17 l20YAC INSTR. MAIN DIST. PNL. !FA APN!FA-EM, CB-H ROO POSITION INl. PNL. !FCI APN1FC1-EM, !8-0 25 16 4B0Y ~TOR CONTROi. CENTER XMC!DA2X-ES UNIT T 16IJL
) 100AF 711AT 1m~
25KVA 480-120V 10 VITAL SYSTEM TRANSF.
ESF, !FA XTF!FA-EM 2/C-350MCM 400A BUS II 12
) 100AF 15AT 13
) 100AF 15AT 15 14
) 100AF 15AT 2/C-10
---1 2/C-10 2/C-10 FU28 I 30A 1
_<;;:>J 2/C*lll IA-ASSOC.I
- IA*ASSOCJ
- IA-ASSOC.I BACK-UP FEED TO XPN7005-XI BACK-UP FEED TO XPN7006-XI BACK-UP FEED TO XPN6001*BP BACK-UP FEED TO BOP INSTR. CAB, 'A' XPN6004*BP TO APN!FB-EM OWG. E-206-062 SH.2
~*
18-ASSOC.l 2/C-4/0
) 225AF M ~225AF SEE NOTE 9 'J 12ilYAC INSTR.
PAIEL *1 APll5901-EV, CB*H 225A BUS 13 +
17 +
02 T) ll!IIAF 04 ) llilllAF 05 ) lfJllAF 40AT 40AT 20AT 15 02
)
14 16
) ll!IIAF 20AT 2/C-10 RAO. MON. SYS.
INSTR. l'tl..
XCP6200-RM VIA XPN5253-EM 225A BUS
) l00AF 15AT 04
) 108AF 15AT
- 19 31 05 13 CHANNEL A 225AF 23 225AF 22
) 150AT
) I50AT
)IIIHAF SEE NOTE 20 SEE NOTE 2il 50AT 2/C-1/0
)
) 180AF 15AT 06 ffi1
~I
&11 if L'.
X 2/C-2 I
FU! I 50A 1
~I 2/C-1/0 2/C-2 IA-ASSOC.I
) ll!llAF 25AT FlA.L LENGTH CRl)1 C()lT, PWR. CAB.
XCA0001A-cll 07
) 1BBAF 15AT 08 10
) 1110AF 15AT 12 2/C*B
) 100AF 15AT 10
) 100AF 20AT 11 UNIT T 14 All1 )
I 10 9
480Y MOTOR CONTROL CENTER XMC!DA2Y-ES UNIT T UNIT T 6AB~ ) Illl!AF GAB~ ) ll!IIAF 30AT 30AT 3/C-6 3/C-6 NORMAL SOURCE AllERNAlE SOURCE
~-------'-48=0VccAce~=.,iacc,H,=60i'-"Z'---+-------
~
~120V 7 AC,1PH,60HZ 10KVA STAL II.JS U.P.S.
~15901-EV (1115 1<5)
BACKUP SOURCE TO 125\\0C DPN1HA-ED @--
Di<<:. E-206- 062 SH. J 150A
. - L:=J_cn, PRE-CHARCE
-l
)40A UPS
~
~CTIFIER L~60A
) ~2~A
'._".'.)
IH O-f50V
'160A STATICO S'MTCHT ltr---i II 12
):f
) 100AF 20AT 13
) l00AF 15AT T
o-2oov C<'
55-65HZ (iv 0-150A ~ )--
14
' 250A NON-AUTO UPS 001PUT
.,___~_2-1/c-2/o
)225AF 27 16
)100AF 15AT 100A
~
)::f DA TO APN5907-EV THIS DWG. f 21c-2
)-:f.
21 17
) 100AF l5AT 8
CHANNEL 18 1q 2ll
)100AF 15AT
)
)IBBAF 20AT 7
6 5
4 APN5901-EV 2 - 20AT 2
- 25AT 1-30AT I* 225AT 3
7 SPACES-I00AF-2 POLE 2
SPARE BREAKERS IN PANELS APN5902-EV 2
- 20AT I* 30AT 2
- 225AT 13 SPACES-100AF-2 POLE APNIFA-EM I - 30AT I - 70AT 1-100AT 1-l25AT 2
- l50AT l
6 SPACES-I00AF-2 POLE 4 SPACES*225AF*2 POLE APll5907*EV APN!FCHM 10 - 151\\T 2
- 15AT 2 - 20AT 2 - 20AT 1-30AT 1-30AT 11 SPACES 1
- 35AT
~ORM;SOUR;
t-AllERNA=1E~sou=R7.CE~*-~~-~----_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-_-__ -,----2_-_5_0_A_r ______,
D--)
48OV~3PH,60iZ I
120VAC,1PH,6OHZ
~--- -----~~----------+,--~
10<VA STAL BUS U.P.S.
~15902-EV (1MS-37-1<5)
BACKUP SOORCE TO 125\\llC 150A DPN1HA-ED c >--+--- -,-~:::i*nr
~
. E-206-Cli2 SH. J Pll[-CHARGE 12BVAC INSTR,
)
PANEL "2 APN5902*EV,CB*M 29 01 82 04 05 El *
.:I
) 108/lf 20AT
) 100AF 15AT
) 100AF 15AT
) 100AF 15AT
'~ l
- 110A 1
'yTy*.
11;!1 RECTIFER Q160A
--~
~' 0-;.2~OA
...~)
- , 25DA
' NON-AUTO I UPS OOTPUT 2-1/C-2/0
)225AF 25 07 08
) IIIBAF 15AT
) IOOAF 15AT
)
21 2251\\ BUS 09 10 12 13 15
) 100AF l5AT
) !01!AF 15AT
)100AF 20AT
) 100AF l5AT 0
0 2/C-I0 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 2/C-I0 2/C-10 2/C-10 2/C-B 2/C-I0 2/C-I0 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 2/C-I0 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 2/C-10 3/C-4 3/C-4 ffir ----- ---1
~I FU!
FU2 I t;j I 60A 60A I
ifl...'.
0
__ O_J 3/C-4 3/C-4 ROD POSITION ROD POSITION IND. PNL. I
!NO. PNL. 2 XPN7060-CR XPN7061-CR 2/C-16 ROO POS. IND.
PLC XPN6058 &
MCB DISPLAYS IZM0I2il0 & IZM01201
_____________________ ______ ______________ _ ____ J 120VAC INSTR, PANEL '7 APM5'l07-EV, CB-M 14 T)l00AF 15AT 17T) 1_
20AT 225A BUS 2s T) 1_
20AT TO APN5'101-EV THIS OWG.
g INCORE THCPLE.
ANALOG ISL TR.
CAB.A XCP6231A*IC 2/C-2
)225AF 21+
32 ) 101!AF 15AT NIS CHANNEL I CONT, PWR.
XCP7071-Nl 2/C-12 2/C-10 2/C-10 2/C-10 2/C-12
~r:: ---1
- !;1 I
~I 3A I
~L'. ___ I 2/C-12 ISOLATION RELAY PANEL XPN54B4-RH BOP INSTR. CAB.
TRAIN 'A' XPN600I-BP ltr: ---,
181 FU2A 1 NI 30A 1 IL'. <2.1 2/C-10
- IA-ASSOC.>
PROCESS RACK CONTROL GROUP 1 llPN7005-XI BOP INSTR.
CAB. 'A' XPN6004*BP
- l'r
- ---I
~I FU! I 151\\
I if L'.
_q__l 2/C-12 ISOLATION RELAY PANEL XPN5477*RH l/4":;; t'-0 "
0' NIS CONT. BO.
SOI.ID STATE CHANNEL I INSTR. BUS I PROTECTION INSTR. PWR.
XPN7110-MC SYS. CHAN. I XCP7071*Nl TRAIN 'A' XPN7010-SG 5*
10' 15' SOLID STATE PROTECTION SYS. CHAN. I TRAJN 'B' XPN702il-SG 20' ltr ffil
&11 i~
2/C-10 CA*ASSOC.l TRANSMITTER PROCESS RACK POWER SUPPLY PROTECTION CAB. CHANNEL A SET I APN5912A-EV XPN701ill-XI FU2B 1 2ilA I
~I 2/C-10 CA-ASSOC,)
IE AUX.
REACTOR REACTOR HVAC NSS ESF LOADING RELAY RACK PROTECTION VESSEL LEVEL CONT. BO.
AUX.RELAY SEllUENCE XPN5303-ES UNDERFREO.
CAB. RIGHT XCP62l0-AH RACK 1 CIX'IT. PNL.
& UNOERVOLT.
XPN7248*RC IXPN7170-AHI XPN703HiG TRAIN 1A1 RELAY PNL. I XPN6020*SG XPN6BlHS ffir
.i,I ;,
XL'.
2/C-10 CA-ASSOC.I AUX.
REACTOR SAFEGUARDS CORE COOLIIJG CAB. TRAIN 'A' MONITOR XPN7034-SG UNIT A XPN7218-RC w
NI AMP.
i SORCE &
INT MO.RANGE CHANNEL I XPN7303-NI NI AMP.
SOURCE &
INTMD.RANGE CHANNEL II XPN731l4*NI CONT. BO.
INSTR. BUS 2 CHANNEL D XPN7113-MC NIS CHilNNEL II CONT. PWR.
XCP7072-NI NIS CHANNEL II INSTR. PWR.
XCP7072*NI ffir ---1 ffl I FU! I t;j I 20A I
ii: L'.
~I 2/C-10
- CO*ASSOCJ TRANSMITTER POWER SUPPLY CAB.CHANNEL D APN591ZC-EV SOLID STATE PROTECTION SYS. CHAN. II TRAIN 'A' XPN7010-SG SOLID STATE PROTECTION SYS. TEST PNL.
TRAIN 'A' XPN70U-SG SOLID STATE PROTECTION SYS. CHAN. II TRAIN 'B' XPN7020-SG PROCESS RACK PROTECTION SET II XPN7002-XI ltr ---1 ffil FU2A 1
t;jl 30A 1
ii"L'. ~I 2/C-10 ID-ASSOC.I PROCESS RACK CONTROL GROUP 2 XPN7006*XI REACTOR PROTECTION UNOERFREO.
& UNDERVOLT.
RELAY PNL. II XPN60!2*ES L-------------------------------- ----- -- ------------- -------- -------------------- - ------------- --- ---- --- -------------
- NOTES,
!. t, - BREAKERS WITH AUXILIARY CONTACTS FOR INOICATl()l IN CONTROL ROOM.
- 2. M
- MECHANICALLY INTERLOCl<ED BREAKERS, 225AF BREAKERS SHCWN WITHOUT TRIP SETTINGS ARE WITHOUT TRIP ELEMENTS.
3.IHSTRUMENTS SHOWN ARE LOCATED OR MOUNTED ON ASSOCIATED EUIPHENT UNLESS OTHERWISE NOTED.
- 4. * - INDICATES ITEMS OR AREAS THAT ARE NOT NIUEAR SAFETY RELATED INNS!.
- 5. ACB BREAKER RATINGS SHOWN ARE COR. RATINGS WITH 6l!IJI\\F.
- 6. AVAILABLE SHORT CIACUIT CURRENT AT BUS !HA OR lHB IS 20,600A AT l25VOC.
- 7. MECHANICALLY INTERLOCKED BREAKERS ARE FOR USE AS DISCONNECT ONLY ANO WILL NOT BE USED FCll PROTECTION COORDINATION *
- 8. TIE BREAKERS ARE INTERLOCKED TO ALLOW ONLY TIE TWO BREAKERS ASSOCIATED WITH CHANIEL 'A' OR Tl£ TWO BIBKERS ASSOCIATED WITH CHAlff:L 'B' TO CLOSE AT ONE TIME..
9, Tl£ BREAKERS ARE HECHANICALL Y INTERLOCKED TO ALLOW ()lL Y ONE BREAKER CLOSED AT A TIME.
- 10. - INDICATES METERING IN THE ESF POWER SYSTEM WHICH IS 'NNS'. CIRCUITS TO THIS METEROO, FROM TIE NEAREST PROTECTIVE DEVICE, WILL BE RlN AS ASSOCIATED CXA, XB, DR XCl.
- 11. <=> - ISOLATION DEVICE, CLASS IE TO NON-CLASS !E.
- 12. 0 - REACTOR BUILDOO PENETRATION PROTECTION DEVICE.
- 13. USE BUSSMAN LIMITRON OR GO.Ul-CHASE SHAWMUT FORM 60IJ FUSES FOR CLASS IE ISOLATION FUSES ANO PENETRATION PROTECTION FUSES ON ALL PANELS, EXCEPT FOR FEEDS FROM PANELS APN5901, 2, 3, 4, 7, ANO B WHICH REQUIRE GOULO*CHilSE SHAWMUT FORM 101 FUSES.
- 14. BREAKER TD BE SET AT 'HIGH' TRIP.
- 15.
DELETED
- 16.
DELETED
- 17.
DELETED
- 18. PANELS REDUIRE HIGH INTERRUPTING TYPE 'FH' BREAKERS,
- 20. BREAKER TO BE SET AT 'HIGH' TRIP.
TltS IS A NUCLEAR SAFETY RELATED DRAWING LEGe'-ITY DOCUt.lENT. NO DEVIATION SHP4..L BE CLASS 1 INITIATED OR PERFORMED WITHOUT PRIOR tcs"c"'e*'"'G,....,.CAD=-=-eN""H,-AN-C,-E-jD DOCUMENTATION AND WRITTEN APPROVAL ~ -----~
41 I 11 11 ***
REVISED PER ECR-50113 JRO 40.....
MAB REVISED PER ECR-50538 HJM GSK
,. 11211*
JMR REVISED PER ECR-5O686 MGR RH
,..,,,.,.. RHM RE:VtSEO PER CGSS-~8-O1J2 MGR JEG 37 "'""'
JMH REVISED PER MRF-218"44 DVW RCB
~- ""
8Y REVISION CICD, IIY,..,,,.,,,._
FSAR Figure 8.3-1 S0JTH CIIRO..INA B..ECTRIC
- llAS CCN'Hff VIROIL C. st..M£R NJCLEAR STATIOO GILBERT ASSOCIATES, INC.
ELEC. ONE LINE AND RELAY DIAGRAM ENGINEERED SAFETY FEAT~ES VITAL N::, SYS.
Q DESIGN ENGINEERING
,. __ V.C.SI..Mll!lt NlJOLENt 5T,.TIJN JMH DVW RCS E-206-062 1
41 OIWl'INU ~ llffT.--