A 14 SYSTEM DATA NO SCFM PSIG TEMP BY REMARKS 1
990 120 110 2 990 0
95 INLET 3
DELETED 4
600 100 110 PAR I.A.
5 7 0 0 1 0 0 110 PAR S. A.
6 150 100 110 PAR SEE NOTE 4 7
5 0 l 0 0 110 PAR 8
250 100 110 PAR 9
3 0 0 l 0 0 110 PAR l 0 3 3 0 l 0 0 110 PAR SEE NOTE 2 VALVE NO B-816 GRID. LDC VALVE NO DWG THIS DWG 13 B-816 B 12636
-078 D-1 D-1 12691 12692
-010 12637
-056
-009 12638
-055 D-1 12693 12639
-053 D-2 12694
-008 12640
-052 D-2 12695 12641
-051 D-3 12696
-0 2 0 12642
-049 D-3 12697
-020 12643
-057 C-3 12698
-100 12644
-0 5 0 C-3 12699
-099 12645
-041 C-3 12646
-042 C-3 22600
-105 12647
-04 3 C-3 C 12648
-044 C-4 C-4 22603 22604
-018 12649
-045 12650
-045 C-4 22605 12651
-040 B-2 22606 12652
-039 B-2 22607 12653
-038 B-2 22608
-017 12654
-037 B-2 22609
-017 12655
-036 B-2 22610
-016 12656
-047 B-3 22611
-016 12657 B-3 22612
-015 12658
-035 B-3 22613 12659
-026 D-4 22614
-002 12660 12661
-028
-102 D-4 C-4 22615 22616 12662
-103 C-4 22617
-064 12663
-098 D-4 22618 12664 B-3 22619
-065 12665
-024 B-3 22620
-066 12666
-025 B-3 22621
-066 12667
-023 B-3 22622
-022 12668 B-3 22623
-021 12669
-059 A-4 22624 12670
-061 A-4 22625 12671 A-4 22626
-071 E 12672 A-4 A-4 22627 22628
-072 12673
-062
-070 12674
-063 A-4 22629 12675
-058 B-3 22630
-069 12676 B-3 22631
-068 12677
-058 B-3 22632
-067 12678
-058 B-3 22633
-067 12679
-077 B-4 22634
-075 12680
-014 B-6 22635
-073 12681
-012 B-6 12682
- 011 B-7 22637
-034 12683 B-7 52614
-103 F 12684
-013 B-7 C-6 72629
-109 G
H J
K 12685
-012 12686
- 0 0 1 C-7 12687
- 0 0 1 C-7 12688
- 0 0 1 C-7 12689
- 0 0 1 C-7 12690
-010 B-11 2
- 2. STERILE WATER TANK REQUIRES 136 SCFM FOR 15 MIN/8 HOURS & MIXED BED DEMINERALIZERS REQUIRE 330 SCFM FOR 30 MIN/24 HOURS.
- 3. PIPING AND COMPONENTS ARE NON-NUCLEAR. EXCEPT AS NOTED.
- 4. REACTOR BLDG BACKUP INSTRUMENT AIR SUPPLY, REQUIRED ONLY WHEN REACTOR BLDG INSTRUMENT AIR SYSTEM FAILS.
- 5. ITEMS DESIGNATED WITH lfl ARE FURNISHED BY THE COMPRESSOR SUPPLIER.
- 6. FOR COMPONENTS CLASSIFIED AS QR, SEE TRP-28.
- 7. THIS HOSE CONNECTION IS USED TO CONNECT A PRESSURE SENSING LINE TO THE TEMPORARY DIESEL AIR COMPRESSOR FOR PRESSURE CONTROL.
H-5
< E-911-104 FD 120 110 135 290 (11/.
100 120 110 135 150
<11/.
203 PAR P
HY-
!+
1-----1---+------'-----J DRG BY CHKD NORMAL UPSET DESIGN DATA GRID. LDC THIS DWG B-11 B-11 C-11 C-11 C-11 B-7 B-7 B-7 B-8 B-8 A-6 A-6 A-6 A-7 A-7 A-7 A-7 A-7 A-7 A-8 A-8 A-8 A-8 A-6 A-6 A-7 A-7 A-7 A-7 A-9 A-9 A-10 A-8 A-9 A-9 A-9 A-9 A-9 A-10 A-10 A-10 A-11 A-9 C-1 C-4 G-1 REMARKS 12 4"
ROe-11
/
12692-IA ROe-11 12695-IA '--
TO ATMOSPHERE 5"
11 ABOVE ROe-14 l ',;
22634-IA '
EL.485'-0" o
10 I"
ROe-13 22624-IA \\o ROe-11 12691-I A'-.; 0 0
ROe-11 12690-IA
'1.
t;:
3/.
ti.'
I )ogt}_:_' -Cl--,-----1____.'.'=------*.:_..::r '
,,,,1 ROe-11,/, 0 12694-IA ABOVE 374'-0"
'l 2
0 \\
ROe-11 12693-IA
/VENTED COLLECTION PIPE
~~
I" 2629A-IA 2714A-IA y
114 "= l'-0 "
0' 5'
10' 15' 20' X
LO LO 9
3" STM. GEN.
BLOWDOWN SAMPLE PANEL TO FUTURE UNITS 8
161X 151X ROe-12 22602-IAIV-Zll 7
I ROe-14 22620-IA 6
ABOVE 463'-0"
\\
ROe-14 ROe-14 22619-19;22618-7 ROe-14 22617-IA ROe-1 Z /
a 12689-IA
/
~
12688-IA 0
0 0
ROe-14 22616-IA ROe-11
/ 12680-IA 0
2" ABOVE 397'-0' AND 388'-0" 111 111 ROe-14 o /
12685-IA
\\
~
ROe-14
~
I Z 68 6-I A 12687-IA 3"
'------,~ 4" l55X 4"
151X 156X 151X R ECR50464B.,,,qr NOTE 7 ECR50601 XTP-5018-IA -
XVA72647-]A Al TO FD I
DIESEL AIR ~
ROa-9 2624-IA MRF-21014 2"
31..;
'------'I ---'---'
-.,.-L--'
12677-IA ROe-14 12678-IA 2"
2 ROe-15 2612-IA \\
0 ROe-12 IPX-8356B-HR-IA'-- 0 ROe-14 12667-IA ROe-14 12666-IA ROe-14 12665-IA ROe-14 o /12664-IA ROe-12 IPX-8352B-HR-IA 2" ROe-15 o j 2611-IA Z"
7 ROe-14 12655-IA ROe-14 ROe-l 4 12652-IA (FE\\
i~
I 0
~
v 1
ROe-12 IPX-8356A-HR-IA ROe-12 IPX-8352A-HR-IA J-3
-274 I.A.J-3 3"
1265 4 - li::A;i,-::;, ;R__,_.O~e"...-_.cl :c4 12651-IA ~1---L--__J 2"
3" 11 11, 11 2
I.A.
/ROe-14 2" 12653-IA
<I RNb-20 2633-IA L.O.
<I
~
Cr'.
- r:
N
<I OJ
'<j-ID C"l D
OJ Cr'.
X (L
ROe-14 3"
Jl.1;;
=----t@:]
faoe-14 22637-IA 12 6 3 8 - I A
:--C@'.J 3"
111 ROe-14 12637-IA
--=.=-t@:J 111 ECR50538 XVA02670-IA
~2634-IA 4
Pl 8326 ECR50538 IPI08326-HR-IA I
I 0-I ECR50538 RNb-20
- XDR0004A A
/
2603A-IA j IOEWPOINTl
.L 'c:DNTROL I I~
\\~~~~2A~IA 1-----3_" ____
---<; I L._ ___ _J I
PANE I,l 151x
~
'---I 155X
~117 6~~J~ 'A" L __ 1:_J ~f--.--------1'..,_
S-20-0692 I
________ _j R
0
!55:
3" 0
3" 3"
'<j-1.D <I
'<j- -
<Sl '
LD LD ccN u I.fl N
155X 1/2"- 2505X
~
3" 0
~
ECR50538 1
ECR50538 RNb-20 XVA72629-11/
ECR50464B XTP-5005A-IA I 1EWP 1NT 1- --'coNTRDLI I 151x 3"
I ___ _J ___ XDR0004~~ \\A XO 155X 3"
_J I
1
- g 314 '
'-------..._l-------1----_,__ __
___J~
SA/IA L PANE1:_ J I~ 1-----------..,_
RNb-20 t
~
I AIR DRYER 'B"
- ~;
- ii
- ",ca,e~,o
+'
,~~,a~asss _ _____ J ~
'l ECR50464B 1/2"- 2505X 1/ XTP-5019-IA G-5
< E-911-104 FD G-5 E-911-104 FD ECR50464B r
T -----f y
DRAWING LEGIBILITY CLASS 1 ESSENTIAL FSAR Figure 9.3-2 SOUTH CAROLINA ELECTRIC & GAS COMPANY SCE&G CAD ENHANCED VIRGIL C. SUMMER NUCLEAR STATION 41 li/!4/2!12 JTS REVISED PER ECR-50577 40 07/07/2010 RHM 46 04/09/2019 CMS 45 01/23/2019 CMS 44 09/06/101 JMR 43 !6/14/1017 JTS 42 03/04/1013 DDJ NO.
DATE BY REVISED PER ECR-50538 REVISED PER ECR-72491 REVISED PER ECR-72479 REVISED PER ECR-72429 REVISED PER ECR-72257 REVISED PER ECR-50538 REVISION MGR KW MGR chk chk AME RHM MGR LS JCB AJL CB AME LS LE CKO.BY APPROVAL PIPING SYSTEM FLOW DIAGRAM INSTRUMENT AIR 6
DESIGN ENGINEERING SCE&G A SCANA COMP/I"'
v.c. SUMMER NUCLEAR STATION JENl(]NSVILLE.s.c.
MADE CHECKED LE APPROVAL I.
- 2.
- 3.
ACI RHM RBS NO SCALE D-302-271 46 DRAWING NUMBER SHT. NUMBER REV A
B C
D F
G H
J K