ML21160A253

From kanterella
Jump to navigation Jump to search
SNM-1373 Amendment 7 Non-Sensitive Conditions
ML21160A253
Person / Time
Site: 07001374
Issue date: 06/30/2021
From: Jacob Zimmerman
Division of Fuel Management
To:
Idaho State University
OSPerez NMSS/DFM/FFL 301.415.7827
Shared Package
ML21160A250 List:
References
Download: ML21160A253 (2)


Text

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374 U.S. NUCLEAR REGULATORY COMMISSION Page 1 of 3 MATERIALS LICENSE Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10, Code of Federal Regulations, Chapter I, Parts 30, 31, 32, 33, 34, 35, 36, 39, 40, and 70, and in reliance on statements and representations heretofore made by the licensee, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, source, and special nuclear material designated below; to use such material for the purpose(s) and at the place(s) designated below; to deliver or transfer such material to persons authorized to receive it in accordance with the regulations of the applicable Part(s). This license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is subject to all applicable rules, regulations, and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any conditions specified below.

Licensee

1. Idaho State University
3. License Number: SNM-1373, Amendment 7 Lillibridge Engineering Laboratory
4. Expiration Date: August 11, 2021
2. Pocatello, Idaho 83209-0009
5. Docket No. 70-1374 OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION
6.

Byproduct Source, and/or

7. Chemical and/or Physical or
8. Maximum amount that Special Nuclear Material Form Licensee May Possess at Any One Time under this license A. Uranium enriched to less A. Solid U-Mo metal alloy clad A. See Sensitive Conditions than 20% in the isotope in aluminum plate type fuel U-235 elements B. Uranium enriched to B. Fission counter B. See Sensitive Conditions

<93 wt% in the isotope U-235 C. Uranium enriched to C. Uranium-aluminum foils C. See Sensitive Conditions

<93 wt% in the isotope U-235

9.

Authorized use: For use in accordance with the statements, representations, and conditions specified in the licensees application dated February 27, 2009, and supplements dated January 29 and February 20, 2009; February 14, 2011; August 8 and September 9, 2013; February 27, May 29, and June 5, 2015; July 7 and September 26, 2016; September 24, September 25, December 20, 2018; January 25, 2019; July 14, August 25 and November 13, 2020, March 19 and May 12, 2021.

This license contains Security-Related Information. Upon removal of the sensitive conditions on Page 3, this license is decontrolled.

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION NRC FORM 374A U.S. NUCLEAR REGULATORY COMMISSION Page 2 of 3 License Number SNM-1373 MATERIALS LICENSE SUPPLEMENTARY SHEET Docket or Reference Number 70-1374 Amendment 7

10. Authorized place of use: The Lillibridge Engineering Laboratory Building and the Particle Beam Laboratory in the Physical Science Building at Idaho State University, Pocatello, Idaho.
11.

Contamination guidelines shall be established for unrestricted release of contaminated material and equipment that are no greater than the limits identified in Branch Technical Position, Guidelines for Decontamination of Facilities and Equipment Prior to Release for Unrestricted Use or Termination of Licenses for Byproduct, Source, or Special Nuclear Material, April 1993.

FOR THE NUCLEAR REGULATORY COMMISSION Date: June 30, 2021 By: ___________________________________

Jacob I. Zimmerman, Chief Fuel Facility Licensing Branch Division of Fuel Management U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION Jacob I.

Zimmerman Digitally signed by Jacob I.

Zimmerman Date: 2021.06.30 12:19:49

-04'00'