framatome July 14, 2021 TJT:21:016 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards 11555 Rockville Pike One White Flint North Rockville, MD 20852 Gentlemen:

Subject:

Submittal of Revised Chapter 9 of Framatome Inc.s (Framatomes)

Richland, Washington Fuel Fabrication Facility; License No. SNM-1227; Docket No. 70-1257.

Enclosed with this letter is a revised Chapter 9 of SNM-1227. This chapter change was made on June 12th 2021, and includes changing the ground water sampling analytes from total gross alpha/ beta to isotopic uranium and Tc-99 and changes wastewater management system to wastewater management system(s). Isotopic uranium and Tc-99 are the specific isotopes of concern relative to potential ground water contamination from fuel fabricating processes.

Please note that other fuel fabricating licensees also use these specific analytes in lieu of total gross alpha/beta. The other change relative to wastewater management system(s) is simply a clarification that Framatome has several subsystems that encompass the wastewater management function.

SNM-1227 section 1.2.4.11 authorizes Framatome to make these types of minor changes without prior NRC approval provided a copy of the change is provided to the Director, Office of Nuclear Material Safety and Safeguards, with a copy to the appropriate NRC Regional Office, within six months after the change is made. This letter with the accompanying attachment fulfills this requirement.

If you have any questions regarding this licensing action, please contact Calvin Manning, of my staff at 509-375-8237 or via email at calvin.manninq@framatome.com.

Additionally, I can be reached at 509-375-8550 or via email at timothv.tate@framatome.com.

Very truly yours, T. J. Tate, Manager Environmental, Health, Safety & Licensing Framatome Inc.

2101 Horn Rapids Road Richland, WA 99354 Tel: (509) 375-8100 www.framatonie.com

USNRC July 14, 2021 TJT:21:016 Page 2 c:

Richard Jervey US Nuclear Regulatory Commission Two White Flint North Mailstop 4A60 11545 Rockville Pike Rockville MD 20852-2738 US Nuclear Regulatory Commission, Region II Attn: Tom Vukovinsky USNRC Region II 245 Peachtree Center Avenue, Suite 1200 Atlanta, GA 30303-1257