FORM APF-05D-001-02, REV. 12 CALCULATION CHANGE NOTICE CCN NO.

XX-E-013 Base Calc No.

004 Rev No.

Page 1 CN008 Sequence No.

CALCULATION TITLE - From CALCULATION TITLE field in EIS:

POST-FIRE SAFE SHUTDOWN (PFSSD) ANALYSIS COMPUTER CODE:

N/A VERSION: N/A Administrative?

YES NO ASSOCIATED ENGINEERING CHANGE #:

13324 REGULATORY REVIEWS:

Attached Attached to:

Not Applicable Evaluation #

13324 N/A Only if Administrative USAR STATEMENT:

Requires a change to the USAR:

Does NOT require a change to the USAR ANY DOCUMENTS IMPACTED?

YES If yes, enter: SWO #, or Condition Report #, if applicable.

NO Status:

COMMITTED FINAL VOID SUPERSEDED ORIG DigsigOrg 2.8, 0.7 Brian Fox Printed Name Signature QUALIFICATION REQUIRED:

7/22/2020 Date ES9280479 ORIG Printed Name Signature QUALIFICATION REQUIRED:

Date ES9280479 VERF DigsigVer 2.8, 0.7 William Wilkins Printed Name Signature QUALIFICATION REQUIRED:

07/22/2020 Date ES9280479 VERF Printed Name Signature QUALIFICATION REQUIRED:

Date ES9280479 APP DigsigApp 2.8, 0.7 Jeff Suter Printed Name Signature 07/22/2020 Date APP Printed Name Signature Date DigsigCert 3.5 1.75 DigsigCert 3.5 1.75 RPE Certification (For ASME Section III Stress Reports/Design Reports, refer to AP 05D-001 for qualification requirements)

CALCULATION SUBJECT (Statement Of Problem) - Enter this in SUBJECT field in EIS:

CP 13324 will replace the 7300 Controls System with a new Ovation DCS components. Changes in PFSSD functional descriptions and components are updated to reflect this change.

Brian R. Fox 2020.07.22 16:21:31 -05'00' Digitally signed by Brian R. Fox Date:

2020.07.22 16:24:40 -05'00'

FORM APF-05D-001-02, REV. 12 CALCULATION DATABASE INPUT CCN NO.

XX-E-013 Base Calc No.

004 Rev No.

Page 2 008 Sequence No.

Link new systems to the calculation/CCN in EIS.

Systems Affected:

BB, PG, PK, PN, RP Develop relationships between interdependent calculations in EIS.

Additional Calculations Providing Input to this calculation:

None Additional Calculations Impacted by this calculation:

None Develop relationships between the calculation/CCN and controlled reference documents in EIS.

Additional Controlled Documents Inputs to this calculation:

M-761A-00019, M-761A-00025, E-13PN02, E-11PK01, E-11PK04 Additional Controlled Documents Impacted by this calculation:

None The reference documents listed below are those that cannot be linked to the calculation/CCN and shall be entered in the INDUSTRY REFERENCE field in EIS, e.g., ASME Codes, ANSI Standards, letters, etc.

Additional Other Reference Documents:

CP 13324, CP 20011 Link new components to the calculation/CCN in EIS.

Additional Components:

NG0410, PG19GCF3, PG20GAF4, PK004, PK014, PK024, PK0105, PK0401, PK0402, PK0407, PN003, PN004, PN310, PN410 (remove BBPK0455A, BBPK0455B, BBPK0455C, BBPS0455F, PG19GAF1, PG20GAF2, PK42, PK4200, PK4207, PK6107, PN001, PN002)

REFER TO DESKTOP GUIDE FOR PROCESSING CALCULATIONS IN EIS

FORM APF-05D-001-02, REV. 12 LIST OF EFFECTIVE PAGES CCN NO.

XX-E-013 Base Calc No.

004 Rev No.

Page 3 008 Sequence No.

CCN Page No.

Calc.

Page Affected DVR/SCRN/

Other CCN Page No.

Calc.

Page Affected

/DVR/SCRN

/Other CCN Page No.

Calc.

Page Affected

/DVR/SCRN

/Other CCN Page No.

Calc.

Page Affected

/DVR/SCRN

/Other 1-5 N/A Att. 1 App. 1 p20-22 App. 3 p28-31, 35, 90, 108-115, 117-118 DVR

= Design Verification Report (if applicable)

SCRN

= Regulatory Screening (if applicable)

AD

= Applicability Determination

FORM APF-05D-001-02, REV. 12 CALCULATION SHEET CCN NO.

XX-E-013 Base Calc. No.

004 Rev. No.

Page 4 008 Sequence No CP 13324 replaces the analog based Westinghouse 7300 Nuclear Steam Supply System (NSSS) with a digital Emerson Ovation Distributed Control System (DCS). The change impacts the PFSSD analysis.

Changes to Calculation XX-E-013 are included in this CCN. Markups are attached.

Calculation Appendix 1 Page 20 Revise per attached markup to describe the operation of the pressurizer PORV controls.

Calculation Appendix 1 Pages 21 and 22 Revise per attached markup to describe the operation of the normal spray valves.

Calculation Appendix 1 Page 22 Revise per attached markup to describe that the PFSSD design of the pressurizer heaters is not affected.

Calculation Appendix 3 Revise per the attached markup.

FORM APF-05D-001-02, REV. 12 ATTACHMENT 1 Page 1 of 20 CCN NO.

XX-E-013 Base Calc No.

004 Rev No.

Page 5 008 Sequence No - XX-E-013 markup

)250$3)'5(9

APPENDIX 1 PFSSD FUNCTION EVALUATIONS (REACTOR MAKEUP)

CALCULATION NO.

REVISION NO.

XX-E-013 4

Page 20 5(/$<

'(6&5,37,21

&200(17

;%%

3UHVVXUL]HU3259%ORFN9DOYH

%%+9$$X[LOLDU\\5HOD\\

,IUHOD\\HQHUJL]HG%%+9$ZLOORSHQ

;%%

3UHVVXUL]HU3259%ORFN9DOYH

%%+9%$X[LOLDU\\5HOD\\

,IUHOD\\HQHUJL]HG%%+9%ZLOORSHQ

.

3UHVVXUL]HU+LJK3UHVVXUH7UDLQ$

,IUHOD\\HQHUJL]HG%%3&9$ZLOORSHQ

.

3UHVVXUL]HU+LJK3UHVVXUH7UDLQ%

,IUHOD\\HQHUJL]HG%%3&9$ZLOORSHQ

%%

3UHVVXUL]HU3259%%3&9$

&RQWDFWRU3DQHO 7ZR$X[LOLDU\\UHOD\\FRQWDFWVLQVHULHVPXVW

EHFORVHGWRLQLWLDWHFORVLQJIRXUFRQWDFWVLQ

VHULHVWRRSHQ%%3&9$

%%

3UHVVXUL]HU3259%%3&9$

&RQWDFWRU3DQHO 7ZR$X[LOLDU\\UHOD\\FRQWDFWVLQVHULHVPXVW

EHFORVHGWRLQLWLDWHFORVLQJIRXUFRQWDFWVLQ

VHULHVWRRSHQ%%3&9$

7KHIROORZLQJFRPSRQHQWVDQGVLJQDOVDUHUHODWHGWRFROGRYHUSUHVVXUHSURWHFWLRQDQGQRWUHTXLUHGIRUSRVWILUH

VDIHVKXWGRZQ%%+6$%%+6%%%=$%%=$$%%=$$%%=6$

%%=6$%%3%&%%39&%%3%(DQG%%3%(

7KHSUHVVXUL]HUSUHVVXUHUHOLHIVLJQDOVIURPWKHVROLGVWDWHSURWHFWLRQV\\VWHP 6636 DUHLQFOXGHGLQWKHSRVW

ILUHVDIHVKXWGRZQGHVLJQ7KHUHDVRQIRULQFOXGLQJWKHVHVLJQDOVLVWKDWLQDGYHUWDQWRSHUDWLRQRIWKHSUHVVXUH

FRQWUROV\\VWHPFRXOGFRPSOLFDWH3)66'E\\FDXVLQJWKHSUHVVXUL]HU3259VDQGVSUD\\YDOYHVWRRSHUDWHWKXV

FDXVLQJDUDSLGGHFUHDVHLQ5&6SUHVVXUHZKLFKFRXOGOHDGWRERLOLQJLQWKHFRUH

)RXUSUHVVXUL]HUSUHVVXUHWUDQVPLWWHUVIHHGVLJQDOVWRWKHSUHVVXUL]HUSUHVVXUHDQGOHYHOFRQWUROV\\VWHPDV

ZHOODVWKHUHDFWRUSURWHFWLRQV\\VWHP 536 7KHVLJQDOVIURPWKHSUHVVXUHWUDQVPLWWHUVSHUIRUPWKHIROORZLQJ

IXQFWLRQVDSSOLFDEOHWR3)66'

x 7ULSVWKHUHDFWRURQ RIKLJKSUHVVXUHDWSVLJ x

&ORVHV3259EORFNYDOYHVRQRIORZSUHVVXUHDWSVLJ x

7ULSVWKHUHDFWRURQRIORZSUHVVXUHDWSVLJ x

6DIHW\\LQMHFWLRQRQRIORZSUHVVXUHDWSVLJ x

2SHQV3259%%3&9$RQVLJQDOIURPWKHSUHVVXUL]HUSUHVVXUHPDVWHUFRQWUROOHU %%3.$ 

7KHQRPLQDORSHQVHWSRLQWLVSVLJIURPHLWKHU%%37RU%%37GHSHQGLQJRQWKH

SRVLWLRQRIWKHSUHVVXUHFKDQQHOVHOHFWRUVZLWFK %%36) 7KHQRUPDOVZLWFKSRVLWLRQLVZLWK

%%37VHOHFWHG

x 2SHQV3259%%3&9$RQVLJQDOIURPSUHVVXUL]HUSUHVVXUHFRQWUROV\\VWHPWKURXJKDELVWDEOHVHW

DWSVLJIURPHLWKHU%%37RU%%37GHSHQGLQJRQWKHSRVLWLRQRIWKHSUHVVXUHFKDQQHO

VHOHFWRUVZLWFK %%36) 7KHQRUPDOVZLWFKSRVLWLRQLVZLWK%%37VHOHFWHG

7KHUHDFWRUWULSVLJQDOVDQGEORFNYDOYHFORVHVLJQDOVDUHQRWVSHFLILFDOO\\GLVFXVVHGLQWKHILUHDUHDDQDO\\VHV

EHFDXVHZLWKWKHUHDFWRUWULSSHGDQGWKHEORFNYDOYHVFORVHGWKHGHVLUHG3)66'FRQGLWLRQLVDFKLHYHG$

VSXULRXVVDIHW\\LQMHFWLRQVLJQDO 6,6 FRPSOLFDWHV3)66'VRWKHILUHDUHDDQDO\\VLVGRFXPHQW () 

DGGUHVVHVDUHDVZKHUHVSXULRXVORZSUHVVXUL]HUSUHVVXUH6,6FDQRFFXU6SXULRXVVLJQDOVIURPWKH

ŽŽ

ŽWsŽ

7KH 2YDWLRQ V\\VWHP XVHV VLJQDO YHULILFDWLRQ IURP DOO IRXU SUHVVXUL]HU SUHVVXUH FKDQQHOV ZLWK WKH QG KLJKHVW SUHVVXUH LQSXW VHOHFWHG DV WKH YDOLGDWHG VLJQDO 7ZR VHSDUDWH IRXUFKDQQHO VLJQDO VHOHFWLRQ VFKHPHV LQ VHSDUDWH 2YDWLRQ GURSV DUH XVHG WR GHYHORS WKH DFWXDWLRQ VLJQDOV IRU WKH 3259V RQH IRU %%3&9$ DQG RQH IRU %%3&9$ $ KRW VKRUW RSHQ FLUFXLW RU VKRUW WR JURXQG RQ D VLQJOH LQSXW FKDQQHO ZLOO UHVXOW LQ WKH VLJQDO IDLOLQJ HLWKHU KLJK RU ORZ,I LW IDLOV WR WKH ORZHVW VHWWLQJ WKHUH LV QR LPSDFW RQ 3)66' EHFDXVH WKH 3259V ZLOO UHPDLQ FORVHG,I LW IDLOV WR WKH KLJKHVW VHWWLQJ WKHUH LV QR LPSDFW EHFDXVH WKH 2YDWLRQ V\\VWHP ZLOO FRQWLQXH WR XVH WKH QG KLJKHVW LQSXW,I WKH 2YDWLRQ V\\VWHP VHQVHV D IDLOHG LQSXW WKH FRQWURO ORJLF ZLOO FKDQJH IURP QG KLJKHVW WR DQ DYHUDJH RI WKH WZR KLJKHVW LQSXWV 3259 %%3&9$ RSHQV ZKHQ YDOLGDWHG SUHVVXUH HTXDOV RU H[FHHGV  SVLJ RYHU VHWSRLQW  SVLJ DQG FORVHV ZKHQ SUHVVXUH UHWXUQV WR  SVLJ RYHU VHWSRLQW 3259

%%3&9$ RSHQV ZKHQ WKH YDOLGDWHG SUHVVXUH H[FHHGV  SVLJ DQG FORVHV ZKHQ SUHVVXUH UHGXFHV WR  SVLJ

)LUH GDPDJH WR WZR RU PRUH LQSXW FKDQQHOV ZRXOG KDYH WR RFFXU DW WKH H[DFW VDPH WLPH DQG IDLO WR WKH H[DFW VDPH YDOXH EXW QRW H[FHHG WKH PD[LPXP 9 YDOXH LQ RUGHU IRU WKH 2YDWLRQ V\\VWHP WR FRQVLGHU WKHP YDOLG DQG VLJQDO WKH 3259V WR RSHQ

7KLV LV QRW FRQVLGHUHG D FUHGLEOH VFHQDULR DQG LV QRW FRQVLGHUHG SRVVLEOH LQ WKH ILUH DUHD DQDO\\VLV

CCN XX-E-013-004-CN008 Page 2 of 20

)250$3)'5(9

APPENDIX 1 PFSSD FUNCTION EVALUATIONS (REACTOR MAKEUP)

CALCULATION NO.

REVISION NO.

XX-E-013 4

Page 21 SUHVVXUL]HUSUHVVXUHFRQWUROV\\VWHPFRXOGFDXVHRQHRUERWKSUHVVXUL]HU3259VWRRSHQZKLFKLVQRWGHVLUHG

IRU3)66'7KHUHIRUHWKHVHSUHVVXUHVLJQDOVDUHHYDOXDWHGLQWKHILUHDUHDDQDO\\VLVGRFXPHQW () 



5&6&RROGRZQ5DWH&RQWURO5&6FRROGRZQUDWHFRQWUROLQFOXGHVSUHYHQWLRQRIXQFRQWUROOHG5&6FRROGRZQ

DQGFRQWUROOLQJ 5&6FRROGRZQUDWHGXULQJGHFD\\KHDWUHPRYDO

D

8QFRQWUROOHG5&6&RROGRZQ0DLQVWHDPFRPSRQHQWVWKDWFRXOGLQLWLDWHXQFRQWUROOHG5&6FRROGRZQDUH

FRQWUROOHG LVRODWHG &RQWURORIWKHVHPDLQVWHDPFRPSRQHQWV VWHDPJHQHUDWRUDWPRVSKHULFUHOLHIYDOYHV

06,9VDQG06,9E\\SDVVYDOYHV LVGHVFULEHGLQWKHUHDFWLYLW\\FRQWUROIXQFWLRQGLVFXVVLRQ

E

&RQWURORI5&6&RROGRZQ5DWH0DLQVWHDPFRPSRQHQWV VWHDPJHQHUDWRUDWPRVSKHULFUHOLHIYDOYHV XVHG

WRFRQWURO5&6FRROGRZQDUHGHVFULEHGLQWKHGHFD\\KHDWUHPRYDOIXQFWLRQGLVFXVVLRQ

0DLQVWHDPOLQHSUHVVXUHWUDQVPLWWHUVSURYLGHDVWHDPOLQHSUHVVXUHLQSXWVLJQDOWRWKHVDIHW\\LQMHFWLRQFLUFXLWV

6DIHW\\LQMHFWLRQFRPSOLFDWHVFRQWURORIWKHUHDFWLYLW\\FRQWUROIXQFWLRQ H[FHVVLYHFRROGRZQLQVHUWVSRVLWLYH

UHDFWLYLW\\ UHDFWRUPDNHXSIXQFWLRQ SUHVVXUL]HUOHYHOPD\\QRWEHPDLQWDLQHGZLWKLQLQGLFDWLQJUDQJH DQGGHFD\\

KHDWUHPRYDO H[FHVVLYHFRROGRZQUDWH 6DIHW\\LQMHFWLRQLVFRQWUROOHGE\\HLWKHUSUHYHQWLQJVDIHW\\LQMHFWLRQ

DFWXDWLRQ SURWHFWLQJ6,LQSXWVLJQDOVDQGRURSHQLQJVDIHW\\LQMHFWLRQSXPSEUHDNHUVWRSUHYHQWVDIHW\\LQMHFWLRQ

SXPSVIURPUXQQLQJ &RQVHTXHQWO\\WKHIROORZLQJVWHDPOLQHSUHVVXUHWUDQVPLWWHUVDUHLQFOXGHGLQWKHSRVWILUH

VDIHVKXWGRZQGHVLJQ

&20321(17

'(6&5,37,21

$%37

6WHDP*HQHUDWRU$6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU$6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU$6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU%6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU%6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU%6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU&6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU&6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU&6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU'6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU'6WHDPOLQH3UHVVXUH7UDQVPLWWHU

$%37

6WHDP*HQHUDWRU'6WHDPOLQH3UHVVXUH7UDQVPLWWHU



1RUPDODQG$X[LOLDU\\3UHVVXUL]HU6SUD\\$QRWKHUHOHPHQWUHTXLUHGWRDVVXUH5&6SUHVVXUHFRQWUROIXQFWLRQV

DUHDYDLODEOHLVFRQWURORIQRUPDODQGDX[LOLDU\\SUHVVXUL]HUVSUD\\%HFDXVHQRUPDOSUHVVXUL]HUVSUD\\UHOLHV

XSRQWKHSUHVVXUHGLIIHUHQWLDOEHWZHHQWKHVXUJHOLQHFRQQHFWLRQLQWKH/RRSKRWOHJDQGWKHVSUD\\OLQH

FRQQHFWLRQLQWKH/RRSVDQGFROGOHJQRUPDOSUHVVXUL]HUVSUD\\LVFRQWUROOHG VWRSSHG LIWKH5&3VDUHQRW

UXQQLQJ,IOHVVWKDQIRXU5&3VDUHRSHUDWLQJWKHSUHVVXUL]HUVSUD\\IORZZLOOEHUHGXFHGLIWKH'5&3LVQRW

RSHUDWLQJEHFDXVHWKHVWDWLFSUHVVXUHLQWKHVXUJHOLQHORRSZLOOEHQHDUO\\HTXDOWRWKHVSUD\\VRXUFHORRS7KH

QRUPDOSUHVVXUL]HUVSUD\\YDOYHVDUHDLURSHUDWHG,VRODWLRQRILQVWUXPHQWDLUWRFRQWDLQPHQWZLOOIDLOWKHYDOYHV

FORVHG2)153SURYLGHVDFWLRQVWRVWRSWKH5&3VZLWKLQWKHILUVWVHYHQ PLQXWHVIROORZLQJFRQWUROURRP

HYDFXDWLRQLQWKHHYHQWRIDFRQWUROURRPILUH,QWKHHYHQWRIDILUHRXWVLGHWKHFRQWUROURRPRSHUDWRUVFDQ

PLWLJDWHVSXULRXVRSHUDWLRQRIWKHSUHVVXUL]HUVSUD\\YDOYHVE\\HLWKHUVWRSSLQJWKH5&3VDQGXVLQJQDWXUDO

FLUFXODWLRQFRROGRZQRULVRODWLQJLQVWUXPHQWDLUWRFRQWDLQPHQWWRIDLOWKHYDOYHVFORVHG 9DOYH.$)9DQG

KDQGVZLWFK.$+,6DUHLQFOXGHGLQWKH3)66'GHVLJQWRLVRODWHLQVWUXPHQWDLUWRFRQWDLQPHQW9DOYH

.$9LVDOVRLQFOXGHGLQWKH3)66'GHVLJQ LQ WKHHYHQW.$)9LVDIIHFWHGE\\WKHILUH 7KHUHIRUH

SUHVVXUL]HUQRUPDOVSUD\\YDOYHV%%3&9%DQG%%3&9&DQGDVVRFLDWHGFDEOHVDQGFRPSRQHQWVDUH

LQFOXGHGLQWKH3)66'$WRHYDOXDWHZKHWKHUWKHVSUD\\YDOYHVZLOOVSXULRXVO\\RSHQ dŽŽŽŽKŽŽŽdŽ

ŽŽŽŽŽŽtŽŽtŽ

E^^^ŽŽŽŽŽŽKŽŽŽ

ŽŽWdWdWdWddŽŽ

ŽŽŽŽŽŽŽŽŽŽŽŽŽ

ŽdŽŽŽŽŽ

dŽŽŽW&^^ŽŽŽŽŽ



CCN XX-E-013-004-CN008 Page 3 of 20

)250$3)'5(9

APPENDIX 1 PFSSD FUNCTION EVALUATIONS (REACTOR MAKEUP)

CALCULATION NO.

REVISION NO.

XX-E-013 4

Page 22 7KHSUHVVXUL]HUQRUPDOVSUD\\YDOYHV %%3&9%DQG%%3&9& RSHUDWHRIIDVLJQDOIURPWKH

SUHVVXUL]HUSUHVVXUHFRQWUROV\\VWHP7KHSUHVVXUL]HUSUHVVXUHPDVWHUFRQWUROOHU %%3.$ UHFHLYHVD

VLJQDOIURPHLWKHU%%37RU%%37GHSHQGLQJRQWKHSRVLWLRQRIWKHSUHVVXUHFKDQQHOVHOHFWRUVZLWFK

%%36) 7KHQRUPDOSRVLWLRQRIWKHVZLWFKKDV%%37VHOHFWHG6ZLWFK%%36)LVFRQQHFWHGWR

UHOD\\FDUGVLQSDQHO53/RVVRISRZHUWRWKHUHOD\\FDUGVZLOOFDXVHWKHVZLWFKWRUHYHUWWRWKH

%%37%%37SRVLWLRQ,I%%37LVDIIHFWHGE\\WKHILUHRSHUDWRUVFDQVZLWFKWR%%37RQO\\LI

SRZHUWRWKHUHOD\\FDUGVLVDYDLODEOH7KHUHIRUHSRZHUWR53LVLQFOXGHGLQWKH3)66'DQDO\\VLV

8SRQLQFUHDVLQJSUHVVXUHLQWKHSUHVVXUL]HUDVGHWHUPLQHGE\\WKHPDVWHUFRQWUROOHUWKHVSUD\\YDOYHVRSHQWR

FRPSHQVDWHIRUWKHSUHVVXUHLQFUHDVH$W:ROI&UHHNRQHVHWRISUHVVXUL]HUEDFNXSKHDWHUVLVQRUPDOO\\

PDLQWDLQHGHQHUJL]HG7KLVFDXVHVWKHPDVWHUFRQWUROOHURXWSXWWRLQFUHDVHDVSUHVVXUHJRHVXS7KLVRXWSXW UHVXOWVLQWKHSUHVVXUL]HUVSUD\\YDOYHVRSHQLQJWRFRPSHQVDWHIRUWKHKHDWLQSXWWRWKHSUHVVXUL]HU7KHHQG

UHVXOWLV5&6IOXLGIURPWKHVSUD\\OLQHVFRQWLQXDOO\\PL[LQJLQWKHSUHVVXUL]HUPDLQWDLQLQJWKHERULFDFLGDQG

FKHPLFDOFRQFHQWUDWLRQVHTXDOWRWKH5&6

3UHVVXUL]HUDX[LOLDU\\VSUD\\YDOYH%*+9LVQRWLQFOXGHGLQWKHSRVWILUHVDIHVKXWGRZQGHVLJQEHFDXVH

DOWHUQDWLYHDQGUHGXQGDQWPHDQVDUHDYDLODEOHWRSUHYHQWDX[LOLDU\\VSUD\\7KHSUHVVXUL]HUDX[LOLDU\\VSUD\\WDSLV

RQWKHFKDUJLQJOLQHGRZQVWUHDPRIWKHUHJHQHUDWLYHKHDWH[FKDQJHU7KHUHIRUHLVRODWLRQRIWKHQRUPDO

FKDUJLQJOLQHZLOOSUHYHQWDX[LOLDU\\SUHVVXUL]HUVSUD\\,Q2)153QRUPDOFKDUJLQJLVLVRODWHGE\\FORVLQJ

%*%)RUILUHVRXWVLGHWKHFRQWUROURRPQRUPDOFKDUJLQJLVLVRODWHGE\\FORVLQJHLWKHU%*+9RU

%*+9+RZHYHULQRQHILUHDUHD $ LWPD\\QRWEHSRVVLEOHWRFORVHYDOYHV%*+9DQG

%*+9EHFDXVHWKHVHYDOYHVDUHORFDWHGLQILUHDUHD$DQGDILUHFRXOGGDPDJHWKHSRZHUFDEOHV6HH

ILUHDUHD$DQDO\\VLVLQ()IRUIXUWKHUGLVFXVVLRQDERXWWKLVFRQILJXUDWLRQ



3UHVVXUL]HU+HDWHUV3UHVVXUL]HUKHDWHUVDUHQRWFUHGLWHGLQWKHUHGXQGDQWSRVWILUHVDIHVKXWGRZQGHVLJQ 

&)5$SSHQGL[56HFWLRQ,,,*DUHDV &DOFXODWLRQ:&12&&3LVDWKHUPDOK\\GUDXOLFWUDQVLHQW

DQDO\\VLVIRUWKH:ROI&UHHNSODQWIRUYDULRXVILUHVFHQDULRV7KHSUHVVXUL]HUKHDWHUVZHUHPRGHOHGRQRURIIIRU

HDFKVFHQDULRWRGHWHUPLQHZRUVHFDVHHIIHFW%DVHGRQWKHUHVXOWVRSHUDWLRQRUPDORSHUDWLRQRIWKH

SUHVVXUL]HUKHDWHUVKDGQRDGYHUVHLPSDFWRQ3)66'$Q\\PLQLPDOLPSDFWFRXOGEHRIIVHWE\\DYDLODEOH

3)66'HTXLSPHQW7KHUHIRUHWKHSUHVVXUL]HUKHDWHUVDUHQRWLQFOXGHGLQWKH3)66'DQDO\\VLV

7KHEDFNXSJURXS%SUHVVXUL]HUKHDWHUVDUHFUHGLWHGLQWKHDOWHUQDWLYHSRVWILUHVDIHVKXWGRZQGHVLJQ &)5

$SSHQGL[56HFWLRQ,,,*DUHDV 3URFHGXUH2)153KDVRSHUDWRUVPDLQWDLQSUHVVXUL]HUSUHVVXUH

ZLWKLQDFFHSWDEOHSDUDPHWHUV7KLVLVGRQHE\\F\\FOLQJWKHEDFNXSJURXS%KHDWHUVRQDQGRIIDVQHFHVVDU\\

&DOFXODWLRQ6$DVVXPHVWKHSUHVVXUL]HUEDFNXSJURXS%KHDWHUVDUHFRQWUROOHGLQ2)153ZLWKLQ

PLQXWHVIROORZLQJUHDFWRUWULS7KHEDFNXSJURXS%KHDWHUVDUHLVRODWHGIURPWKHFRQWUROURRPXVLQJ

53+,6RQSDQHO53%+DQGVZLWFK%%+,6%FRQWUROVWKHSRVLWLRQRILQFRPLQJ3*IHHGHU

EUHDNHU3*IURPDX[LOLDU\\VKXWGRZQSDQHO53%%XV3*LVWKHSRZHUGLVWULEXWLRQEXVIRUWKH

EDFNXSJURXS%KHDWHUV%XV3*LVIHGIURP1%7KHVHFRPSRQHQWVDUHLQFOXGHGLQWKHDOWHUQDWLYH

3)66' GHVLJQ



3UHVVXUL]HU3UHVVXUH,QGLFDWLRQ3UHVVXUL]HUSUHVVXUHLQGLFDWLRQLVLQFOXGHGLQWKH3)66'GHVLJQWRSURYLGH

RSHUDWRUVZLWKDZD\\RIGLDJQRVLQJDQRSHQ3259EORFNYDOYHIORZSDWKRUVSXULRXVSUHVVXUL]HUVSUD\\7KH

IROORZLQJSUHVVXUL]HUSUHVVXUHLQGLFDWRUVDUHLQFOXGHG

&20321(17

'(6&5,37,21

%%3,$

3UHVVXUL]HU3UHVVXUH,QGLFDWRU

%%3,

3UHVVXUL]HU3UHVVXUH,QGLFDWRU

%%3,

3UHVVXUL]HU3UHVVXUH,QGLFDWRU

%%3,

3UHVVXUL]HU3UHVVXUH,QGLFDWRU

)LUH GDPDJH WR WZR RU PRUH LQSXW FKDQQHOV ZRXOG KDYH WR RFFXU DW WKH H[DFW VDPH WLPH DQG IDLO WR WKH H[DFW VDPH YDOXH EXW QRW H[FHHG WKH PD[LPXP 9 YDOXH LQ RUGHU IRU WKH 2YDWLRQ V\\VWHP WR FRQVLGHU WKHP YDOLG DQG VLJQDO WKH VSUD\\ YDOYHV WR RSHQ 7KLV LV QRW FRQVLGHUHG D FUHGLEOH VFHQDULR DQG LV QRW FRQVLGHUHG SRVVLEOH LQ WKH ILUH DUHD DQDO\\VLV

dW&^^ŽŽKŽE^^^

ŽŽ^^

CCN XX-E-013-004-CN008 Page 4 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

BBLI0460B 2

Pressurizer Level Indicator (Narrow Range) 1413S A-28 RP118B M

X X

X M-12BB02 E-13SB09 E-03SB16 M-761-00076 M-761-00495 M-761-02304 NN0217 XX-E-013-001-CN004 2

BBLT0459 1

Pressurizer Level Transmitter (Narrow Range)

RB4 RB-4 M

X X

X M-12BB02 E-13BB16 E-13SB09 M-761-00042 M-761-00076 M-761-2019 NN0111 0

BBLT0460 2

Pressurizer Level Transmitter (Narrow Range)

RB4 RB-4 M

X X

X X

M-12BB02 E-13BB16 E-13SB09 M-761-00076 M-761-00495 M-761-02304 NN0217 0

BBPB0403A 2

Reactor Coolant Sys Press Wide Range Hot Leg 3605 C-27 SB042 H

X X

X M-12BB04 E-13BB15 E-13NN01 E-13SB09 M-761-00101 NN0212 Required for cold shutdown - If control room not accessible or circuit damaged, locally open BBPV8702B 0

BBPB0405A 1

Reactor Coolant Sys Press Wide Range Hot Leg 3605 C-27 SB038 H

X X

X M-12BB04 E-13BB15 E-13NN01 E-13SB09 M-761-00101 NN0111 For alternate shutdown, locally operate EJHV8701B to transition to cold shutdown 0

BBPCV0455A 1

Pressurizer Power Operated Relief Valve RB-10 RB-10 M

X X

X X

M-12BB02 E-13BB39 E-13BB40 E-11NK01 NK5108 XX-E-013-002-CN002 XX-E-013-003-CN006 4

BBPCV0455B 5

Pressurizer Spray Valve RB-10 RB-10 M

X X

X X

M-12BB02 E-13BB19 PG19GCR218 PN001 XX-E-013-003-CN006 4

BBPCV0455C 5

Pressurizer Spray Valve RB-10 RB-10 M

X X

X X

M-12BB02 E-13BB19 PG19GCR218 PN001 XX-E-013-003-CN006 4

BBPCV0456A 4

Pressurizer Power Operated Relief Valve RB-10 RB-10 M

X X

X X

M-12BB02 E-13BB39 E-13BB40 E-11NK02 NK4421 XX-E-013-002-CN002 XX-E-013-003-CN006 4

BBPI0405 1

Reactor Coolant Sys Press Wide Range Hot Leg 3601 C-27 RL022 H

X X

X M-12BB04 E-13BB15 E-13NN01 E-13SB09 M-761-00101 NN0111 0

BBPI0406 4

Reactor Coolant Sys Press Wide Range Hot Leg 3601 C-27 RL022 H

X X

X M-12BB04 E-13BB16 E-13NN01 E-13SB09 M-761-00496 M-761-00101 NN0420 0

BBPI0406X 4

Reactor Coolant Sys Press Wide Range Hot Leg 1413S A-28 RP118B H

X X

X M-12BB04 E-13BB16 E-13NN01 E-13SB09 E-13SB16 M-761-00496 NN0420 XX-E-013-001-CN004 XX-E-013-001-CN011 2

D

D

WE

WE WE

WE CCN XX-E-013-004-CN008 Page 5 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

BBPI0455A 5

Pressurizer Pressure Indicator 3601 C-27 RL002 S

M X

X X

M-12BB02 E-13SB08A J-200-00095 M-761-00133 M-761-02018 NN0111 2

BBPI0456 6

Pressurizer Pressure Indicator 3601 C-27 RL002 S

M X

X X

M-12BB02 E-13SB08A J-200-00095 M-761-00135 M-761-02048 NN0212 2

BBPI0457 5

Pressurizer Pressure Indicator 3601 C-27 RL002 S

M X

X X

M-12BB02 E-13SB08B J-200-00095 M-761-00137 M-761-02079 NN0311 2

BBPI0458 6

Pressurizer Pressure Indicator 3601 C-27 RL002 S

M X

X X

M-12BB02 E-13SB08B J-200-00095 M-761-00139 M-761-02102 NN0414 2

BBPK0455A 5

Pressurizer Master Controller 3601 C-27 RL002 M

X X

X E-13SC03 J-200-00095 M-761-00141 M-761-02127 PG19GCR218 PN001 2

BBPK0455B 5

BBPCV0455B Auto/Manual Controller 3601 C-27 RL002 M

X X

X E-13SC03 J-200-00095 M-761-00141 M-761-02128 PG19GCR218 PN001 2

BBPK0455C 5

BBPCV0455C Auto/Manual Controller 3601 C-27 RL002 M

X X

X E-13SC03 J-200-00095 M-761-00141 M-761-02129 PG19GCR218 PN001 2

BBPS0455F 6

Pressure Channel Selector Switch 3601 C-27 RL002 M

X X

X E-13SC01 J-200-00095 M-761-00142 PG20GBR219 PN002 2

BBPT0403 2

Reactor Coolant Sys Press Wide Range Hot Leg 1202 A-1 H

X X

X M-12BB04 E-13BB12A E-13BB12B E-13BB15 E-13NN01 E-13SB02 E-13SB09 M-761-00101 NN0212 Required for cold shutdown - If control room not accessible or circuit damaged, locally open BBPV8702B 0

BBPT0405 1

Reactor Coolant Sys Press Wide Range Hot Leg 1320 A-8 H

X X

X X

M-12BB04 E-13BB15 E-13NN01 E-13SB01 E-13SB08D E-13SB09 M-761-00101 NN0111 For alternate shutdown, locally operate EJHV8701B to transition to cold shutdown 0

BBPT0406 4

Reactor Coolant Sys Press Wide Range Hot Leg 1202 A-1 H

X X

X X

M-12BB04 E-13BB16 E-13NN01 E-13SB09 M-761-00101 M-761-00496 NN0420 0

CCN XX-E-013-004-CN008 Page 6 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

BBPT0455 1

Pressurizer Pressure Transmitter RB4 RB-4 S

X X

X X

M-12BB02 E-13BB16 E-13NN01 E-13SB09 E-13SB01 E-13SB02 M-761-00042 M-767-00347 M-761-02018 NN0111 Safety Injection could be initiated by low pressurizer pressure.

0 BBPT0456 2

Pressurizer Pressure Transmitter RB4 RB-4 S

X X

X X

M-12BB02 E-13BB16 E-13NN01 E-13SB09 E-13SB01 E-13SB02 M-761-00043 M-767-00347 M-761-02048 NN0212 Safety Injection could be initiated by low pressurizer pressure.

0 BBPT0457 3

Pressurizer Pressure Transmitter RB10 RB-10 S

X X

X X

M-12BB02 E-13BB16 E-13NN01 E-13SB09 E-13SB01 E-13SB02 M-761-00044 M-767-00347 M-761-02079 NN0311 Safety Injection could be initiated by low pressurizer pressure.

0 BBPT0458 4

Pressurizer Pressure Transmitter RB10 RB-10 S

X X

X X

M-12BB02 E-13BB16 E-13NN01 E-13SB09 E-13SB01 E-13SB02 M-761-00044 M-767-00347 M-761-02102 NN0414 Safety Injection could be initiated by low pressurizer pressure.

0 BBPV8702A 4

RCS Hot Leg 1 to RHR Pump A Suction Iso Vlv RB1 RB-1 M, H X

X X

X M-12BB01 E-13BB12A NG02BCF2 High Low Pressure Interface -

Valve administratively controlled closed - Manually open valve to transition to cold shutdown if interlock not functional 0

BBPV8702B 4

RCS Hot Leg 4 to RHR Pump B Suction Iso Vlv RB1 RB-1 M, H X

X X

X M-12BB01 E-13BB12B NG02BBF3 High Low Pressure Interface -

Valve administratively controlled closed - Manually open valve to transition to cold shutdown if interlock not functional 0

BBPY0455BA 5

Pressurizer Spray Valve BBPCV0455B I/P Converter RB-10 RB-10 M

X X

X X

M-12BB02 E-13BB19 PG19GCR218 PN001 XX-E-013-003-CN006 4

WE

WE CCN XX-E-013-004-CN008 Page 7 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

BBPY0455CA 5

Pressurizer Spray Valve BBPCV0455C I/P Converter RB-10 RB-10 M

X X

X X

M-12BB02 E-13BB19 PG19GCR218 PN001 XX-E-013-003-CN006 4

BBTE0413A 1

RCS Hot Leg Temp Element (WR) Loop 1 RB1 RB-1 H

X X

X M-12BB01 E-13BB15 E-13NN01 E-13SB09 M-761-00042 M-761-00070 NN0111 0

BBTE0413B 2

RCS Cold Leg Temp Element (WR) Loop 1 RB1 RB-1 H

X X

X M-12BB01 E-13BB15 E-13NN01 E-13SB09 M-761-00043 M-761-00071 NN0212 0

BBTE0423A 1

RCS Hot Leg Temp Element (WR) Loop 2 RB1 RB-1 H

X X

X M-12BB01 E-13BB15 E-13NN01 E-13SB09 M-761-00042 NN0111 0

BBTE0423B 2

RCS Cold Leg Temp Element (WR) Loop 2 RB1 RB-1 H

X X

X X

M-12BB01 E-13BB15 E-13NN01 E-13SB09 M-761-00071 NN0217 0

BBTE0433A 2

RCS Hot Leg Temp Element (WR) Loop 3 RB1 RB-1 H

X X

X M-12BB01 E-13BB15 E-13NN01 E-13SB09 M-761-00043 NN0212 0

BBTE0433B 1

RCS Cold Leg Temp Element (WR) Loop 3 RB1 RB-1 H

X X

X M-12BB01 E-13BB15 E-13NN01 E-13SB09 M-761-00042 NN0111 0

BBTE0443A 2

RCS Hot Leg Temp Element (WR) Loop 4 RB1 RB-1 H

X X

X X

M-12BB01 E-13BB15 E-13NN01 E-13SB09 M-761-00071 NN0217 0

BBTE0443B 1

RCS Cold Leg Temp Element (WR) Loop 4 RB1 RB-1 H

X X

X M-12BB01 E-13BB15 E-13NN01 E-13SB09 M-761-00042 NN0111 0

BBTI0413A 1

RCS Hot Leg Temp Indicator (WR) Loop 1 3601 C-27 RL021 H

X X

X M-12BB01 E-13BB15 E-13NN01 E-13SB08D E-13SB09 M-761-00070 NN0111 0

BBTI0413B 2

RCS Cold Leg Temp Indicator (WR) Loop 1 3601 C-27 RL021 H

X X

X M-12BB01 E-13BB15 E-13NN01 E-13SB08D E-13SB09 M-761-00071 NN0212 0

BBTI0423A 1

RCS Hot Leg Temp Indicator (WR) Loop 2 3601 C-27 RL021 H

X X

X M-12BB01 E-13BB15 E-13NN01 E-13SB09 M-761-00070 NN0111 0

WE

WE CCN XX-E-013-004-CN008 Page 8 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

BGHV8153B 4

Excess Letdown/RCS Isolation Valve RB1 RB-1 M

X X

X X

M-12BG01 E-13BG48 E-13RL02 NK4407 High Low Pressure Interface -

Valve fails closed with power removed 0

BGHV8154A 1

Excess Letdown/RCS Isolation Valve RB1 RB-1 M

X X

X X

M-12BG01 E-13BG48 E-13RL02 NK4119 High Low Pressure Interface -

Valve fails closed with power removed 0

BGHV8154B 4

Excess Letdown/RCS Isolation Valve RB1 RB-1 M

X X

X X

M-12BG01 E-13BG48 E-13RL02 NK4407 High Low Pressure Interface -

Valve fails closed with power removed 0

BGHV8357A 1

CCP A Discharge to RCP Seals Valve 1114 A-2 R, M X

X X

M-12BG03 E-13BG52 NG01AGR4 0

BGHV8357B 4

CCP B Discharge to RCP Seals Valve 1107 A-4 R, M X

X X

X M-12BG03 E-13BG52 NG02ADR5 0

BGHY0459 5

BGLCV0459 Solenoid Valve RB9 RB-9 M

X X

X X

M-12BG01 E-13BG10 E-13RL02 PK5117 0

BGHY0460 5

BGLCV0460 Solenoid Valve RB9 RB-9 M

X X

X X

M-12BG01 E-13BG10 E-13RL02 PK5117 0

BGLCV0112B 1

VCT Iso Vlv from Charging Pump Suction Valve 1318 A-8 R, M X

X X

M-12BG03 E-13BG12 NG01AFF2 0

BGLCV0112C 4

VCT Iso Vlv from Charging Pump Suction Valve 1318 A-8 R, M X

X X

X M-12BG03 E-13BG12A NG02AFR2 0

BGLCV0459 5

Letdown Isolation Valve RB9 RB-9 M

X X

X X

M-12BG01 E-13BG10 E-13RL02 PK5117 High / Low Pressure Interface 0

BGLCV0459X 5

Pressurizer Low Level Transistor 3605 C-27 RP043 M

X X

X M-12BG01 E-13BG10 PK5117 PN01 PG19GCR218 0

BGLCV0460 5

Letdown Isolation Valve RB9 RB-9 M

X X

X X

M-12BG01 E-13BG10 E-13RL02 PK5117 High / Low Pressure Interface 0

BGLCV0460X 5

Pressurizer Low Level Transistor 3605 C-27 RP043 M

X X

X M-12BG01 E-13BG10 PK5117 PN01 PG19GCR218 0

BGLT0112 1

VCT Level Transmitter 1318 A-8 R, M X

X X

M-12BG03 E-13BG51 E-13SB09 M-761-00042 NN0111 If charging pump suction fails to shift to RWST, locally open BNLCV0112D and close BGLCV0112B 0

Z Z

WE

WE D

D

WE

WE D

D

CCN XX-E-013-004-CN008 Page 9 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

NG03DEF110 1

Electro Hydraulic Damper Actuator (GMTZ1A) 5203 D-1 S

R, M, H X

X X

E-11NG21 NG03D XX-E-013-003-CN006 4

NG03DEF111 1

Electro Hydraulic Damper Actuator (GMTZ1B) 5203 D-1 S

R, M, H X

X X

E-11NG21 NG03D XX-E-013-003-CN006 4

NG03DEF4 1

Emergency Fuel Oil Xfer Pump Motor (DPJE01A) 5203 D-1 S

R, M, H X

X X

E-13JE01 E-11NG20 NG03D XX-E-013-003-CN006 4

NG03T 1

480V Class 1E Motor Control Center 1410 A-18 S

R, M, H X

X X

E-03NG01 E-11NG01 NG0305 0

NG03TAF1 1

Containment Cooler Fan Motor (DSGN01C) 1410 A-18 S

R, M, H X

X X

X E-13GN02 E-03NG01 E-11NG20 NG0305 0

NG04 4

480V Class 1E Load Center 3302 C-10 S

R, M, H X

X X

X E-01NB02 E-13NB05 E-03NG01 E-11NG02 KD-7496 XNG04 0

NG0401 4

480V Class 1E Load Center Incoming Feeder 3302 C-10 S

R, M, H X

X X

X E-11NG02 E-13NG01A E-13NG11A KD-7496 XNG04 XX-E-013-001-CN011 2

NG0403 4

125VDC Class 1E Battery Charger (NK22) 3302 C-10 S

R, M, H X

X X

X E-11NG02 NG04 0

NG0405 4

480V Class 1E MCC (NG04T) 3302 C-10 S

R, M, H X

X X

X E-11NG02 NG04 0

NG0406 4

480V Class 1E Auxiliary Building MCC (NG04C) 3302 C-10 S

R, M, H X

X X

X E-11NG02 NG04 0

NG0407 4

480V Class 1E Diesel Gen Room MCC (NG04D) 3302 C-10 S

R, M, H X

X X

X E-03NG01 E-11NG02 NG04 0

NG0409 4

125VDC Non-Class 1E Battery Charger (PK22) 3302 C-10 S

R, M, H X

X X

E-11NG02 NG04 0

NG0411 4

125VDC Class 1E Swing Battery Charger (NK26) 3302 C-10 S

R, M, H X

X X

E-11NG02 NG04 0

NG04C 4

480V Class 1E Auxiliary Building MCC 1501 A-21 S

R, M, H X

X X

X E-03NG01 E-11NG02 NG0406 0

NG04CCF2 4

MDAFWP B Discharge to SG B Vlv - 120V (ALHV0005) 1501 A-21 S

H X

X X

X E-13AL09 E-11NG20 NG04C 0

E'sEŽ^,yyyE'E'

W<

CCN XX-E-013-004-CN008 Page 10 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

PG12KAF5 6

Main Steam to Steam Seal Iso Valve (ABHV0046) 4401W TURB S

R, H X

X X

E-13AB22 E-11PG20 PG12K Needed for MSIV failure, fire in A-15 or A-23 2

PG12KAF6 6

480V Non-Class 1E Load Center Incoming Feeder 4401W TURB S

R, H X

X X

E-13PBG03 E-11PG20 PG1207 Needed for MSIV failure, fire in A-15 or A-23 2

PG12KEF3 6

Main Steam Iso to Aux Steam Reboiler (FBHV0080) 4401W TURB S

R, H X

X X

E-13FB12 E-11PG20 PG12K Needed for MSIV failure, fire in A-15 or A-23 2

PG1300 5

480V Non-Class 1E LC Feeder from PA0105 4401W TURB S

R, H X

X X

E-13PG01 KD-7496 PA0105 Needed for MSIV failure, fire in A-15 or A-23 0

PG1400 6

480V Non-Class 1E LC Feeder from PA0207 4401W TURB S

R, H X

X X

E-13PG04 KD-7496 PA0207 Needed for MSIV failure, fire in A-15 or A-23 0

PG1500 5

480V Non-Class 1E LC Feeder from PA0106 4401W TURB S

R, H X

X X

E-13PG02 PA0106 Needed for MSIV failure, fire in A-15 or A-23 0

PG1600 6

480V Non-Class 1E LC Feeder from PA0206 4401W TURB S

R, H X

X X

E-13PG03 KD-7496 PA0206 Needed for MSIV failure, fire in A-15 or A-23 0

PG19 5

480V Non-Class 1E Load Center 1314 A-8 S

R, M, H X

X X

X E-13PG02 KD-7496 XPG19 0

PG1900 5

480V Non-Class 1E LC Feeder from PG1500 1314 A-8 S

R, H X

X X

E-13PG02 PG1500 Needed for MSIV failure, fire in A-15 or A-23 0

PG1901 5

480V Non-Class 1E Load Center Incoming Feeder 1314 A-8 S

R, H X

X X

E-13PG02 KD-7496 XPG19 Needed for MSIV failure, fire in A-15 or A-23 0

PG1907 5

480V Non-Class 1E Auxiliary Bldg MCC (PG19G) 1314 A-8 S

R, M, H X

X X

X E-13PG02 PG19 0

PG19G 5

480V Non-Class 1E Auxiliary Building MCC 1403 A-27 S

R, M, H X

X X

X E-13PG02 E-11PG20 PG1907 2

PG19GAF1 5

5KVA Process Control Inverter (PN01) 1403 A-27 S

M X

X X

X E-13SC12 E-11PG20 PG19G 2

PG19GAF8 5

Incoming Line from Load Center PG19 1403 A-27 S

R, H X

X X

E-13PG02 E-11PG20 PG1907 2

PG19GCR2 5

480VAC Non-Class 1E Distribution Panel 1403 A-27 S

R, M, H X

X X

X E-11PG21 E-13AB04 E-13AB18 E-13RL07 E-13PG02 E-11PG20 PG19G 2

W&sEŽdŽ^,yyyWEW'W

WE

CCN XX-E-013-004-CN008 Page 11 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

PG19GCR217 5

MCB Misc. Power Circuits (RL023) 1403 A-27 S

R, H X

X X

E-13AB04 E-13AB18 E-13RL07 E-13PG02 E-11PG20 PG19G Needed for MSIV failure, fire in A-15 or A-23 2

PG19GCR218 5

Process Control Rack - Group 1 (RP043) 1403 A-27 S

M X

X X

E-13PG02 E-11PG20 PG19G 2

PG19GFR3 5

Instr Bus Transformer - Alt.

Feed (XPN07D) 1403 A-27 S

H X

X X

E-13PN01 E-11PG20 PG19G 2

PG20 6

480V Non-Class 1E Load Center 1403 A-27 S

R, H X

X X

E-13PG04 E-13PA13 KD-7496 XPG20 0

PG2000 6

480V Non-Class 1E LC Feeder from PG2400 1403 A-27 S

R, H X

X X

E-13PG04 KD-7496 PG2400 Needed for MSIV failure, fire in A-15 or A-23 0

PG2001 6

480V Non-Class 1E Load Center Incoming Feeder 1403 A-27 S

R, H X

X X

E-13PA13 KD-7496 XPG20 Needed for MSIV failure, fire in A-15 or A-23 0

PG2008 6

480V Non-Class 1E Auxiliary Bldg MCC (PG20G) 1403 A-27 S

R, H X

X X

E-13PG04 E-13PA13 PG20 0

PG20G 6

480V Non-Class 1E Auxiliary Building MCC 1403 A-27 S

R, H X

X X

E-13PG04 E-13PA13 E-11PG20 PG2008 2

PG20GAF1 6

Incoming Line from Load Center PG20 1403 A-27 S

R, H X

X X

E-13PG04 E-13PA13 E-11PG20 PG2008 2

PG20GAF2 6

5 kVA Process Control Inverter (PN02) 1403 A-27 S

M X

X X

E-13SC12 E-11PG20 PG20G 2

PG20GBR2 6

480VAC Non-Class 1E Distribution Panel 1403 A-27 S

R, H X

X X

E-13AB18 E-13RL07 E-11PG20 PG20G Needed for MSIV failure, fire in A-15 or A-23 2

PG20GBR217 6

MCB Misc. Power Circuits (RL023) 1403 A-27 S

R, H X

X X

E-13AB18 E-13RL07 E-11PG20 PG20G Needed for MSIV failure, fire in A-15 or A-23 2

PG20GBR219 6

Process Control Rack - Group 2 (RP047) 1403 A-27 S

M X

X X

E-13SC12 E-11PG20 PG20G 2

PG20GER5 6

Instr Bus Transformer - Alt.

Feed (XPN08D) 1403 A-27 S

H X

X X

E-13PN01A E-11PG20 PG20G 2

PG22 6

480V Non-Class 1E Load Center 1409 A-17 M

X X

X E-13PG05 NB0208 Required for alternate shutdown per OFN RP-017 XX-E-013-002-CN007 3

PG2201 6

480V Non-Class 1E Load Center PG22 Feeder Breaker 1409 A-17 M

X X

X E-13PG05 NB0208 Required for alternate shutdown per OFN RP-017 XX-E-013-002-CN007 3

WE



WE WE WE



WE WE E^^^ŽŽ

ZWW^

E^^^ŽŽ

ZWW^

0RYH WKLV OLQH WR 31 VHFWLRQ 0RYH WKLV OLQH WR 31 VHFWLRQ W&sEŽdŽ^,yyyWEW'W

WE

CCN XX-E-013-004-CN008 Page 12 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

PG2400 6

480V Non-Class 1E LC Feeder from PG1400 1403 A-27 S

R, H X

X X

E-13PG04 KD-7496 PG1400 Needed for MSIV failure, fire in A-15 or A-23 0

XPG11 5

480V Non-Class 1E LC Xfmr -

Turbine Building 4351 T-2 S

R, H X

X X

E-13PG01 KD-7496 PG1100 Needed for MSIV failure, fire in A-15 or A-23 0

XPG12 6

480V Non-Class 1E LC Xfmr -

Turbine Building 4351 T-2 S

R, H X

X X

E-13PG03 KD-7496 PG1200 Needed for MSIV failure, fire in A-15 or A-23 0

XPG19 5

480V Non-Class 1E LC Xfmr -

Auxiliary Bldg 1314 A-8 S

R, H X

X X

E-13PG02 KD-7496 PG1900 Needed for MSIV failure, fire in A-15 or A-23 0

XPG20 6

480V Non-Class 1E LC Xfmr -

Auxiliary Bldg 1403 A-27 S

R, H X

X X

E-13PA13 KD-7496 PG2000 Needed for MSIV failure, fire in A-15 or A-23 0

XPG22 6

480V Non-Class 1E LC Xfmr -

Pressurizer Heaters Group B 1409 A-17 S

X X

X E-13PG05 NB0208 Required for alternate shutdown per OFN RP-017 3

PGHIS0002 5

13.8KV Non-Class 1E Load Center Feeder PA0106 Hand Switch 3601 C-27 RL016 S

R, H X

X X

E-13PG10 PK4103 Used to trip RDMG SF001 for fire in A-27 3

PGHIS0003 6

13.8KV Non-Class 1E Load Center Feeder PA0207 Hand Switch 3601 C-27 RL016 S

R, H X

X X

E-13PG11 PK6204 Used to trip RDMG SF002 for fire in A-27 3

PK01 5

125VDC Non-Class 1E Bus 4405 TURB S

R, M, H X

X X

X E-11PK01 PK11 0

PK0101 5

125VDC Non-Class 1E Line from/to PK11 4405 TURB S

R, M, H X

X X

X E-11PK01 PK21 0

PK0102 5

125VDC Non-Class 1E from Battery Chgr PK21 4405 TURB S

M X

X X

E-11PK01 PK01 0

PK0104 5

125VDC Non-Class 1E Distr Swbd (PK41) 4405 TURB S

R, H x

X X

E-11PK01 PK01 Needed for MSIV failure, fire in A-15 or A-23 0

PK0106 5

125VDC Non-Class 1E Distr Swbd (PK61) 4405 TURB S

R, M, H X

X X

E-11PK01 PK01 0

PK0112 5

125VDC Non-Class 1E Distr Swbd (PK51) 4405 TURB S

R, M, H X

X X

E-11PK02 PK12 PK22 0

PK02 6

125VDC Non-Class 1E Bus 4405 TURB S

R, M, H X

X X

E-11PK02 PK12 PK22 0

PK0201 6

125VDC Non-Class 1E Line from/to PK12 4405 TURB S

R, M, H X

X X

E-11PK02 PK22 0

PK0202 6

125VDC Non-Class 1E from Battery Chgr PK22 4405 TURB S

R, M, H X

X X

E-11PK02 PK02 0

W<sEŽdŽdhZ^,yyyW<WEW<

WE

CCN XX-E-013-004-CN008 Page 13 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

PK0204 6

125VDC Non-Class 1E Distr Swbd (PK42) 4405 TURB S

M X

X X

E-11PK02 PK02 2

PK0206 6

125VDC Non-Class 1E Distr Swbd (PK62) 4405 TURB S

R, M, H X

X X

E-13PA14 E-11PK02 E-11PA02 KD7496 XMR01 PK6204 0

PK0211 5

125VDC Non-Class 1E Distr Swbd (PK52) 4405 TURB S

R, M, H X

X X

E-11PK02 PK02 0

PK11 5

125VDC Non-Class 1E Battery 4404 TURB S

R, M, H X

X X

E-11PK01 PK0101 PK21 0

PK12 6

125VDC Non-Class 1E Battery 4404 TURB S

R, M, H X

X X

E-11PK02 PK0201 PK22 0

PK21 5

125VDC Non-Class 1E Battery Charger 4405 TURB S

R, M, H X

X X

E-11PK01 E-11NG01 NG0102 0

PK22 6

125VDC Non-Class 1E Battery Charger 4405 TURB S

R, M, H X

X X

E-11PK02 E-11NG02 E-13PK11 NG0409 XX-E-013-001-CN011 2

PK41 5

125VDC Non-Class 1E Distribution Switchboard 4405 TURB S

R, H X

X X

E-11PK01 PK4100 Needed for MSIV failure, fire in A-15 or A-23 0

PK4100 5

125VDC Non-Class 1E Distr Swbd Incoming Fdr 4405 TURB S

R, H X

X X

E-11PK01 PK0104 Needed for MSIV failure, fire in A-15 or A-23 0

PK4103 5

PA01 Breaker Control Power (Outgoing Brkrs) 4405 TURB S

R, H X

X X

X E-11PK01 PK41 Needed for MSIV failure, fire in A-15 or A-23 0

PK4114 5

Main Turbine Stop Valves Manual Trip (AC119D) 4405 TURB S

R, H X

X X

E-11PK01 PK41 Needed for MSIV failure, fire in A-15 or A-23. XX-E-013-002-CN008 3

PK42 6

125VDC Non-Class 1E Distribution Switchboard 1403 A-27 S

M X

X X

E-11PK02 PK42 2

PK4200 6

125VDC Non-Class 1E Distr Swbd Incoming Fdr 1403 A-27 S

M X

X X

E-11PK02 PK42 2

PK4207 6

5 kVA Process Control Inverter (PN02) 1403 A-27 S

M X

X X

E-11PK02 E-13SC12 PK42 2

PK51 5

125VDC Non-Class 1E Distribution Switchboard 1403 A-27 S

R, M, H X

X X

X E-11PK01 PK0112 0

PK5100 5

125VDC Non-Class 1E Distr Swbd Incoming Fdr 1403 A-27 S

R, M, H X

X X

E-11PK01 PK0112 0

W<sEŽ^,yyyW<W<

W<

W<sEŽ^,yyyW<E'



W<sEŽŽ^,yyyW<E'

W<

W<sEŽ^,yyyW<W<

dŽWE

CCN XX-E-013-004-CN008 Page 14 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

PK5113 5

Master Supervisory Station (RP060) 1403 A-27 S

R, M, H X

X E-11PK01 PK51 RP060 is required for a fire in area C-9 and C-10 to de-energize the NB bus.

1 PK5117 5

RC & Support Sys Control Panel (RL001/RL002) 1403 A-27 S

R, M X

X X

X E-11PK01 E-13RL02 PK51 0

PK5123 5

Steam Generator Blowdown Control Pnl (BM157) 1403 A-27 S

R, M, H X

X X

E-11PK01 PK51 0

PK5126 5

Auxiliary Relay Rack (RP330) 1403 A-27 S

R, M X

X X

E-11PK01 E-13RP09 PK51 0

PK5129 5

Auxiliary Relay Rack (RP211) 1403 A-27 S

R, M X

X X

E-11PK01 E-13BM04 E-13BM06D E-13RP09 PK51 0

PK52 6

125 VDC Non-Class 1E Distribution Switchboard 1403 A-27 S

R, M, H X

X X

E-11PK02 PK0211 0

PK5200 6

125VDC Non-Class 1E Distr Swbd Incoming Fdr 1403 A-27 S

R, M, H X

X X

E-11PK02 PK0211 0

PK5213 6

Reverse Isolation Relay Rack (RP331) 1403 A-27 S

R, M, H X

X X

E-11PK02 PK52 0

PK61 5

125VDC Non-Class 1E Distribution Switchboard 1403 A-27 S

R, M, H X

X X

X E-11PK01 PK0106 0

PK6100 5

125VDC Non-Class 1E Distr Swbd Incoming Fdr 1403 A-27 S

M X

X X

E-11PK01 PK0106 0

PK6106 5

Transformer Protection Relay Panel (MA104E) 1403 A-27 S

R, M, H X

X X

E-13MR10 E-11PK01 PK61 0

PK6107 5

5KVA Process Control Inverter (PN01) 1403 A-27 S

M X

X X

X E-13SC12 PK61 0

PK6108 5

Transformer Protection Relay Panel (MA104F) 1403 A-27 S

M X

X X

E-11PK01 PK61 0

PK6115 5

Site Related Control Panel (RL013/RL014) 1403 A-27 S

R, M, H X

X E-11PK01 PK61 Panel RL013/RL014 is included for a fire in areas C-9 and C-10 to de-energize the NB bus.

1 PK6116 5

ESF Control Panel (RL017/RL018) 1403 A-27 S

M X

X X

E-11PK01 PK61 0

PK62 6

125VDC Non-Class 1E Distribution Switchboard 4405 TURB S

R, M, H X

X X

X E-11PK02 PK0206 0

W<sEŽ^,yyyW<W<

W<

W<sEŽ^,yyyW<W<

>ŽŽW<

CCN XX-E-013-004-CN008 Page 15 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

PK6200 6

125VDC Non-Class 1E Distr Swbd Incoming Fdr 4405 TURB S

R, M, H X

X X

E-11PK02 PK0206 0

PK6204 6

PA02 Breaker Control Power (Outgoing Brkrs) 4405 TURB S

R, M, H X

X X

X E-13PA14 E-11PK02 PK62 0

PK6205 6

PB04 Breaker Control Power 4405 TURB S

R, M, H X

X X

X E-11PK02 E-13AE20 E-03PB13 PK62 If power not available, locally open PB0406 0

PK6216 6

Transformer Protection Relay Panel (MA104D) 4405 TURB S

R, M, H X

X X

E-13MR10 E-11PK02 PK62 0

0PL09J 5, 6 Switchyard Remote Supervisory Cabinet S

R, M, H X

X E-1005-SY01 Panel 0PL09J is included for a fire in areas C-9 and C-10 to de-energize the NB bus.

1 PN01 5

5KVA Process Control Inverter 1403 A-27 S

M X

X X

X E-13SC12 PG19GAF1 PK6107 0

PN02 6

5KVA Process Control Inverter 1403 A-27 S

M X

X X

X E-13SC12 PG20GAF2 PK4207 2

PN07 5

120VAC Non-Class 1E Distribution Switchboard 3409 C-16 S

H X

X X

E-13PN01A E-13RL01 PN07B 0

PN0712 5

Non Class 1E 120 VAC Inverter PN09 3409 C-16 S

H X

X X

E-13PN01A PN07 Needed for MSIV failure, fire in A-15 or A-23 XX-E-013-002-CN016 3

PN0736 5

ESF Control Panel (RL017/RL018) 3409 C-16 S

H X

X X

E-13PN01A PN07 0

PN0738 5

Reactor Auxiliary Control Pnl (RL021/RL022) 3409 C-16 S

H X

X X

E-13PN01A PN07 0

PN07A 5

Voltage Regulator Panel -

22.5KVA 3409 C-16 S

H X

X X

E-13PN01A XPN07D 0

PN07B 5

Auto Transfer Switch 3409 C-16 S

H X

X X

E-13PN01A XPN07B 0

PN07C 5

Voltage Regulator Panel -

22.5KVA 3409 C-16 S

H X

X X

E-13PN01A XPN07A Added per CCN-XX-E-013-000-CN001 1

PN08 6

120VAC Non-Class 1E Distribution Switchboard 3403 C-15 S

H X

X X

E-13PN01 E-13RL01 PN08B 0

PN0806 6

Non Class 1E 120 VAC Inverter PN10 3403 C-15 S

H X

X X

E-13PN01 PN08 Needed for MSIV failure, fire in A-15 or A-23 XX-E-013-002-CN016 3

PN0833 6

ESF Control Panel (RL017/RL018) 3403 C-15 S

H X

X X

E-13PN01 PN08 0

WE<s/^,yyyWEW&

dŽW<

CCN XX-E-013-004-CN008 Page 16 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

PN0835 6

Reactor Auxiliary Control Pnl (RL021/RL022) 3403 C-15 S

H X

X X

E-13PN01 PN08 0

PN08A 6

Voltage Regulator Panel -

22.5KVA 3403 C-15 S

H X

X X

E-13PN01 XPN08D 0

PN08B 6

Auto Transfer Switch 3403 C-15 S

H X

X X

E-13PN01 XPN08C 0

PN08C 6

Voltage Regulator Panel -

22.5KVA 3403 C-15 S

H X

X X

E-13PN01 XPN08A Added per CCN-XX-E-013-000-CN001 1

PN09 5

Non Class 1E 120 VAC Inverter 3301 C-9 S

R, H X

X X

E-13RP10 PK3303 Needed for MSIV failure, fire in A-15 or A-23 XX-E-013-002-CN016 3

PN09A 5

Non Class 1E 120 VAC Distribution Switchboard 3301 C-9 S

R, H X

X X

E-13RP10 PK3303 Needed for MSIV failure, fire in A-15 or A-23 XX-E-013-002-CN016 3

PN10 6

Non Class 1E 120 VAC Inverter 3302 C-10 S

R, H X

X X

E-13RP10 PK0403 Needed for MSIV failure, fire in A-15 or A-23 XX-E-013-002-CN016 3

PN10A 6

Non Class 1E 120 VAC Distribution Switchboard 3302 C-10 S

R, H X

X X

E-13RP10 PK0403 Needed for MSIV failure, fire in A-15 or A-23 XX-E-013-002-CN016 3

XPN07A 1, 5 480/120V Instr 3-Phase Xfmr from NG01A 3409 C-16 S

H X

X X

E-13PN01A NG01ABF1 Revised per CCN-XX-E-013-000-CN001 and DCP 09803 1

XPN07D 5

480/120V Instr Xfmr from PG19G (Alt. Feed) 3409 C-16 S

H X

X X

E-13PN01A PG19GFR3 0

XPN08A 4, 6 480/120V Instr 3-Phase Xfmr from NG02A 3403 C-15 S

H X

X X

E-13PN01 NG02ADF1 Revised per CCN-XX-E-013-000-CN001 and DCP 09803 1

XPN08D 6

480/120V Instr Xfmr from PG20G (Alt. Feed) 3403 C-15 S

H X

X X

E-13PN01 PG20GER5 0

QD01 1

Emergency Lighting - Control Room 3601 C-27 S

X X

X E-03QD01 NK51A 0

QD02 1

Emergency Lighting - Control Room 3601 C-27 S

X X

X E-03QD01 NK51A 0

QD03 1

Emergency Lighting - Control Room 3601 C-27 S

X X

X E-03QD01 NK51A 0

QD04 1

Emergency Lighting - Control Room 3601 C-27 S

X X

X E-03QD01 NK51A 0

WE<s/^,yyyWEW&

dŽW<

WEE^^^ŽŽZW^,yyyWEWE

^

WEE^^^ŽŽZW^,yyyWEWE

^

CCN XX-E-013-004-CN008 Page 17 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

QD05 1

Emergency Lighting - Control Room 3601 C-27 S

X X

X E-03QD01 NK51A 0

QD06 1

Emergency Lighting - Control Room 3601 C-27 S

X X

X E-03QD01 NK51A 0

QJS0001 6

CVCS Heat Tracing Transfer Switch 1101 A-1 S

R X

X E-13QJ07 NG02A Required for OFN RP-017A to ensure alternate boration path.

XX-E-013-002-CN012 3

QJTE6244A 6

QJTS6251 Sensing RTD 1113 A-2 S

R X

X E-13QJ07 NG02A Required for OFN RP-017A to ensure alternate boration path.

XX-E-013-002-CN012 3

QJTS6251 6

CVCS Heat Tracing 1113 A-2 S

R X

X E-13QJ07 NG02A Required for OFN RP-017A to ensure alternate boration path.

XX-E-013-002-CN012 3

RL001 1, 4 Reactor Coolant & Support System MCB 3601 C-27 S

R, M, H X

X X

E-13RL01 E-13RL02 E-11NK01 E-11NK02 NK4119 NK4407 XX-E-013-001-CN013 2

RL002 1, 4 Reactor Coolant & Support System MCB 3601 C-27 S

M X

X X

E-13RL01 E-13RL02 E-11NK01 E-11NK02 NN0111 NN0212 XX-E-013-001-CN013 2

RL003 1, 4 Reactor Control Main Control Board 3601 C-27 S

R X

X X

E-13NN01 E-13SE01 NN0113 NK4116 NK5410 XX-E-013-001-CN013 2

RL005 1, 2, 3, 4 Turbine Generator &

Feedwater MCB 3601 C-27 S

R, M, H X

X X

E-13RL01 E-13RL03 E-11NK01 E-11NK02 NK4409 NK4206 XX-E-013-001-CN011 XX-E-013-001-CN013 2

RL006 1, 2, 3, 4 Turbine Generator &

Feedwater MCB 3601 C-27 S

R, M, H X

X X

E-13RL01 E-13RL03 E-11NK01 E-11NK02 NK4206 XX-E-013-001-CN011 XX-E-013-001-CN013 2

WEsŽW^,yyyWEWE



WEsŽW^,yyyWEWE



CCN XX-E-013-004-CN008 Page 18 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

RL022 1, 4 Reactor Auxiliaries Main Control Board 3601 C-27 S

H X

X X

E-13RL01 E-13RL06 E-11NK01 E-11NK02 NK4414 NK5109 PN0738 PN0835 XX-E-013-001-CN013 2

RL023 1, 4 Turbine Generator &

Feedwater MCB 3601 C-27 S

R, M, H X

X X

E-13RL01 E-13RL07 NK4411 0

RL024 1, 4 Turbine Generator &

Feedwater MCB 3601 C-27 S

R, M, H X

X X

E-13BM06A E-13RL01 E-13RL07 E-11NK01 E-11NK02 NK4411 XX-E-013-001-CN013 2

RL025 1, 4 Turbine Generator &

Feedwater MCB 3601 C-27 S

H X

X X

RL025 is included in the matrix because controls and indication are mounted on the panel. The controls and indication do not receive power from RL025.

Revised per CCN-XX-E-013-000-CN005.

1 RL026 1, 4 Turbine Generator &

Feedwater MCB 3601 C-27 S

H X

X X

RL026 is included in the matrix because controls and indication are mounted on the panel. The controls and indication do not receive power from RL026.

Added per CCN-XX-E-013 CN005.

1 RL027 1, 4 Turbine Generator &

Feedwater MCB 3601 C-27 S

H X

X X

RL027 is included in the matrix because controls and indication are mounted on the panel. The controls and indication do not receive power from RL027 0

RP043 5

Process Control Rack - Group 1

3605 C-27 S

M X

X X

E-13BB19 E-13BG10 E-13SC03 E-13SC07 E-13SC12 M-761-00140 M-761-00141 M-761-00174 PG19GCR218 PN01 2

WE

WE D

D

E^^^ŽŽ

CCN XX-E-013-004-CN008 Page 19 of 20

$33(1',;

3)66'&20321(17/,67

6RUWHGE\\6\\VWHP&RPSRQHQW,'

&$/&8/$7,2112;;(

5(9,6,2112

3DJH

Component ID S/G Description Room Fire Area Instrument Location SSD Fun Sprtd Fun Hot Stdby Cold Shdwn Normal Shdwn Alt Shdwn P&ID Schematic /

One Line Other Drawings Power Source Notes R

E V

RP047 5, 6 Process Control Rack - Group 2

3605 C-27 S

M X

X X

E-13SC01 E-13SC07 E-13SC12 M-761-00142 M-761-00143 PG20GBR219 PN02 2

RP053AA 1

BOP Instrumentation Rack 3605 C-27 S

H X

X X

E-13RP09 E-13NN01 NN0116 NN0120 0

RP053AB 1

BOP Instrumentation Rack 3605 C-27 S

H X

X X

E-13RP09 E-13NN01 NN0116 NN0120 XX-E-013-001-CN013 2

RP053AC 1

BOP Instrumentation Rack 3605 C-27 S

R, M, H X

X X

E-13RP09 E-13NN01 NN0116 NN0120 0

RP053BA 4

BOP Instrumentation Rack 3605 C-27 S

H X

X X

E-13RP09 E-13NN01 NN0416 NN0418 0

RP053BB 4

BOP Instrumentation Rack 3605 C-27 S

H X

X X

E-13RP09 E-13NN01 J-110-005592 J-110-00593 J-110-00596 NN0418 0

RP053BC 4

BOP Instrumentation Rack 3605 C-27 S

R, M, H X

X X

E-13RP09 E-13NN01 NN0416 NN0418 0

RP053DA 2

BOP Instrumentation Rack 3605 C-27 S

R, M, H X

X X

E-13RP09 NN0208 0

RP053DB 3

BOP Instrumentation Rack 3605 C-27 S

R, M, H X

X X

E-13RP09 NN0307 0

RP060 5, 6 Master Supervisory Station (Also 1PM01J) 3605 C-27 S

R, M, H X

X E-1005-SY01 PK5113 RP060 is used to open switchyard breaker 13-8 if a fire occurs in areas C-9 or C-10.

1 RP068 1, 4 Miscellaneous BOP Control Panel 3605 C-27 S

R, M, H X

X X

E-K3GD01 E-K3GD01A E-11NG21 NG01ACR142 NG02ACR136 0

RP118A 1, 3 Auxiliary Shutdown Panel 1413N A-28 S

R, M, H X

X X

E-13AB20A E-13BG36 J-110-00216 J-110-00220 J-110-00584 J-110-00587 J-110-00588 J-110-00591 NN0116 NN0307 RP118A is used during alternate shutdown to attempt to close steam dumps ABPV001 and ABPV003 and open auxiliary feedwater valves ALHV-7 and ALHV-12. Use of RP118A is prudent but not required. XX-E-013-001-CN004 2

D

D

WE

WE E^^^ŽŽ

CCN XX-E-013-004-CN008 Page 20 of 20

FORM APF 05F-001-01, REV. 06 PAGE 1 OF 3 CALCULATION VERIFICATION REPORT DOCUMENT NO. XX-E-013-004-CN008 REV. N/A DOCUMENT TITLE:

POST-FIRE SAFE SHUTDOWN (PFSSD) ANALYSIS ORIGINATOR:

Brian Fox DESIGN VERIFIED:

SAFETY CLASSIFICATION:

VERIFICATION METHOD:

PRELIMINARY SAFETY-RELATED DESIGN REVIEW FINAL SPECIAL SCOPE ALTERNATE CALCULATION REVISION NON-SAFETY RELATED TESTING INDIVIDUAL VERIFICATION SIGNATURE:

Print / Sign DATE:

_07/22/2020_____

QUALIFICATION REQUIRED: ES9280479 TEAM VERIFICATION Scope Verified:

SIGNATURE:

DATE:

TEAM LEADER SIGNATURE:

QUALIFICATION REQUIRED ES9280479 DATE:

PRINT / SIGN

  • Team leader signature certifies that adequate interfaces and overlaps have occurred.

OVERVIEW (PURPOSE AND SCOPE):

The PFSSD interface with the NSSS includes certain functions that could cause spurious operation of the pressurizer Power Operated Relief Valves (PORVs), pressurizer normal spray valves and letdown isolation valves. For PFSSD, these valves are required to be closed. Proper identification of credited PFSSD power sources and components also included in scope.

CRUCIAL AREAS:

1.

The PFSSD interface with the NSSS includes certain functions that could cause spurious operation of the pressurizer Power Operated Relief Valves (PORVs), pressurizer normal spray valves and letdown isolation valves. For PFSSD, these valves are required to be closed.

2.

PFSSD credited power source identification and configuration.

3.

PFSSD components identification and attributes.

FORM APF 05F-001-01, REV. 06 PAGE 2 OF 3 CALCULATION VERIFICATION REPORT DOCUMENT NO. XX-E-013-004-CN008 REV. N/A ALTERNATE OR INDEPENDENT ITEMS USED FOR VERIFICATION:

1.

WIP-E-15000-067-BT-1 2.

WIP-E-1F9301-005-A-1 3.

WIP-E-1F9304-002-A-1 4.

WIP-E-1F9421-007-A-1 5.

WIP-E-1F9422C-003-A-1 6.

WIP-E-1F9424E-006-A-1 7.

WIP-E-1F9910-016-A-1

FORM APF 05F-001-01, REV. 06 PAGE 3 OF 3 CALCULATION VERIFICATION REPORT DOCUMENT NO. XX-E-013-004-CN008 REV. N/A COMMENTS:

ORIGINATORS RESPONSE:

1.

Appendix 1 p22. Following sounds unresolved, why not include the evaluation determination here? E-1F9910 impact will/should address this.

"SLIM stations included in the PFSSD design to evaluate whether they can be used to close spray valves if spuriously open" This is regard to Operator interface to the normal pressurizer Small Loop Interface Modules (SLIM) BBPK0455B &

BBPK0455C. Final E-1F9910 evaluation determined fire area needed to rely on need for SLIMS to close spray valves, thereofore BBPK0455B & BBPK0455C were removed as PFSSD components.

Resolved as noted in originators comments.

2.

Appendix 3, p114 - PN031002 located in Room 3501, Fire Area C-21 (Lower Spreader) inside distibution panel PN310.

Likewise PN041001 in room 3801, Area C-22.

Agreed. Corrected.

3.

CONCLUSIONS:

Comments adequately address.

CCN provides sufficient technically justification for the determination that the 7300 Controls upgrade is not adverse to PFSSD, including closure assurance of Pressurizer Power Operated Relief Valves (PORVs), pressurizer normal spray valves and letdown isolation valves.

The population of required PFSSD components is sufficiently addressed.