1 to Updated Final Safety Analysis Report, Chapter 10, Figure 10.2-2, Control Diagram Turbine Stop Valve
ML21209A417
Person / Time
Site: Summer 
Issue date: 04/30/2021
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21209A581 List: ... further results
References
21-167
Download: ML21209A417 (1)


Text

xvc;-2a0qA-MS MAIN STOP VALVE

( SV-1)

XVT-73001-TB r.l XVT-73002-TB NOTE I XVT-73003-TB IPT-5608-HRI

  • TB IPT-5608*HR2-TB STEAM INLET* - -- -- -

q90 PSIA BEFORE SEAT DRAIN.

REFER TO MOISTURE

"'i----**------REMOVAL ANO 542'F XVX*22825A SOLENOIO-OPERATED-.....i TEST VALVE STEM SEAL DISK DUMP VALVE ORIFICE*

0 109" DIA

$HUT-OFF VALVE* SET TO OPEN AT 500 l'.S.I.C.

XVM*22823A L..J EXTRACTION DIAGRAM

__...,_ STEAM OUTLET TO CONTROL VALVES REFER TO DIAGRAM OF

-** STEAM SEAL PIPING XVX*22824A SV!*FA ORIFICE 0.111Jq" DIA.

SOLENOID-OPERATED, FAST ACTING VALVE a._..,. ~

COMPUTER Y20010

~

SSPS-A, B SVl*L Tl XVG-2s0qs-MS MAIN STOP VALVE (SV-2)

$$$$$0GNSPEC$$$$$$$$$$$$$$$$$$$$$$$$$$$$

$$USERNAME$$$$$$$SYTIME$$$$$$

STEAM INLET* - -- -- -

q90 PSIA 11):J,~jli.,J__ FOR PRE-WARMING ONLY 11 ~IIV BEFORE SEAT DRAIN

  • REFER TO MOISTURE 542"F 3 COIL SERVO VALVE XVM-22825B SV2-SVI DISK DUMP VALVE SHUT-OFF VALVE*

SET TO OPEN AT isoo P. s.1.0.

XVM-228238 REMOVAL ANO

-M

--EXTRACTION DIAGRAM

___ -.. ___...,_STEAM OUTLET TO CONTROL VALVES REFER TO DIAGRAM OF

--- STEAM SEAL PIPING XVX*22824B SV2-FA SOLENOID-OPERATED, FAST-ACTING VALVE

~

,..==-::, COMPUTER Y2002D

~

SSPS*A, B SV2-L T2 SV2*LT1 LEGEND OIL OR HYDRAULIC FLUID LINE SV2-L T3 xvc;-2s0qc-Ms MAIN STOP VALVE xvc;-2a0qo-Ms MAIN STOP VALVE ELECTRICAL <DUAL OR

--'00' MUL TIPLE LEADl I SV-3)

STEAM INLET- - -- -

II qg0 PSIA

~

542.F XVX-22825C STEM SEAL DISK DUMP VALVE ORIFICE*

0 109" DIA SHUT-OFF VALVE* SET TO OPEN AT 500 P.S.I.G.

XVM-22823C BEFORE SEAT DRAIN.

REFER TO MOISTURE

______ REMOVAL ANO EXTRACTION DIAGRAM

_______...., STEAM OUTLET TO CONTROL VALVES REFER TO DIAGRAM OF

_.,.._ STEAM SEAL PIPING XVX-22824C SV3-FA ORIFICE 0.109" DIA.

SOLENOID-OPERATED, fAST ACTING VALVE 0'

5*

10'

~~ ~COMPUTER Y2003D

~SSPS*A, B V3*L I 15' I SV-4)

STEAM INLET- - -- -

qa0 PSIA 542"F SOLENOID-OPERATED TEST VALVE XVX-228250 SV4*TS STEM SEAL DISK DUMP VALVE ORIFICE*

0 109" DIA SHUT-OFF VALVE* SET TO OPEN AT 500 P.S.I.G.

XVM-228230 BEFORE SEAT DRAIN.

REFER TO MOISTURE

______ REMOVAL AND EXTRACTION DIAGRAM

_______...,_STEAM OUTLET TO CONTROL VALVE$

REFER TO DIAGRAM OF

_ _,.,,..STEAM SEAL PIPING XVX-228240 SV4*FA ORIFICE 0.109" DIA.

SOLENOID-OPERATED, FAST ACTING VALVE

~

r.::=::-::, COMPUTER Y2004O

~

SSPS*A, B SV4*L Tl 5

4 3

2 l

6 NO.

'l/

RHM 5112/11 DOJ 115/811 RHM ll3/31/'l8 JTS lll!W'l6 AVN 2/'!j/J!j JMR TE BY AIR LINE STEAM LINE COMPONENTS SHOWN IN PHANTOM -

BY PURCHASER 1600 P.S.I.G. HYDRAULIC FLUID TO OPERATING DEVICES

.0 - 5 P.S.I.G. HYDRAULIC FLUID DRAIN 1600 P.S.!.G. HYDRAULIC FLUID TRIP SYSTEM 1600 P.S.I.G. HYDRAULIC FLUID TO JET OPERATING SIGNAL FROM ELECTRO-HYDRAULIC

~

CONTROL CABINET

~

vv ----

NOTES, FEEDBACK SIGNAL TO ELECTRO-HYDRAULIC CONTROL CABINET I, SEE D-302-012 FOR FLOW DRAWING LOCATION.

SElTING INSTRUClfONS FOR CONTROL $YST£M LlkE-UP OIAGRAJi,4 SEE OWG NO f2$D2H6 FOR MAIN $TEAM VALVE SWITCH

&ETTfNG INSTRUC::TlONS SE£ OWG NO 254A9066 FOR SWITCH SOX DRAWINC SEE OWG NO 1,4£52;) ~ND 75:u1z5 REVISED PER ECR-505qz REVISED PER ECR505qze REVISED PER CGSS-00-0005 REVISED PER CGSS-q?-0662 REVISED PER CGSS-96-0571 REVISED PER ECR* 72833 R/N 12*013 REVISION MGR MGR MGR MGR MGR MGR CKD.BY GM AME JEG LEK JMW TMH t.E APPROVAL DRAWING LEGIBILITY CLASS 1 FSAR FIGURE 10.2-2 STOP VALVE 251R45Pl DESIGN ENGINEERING V. C. Sl.ttMER NUCLEAR STATION JENKINSVILLE C,

CHECKED LE APPROVAL A.V.N.

M.G.R.

J.M.W.