ML21209A233
| ML21209A233 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 04/30/2021 |
| From: | Dominion Energy South Carolina |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML21209A581 | List:
|
| References | |
| 21-167 | |
| Download: ML21209A233 (1) | |
Text
A B
C D
E F
G H
J K
14 13 12 11 10 SYSTEM DATA
[(> GPM PSJG
° F REMARKS 1
111 ll'J93 557 MAX.BO RATE
~
SIX PLACES __
2 1
13111 12111 SAMPLE FLOW 3
84 1080 120 MAX.BO RATE 4
250 40 120 MAX.BO RATE stfl'EY Cl.ASS VERIFJCATH>>JS allGINATED BY I
EJA 2-12-74 RE\\IIEIIED BY I
RHK 2-12-74 8
7 ISOLATION VALVES CLOSE SIGNALS
- 1. CONTAINMENT !SOLA TION SIGNAL PHASE 'A'
- 2. START OF EMERGENCY F.W. SYSTEM NOTE:
A MANUAL OVERRIDE IS PROVIDED FOR SIGNAL (*) ABOVE.
SWITCHES FOR THESE VALVES ARE PROVIDED ON MAIN CONTROL BO <XCP-6112).
A COMMON SWITCH IS USED FOR "B" TRAIN VALVES.
6 E-4
< -011 "M""s=---
5 J-14
- --~
I RM I ~3 PLACES 4
HIGH RADIATION SIGNAL FROM RM-L3 CLOSES VALVE 524 &
OPENS VALVES 525 & 541.
3 2
HIGH RAO!A TION SIGNAL FROM RM-Ll0 CLOSES VALVE 547 1
IRC ORC NEXT LETTER (j_)
STEAM GENERATOR WET7 LAYUP PURIFIER SKID RGL-1
/
XPT-9-BD 2"
100 GPM PUMP 2"
RGL-1 1/2"
/
4716-HR-BD RGL-1 1/4"
/
10533-BD 1-'-ll~f-SAMPLE RGL-1
/
XPP-501116-BD RGL-1 VEN/' 10534A-BD 1/4'f RGL-1 4
/
XFL-5045A-B0 C@:]1i,-,,---1
/
RGL-1 10525A-BD F i--ll)§l'.J;,....,--,
2" 1/2" / RGL-1 10526A-BD s
RGL-1 DRAIN
~
RGL-1
\\ 10532-80 2"
2" Y---:---r--.:;;,..-,!~s*--t---,
2" C@:]11o------1 RGI -l XPS-5032-BD VENT RGL-1
/
10534B-BD 2"
RGL-1
/ XFL-5111458-80 2"
F o
I 3" -----------
/
RGL-1 10525B-BD
/
RGL-1 RGL-1 4715-HR-BD 10526B-BD 1/2"'
0 RGL-1
/
I RGL-1 4717-HR-BD RGL-1 10527-BD RGL-1
/ )k
'1 1111528-BD
\\
RGL-1 IFM-4 719-BD
'ii.('
, 10531-BD 1 2"
~
10529B-B0 DRAIN STEAM GENERATOR XSG-2A-RC 2"
RO -15 502A-BD STEAM GENERATOR XSG-2B-RC
!MB ! 0MB
- -.. I
' I 5268-BO
,1::5,"
RGL-1 2'r
- 1 i
. -.. - 3'1 ~~524~BD *. _3"]:. _1:'. _:. -
. RAI_N_ -.. ~MPLE. ~---:._::-c1/4~'~~:--.,10"'~°'~"'~--,-k'-'o i
l:
F-13 211 G-13 0 t--~--1)(1-- -771 ss
~
~i-,,1, __ 3...,"-~--11 -E0~5)
XPS-511130-BD
~
XPS-511!31-BD 2"
2 11
---~0@0---~
2" 1MB ! 0MB
,* -.. I I
3" 903R ROb-28
/
51/J4A-BD
. HI -TEMP CLQSE ~
NOTE 1 SET Ill 135'F 1 '(1/
STEAM GENERATOR XSG-2C-RC ROo-15 5278-BD 2
G-13
'-[;"(1--1 -771
/
H-13 01-~-"'l)(l'--I-771 ss 2 11 2"
..---~0@0i-----~
1MB ! 0MB X
LD LO -
4 X -
LO -
I" \\
RNc-12 155X 151X 509-BD VENT
~
© E-13 r.,
3/4 1/2"
'-----l 3
f---, 806-005 ')-.L..[)!(J-,--f--.J--(}:--;15::1:-;{X C
~
512-B0
\\
ROb-29 511-B0 HYDROSTATIC TEST TEMP. TO BE 60' 4
14"'
125 40 125 <1%
60 JJW PLS 3
1185 125 1304 600 <1%
1480 EJA KL 2
1185 125 1304 600 <lY.
1480 EJA KL I
1185 600 1304 600 <1%
148111 EJA KL
~
HY* BY CHKO REMARKS NORMAL UPSET ORO DESIGN DATA 1/4 11 ::: 1'*0 11 0'
la\\
1" 2"
1 vl' R
-15 50 C-BD 15'
' I 2
H-13
'-!;lll(l"'-1 -771 ROo-15 527C-BD
/
ss 20'
' ' ! "-'~
' cc I~
" ID I isi
! Cl~,l,,ii'j
- c-,~~
1CO u..J
!u
.~
! isi
" *----- -- -*1 PEN.
RGh-2 519A-BD RGH-2 XHE-13A-BD2 " >--
1" cqn I -------------
I N2 PURGING\\
ROb-45
\\
1111513-D r.,
ROb-45 10512-BD 2"
151X I
I I
I I
I I
-102 T
4" 4
3
~
TS Q)
~I
~-<4706A - - - - -
A 4"
BY SCE&
NOTE 1
~
~BY SCE&G 530A-BO TURBINE BLDG.
SUMP ROb-9 ~~
CO lPT-4707A-HR-BD ROb-64 537-BD '--
RGH-2 XHE-13B-BDI RGH-2 I
XHE-138-B02 PRT-RNn-63 503B-BD 2A NOTE 2
- csv PTR-RNn-63 503C-BD ROb-9 IFT-470 B-HR2-BD ROb-9 ROb-9 10500-BD VENT r
- :,
VENT r::,
\\
IFT-4 702C*HR2-BD 3/4" ROb-'l b-9~
IFT-4702C-HR1-BD 0503-BD 902X 4702C
( I 14 )
902X 151X 1 4 902X 151X
~-~---
RGH-2
' XHE-13C-BDI RGh-2 519C-BD
!1/2'
~~=~"t:~l"""~-...,~r
~--;-
~ ~ s 3/4, 2A NOTE 2 105!1!1-BD c,,
DRAIN L!'.l 3/4" VENT 01X 902X DRAIN
-4 7 10511-BD ROb-45 10522-BD L
1 2 2"
3"
~rtr.:r~'4;.__"
J.,
1" 3/4" DRAIN
-45 I-BO m
L 3/4'*HtN VE'NT
~
S 2"
536B-B0 !8 I 2 TS 471112C 903R 902X /;
RMo-21 I V-4 I -
ROb-9 MRF-21309 519C-BD
~~
~
902X 151X 2"
G,,.,.,._..__...1.~-,;"'--"'---fiB,..----I CO 151X 2"-151X MRF-20613 /
XVG-177111-BD L.C.
G-4
-102 151X co BY SCE8,G XST-96B-BD L.C. /
ROb-9 529A-BD 3"
MRF-2111613 XVG-1771-BD
\\
3" R0b-64 528B-BO 3"
NOTES:
- 1. ALARMS LOCATED ON NUCLEAR SLOWDOWN PROCESSING PANEL (XPN111029) WITH ONE COMMON ALARM ON THE MAIN CONTROL BOARD.
- 2. QUALITY RELATED PER TRP-13, SECTION 9.
PIPING CONTROLLED FOR BREAK EUMINA TIDN ANALYSIS.
- 3. HOSE CONNECTION AVAILABLE TO SATISFY OPERA TING LICENSE CONDITION 2.C.(34).
./L-'"---- 3/4" BODY VENT 3" 4 3 MRF-20613 XVG-1772-BD Hv~
A I
I I
~*,~
""yNOTEV 1
C RDb-9 IPT-471117C-HR-BD ROb-6~
528C-BO ROb-64 \\
529C-BD /
RNo-44 525-80 3"
4" 4"
THIS IS A NUCLEAR SAFETY RELATED DOCUMENT. NO DEVIATION SHALL BE INITIATED OR PERFORMED WITHOUT PRIOR DOCUMENTATION AND WRITTEN APPROVAL FSAR Figure 10.4-13 DRAWING LEGIBILITY CLASS 1 SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATION 27 7/B/03 JMR 26 11/13/97 AVN 31 12/10/07 RHM 30 6/6/06 RHM 29 04125/06 JTS 28 7/13/04 DDJ NO.
DATE BY SCE&G CAD ENHANCED PIPING SYSTEM FLOW DIAGRAM CADD ENHANCED PER ECR-50239 REVISED PER CGSS-97-0579 REVISED PER ECR 50692A REVISED PER ECR-70878 REVISED PER ECR-70799 REVISED PER ECR-70481 REVISION STEAM GENERATOR SLOWDOWN MGR DDJ 6
LEK MGR SCE&G MGR RAT A SCANA COMPMY M/>OE MGR CCB
- 1.
MGR LHF MGR CCB LE CKD. BY APPROVAL
"~
NO SCALE TAK DESIGN ENGINEERING V. C. SUMMER NUCLEAR STATION JENl<JNSVILLE, S, C.
CHECKED LE APPROVAL
- 2.
DCW PJS D-302-781 31 ORAIIINO NUMBER A
B C
D E
F G
H J
K