Text

A B

C D

E F

G H

J K

17 4

390 3

20 2

250 16 eves RC FLTR E-302-67-4 LOC.

F-6 r.1,,-i--,~ 1-7053

\\:.J 3--X42D 3

15 14 13 12 fE1ri jPmj i i@;-;-S--~-~TBCB ---:

I I

R 1 9R ~R R

I I

I I

I I

I L

__ l----~:::. ~~:

',,,,. i i

i I

I I

I R

I 1

I I

I eves LETDOWN I

1 AUX I

E-302-674 11 LDC.

G-6 I

R.R.

I I

I I

I I

I I

I I

I I

I I

I I

I L------------------------------L------ ------------------, I I

I I

Fri]

,/',*,.-;.,.-----,-,

ii I

l'::::'::I I

3~I~~

0 I

TB I

I

F.c--

386 ---i F.C, I

I ANNUN.

R RI I

I I

11 0E\\_:_

~

3/4-CS-152 I

I I

l'1/2ci 1----< 3

.-+,-.._----1c-=-=---1

--~-~--~---J 3-CS-301R

~

I 3-CS-301R I

R I

I CV-12

""tr,"

i

~

oc~~~~© 1-CS-152 1

I I

i I

I 3/4-CS-152 6X4 1-7032 6-G32 3-CS-301R XHE01-TR ITEM: AHMH MODERATING HX

© SAFETY CLASS 3

--1-- --- - -- - 7 I

F.C *..,,l::; l-TCV-386 I

Ui.J"'t'..

4-BA32R

-CS-301R 3/4" I

6X4 TW-376 1-7030 6-G32 10 6-CS-152

-~

~~

~JR

'09""

6-CS-152 VENT CV-45 1-702'J 6-832 CV-36 G-CS-152 Cl D-302-851 LOC.

F-13 6X5 VENT CV-35 r-='--,!, F 8

DW D-302-715 LOC. D-5 1-7028A 6-G32 l-70288 6-G32 7

\\J) 1-71!134 2-3/4320 3/4-CS-152 1-7050A 6-C32 6X3 XPP47A-TR V

CV-39 1-7042A 3/4"-X32 1-CS-152 l-7060 l"-C32

-a-1-7061 1"-X32D DRAIN GX3 3/4" CHILLER />UMPS SAFETr CLASS-NNS ITEM; APC1 l-7025A 6-G32 XPP47B-TR VENT CY-40 3/4" 1-7025B

£-G32 6

CHEMICAL ADDITION 2-CS-152 ITEM: ATSG CHILLER SURGE TANK SAFETY CLASS-NNS XTK38-TR V

© 1-7036 2-X320 NOTE CJ XST-85A-TR TEMP. STRAINER 1-7024 6-G32 8-CS-152

'-._ l-CS-152 5

1-7055 2-X320 NOTE 7 eves LETDOWN E-302-674 LOC.

B-14

~~~----~..-1/2" VENT 4

~

BLANKING PLATE NOTE 13 4

3 Hl.. - __ _fw]

1 L~/ 1 ___ -~LO REF. C

~

R 3808 R REF. C ANNUN.

Eg
~

ANNUN.

@ ©R ________ J 1/4 I

I

/--..J~Ec, I

I LOY 380 R

I I

1-703'1-'

3-C78 I 3-CS-601R L.C.

1-7038

~----"11"3-T78 RHT 0

~., ".. [(".

\\ ~

LETDOWN eves LETDOWN E-302-674 LC. C-16 NOTE 4 CV-24 REHEAT HX

~

BLIND FLANGE ITEM: AHLR F.C.

4X3 NOTE 4 RHT RHT NOTE 4 4X3 1-7037 2

l

.._.._~\\°"Z-t

~l--------l------- --------------,

DRAIN 1-70428 3/4"-X32D NOTE 'J XST-858-TR TEMP. STRAINER 3-T78

~

~

F.O, TW-384 T-109A ~D/

REF. S 389 R

1-7018 3/4-T5B I fuJ A__ L ~

\\eT VR 1-70238 3/4-X42D 1-7023A 3/4-X42 1/4-CS-301R 8D 3/4" 1-7046 3-OA42O CV-42 DRAIN 1-7045 3-DM2D cs TR CV

~

--@"y 385 R

I R

_fa\\
--~

~

~

18101 17001 cv-1 SYSTEM SUFFIX FIRST NO.

VALVE NUMBERING 18121 17026 CV-66 LAST NO.

1-7027 2-X42D 3-CS-301R 1-7020 3-X42D BRS E-302-751 LOC. A-12 3-CS-31111R 4X3 0

l-7043 I

3/4-RV32SW 3/4-CS-152 CV-13 6-CS-152 ~

I I

I 170'01-TR I

DRAIN CV-418 DRAIN 4X3 3/4" CV-14 NUC DRAINS TO WHT D-302-B22 LDC, H-8 VENT CV-15 CV-16 L----------1 CI D-302-851

LOG, E-13 1-7001 3-X42R 3-CS-301R HUC DRAINS TD WITT 0-302-822 LOC. H-8 F.C.

1-7rll02A 3-DA42R l-7056 3-C58 0

0 4X3

© ITEM: AHLC t~3 i,jx r;,,;;:,.:-,:::==::!-_J LETDOWN CHILLER HX 74 3/4" TUBE SIDfa SAFETY CLASS 3 CV-18 SHELL SIDE: SAFETY CLASS NNS XHE08-TR CV-17

!3 DRAIN 80 F.C.

1-70028 3-0A42R I

I I

I I

3-CS-301R (i) 1-7004 3-X42O LC 3-C5-301R AMWST RMW D-302-7~!

LOC.

-8 NUC. DRAINS TO WHT -302-822 LDC. F-13 eves vc1 E-302-675 LDC. C-13 CV-26 I lr,7, 1-7006

...-I 3/4-RV74SWB 1-7007 3-X42D 3-CS-301R Hl-381 3-CS-301R NUC DRAINS TO WHT E-302-822 LOC, H-7 WPS 0-302-737 LDC. 0-9 3

8D 1-70"40 3-DA42O F.O.

1-7041 3-DA42O 2-CS-301R 1-70100 2-DA42O RESIN FILL F,O.

~

l-7011O 3-}'420 3-CS-301R 6X3 NOTE 11

-CS-30JA 1-70160 3/4-X42O THERMAL REGENERATION OEMINERALIZER N0,4 ITEM, IJl1RE SAFETY CLASS 3 XOM07D-TR 1-7048D 2-X42D 2-CS-301R 1-7012D 2-)(420 HS-301 3-CS-3!:11R I

I I ~----------~------------------------------~---~----------J 3-CS-301R 3X2 1-7010C 2-DA42D RESIN FlLL 2-CS-301R F.D, 1-70rn1B 2-DM-2D RESIN FILL 2-CS-30!R F,D, 1-7010A 2-DA42D RESIN FILL 2-CS-301R F,D.

~

2-CS-301R 2-CS-301R

~

0 2-CS-301R

-CS-301R 2-CS-3!!!R 1-7011C 3-X42D 3-CS-3f'il1R NOTE 11 6)(3 3X2

...---t--=C THERMAL REGENERATION DEMINERALIZER NO,3 ITEM: DMRE SAFETY CLASS 3 XDM07C-TR

\\

1-7012C 2-X42O 2-CS-301 2-CS-301R L.C,

-CS-301R 1-70168 3/4-X42D 1-7011B 3-X42D 3-CS-301R 3)(2

...---t--'C THERMAL REGENERATION DEMINERALIZER NIJ.2 ITEM: DMRE SAFETY CLASS 3 XDM07B-TR

\\

1-70128 2-X42D

'2-CS-301 6X3 NOTE 11-/7¢,1;.,.k,..,

3X2

,.,--j--C, THERMAL REGENERATION DEMINERALIZER N.1 ITEM, IJl1AE SAFETY CLASS 3 XDM!17A-TR 0

,x2n..__-l--.,.,.,.

2-CS-301R i4-CS-301R NOTE 10~ Ci1I) 1-7052

~::111o~....1.--1 2-X42(J QR 2-X420 3-CS-301R I

2-X42D 1 7*48B l-701SA 1-7048C 3

3/4-X42O ~

1'4'_ L.C.

~m*e~IH~------*i_...,, ____......._ ______.,.. ______ i=.... ------------------*i=*=-------J------!!---ml-..1

~

I 3-X42D tD

>JPS 1-70170 2-X42D 2-CS-301R 3X2 l-7017C 2-X42D E-302-737 LOC.

J-!l 3-CS-301R 1-70178 2-X42D 2-CS-301R 3X2 NOTE 8 BD F.C.

3 -CS-301R l-HCV-387

3-WA54DE I

I I

I I

I I

I I

I I

I

,---(*~- INSl BUS I

,_ __ T ___ HI I

REF, C ANNUN.

NOTE 12 I

eves rcv-143 SH.2 LOC. 1-5

!--~------------~,.,._. **

1-7058 3-A42R BD 1-705(j -..,.-,,_,..

3-M420""'*'~

1-7012A 2-X42D 2-CS-301 3-CS-301R F.O.

NOTES:

I I

Ull-773A

1. THIS DRAWING IS BASED UPON OWG.

114E073, SHEET 4 OF 5, REVISION 16 ("BASE DRAWl>IS"IOF WESTINGHOUSE ELECTRIC CORPORATION, NULCEAR ENERGY SYSTEM, PITTSBURGH, PA WHO IS SOLELY RESPONSIBLE FOR THE ACCURACY OR THE RELIABILITY OF THE OESIGN INFORMATION SET FORTH IN THE BASE DRAWING.

2. FOR ALP!-Ul REFERENCES. SEE OWG, E~30Ml!ll2, FLOW DIAGRAM LEGEND.
3. ALL VALVES ALIGNED FOR BORON REMOVAL CDILUIONI
4. SE£ DWG. D-302-823.

5, FOR CONVENTIONAL PIPING SPECIFICATIONS, SEE GAi SPECIFICAHON SP-329--446Ml0, PAGE 29,

{WESTINGHOUSE PIPE CLASS CONVERSION TO ENGINEER'S PIPE LINE SPECIFICATION).

6. SYSTEMS AND CDMf'ONENTS MARKED AS OR HAVE BEEN OB..ASSJFIED TO DUALITY RELATED AS CO\\/ERED BY QRP-1.
7. CHILLER SURGE TANK MUST BE THE HIGH POINT IN THE CHILLER CIRCUIT.
8. ORIENT 3-WAY VALVE TO FAIL WITH FLOW BYPASSING DEMINERALIZERS.
9. TEMPORARY STAINER IS PLACED IN SPOOL PIECE CIJRING INITIAi.. FLUSHING OPERATIONS. STRAINER MUST BE REMOVED BEFORE PLANT START-UP,
10. DRAIN HEADER CONNECTION TO BE PROVIDED NEAR BY FOR CONNECTING HOSE FOR DAAINING BY GRAVITY.
11. PROVIDE 6' OF 6" PIPE BETWEEN OEMINERALIZER AND REDUCER, 12o POT CONTACTS. VALVE TO LATCH CLOSED. MANUAL RESET TO BE PROYIOEO,
13. LETDOWN REI-EAT HX SIDE OF BLANKED OFF FLANGES NOT HYDRO TESTED.

BLANKING PLATES MAY NOT BE REMOVED.

THIS IS A NUCLEAR SAFETY RELATED DOCUMENT. NO DEVIATION SHALL BE INITIATED OR PERFORMED WITHOUT PRIOR DOCUMENTATION AND WRITTEN APPROVAL FSAR Figure 9.3--16 SH. 4 HYDROTEST TEMP. 40'F IMJN,I SOUTH CMQ..JHA 8.ECmJc l GAS c~

VIROEL C, S\\lll£R N.Ja.EAR STATfON 301 600 382

( 1%

140 150 140

( 1%

140 300 380

< 1%

750 750 190 22 375 330 DRAWING LEGIBILITY CLASS 1 SCE&G CAD ENHANCED PIPJNG SYSTEM FLOW DIAGRAM CHEMICAL AND VOLUME CONTROL 1

250 140 300 160

< 11/.

290 275 11 l/lS/05 JMR REVISED PER ECR-70502 10 3/16/04 DDJ REVISED PER ECR-50506 9

04/01/99 TGB REVISED PER ECR-50102 MGR GK MGR KL DESIGN ENGINEERING

[ID,-P=SJ=G~_*_F_+-'-P~Sl=G~-*~F--,

DESIGN I

NORMAL UPSET DURATION HYDRO DESIGN DATA

!SI HYDRO l/4'1= 1 I -0 JI 0'

5' 13' 14 5/3/06 JTS CAOD ENCHJINCEO PER ECR-50239 13 3n/OO RHM REVISED PER ECR-70793 12 Tl/~,00 RHM REVISED PER ECR-505060 HO.

DATE BY REVISION 15 1 20' RHM LRC LEK MGR MGR RHM MGR BCB LE CKO, 6Y N'l>ROVAL ACI V. C. SlJU ER NJCLE.lfi STATION JE~INSV!.U: S. C.

MGR E-302-676 m;,wn,ai IAlHBEi'I LE Al'PllOYAL JMG 14 SHT. ~

REV A

B C

D E

F G

H J

K RN 04-013 November 2006