ML21286A404
Text
BFN-18 Table 7.13-1 (Deleted by Amendment 13)
BFN-18 Table 7.13-2 LOCATIONS OF AREA RADIATION MONITORS Unit 1 Sheet 1 CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR Floor Approx TVA Station Range Elevation Col Inst No.
MR/HR Feet No.
Description Number 1
0.11000 664.0 px-R5 Fuel Storage Pool Area -
RE-90-1 Reactor Building 2
0.11000 664.0 ux-R3 Service Floor Area -
RE-90-2 Reactor Building 3
0.11000 639.0 p-R5 New Fuel Storage - Reactor RE-90-3 Building 4
0.11000 639.0 s-R5 Recirculating Pump MG Set Area -
RE-90-4 Reactor Building 5
0.11000 617.0 d-T4 Generator Operating Floor -
RE-90-5 Turbine Building 6
0.11000 617.0 e-T6 RFP Operating Floor -
RE-90-6 Turbine Building 7
0.11000 617.0 k-T3 Turbine Operating Floor -
RE-90-7 Turbine Building 8
0.11000 617.0 p-R7 Main Control Room RE-90-8 9
0.11000 621.25 t-R6 Cleanup System Area -
RE-90-9 Reactor Building 10 Not Used 11 0.11000 586.0 b-T6 SJAE and SPE Area -
RE-90-11 Turbine Building 12 0.11000 586.0 d-T6 Feedwater Heater Area -
RE-90-12 Turbine Building 13 0.11000 593.0 p-R6 North Cleanup System Area -
RE-90-13 Reactor Building 14 0.11000 593.0 s-R6 South Cleanup System Area -
RE-90-14 Reactor Building 15 0.11000 577.75 b-T2 Decontamination Room -
RE-90-15 Turbine Building 16 0.11000 557.0 c-T4 Hotwell Pump Area -
RE-90-16 Turbine Building
BFN-18 Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS Unit 1 (Continued)
Sheet 2 CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR Floor Approx TVA Station Range Elevation Col Inst No.
MR/HR Feet No.
Description Number 17 0.11000 557.0 f-T4 Condenser Corridor -
RE-90-17 Turbine Building 18 0.11000 557.0 f-T6 Condensate Demineralizer Area -
RE-90-18 Turbine Building 19 0.11000 565.0 j-T3 Outside Steam Line Cavity -
RE-90-19 Turbine Building 20 0.11000 565.0 r-R2 CRD-HCU West Area -
RE-90-20 Reactor Building 21 0.11000 565.0 r-R6 CRD-HCU East Area -
RE-90-21 Reactor Building 22 0106 565.0 p-R5 TIP Room - Reactor Building RE-90-22 23 0.11000 565.0 p-R5 TIP Drive Area - Reactor RE-90-23 Building 24 0.11000 519.0 u-R1 HPCI Room - Reactor Building RE-90-24 25 0.11000 519.0 u-R1 RHR West Room - Reactor Building RE-90-25 26 0.11000 519.0 n-R1 Core Spray - RCIC Room -
RE-90-26 Reactor Building 27 0.11000 519.0 n-R7 Core Spray Room - Reactor RE-90-27 Building 28 0.11000 519.0 u-R7 RHR East Room - Reactor Building RE-90-28 29 0.11000 519.0 u-R7 Pressure Suppression Pool Area RE-90-29 Reactor Building 32 0.11000 568.0 Stack Room RE-90-32
BFN-18 Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS Unit 2 Sheet 3 CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR Floor Approx TVA Station Range Elevation Col Inst No.
MR/HR Feet No.
Description Number 1
0.11000 664.0 px-R11 Fuel Storage Pool Area - Reactor RE-90-1 Building 2
0.11000 664.0 ux-R10 Service Floor Area - Reactor RE-90-2 Building 3
0.11000 639.0 p-R10 New Fuel Storage - Reactor RE-90-3 Building 4
0.11000 639.0 s-R10 Recirculating Pump M-G Set Area -
RE-90-4 Reactor Building 5
0.11000 617.0 d-T8 Generator Operating Floor -
RE-90-5 Turbine Building 6
0.11000 617.0 e-T6 RFP Operating Floor - Turbine RE-90-6 Building 7
0.11000 617.0 k-T9 Turbine Operating Floor - Turbine RE-90-7 Building 8
Not Used 9
0.11000 621.25 t-R9 Cleanup System Area - Reactor RE-90-9 Building 10 0.11000 586.0 j-T6 Feedwater Heater Area - Turbine RE-90-10 Building 11 Not Used 12 Not Used 13 0.11000 593.0 p-R9 North Cleanup System Area -
RE-90-13 Reactor Building 14 0.11000 593.0 s-R9 South Cleanup System Area -
RE-90-14 Reactor Building 15 Not Used 16 0.11000 557.0 c-T8 Hotwell Pump Area - Turbine RE-90-16 Building 17 0.11000 557.0 f-T8 Condenser Corridor - Turbine RE-90-17 Building 18 Not used 19 0.11000 565.0 j-T9 Outside Steam Line Cavity -
RE-90-19 Turbine Building
BFN-18 Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS Unit 2 (Continued)
Sheet 4 CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR Floor Approx TVA Station Range Elevation Col Inst No.
MR/HR Feet No.
Description Number 20 0.11000 565.0 r-R9 CRD-HCU West Area - Reactor RE-90-20 Building 21 0.11000 565.0 r-R13 CRD-HCU East Area - Reactor RE-90-21 Building 22 10106 565.0 p-R12 TIP Room - Reactor Building RE-90-22 23 0.11000 565.0 p-R12 TIP Drive Area - Reactor Building RE-90-23 24 0.11000 519.0 u-R14 HPCI Room - Reactor Building RE-90-24 25 0.11000 519.0 u-R8 RHR West Room - Reactor RE-90-25 Building 26 0.11000 519.0 n-R8 Core Spray - RCIC Room -
RE-90-26 Reactor Building 27 0.11000 519.0 n-R14 Core Spray Room - Reactor RE-90-27 Building 28 0.11000 519.0 u-R14 RHR East Room - Reactor RE-90-28 Building 29 0.11000 519.0 u-R14 Pressure Suppression Pool Area RE-90-29 Reactor Building 30 0.11000 664.0 p-R12 Fuel Storage Pool Area -
RE-90-30 Reactor Building 31 0.11000 557.0 c-T6 Raw Cooling Water Pumps Area -
RE-90-31 Turbine Building
BFN-18 Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS Unit 3 Sheet 5 CHANNEL SENSOR AND CONVERTED LOCATION DETECTOR Floor Approx TVA Station Range Elevation Col Inst No.
MR/HR Feet No.
Description Number 1
0.11000 664.0 px-R19 Fuel Storage Pool Area - Reactor RE-90-1 Building 2
0.11000 664.0 ux-R17 Service Floor Area - Reactor RE-90-2 Building 3
0.11000 639.0 p-R17 New Fuel Storage - Reactor RE-90-3 Building 4
0.11000 639.0 s-R17 Recirculating Pump M-G Set Area -
RE-90-4 Reactor Building 5
0.11000 617.0 d-T14 Generator Operating Floor -
RE-90-5 Turbine Building 6
0.11000 617.0 e-T12 RFP Operating Floor - Turbine RE-90-6 Turbine 7
0.11000 617.0 k-T15 Turbine Operating Floor - Turbine RE-90-7 Building 8
0.11000 617.0 p-R16 Main Control Room -
RE-90-8 9
0.11000 621.25 t-R16 Cleanup System Area - Reactor RE-90-9 Building 10 0.11000 586.0 j-T12 Feedwater Heater Area - Turbine RE-90-10 Building 11 0.11000 586.0 b-T12 SJAE and SPE Area - Turbine RE-90-11 Building 12 0.11000 586.0 d-T12 Feedwater Heater Area - Turbine RE-90-12 Building 13 0.11000 593.0 p-R16 North Cleanup System Area -
RE-90-13 Reactor Building 14 0.11000 593.0 s-R16 South Cleanup System Area -
RE-90-14 Reactor Building 15 Not used 16 0.11000 557.0 c-T14 Hotwell Pump Area - Turbine RE-90-16 Building 17 0.11000 557.0 f-T14 Condenser Corridor - Turbine RE-90-17 Building
BFN-18 Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS Unit 3 (Continued)
Sheet 6 CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR Floor Approx TVA Station Range Elevation Col Inst No.
MR/HR Feet No.
Description Number 18 0.11000 557.0 f-T12 Condensate Demineralizer Area -
RE-90-18 Turbine Building 19 0.11000 565.0 j-T15 Outside Steam Line Cavity -
RE-90-19 Turbine Building 20 0.11000 565.0 r-R16 CRD-HCU West Area - Reactor RE-90-20 Building 21 0.11000 565.0 r-R20 CRD-HCU East Area - Reactor RE-90-21 Building 22 10106 565.0 p-R19 TIP Room - Reactor Building RE-90-22 23 0.11000 565.0 p-R19 TIP Drive Area - Reactor Building RE-90-23 24 0.11000 519.0 u-R21 HPCI Room - Reactor Building RE-90-24 25 0.11000 519.0 u-R15 RHR West Room - Reactor RE-90-25 Building 26 0.11000 519.0 n-R15 Core Spray - RCIC Room -
RE-90-26 Reactor Building 27 0.11000 519.0 n-R21 Core Spray Room - Reactor RE-90-27 Building 28 0.11000 519.0 u-R21 RHR East Room - Reactor RE-90-28 Building 29 0.11000 519.0 u-R21 Pressure Suppression Pool Area -
RE-90-29 Reactor Building 31 0.11000 557.0 c-T13 Raw Cooling Water Pumps -
RE-90-31 Turbine Building
BFN-18 Table 7.13-2 (Continued)
LOCATIONS OF AREA RADIATION MONITORS Radwaste Building Sheet 7 CHANNEL SENSOR AND CONVERTER LOCATION DETECTOR Floor Approx TVA Station Range Elevation Col Inst No.
MR/HR Feet No.
Description Number 1
0.11000 546.0 wb-W6 Laundry Drain Tank RE-90-35 2
0.11000 546.0 wb-W3 Equipment Drain Sump Area RE-90-36 3
0.11000 565.0 wc-W6 Radwaste Control Room RE-90-37 4
0.11000 565.0 wa-W3 Access Corridor RE-90-38 5
0.11000 565.0 wc-W1 Waste Packaging Area RE-90-39 6
0.11000 578.0 wf-W3 Waste Sample Tank Area RE-90-40 7
0.11000 578.0 wb-W3 F.D. Sample Tank Area RE-90-41 8
0.11000 565.0 West Wall Radwaste Evaporator Building RE-90-42 NOTE: Indicators and trip units located on radwaste control panel. Annunciation on main control room panel.