E10-08-009 Version 4.0 EHS&L Document Licensing - NRC Materials License SNM-1227 - Chapter 9 Environmental Protection Page i EHS&L Document SNM-1227 - Chapter 9 Environmental Protection Nature of Changes Item Paragraph Description Justification 1.

9.4.2 Replaced gross alpha beta with isotopic uranium and Tc-99 Uranium and Tc-99 are the specific analytes of concern.

2.

3.

4.

5.

6.

7.

8.

9.

10.

List Below any Documents, including Forms & Operator Aids which must be issued concurrently with this document revision:

This document contains a total of 10 pages excluding the signature page.

E10-08-009 Version 4.0 EHS&L Document Licensing - NRC Materials License SNM-1227 - Chapter 9 Environmental Protection Page ii DOCUMENT REVIEW/APPROVAL/DELETION CHECKLIST All new and/or revised procedures shall be approved by the change author, cognizant manager(s) of areas affected by the changes, and by applicable manager(s) of any function that approved the previous revision of the document unless responsibility for such approval has been transferred to another organization. Also, the procedure shall be approved by manager(s) of functional organizations that provide technical reviews. Finally, Document Control shall verify that the required approvals have been properly obtained and that any documents that must be issued concurrently are ready to be issued.

Document Reviews Document Approvals Purpose/Function of Review Specify Reviewer(s)

(Optional except for change author)

(Check all that apply)

Title of Approver (Check all that Apply)

Document Control (Automatic)

Document Control (Automatic)

Change Author CD Manning Author Independent Technical Review TJ Tate Operability Review(s)

Mgr, Richland Operations(1)

Conversion Recovery Mgr, Uranium Conversion &

Recovery Operations(1)

Ceramics Mgr, Ceramic Operations(1)

Rods Bundles Mgr, Rods & Bundles(1)

Components Mgr, Component Fabrication(1)

Lab Review Mgr, Analytical Services(1)

Maintenance Review Mgr, Maintenance Transportation Mgr, Ops Strategy & Supply Chain EHS&L Review(s)

Mgr, EHS&L(2)

Criticality Radiation Protection Mgr, Nuclear Safety Safety Mgr, Safety Security/Emergency Prep.

Fire Safety Mgr, Security & Emergency Preparedness MC&A Transportation Environmental JB Perryman Mgr, Licensing & Compliance Mechanics Richland Review Mechanics Lynchburg Review Mgr, Mechanics Richland Plant Engineering Review Mgr, Plant Engineering & TS&M Quality Review Mgr, Richland Site Quality Purchasing Review Mgr. Purchasing PP&CPC Review Mgr, PP&CPC Others:

Mgr, Richland Site/Other Document Control Richland Records Management Training & Employee Dev.

Training & Employee Dev.

(1)Note: If approvals include 2 or more product center managers, the Operations manager can be substituted for the applicable product center managers.

(2)Note: The EHS&L manager can be substituted for the applicable EHS&L functional managers.

E10-08-009 Version 4.0 EHS&L Document Licensing - NRC Materials License SNM-1227 - Chapter 9 Environmental Protection Page iii 23371 (Rev. 001, 01/09/2018)

EHS&L CHANGE IMPACT EVALUATION FORM The scope and content of this document have been determined by EHS&L to not impact the safety disciplines checked below. Future revisions do not require review by those EHS&L component(s) unless the scope changes such that a previously excluded safety discipline may be impacted.

Criticality Radiation Protection Safety/Security Emergency Preparedness MC&A Transportation Environmental CHANGE EVALUATOR*:

DOCUMENT VERSION:

EHS&L REVIEW COMPONENT:

EVALUATION DATE:

2ND PARTY APPROVAL*:

The scope and content of this document have been determined by EHS&L to not directly impact the safe handling of licensed materials (enriched uranium). Future revisions to this document do not require the 10CFR 70.72 change evaluation unless the scope of the document changes such that it directly impacts the handling of licensed materials.

DOCUMENT / ECN NO**:

E10-08-009 EVALUATION DATE:

7/12/2021 CHANGE EVALUATOR:

CD Manning Does the change potentially impact Criticality Alarm System (CAS) coverage?

YES NO EVALUATION OF NRC PRE-APPROVAL:

IS NRC PRE-APPROVAL ( LICENSE AMENDMENT ) NEEDED?

Based on YES answer to any of five questions below.

Based on NO answer to all five questions below.

YES NO 1.

Does the change create new types of accident sequences that, unless mitigated or prevented, would exceed the performance requirements of 10 CFR 70.61 (create high or intermediate consequence events) and that have not previously been described in Framatomes ISA Summary?

YES NO 2.

Does the change use new processes, technologies, or control systems for which Framatome has no prior experience?

YES NO 3.

Does the change remove, without at least an equivalent replacement of the safety function an item relied on for safety (IROFS) that is listed in the ISA Summary?

YES NO 4.

Does the change alter any item relied on for safety, listed in the ISA Summary, that is the sole item preventing or mitigating an accident sequence of high or intermediate consequences?

YES NO 5.

Does the change qualify as a change specifically prohibited by NRC regulation, order or license condition?

YES NO Evaluation of Actions Required PRIOR TO OR CONCURRENT with Change Implementation:

6.

Modification / Addition to CAS system or system coverage documentation YES NO 7.

Acquire NRC pre-approval (LICENSE AMENDMENT)

YES NO 8.

Conduct/modify ISA YES NO 9.

Modify /

update the following:

None Other ISA Database Red-Line Drawings/P&ID NCSA NCSS NCSP PHA RHA FHA ChHA Procedures Evaluation of Actions Required SUBSEQUENT TO Change Implementation:

10. Modify /

update the following:

None Other ISA Database AS-Built Drawings/P&ID NCSA NCSS NCSP PHA RHA FHA ChHA Procedures Justification Section for YES preceding Questions 1 - 8 or other for 9, 10:

(*)

Only required if one or more of the boxes to exclude a particular safety discipline review is checked.

(**)

If this form exists as a part of a document, the document number is not required.

E10-08-009 Version 4.0 EHS&L Document Licensing - NRC Materials License SNM-1227 - Chapter 9 Environmental Protection Page iv Table of Contents 9.0 Environmental Protection...............................................................................................9-1 9.1 Environmental ALARA........................................................................................9-1 9.2 Gaseous Effluent Control....................................................................................9-1 9.2.1 Gaseous Effluent Sampling..................................................................9-1 9.2.2 High-Efficiency Particulate Absolute (HEPA) Filtration.........................9-1 9.2.3 Final HEPA Filter Surveillance..............................................................9-2 9.3 Liquid Effluent Controls.......................................................................................9-2 9.3.1 Wastewater Collection/Treatment.........................................................9-2 9.3.2 Wastewater Sampling...........................................................................9-3 9.4 Environmental Monitoring...................................................................................9-3 9.4.1 Surface Environmental Sampling.........................................................9-3 9.4.2 Groundwater Sampling.........................................................................9-3 9.4.3 Sanitary Sewer Sludge Sampling.........................................................9-4 List of Figures Figure 9-1 Environmental Sampling Stations............................................................................9-5 Figure 9-2 Groundwater Monitoring Wells.................................................................................9-6

E10-08-009 Version 4.0 EHS&L Document Licensing - NRC Materials License SNM-1227 - Chapter 9 Environmental Protection Page 9-1 9.0 Environmental Protection 9.1 Environmental ALARA The Richland sites as low as reasonably achievable (ALARA) program is described in Chapter 4.0, Radiation Protection. With respect to environmental protection, Framatome Inc.s (Framatomes) goal is to maintain concentrations of radioactive materials in plant effluents and the surrounding environs at ALARA levels. Furthermore, environmental releases shall be limited and monitored such that compliance with the public dose limits of 10 CFR 20.1301 and the effluent limits of 10 CFR 20.1302 can be achieved and demonstrated.

9.2 Gaseous Effluent Control Operating and engineered controls will be used as necessary to ensure that environmental airborne concentrations of radioactive materials attributable to gaseous effluents and resultant radiological doses to members of the public comply with the concentration limits and public dose limits specified in 10 CFR 20. The site will maintain procedures with action levels to assure that compliance with applicable limits is maintained. This includes the ALARA constraint on air emissions of 10 CFR 20.1101(d).

Dose calculations as well as environmental concentrations in 10 CFR 20, Appendix B, Table 2 for members of the public may be modified based on ICRP 66 and 68, assuming an Activity Median Aerodynamic Diameter (AMAD) of 1 micrometer.

9.2.1 Gaseous Effluent Sampling Continuous representative sampling shall be provided on stacks exhausting air with potential concentrations of radioactive materials that are significant with respect to the sites compliance with 10 CFR 20. These samples shall be periodically analyzed for particulate radioactive material, generally on a weekly basis. Stack samples of gaseous effluents potentially containing uranium shall be analyzed for gross alpha activity. Non-uranium isotopes likely to contribute less than 0.1 mrem total effective dose equivalent (TEDE) per year to a member of the public will not necessarily be accounted for.

Sampling of exhaust air stacks may be suspended when the underlying ventilation system has been shut down in conjunction with a cessation of the processing of radioactive materials in the affected ventilated spaces (see Sec. 4.6.1, Ventilation). Any passive emissions of radioactive materials from the stack shall be abated via the continued presence of the HEPA filters required to be in place when the emission unit is operating. Special provisions for restart, if deemed necessary, shall be formally documented/implemented.

9.2.2 High-Efficiency Particulate Absolute (HEPA) Filtration Air exhausted from areas, equipment, and/or activities that may contain concentrations of radioactive materials that are significant with respect to the sites compliance with 10 CFR 20 shall be passed through at least one stage of HEPA filtration prior to release via an exhaust stack. Fire-resistant HEPA filters that are certified by the manufacturer as meeting HEPA efficiency specifications shall be used.

The adequacy of final HEPA filter installations shall be verified by in-place testing prior to initiating operations with radioactive materials in the following instances:

E10-08-009 Version 4.0 EHS&L Document Licensing - NRC Materials License SNM-1227 - Chapter 9 Environmental Protection Page 9-2

Startup of a new facility.

Following replacement of final filters

After maintenance work on the final filter bank that could have foreseeable adverse impacts on their effective operation.

After exposure of the final filters to a condition or agent that may have adversely impacted their effective operation, if deemed necessary based on a visual/operational inspection.

9.2.3 Final HEPA Filter Surveillance Measures will be taken to conservatively monitor the potential onset of, or adverse emissions impacts from, HEPA filter deterioration caused by corrosive chemical fumes. These measures will include the following:

implementation of a preventive maintenance (PM) procedure for the periodic inspection of HEPA filters (primary and final banks) in systems exhausting air from areas or process equipment containing corrosive fumes. The PM procedure will designate the applicable systems, specify required frequencies of inspections, and identify required actions in the event of unacceptable results.

maintenance of a site procedure for the periodic measurement of differential pressures across HEPA filter banks; and

maintenance of a stack emissions monitoring procedure that includes action levels triggering notifications to the maintenance/engineering organization and performance of HEPA filter inspections at measured offgas radionuclide concentrations well below applicable modified 10 CFR 20 Appendix B effluent limits. Inspections trigger repair or replacement as needed.

Final HEPA filter installations shall be equipped with pressure differential measuring/indicating devices. Measured differential pressures shall be used to evaluate the need for filter changeout/maintenance. See Chapter 4, Section 4.6.1 for evaluation criteria.

9.3 Liquid Effluent Controls Operating and engineered controls will be used as necessary to ensure that concentrations of radioactive materials in liquid effluents and sewer discharges are compliant with 10 CFR 20.1302 and 10 CFR 20.2003, respectively. The site will maintain procedures with action levels to ensure that compliance with applicable limits is maintained.

9.3.1 Wastewater Collection/Treatment Wastewaters contaminated with, or subject to contamination with, radioactive materials shall be managed, as appropriate, within the plants process wastewater management system(s). After any necessary treatment, process wastewaters may be combined with plant sanitary sewage and non-contaminated cooling water streams for discharge to the City of Richland sewer system. The process wastewater management system(s) shall provide treatment required to assure compliance with 10 CFR 20 radiological sewering limits.

9.3.2 Wastewater Sampling The plants combined liquid effluent shall be proportionately sampled for uranium and measured for flow at the Framatome plant effluent monitoring station prior to discharge to the city sewer.

Utilization of an appropriate grab sampling program is permissible on a short-term interim basis

E10-08-009 Version 4.0 EHS&L Document Licensing - NRC Materials License SNM-1227 - Chapter 9 Environmental Protection Page 9-3 to cover instances when the proportional sampler is inoperable. Discharge data based on grab samples shall be so noted in the plant liquid effluent sampling records.

9.4 Environmental Monitoring Framatome shall conduct a routine environmental surveillance program relative to operation of the Richland fuel fabrication facility. Surface environmental media and groundwater samples shall be collected from strategic locations in the surrounding environs and analyzed for pertinent constituents of concern.

9.4.1 Surface Environmental Sampling Surface-level environmental media shall be sampled for uranium and fluorides per the following schedule. See Figure 9-1 for the location of the stations.

Sample Station Media Frequency Analysis 1

Soil Quarterly Uranium 2

Soil Quarterly Uranium 3

Air Monthly Fluoride 4

Air Monthly Fluoride 5

Forage Monthly*

Fluoride 6

Forage Monthly*

Fluoride During the growing season only (April-September) 9.4.2 Groundwater Sampling Samples of groundwater shall be collected as outlined below. The program design (sampled constituents and well locations) focuses on current facilities managing the plants major process wastewater streams as well as the legacy surface impoundment (lagoon) system. See Figure 9-2 for locations of the groundwater monitoring wells.

Well Numbers Frequency Analysis GM-1, GM-2, GM-5, GM-6, GM-7, GM-8, GM-10, GM-12 Semi-Annually Isotopic Uranium, Tc-99,

fluoride, nitrate, pH 9.4.3 Sanitary Sewer Sludge Sampling The release of radioactive materials to the municipal sewer system shall be controlled and sampled as described in Section 9.3. In addition to the effluent monitoring described therein, Framatome shall conduct a routine sampling program for the radioactive content of sewage sludge produced at the City of Richland sewage treatment plant. Samples of the sludge in its

E10-08-009 Version 4.0 EHS&L Document Licensing - NRC Materials License SNM-1227 - Chapter 9 Environmental Protection Page 9-4 dewatered (semi-dry) state, as subsequently landfilled, shall be collected quarterly and analyzed for uranium and moisture content. The uranium-based activity in picocuries per gram of sewage sludge (as landfilled) shall be maintained below 30 pCi/gram for any confirmed single sample result and below 25 pCi/gram of sewage sludge as an annual running average. Results in excess of these values shall be cause for investigation, with a follow-up action plan as appropriate to restore compliance with limits.

E10-08-009 Version 4.0 EHS&L Document Licensing - NRC Materials License SNM-1227 - Chapter 9 Environmental Protection Page 9-5 Figure 9-1 Environmental Sampling Stations

E10-08-009 Version 4.0 EHS&L Document Licensing - NRC Materials License SNM-1227 - Chapter 9 Environmental Protection Page 9-6 Figure 9-2 Groundwater Monitoring Wells

Document

Title:

SNM-1227 - Chapter 9 Environmental Protection Document Number and Version: E10-08-009, 4.0 Signature Date User Meaning of Signature 12-Jul-2021 Manning, Calvin Author 12-Jul-2021 Tate, Timothy on behalf of ehsl_mgr (ehsl_mgr)

Richland EHS and L Manager