ML21209A266

From kanterella
Jump to navigation Jump to search
1 to Updated Final Safety Analysis Report, Chapter 9, Figure 9.2-2, D-302-222, Revision 4, Sheet 4, Piping System Flow Diagram Service Water Cooling 8 - Train Cooling to R8CU Loop
ML21209A266
Person / Time
Site: Summer 
Issue date: 04/30/2021
From:
Dominion Energy South Carolina
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21209A581 List: ... further results
References
21-167
Download: ML21209A266 (1)


Text

A B

C D

E F

G H

J K

~

5 GPM 2300 to 2400 2000 14 SYSTEM PSIG 0 157 150 0 APPROX.

A-4

-222.

SHT.3

'F 95 95 R h-IPl-4540-HR-SW 13 DATA BY REMARKS POST ACCIO TYPICAL FLOW POST ACCIO TECH PEC MINIMUM FLOW 16" ZS

--- R~- 18 31 48-SW ROh-1 IPS-4541-HR-SW 16" PS 4541 T.£:_~Sf!_ ~

12

'0-'L

,_::..---;;x'l'Pt::s:-i-1n:10r1311:9:i.s::.w

\\.--.,-;o,...AJO.J""

6'xl2"-

35'!

'(' uJ m>-

"'0

...... z L.D.

C 0..u.J t.:) 0.. uJ 0

0: X Vl3/4~~-....LJ'----( *

~

350 HP

,x 1780 RPM

~

ROh-23 3139B-SW ROh-1 480 V IPT 4543-HR-SW I

I I

ESF B

____...J PB 4543 Pl I

4543 I

SEE NOTE CO2 LOADING SEQUENCE HYDROSTATIC TEST TEMP, 60' 12 120 95 188 214

<1%

235 ccs 8

16 95 20 214 (1%

25 ccs 5

65 95 65 95 82 ccs NOTE 3 4

120 95 188 214

<I%

235 ccs NOTE 3 2

160 95 185 95

<1%

235 ccs PSIG F

PSIG F

DURATION HYDRC BY CHO REMARK UPSET DESIGN DATA 114"= 1' -0" 0'

11 10

~L

~LARM N

N N@-DTE 9

I D~EFEAT.

ITL M

ECR 51003 l L FB j>i 7

4496 TSC ~

o 6

FT ROh-1 ROh-1 SET PRESS 185 PSIG

!FT 4496-HR-SW IFT44%-LR-SW ECR50453 13142B-SW

':' ~,

E

~~ ~

Mz M ([

is ROh-5 3151B-SW ROh-1 IPX4544-HR-SW 5'

10' 15' 6"

CIV R h-

~CO2 ZS y

ES I

~~

M r---~---

/,\\..,_.., ~

~

V---""T~sc

~:

L~

RNn25 3110B-SW CIV z

N L(l -

X -"'

2 M

LO 7

CD m'u 20' R0,*14 3136B-SW RNn24 3106B-SW 12' q

ROq-11 3137B-SW I

-3

,...,,.ccc,.-=--,-

1 c-sw I

TEST I

PEN, C~N~

3/4" 2"

2" ROp-15 13136-SW 8

7 13111-SW VENT 10" I

SM-3 XAA-IB-AH 3/4" 10' 16"xl0' 10' 10*

/RNn-13 310B-sw ROh-1 IPX4556A-HR-SW SM-3 XAA-2B-AH DRAIN 10"x8" 13114-SW AN 13112-SW VENT ROh - 3 6

M ROhl

~

IPX4546B-HR-SW j~

8" 13115-SW VENT VENT ROh-1 I'

3/4*

10' IPX4556B-HR-SW 13116-SW VENT R0h3 4

3155B-SW

/

VENT-..,

10"x8" 13113-SW DRAIN 1*

1*

STATION DRAINAGE D-911-101 LDC B-9 10*

151X 152N u

er.. -

M 16'xl0' 16'xl0' SAFETY INJECT JON SIGNAL RN,-9 31460-SW 5

10*

10' I

I I

I.

I I

I I

I -

I I -I I.

I I

I I

I I

I I

I I

I.

I I

I I.

I I

I.

I.

I O -

I -

I- -

O -

O - - -

O -

O - -

O -

I -

I- -

0 - *- -

O -

0 - -

-*,i X -

L(l -

z N

L(l -

r~sc I

4 I.

TEST I VENT R

14;, 153E-SW I I L ESF 02 RO -3 3/4*

TEST 1:1 12*

ECR-50567 XVB03107B-SW 16"

~

3/4*x1/2*

3

<fTsc I tr{SF LY7f ZS I

R h-IFT4498-HR-SW ROh-1 3153-sw c~v Tl VENT~

o2 I

ROh-1 I

IF T 4498-LR-SW IPT 4548-HR-SW 4497 [~

~SC

@l~

XPS-29B-SW I <0~2

~_/

ROH-17 13139-SW NOTES:

2" L.J DR XPS-99B-SW E-2 z

N X -"' -

-222.

SHT.3 I. ALL PIPING TO BE LINE SPEC 152N.

EXCEPT AS NOTED.

2.CHECK VALVE W/CONTROLLA8LE DASH POTS.

3. TEMP CORRESPONDING TO PERTINENT HEAT EXCHANGER OUTLET.

5.ALL STATUS LIGHT INDICATE BOTH OPEN AND CLOSED POSITIONS.

9,RECORDER SHARED WITH REACTOR BLDG SPRAY PUMP FLOW INSTRUMENTATION.

10.XPP-45B-SW DOES NOT AUTO START ON ESFLS STEP 7 POST LOOP IF ALIGNED TO SW ANO XVB-3107B-SW DOES NOT CLOSE WITHIN 10 ! I SECONDS AFTER LOSS OF POWER, 4

)/11/11 JMR REVISED PER ECR-71580 & 72367 DC 3

12108/15 KO REVISED PER ECR-51003 MGR 2

1V5/1015 RHM REVISED PER ECR-50567S/T RHM 1

Wl/1015 JTS REVISED PER ECR-51003 MGR 0

V6/09 JNC REVISED PER ECR-71215 PAH

"°*

DATE BY REVISION CKO. BY 2

AL PMT SNM PMT MGC LE APPROVAL.

1 3

u, "

m <l) 151X

... L(l XVV13143B-SW L(l M

  • ECR-50567 0:

<[ u X

0 VENT 6'

1*

YRA IN 4548 _(7s'\\_

~7

~

THIS IS A NUCLEAR SAFETY RELATED DOCUMENT. NO DEVIATION SHALL BE

!NIT IATED OR PERFORMED WITHOUT PRIOR DOCUMENTATION AND WRITTEN APPROVAL FSAR FIGURE 9.2-2 SH.4 SOUTH CARQ.IIIA ELEClRIC l OAS C()l'Alff VIRGIL C, SUIER r<<JCLEAR STAll(>>I PIPING SYSTEM FLOW DIAGRAM SERVICE WATER COOLING 8

TRAIN COOLING TO RBCU LOOP A

B C

D E

F G

H J

DESIGN ENGINEERING K

V, C, SUlillilCR NUCLEAR STATION..IE*l<ISVUE, 5, C, CHECKED LE APPROVAL JNC PAH J,

D-302-222 DRAll I P<fO r<<JMBER MGC 4

4 SHT, NUl,EIER REV