27 Building
28 0.1 1000 519.0 u-R14 RHR East Room - Reactor RE-90-28 Building
29 0.1 1000 519.0 u-R14 Pressure Suppression Pool Area RE-90-29 Reactor Building
30 0.1 1000 664.0 p-R12 Fuel Storage Pool Area - RE-90-30 Reactor Building
31 0.1 1000 557.0 c-T6 Raw Cooling Water Pumps Area - RE-90-31 Turbine Building
BFN-18
Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS
Unit 3
Sheet 5
CHANNEL SENSOR AND CONVERTED LOCATION DETECTOR
Floor Approx TVA Station Range Elevation Col Inst No. MR/HR Feet No. Description Number
1 0.1 1000 664.0 px-R19 Fuel Storage Pool Area - Reactor RE-90-1 Building
2 0.1 1000 664.0 ux-R17 Service Floor Area - Reactor RE-90-2 Building
3 0.1 1000 639.0 p-R17 New Fuel Storage - Reactor RE-90-3 Building
4 0.1 1000 639.0 s-R17 Recirculating Pump M-G Set Area - RE-90-4 Reactor Building
5 0.1 1000 617.0 d-T14 Generator Operating Floor - RE-90-5 Turbine Building
6 0.1 1000 617.0 e-T12 RFP Operating Floor - Turbine RE-90-6 Turbine
7 0.1 1000 617.0 k-T15 Turbine Operating Floor - Turbine RE-90-7 Building
8 0.1 1000 617.0 p-R16 Main Control Room - RE-90-8
9 0.1 1000 621.25 t-R16 Cleanup System Area - Reactor RE-90-9 Building
10 0.1 1000 586.0 j-T12 Feedwater Heater Area - Turbine RE-90-10 Building
11 0.1 1000 586.0 b-T12 SJAE and SPE Area - Turbine RE-90-11 Building
12 0.1 1000 586.0 d-T12 Feedwater Heater Area - Turbine RE-90-12 Building
13 0.1 1000 593.0 p-R16 North Cleanup System Area - RE-90-13 Reactor Building
14 0.1 1000 593.0 s-R16 South Cleanup System Area - RE-90-14 Reactor Building
15 Not used
16 0.1 1000 557.0 c-T14 Hotwell Pump Area - Turbine RE-90-16 Building
17 0.1 1000 557.0 f-T14 Condenser Corridor - Turbine RE-90-17 Building BFN-18
Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS
Unit 3 (Continued)
Sheet 6
CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR
Floor Approx TVA Station Range Elevation Col Inst No. MR/HR Feet No. Description Number
18 0.1 1000 557.0 f-T12 Condensate Demineralizer Area - RE-90-18 Turbine Building
19 0.1 1000 565.0 j-T15 Outside Steam Line Cavity - RE-90-19 Turbine Building
20 0.1 1000 565.0 r-R16 CRD-HCU West Area - Reactor RE-90-20 Building
21 0.1 1000 565.0 r-R20 CRD-HCU East Area - Reactor RE-90-21 Building
22 10 106 565.0 p-R19 TIP Room - Reactor Building RE-90-22
23 0.1 1000 565.0 p-R19 TIP Drive Area - Reactor Building RE-90-23
24 0.1 1000 519.0 u-R21 HPCI Room - Reactor Building RE-90-24
25 0.1 1000 519.0 u-R15 RHR West Room - Reactor RE-90-25 Building
26 0.1 1000 519.0 n-R15 Core Spray - RCIC Room - RE-90-26 Reactor Building
27 0.1 1000 519.0 n-R21 Core Spray Room - Reactor RE-90-27 Building
28 0.1 1000 519.0 u-R21 RHR East Room - Reactor RE-90-28 Building
29 0.1 1000 519.0 u-R21 Pressure Suppression Pool Area - RE-90-29 Reactor Building
31 0.1 1000 557.0 c-T13 Raw Cooling Water Pumps - RE-90-31 Turbine Building
BFN-18
Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS
Radwaste Building
Sheet 7
CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR
Floor Approx TVA Station Range Elevation Col Inst No. MR/HR Feet No. Description Number
1 0.1 1000 546.0 wb-W6 Laundry Drain Tank RE-90-35
2 0.1 1000 546.0 wb-W3 Equipment Drain Sump Area RE-90-36
3 0.1 1000 565.0 wc-W6 Radwaste Control Room RE-90-37
4 0.1 1000 565.0 wa-W3 Access Corridor RE-90-38
5 0.1 1000 565.0 wc-W1 Waste Packaging Area RE-90-39
6 0.1 1000 578.0 wf-W3 Waste Sample Tank Area RE-90-40
7 0.1 1000 578.0 wb-W3 F.D. Sample Tank Area RE-90-41
8 0.1 1000 565.0 West Wall Radwaste Evaporator Building RE-90-42
NOTE: Indicators and trip units located on radwaste control panel. Annunciation on main control room panel.