From:
Dozier, Tami Sent:
Thursday, May 20, 2021 4:36 PM To:
AdvancedReactors-GEISDocsPEm Resource
Subject:
Environmental Assessment for Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory Attachments:
DOE 2019 EA-2087.pdf
Hearing Identifier:
AdvancedReactors_GEIS_Public Email Number:
19 Mail Envelope Properties (BY3PR09MB7585E79447CC61AE4886EB66F42A9)
Subject:
Environmental Assessment for Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory Sent Date:
5/20/2021 4:36:11 PM Received Date:
5/20/2021 4:36:17 PM From:
Dozier, Tami Created By:
Tamsen.Dozier@nrc.gov Recipients:
"AdvancedReactors-GEISDocsPEm Resource"
<AdvancedReactors-GEISDocsNPR.Resource3@nrc.gov>
Tracking Status: None Post Office:
BY3PR09MB7585.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 3
5/20/2021 4:36:17 PM DOE 2019 EA-2087.pdf 8307462 Options Priority:
Normal Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
DOE/EA-2087
Environmental Assessment for Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory Final January 2019
DOE/EA-2087 Environmental Assessment for Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory Final January 2019
iii DOE/EA-2087 Environmental Assessment for Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory Final January 2019 U.S. Department of Energy DOE Idaho Operations Office
iv CONTENTS 1
INTRODUCTION...................................................................................................................................... 1 1.1 Purpose and Need for Agency Action........................................................................................... 1 1.2 Background................................................................................................................................... 1 2
ALTERNATIVES........................................................................................................................................ 3 2.1 Alternative 1: Proposed Action -- Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory...................................................................... 3 2.1.1 Proposed Processes......................................................................................................... 3 2.1.1.1 Metallic Fuel Process....................................................................................................... 4 2.1.1.2 Ceramic Fuels Process..................................................................................................... 6 2.2 Alternative 2 - No Action.............................................................................................................. 7 3
AFFECTED ENVIRONMENT...................................................................................................................... 8 3.1 Idaho National Laboratory, Idaho................................................................................................ 8 3.1.1 General Description of INL Site and Surrounding Area................................................... 8 3.1.2 MFC Area (Area Potentially Affected by Alternative 1a and 1b)................................... 10 3.1.3 INTEC Area (Area Potentially Affected By Alternative 1b)............................................ 10 4
ENVIRONMENTAL CONSEQUENCES..................................................................................................... 11 4.1 Alternative 1 - Proposed Action: Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory.................................................................... 11 4.1.1 Construction/Modification............................................................................................ 11 4.1.2 Normal Operations Activities........................................................................................ 13 4.1.2.1 Releases to the Air......................................................................................................... 13 4.1.2.2 Waste Generation and Management............................................................................ 19 4.1.2.3 Biological Resources...................................................................................................... 20 4.1.3 Accident Consequences................................................................................................. 24 4.1.4 Impacts of Transportation............................................................................................. 26 4.1.5 Impacts of Intentional and Destructive Acts................................................................. 26 4.1.6 Sustainability................................................................................................................. 27 4.1.7 Cumulative Impacts....................................................................................................... 27 4.2 Alternative 2 - No Action............................................................................................................ 29 4.3 Summary of Environmental Impacts.......................................................................................... 30 5
PERMITS AND REGULATORY REQUIREMENTS...................................................................................... 32 6
COORDINATION AND CONSULTATION DURING EA PREPARATION...................................................... 34 7
REFERENCES......................................................................................................................................... 35 APPENDIX A - Comment Responses........................................................................................................... 37
v LIST OF FIGURES Figure 1. Figure shows the INL Site and the surrounding region with two insets showing locations of MFC and INTEC...................................................................................................................................................... 8 Figure 2. Actual and hypothetical public receptor locations for the air pathway analysis showing distance and direction from MFC and INTEC. Regulatory dose limits do not apply to the nearest boundary locations...................................................................................................................................................... 16 Figure 3. Transport route between INTEC and MFC................................................................................... 26 LIST OF TABLES Table 1. Radionuclide inventory in 2,500 kg HALEU feedstock material and unabated estimated annual potential to emit per processing facility..................................................................................................... 15 Table 2. Public air pathway potential dose estimates from normal operations (unmitigated dose)......... 17 Table 3. Collocated worker potential doses from operational radionuclide emissions (unmitigated dose).
.................................................................................................................................................................... 17 Table 4. Comparison of maximum radionuclide soil concentrations to EPA PRGs.................................... 19 Table 5. Results of Level 1 RESRAD-BIOTA analysis of proposed HALEU releases at MFC (Alternative 1a).
Terrestrial animals are the limiting organism............................................................................................. 22 Table 6. Results of Level 1 RESRAD-BIOTA analysis of proposed HALEU releases at INTEC (Alternative 1b).
Terrestrial animals are the limiting organism............................................................................................. 23 Table 7. Summary of dose impacts for the highest consequence events for Alternative 1....................... 25 Table 8 Estimated annual air pathway dose (mrem) from normal operations to the maximally exposed off-site individual from the above proposed projects, including the estimated dose from HALEU fuel production................................................................................................................................................... 29 Table 9. Summary of environmental impacts.a.......................................................................................... 30
vi ACRONYMS APAD air permitting applicability determination ATC approval to construct ATR Advanced Test Reactor CAA Clean Air Act CFR Code of Federal Regulations DOE U.S. Department of Energy DOE-ID U.S. Department of Energy - Idaho Operations Office EA environmental assessment ECAR engineering calculations and analysis report ED effective dose EIS environmental impact statement EMT electrometallurgical treatment EPA U.S. Environmental Protection Agency FR Federal Register GHG greenhouse gas GTCC Greater Than Class C HALEU High-Assay Low-Enriched Uranium HEPA High Efficiency Particulate Air HLW High-Level Waste INL Idaho National Laboratory INTEC Idaho Nuclear Technology and Engineering Center LCF latent cancer fatality LLW low-level waste MEI maximally exposed individual MOA memorandum of agreement MFC Materials and Fuels Complex MLLW mixed low-level waste NESHAPs National Emissions Standards for Plutonium-239 equivalent Hazardous Air Pollutants NEPA National Environmental Policy Act NHPA National Historic Preservation Act NRC U.S. Nuclear Regulatory Commission NRHP National Register of Historic Places NSR new source review PRGs preliminary remediation goals ppm parts per million PTC permit to construct REM roentgen equivalent man ROD record of decision RSAC Radiological Safety Analysis Computer Program SHPO State Historic Preservation Office TED total effective dose USC U.S. Code
vii HELPFUL INFORMATION FOR THE READER Scientific Notation This document uses scientific notation to express numbers that are very small or very large. A number with a negative exponent, such as 1.3 x 10-6 is a very small number. To convert this small number to the more commonly used decimal notation, move the decimal point left by the number of places equal to the exponent, in this case 6. The number thus becomes 0.0000013. For large number, those with a positive exponent, move the decimal point to the right by the number of places equal to the exponent. For instance, the number 1,300,000 becomes 1.3 x 106. This document also uses E notation for small numbers: Numbers less than 1 will have a negative exponent. For instance, a millionth of a second is: 0.000001 sec. or 1.0E-6 or 1.0^-6 or 10 x 10-6.
Units This document uses English units with conversion to metric units given below. Occasionally, metric units are used if metric is the common usage (i.e., when discussing waste volumes or when commonly used in formulas or equations).
cal/g cfm cm ft GSF in.
calories per gram cubic feet per minute centimeters foot (feet) gross square ft inch J/g km kW m
mi mi2 joule per gram kilometers kilowatt meter mile square mi mrem MT rem pCi/g T
yr millirem metric ton roentgen-equivalent-man picocurie per gram ton(s) year Conversions English to Metric Metric to English To Convert Multiply By To Obtain To Convert Multiply By To Obtain acres 4.047 x 10-1 hectares hectares 2.471 acres ft/sec 3.048 x 101 cm/sec cm/sec 3.281 x 10-2 ft/sec ft 3.048 x 10-1 m
m 3.28084 feet gallons 3.785 liters liters 2.641 x 10-1 gallons mi 1.609334 km km 6.214 x 10-1 mi square mi 2.590 square km square km 3.861 x 10-1 square mi lb 0.453592 kg kg1 2.205 lb T
9.08 x 10-1 MT MT1 1.1013 T
yards 9.144 x 10-1 m
m 1.093613 yards 1 Note: 1000 kg equals a Metric Ton (MT)
viii Understanding Small and Large Numbers Number Power Name 1,000,000,000,000,000 1,000,000,000,000 1,000,000,000 1,000,000 1,000 10 0.1 0.01 0.001 0.000 001 0.000 000 001 0.000 000 000 001 0.000 000 000 000 001
= 1015
= 1012
= 109
= 106
= 103
= 101
= 10-1
= 10-2
= 10-3
= 10-6
= 10-9
= 10-12
= 10-15 quadrillion trillion billion million thousand ten tenth hundredth thousandth millionth billionth trillionth quadrillionth
ix Understanding Dose (Millirem Doses) and Latent Cancer Fatality Relative Doses1 A dose is the amount of radiation energy absorbed by the body. The United States unit of measurement for radiation dose is the rem (Roentgen Equivalent Man). In the U.S., doses are most commonly reported in millirem (mrem). A millirem is one thousandth of a rem (1000 mrem = 1 rem). The inset diagram compares radiation doses from common radiation sources, both natural and man-made. Use this information to help understand and compare dose information described in this document.
Latent Cancer Fatality calculations The consequence of a dose to an individual is expressed as the probability that the individual would incur fatal cancer from the exposure. Based on a dose-to-risk conversion factor of 0.00041 latent cancer fatality (LCF) per person-rem), and assuming the linear no-threshold model, an exposed worker receiving a dose of 1 rem would have an estimated lifetime probability of radiation-induced fatal cancer of 0.00041 or 1 chance in 2,400.
1 From http://www.epa.gov/radiation/understand/perspective.html
x GLOSSARY Note: Terms in this Glossary are italicized in the text.
Attainment area: An area considered to have air quality as good as or better than the National Ambient Air Quality Standards as defined in the Clean Air Act (CAA). An area may be an attainment area for one pollutant and a nonattainment area for others.
Cladding: The outer layer of a nuclear fuel rod, which is located between the coolant or test environment and nuclear fuel. Cladding prevents radioactive elements from escaping the fuel into the coolant or test environment and contaminating it.
Clean Air Act (CAA): The Federal CAA is the basis for the national air pollution control effort. Basic elements of the act include National Ambient Air Quality Standards for major air pollutants, hazardous air pollutants, state attainment plans, motor vehicle emission standards, stationary source emission standards and permits, acid rain control measures, stratospheric ozone protection, and enforcement provisions.
Cultural resource: A broad term for buildings, structures, sites, districts, or objects of significance in American history, architecture, archaeology, engineering, or culture which are identifiable through field inventory, historical documentation, or oral evidence. Cultural resources may be, but are not necessarily, eligible for nomination to the National Register of Historic Places (NRHP) (see entry for historic property).
Dose consequences: The dose is the consequence of a person exposed to ionizing radiation. The increased chance of a person getting a cancer, as a result of exposure to a dose, is a risk-based consequence. If the dose is high enough, there is a chance the dose would result in a LCF. Collectively, dose, chance of getting a cancer, and risk of a LCF occurrence is the dose consequence.
Effective dose (ED): The sum of the products of the dose equivalent received by specified tissues of the body and a tissue-specific-weighting factor. This sum is a risk-equivalent value and used to estimate the health-effects risk of the exposed individual. The tissue-specific-weighting factor is the fraction of the total health risk resulting from uniform whole-body irradiation contributed by that particular tissue.
The effective dose, or ED, includes the committed ED from internal radionuclides deposition and the doses from penetrating radiation sources external to the body. The ED is expressed in units of rem. The U.S. Environmental Protection Agency (EPA) regulations in 40 Code of Federal Regulations (CFR) Part 61, Subpart H specify that estimates of radiological dose to a member of the public be reported in terms of effective dose equivalent or total ED equivalent, consistent with an older methodology described in International Commission on Radiological Protection (ICRP) Publication 26 (ICRP 1977) and ICRP Publication 30 (ICRP 1979-1988).
Fast-Spectrum Reactor: Nuclear reactor with minimal slowing down (moderation) of fission neutrons to lower energies. Such reactors use coolants other than water, which slows down neutrons, and those coolants provide some safety advantages. Fast-spectrum reactor also have advantages for managing the long-term fuel cycle and reducing long-lived constituents of high-level waste (HLW).
Fuel rod: Individual units of coated or clad nuclear fuel.
Glovebox: A controlled environment work enclosure, of rigid construction, that serves as a primary barrier from the work area. Operations are performed through sealed glove openings to protect the worker, the work environment and the product.
xi Greater-than-class C (GTCC) Low level radioactive waste (LLRW). GTCC LLRW has radionuclide concentrations exceeding the limits for Class C LLRW established by the U.S. Nuclear Regulatory Commission (NRC). These wastes are generated by activities licensed by the NRC or Agreement States and cannot be disposed of in licensed commercial LLRW disposal facilities.
HALEU: High Assay Low Enriched (U235 content ranges from >5% to <20%) Uranium. The term may be further broken out into the following:
HALEU feedstock: The nuclear material that has been processed by Fuel Conditioning Facility and is being used as feedstock for the fuel fabrication process described in this document.
HALEU fuel: The final fuel produced using the HALEU feedstock.
Hazard Category 2 nuclear facility: A nuclear facility that is allowed a significant quantity of special nuclear material as defined in DOE-STD-1027-92 (1997 Change notice).
High-level waste (HLW): High-level waste is the highly radioactive waste material resulting from the reprocessing of spent nuclear fuel, including liquid waste produced directly in reprocessing and any solid material derived from such liquid waste that contains fission products in sufficient concentrations; and other highly radioactive material that is determined, consistent with existing law, to require permanent isolation. [Adapted from:
Nuclear Waste Policy Act of 1982, as amended]
Historic property: Any prehistoric or historic district, site, building, structure, or object included in, or eligible for inclusion in, the NRHP.
Hot cell: Shielded containment chambers used to protect workers from radiation by creating a safe containment area in which workers can control and manipulate the equipment required.
Hydride-dehydride: A process used to make ceramic powder from metal uranium. The first step exposes uranium metal to flowing hydrogen gas at elevated temperature (roughly 230°C) to form uranium hydride, which breaks up the bulk metal into a powder. The second step exposes the uranium hydride powder to a vacuum at increased temperature (e.g., 400°C), which decomposes the uranium hydride into metal powder and hydrogen gas. The metal powder can then be exposed to nitrogen to form uranium nitride.
Latent cancer fatality (LCF): Based on the Linear no-threshold model, the value reported as an LCF is the risk that a death results from a dose sustained. (See Helpful Information for the Reader).
Linear no-threshold model: The hypothesized model that assumes that additional cancer risk to persons exposed to ionizing radiation is linear and proportional with respect to the absorbed dose, and becomes zero only at zero dose.
Low-level waste. Low-level radioactive waste is radioactive waste that is not high level radioactive waste, spent nuclear fuel, transuranic waste, byproduct material (as defined in section 11e.(2) of the Atomic Energy Act of 1954, as amended), or naturally occurring radioactive material. [Adapted from: Nuclear Waste Policy Act of 1982, as amended].
Mixed waste. Waste that contains both source, special nuclear, or by-product material subject to the Atomic Energy Act of 1954, as amended, and a hazardous component subject to the Resource Conservation and Recovery Act. [Adapted from: Federal Facility Compliance Act of 1992]
National Ambient Air Quality Standards: Standards established by the Environmental Protection Agency (EPA) under authority of the CAA that apply to outdoor air throughout the country. Primary standards protect human health with an adequate margin of safety, including sensitive populations (such as children, the elderly, and individuals suffering from respiratory disease). Secondary standards protect public welfare from any known or anticipated adverse effects of a pollutant.
xii National Emissions Standards for Hazardous Air Pollutants (NESHAPs): The CAA requires the EPA to regulate airborne emissions of hazardous air pollutants (including radionuclides) from a specific list of industrial sources called "source categories." Each source category that emits radionuclides in significant quantities must meet technology requirements to control hazardous air pollutants and is required to meet specific regulatory limits.
New Source Review (NSR): EPAs permitting program that protects air quality when factories, industrial boilers and power plants are newly built or modified. NSR permitting also assures that new or modified industries are as clean as possible, and advances in pollution control occur concurrently with industrial expansion.
Nitride-denitride: A process used to make uranium nitride powder from metal uranium powder. The first step exposes uranium metal powder to flowing nitrogen gas as the temperature is raised to 800°C, forming U2N3, and UN. The second step increases the temperature to over 1100°C without nitrogen flow to decompose the U2N3 powder to UN powder, which is the compound used in uranium nitride fuel.
Nonattainment NSR area: The CAA and its amendments in 1990 define a nonattainment area as a locality where air pollution levels persistently exceed National Ambient Air Quality Standards or that contribute to ambient air quality in a nearby area that fails to meet those standards. The EPA classifies nonattainment areas based on the severity of the violation and the air quality standard they exceed. EPA designations of nonattainment areas are based on violations of national air quality standards for oxides of nitrogen, carbon monoxide, lead, ozone (1-hr),
particulate matter (PM-10/PM-2.5), and sulfur oxides.
Nuclear fuel: Coated or clad nuclear material designed and fabricated to be used to power nuclear systems.
Person-rem: A person-rem is a collective radiation dose applied to populations or groups of individuals and is the product of the average dose per person (expressed in rem) times the number of people exposed or the population affected.
Receptor: Any element in the environment (typically human or ecological) which is subject to impacts, usually from exposure to hazardous conditions or substances.
Member of the public (public receptor location or hypothetical member of the public): Location where a member of the public could be when the activity is taking place. Public receptor locations correspond to the location of either an actual or a hypothetical person. These receptor locations are used because they correspond to those where the highest dose to a member of the public could occur.
Facility worker: Person working inside a facility when the activity is taking place. These workers could be protected by technical safety requirements, administrative procedures, and personal protective equipment that minimize dose in event of an accident occurring inside a facility. However, doses given in this document do not credit these protective measures.
Collocated worker: Hypothetical person working outside of the facility where the activity is occurring. These workers are less likely to be protected by technical safety requirements, administrative procedures, or personal protective equipment when an accident occurs. The doses calculated for collocated workers do not credit any protective measures that could be put in place.
Crewmember: The driver and passenger of a transportation vehicle.
Residual Fission Products: Fission products (elements/isotopes produced during irradiation) that remain in the HALEU feedstock.
Roentgen Equivalent Man (REM): The United States unit of measurement, REM, is the unit used to express effective dose (ED). REM measures the biologic effects of ionizing radiation. A millirem (mrem) is one thousandth of a rem (0.001 rem), often used to express dosages commonly encountered from medical imaging (X-rays) or natural background sources.
xiii Vadose zone: A subsurface zone of soil or rock containing fluid under pressure that is less than that of the atmosphere. Pore spaces in the vadose zone are partly filled with water and partly filled with air. The vadose zone is limited by the land surface above and by the water table below.
Thermal-Spectrum Reactor: Nuclear reactor with fission neutrons slowed down (moderated) to energies comparable to the thermal vibrational energy of atoms in the reactor structural materials and fuel. This reactor type includes light water reactors, which are used in the U.S. and elsewhere for producing electricity, heavy water reactors, and gas-cooled reactors.
Transuranic waste (TRU): Transuranic waste is radioactive waste containing more than 100 nanocuries (3700 Becquerels) of alpha-emitting transuranic isotopes per gram of waste, with half-lives greater than 20 years, except for: (1) high-level radioactive waste; (2) waste that the Secretary of Energy has determined, with the concurrence of the Administrator of the Environmental Protection Agency, does not need the degree of isolation required by the 40 CFR Part 191 disposal regulations; or (3) waste that the Nuclear Regulatory Commission has approved for disposal on a case-by-case basis in accordance with 10 CFR Part 61. [Source: WIPP Land Withdrawal Act of 1992, as amended]
xiv This Page Intentionally Blank
1 Environmental Assessment for Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory 1 INTRODUCTION 1.1 Purpose and Need for Agency Action The U.S. Department of Energy (DOE) proposes to make available about 10 Metric Tons (MT) of High-Assay Low-Enriched Uranium (HALEU2) feedstock produced through the electrometallurgical treatment (EMT) process, and other small quantities of HALEU stored at Idaho National Laboratory (INL) for research development &
demonstration in support of the commercial nuclear industry and government agencies, including use in advanced reactors. HALEU is a term applied to uranium that is enriched in the uranium-235 (U-235) isotope to a value that is 5% to 20% of the total uranium. Private sector advanced nuclear reactor designs and advanced nuclear fuel designs call for use of HALEU, but currently no commercial facility manufactures HALEU.
DOE proposes to expand the fuel fabrication capability at INL to produce HALEU fuel at INL from 10 MT of HALEU feedstock to meet near-term needs. The production requires expansion of the fuel fabrication capability, including the purchase of new equipment and use of facilities at INLs Materials and Fuels Complex (MFC) and the Idaho Nuclear Technology and Engineering Center (INTEC). DOE has made no decision on the specific use of the fuel. The fuel could be used in advanced reactor design or for the purpose of research and development.
DOE would work with other Federal agencies and commercial vendors to determine use of HALEU fuel. Use of this HALEU, including its potential use in a future nuclear reactor, will be analyzed in future National Environmental Policy Act (NEPA) documents by the appropriate agency.
The EMT process in operation at the INL converts sodium-bonded spent nuclear fuel into waste forms suitable for disposal as high-level waste and a HALEU product that is unsuitable for diversion to nuclear weapons but could be either reused in fuel or disposed of as waste. The Final Environmental Impact Statement for the Treatment and Management of Sodium-Bonded Spent Nuclear Fuel, DOE/EIS-0306, DOE 2000) discussed the EMT process, but did not make a decision on the disposition or use of the HALEU product from the EMT process.
This Environmental Assessment (EA) addresses the HALEU product as HALEU feedstock in production of HALEU fuel.
1.2 Background
The primary mission of the DOE Office of Nuclear Energy is to advance nuclear power as a resource capable of meeting the Nation's energy, environmental, and national security needs by resolving technical, cost, safety, security barriers, and proliferation concerns through research and development and demonstration. DOE has been exploring how to support deploying advanced reactor technology by the domestic (United States) nuclear industry and the industry interest in using HALEU fuel. HALEU consists of uranium enriched in the isotope U-235 between 5 and 20 percent. U-235 is an isotope of uranium that drives the nuclear reaction. Commercial reactors use fuel typically enriched between 3 and 5 percent. The higher U-235 enrichment in HALEU reactor fuel allows advanced reactors to operate longer before refueling. Public and private interest in advanced reactor technology is considerable because of the technologies potential to supply transportable, reliable, and affordable power.
2 The Glossary defines Italicized terms.
2 DOEs support of advanced reactor development may include making available about 10 MT of HALEU feedstock for use as fuel by the commercial nuclear industry and government agencies for advanced reactor research, development, and demonstration activities. Other applications using HALEU may be of interest to the commercial industry.
Most of the available HALEU at INL is a product of the EMT of sodium-bonded spent nuclear fuel (SNF) that occurs in the Fuel Conditioning Facility at the MFC at INL. DOEs Sodium Bonded Environmental Impact Statement (EIS) discusses the EMT process, DOE/EIS-0306 (DOE 2000). The EMT process involves dissolving SNF rods in molten salt and extracting uranium and transuranic elements through electrolysis, then processing in a metal casting furnace to produce low-enriched uranium ingots. The 2000 Record of Decision (ROD) for DOE/EIS-0306 did not make a decision on the disposition of the uranium ingots, instead deciding to store the ingots and deferring a decision on disposition to a separate NEPA review.
3 2 ALTERNATIVES The Council on Environmental Qualitys NEPA regulations require agencies to identify and assess reasonable alternatives (40 CFR 1500.2[e]) when proposing new activities. In line with this requirement, DOE has reviewed and analyzed two reasonable alternatives, plus a second No Action alternative, in this EA.
INL is the only location considered for the proposed action alternatives and for the no-action alternative because DOE is producing and storing the FCF HALEU feedstock at INL facilities. INL has the available facilities and process knowledge needed to carry out the proposed or no-action alternatives. Finally, the proposed action is consistent with INLs mission as the DOEs lead laboratory for nuclear energy.
DOE identified the following alternatives for analysis in this EA:
Alternative 1: Proposed Action - Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory x
Alternative 1a: Conduct activities only at MFC x
Alternative 1b: Conduct activities at MFC and INTEC Alternative 2: No action.
2.1 Alternative 1: Proposed Action -- Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory The proposed alternative calls for equipping two INL facilities at MFC or one at MFC and one at INTEC to fabricate each of two fuel types from FCF HALEU feedstock using associated fuel fabrication processes.
Specifically, INL proposes a ceramic fuel fabrication process and a metallic fuel fabrication process installed and operated within two respective INL buildings. INL has not determined which buildings would house each of the two fabrication processes. This EA evaluates the potential impacts from developing a ceramic HALEU fuel fabrication operation and a metallic HALEU fuel fabrication operation at the INL. The buildings would be distinct only by the volume of air contained and in location for possible emissions.
The EA identifies only two variants to the proposed action: 1) two buildings located at MFC, and 2) one building at MFC and one building at INTEC. There is no distinction in potential emissions from the two MFC buildings, so the only variant that bears on the environmental impacts is whether one of the buildings is at INTEC.
The 2000 ROD did not make a decision on the disposition and use of the HALEU feedstock from the EMT process. DOE now proposes to use 10 MT of HALEU feedstock produced through the EMT process, and other small quantities of HALEU feedstock stored at INL, to support early-stage demonstration by the commercial nuclear industry and government agencies. The processes need to clean the material of impurities to be useable in industry applications. Uses of the material involve research and development activities and use as nuclear fuel, including for use in advanced reactors.
2.1.1 Proposed Processes The two types of fuels considered in this document are, in general, metallic and ceramic fuels. Ceramic fuels are compounds in which a metal (uranium, in this case) is chemically combined with a non-metal, such as oxygen or nitrogen to form uranium oxide (UO2) or uranium nitride (UN), respectively. Metallic fuels are made of uranium alloyed with other elements (typically zirconium) so the fuel retains a metallic form. Most advanced reactor
4 designs call for use of one of these two types of fuel. Metallic fuels typically have been used in fast-spectrum reactors with liquid metal coolants, while ceramic fuels have been used in both fast-and thermal-spectrum reactors. Ceramic fuel fabrication is usually performed by synthesizing the ceramic compounds in powder form followed by pressing and sintering of the powders into solid pellets. Metallic fuel fabrication usually begins with melting the fuel constituents together to form an alloy, following which the alloy is immediately, or after solidification and reheating, cast or otherwise shaped to the specific form desired by the specific reactor design.
Although the specific steps and details for these fabrication processes vary for specific fuel designs, the processes can be described generically but with enough detail to allow evaluation of bounding environmental impacts. Some design specifics that bear on fabrication details include the means of thermally bonding the fuel material to the enclosing cladding; e.g., some fuel designs use a liquid metal (such as sodium, which is solid at room temperature but liquid at operating reactor temperatures) in the annular space between fuel and cladding, while other fuel designs might use helium in that gap or even eliminate the gap by pressing fuel and cladding together for a mechanical bond. Those details have little impact on the extent of environmental impact, so the fabrication processes for metallic and ceramic fuels are described generically in the following subsections.
The processes described below are based on the following assumptions:
x HALEU feedstock is obtained from Experimental Breeder Reactor-II (EBR-II) fuel processing with the intended U-235 enrichment, contaminated with about 100 parts per million (ppm) transuranic contaminants x
Residual fission products have been removed such that the feedstock can be handled without extensive shielding (i.e., without requiring shielding walls as in hot cells, although containment of low-activity contamination would require gloveboxes) x The typical batch sizes that would be processed through fuel fabrication would be roughly 30-50 Kg HALEU feedstock/batch, although this would be limited by criticality safety considerations x
The quantities of fuel assumed to be fabricated would likely require the process be operated within a double-high efficiency particulate air (HEPA) -filtered, Hazard Category 2 nuclear facility. The total target throughput of a fuel fabrication process, either ceramic or metallic, would not exceed 2500 kg/year. The process lines would be in separate facilities, the total throughput of the two combined facilities would not exceed 5000 kg/year.
2.1.1.1 Metallic Fuel Process Typical metallic fuel fabrication processes consist of the following 6 stages: 1) receipt of HALEU feedstock; 2) alloy production; 3) fuel casting or forming; 4) final mechanical processing (shearing to length, machining, forming, etc.); 5) encapsulation into cladding to form fuel rods; and 6) final inspections. Any steps involving fuel before being hermetically sealed within a cladding tube would be performed in engineered enclosures (typically gloveboxes). These stages are discussed in further detail below.
HALEU Receiving/Cleaning/Casting: Because the HALEU feedstock is coming from the FCF used fuel treatment process, an initial cleaning step may be necessary. In most cases, this could be a simple external decontamination of the as-received ingots to minimize contamination spread to the gloveboxes. In some cases, depending on the condition of the HALEU feedstock, a mechanical or chemical cleaning may be necessary to
5 remove oxide or slag layers. During the cleaning process, waste products would be generated. Following cleaning, the HALEU feedstock is ready for casting. Casting and alloying can be a one-or two-step process. In a single-step process, the HALEU feedstock and other alloying components, such as zirconium, are loaded into a crucible. The crucibles are usually coated with a non-reactive ceramic (typically yttrium oxide). The loaded crucible is placed into a furnace and heated, usually to about 1500°C and held for about 1-2 hours to melt and mix the constituents into a homogeneous alloy. The exact casting temperature used depends on alloy composition and specific process needs. The molten alloy is then poured or injected into a mold of specific shape. In a two-step process, the material is melted and poured into an interim shape, usually sized for convenient handling. The first casting step results in chemical homogeneity and allows inspection for the proper chemical composition. During the second casting step, the product is melted again and cast into the desired final fuel form. Casting operations with molten uranium alloys form an oxide slag or dross. This dross is a waste stream that requires disposal or, preferably, eventual recycle into a new casting batch. Crucibles generally can be re-used for 10-20 cycles; however, the non-reactive coating must be removed and re-applied after each casting process. In the past, single-use quartz molds have been used for solidifying the cast metal into the desired shape, and those molds could be used only a single time before being disposed as waste. Developments in recent years may allow use of re-useable fuel molds, which would reduce the amount of casting process waste.
Mechanical Processing: Industry and research institutions/organizations have communicated interest in a number of metallic fuel forms. Some fuel forms can be geometrically complex, while others may be simple right cylinders. Depending on the final fuel form, mechanical processing of fuel to final shape may be as simple as cutting or shearing a fuel slug to final length. However, more-complicated processes of machining, extrusion, drawing, or other forming methods might be needed. If the fuel is a traditional rod-type form, a simple shearing process is usually all that is required. In this case little to no additional waste is produced during this step, other than the end trimmings from the fuel slugs, which can typically be recycled into a subsequent casting batch. If machining is required, machine chips would be produced which may be recycled or disposed, depending on available recycle processes. Given the low availability and intrinsic high value in HALEU, recycling of such machining scrap material would be warranted. Additional fuel processing may include hot forming activities, such as extrusion, in which the fuel is heated to 600-900°C and forced through a die. This could be followed by another cleaning step to remove potential lubricants or surface oxides. Further mechanical processing and heat treatments, (500-850°C for less than 60 minutes) may also be needed to obtain the necessary physical and microstructural characteristics. Some additional waste would be generated from any forming activity (e.g.
leading and following blocks for extrusion).
Encapsulation: After the fuel has been formed and inspected it is ready for encapsulation into a cladding tube, which forms a fuel rod or fuel element. The cladding tubes would be brought into the facility from an off-site vendor. Cladding tubes are generally either a stainless steel, such as 316SS or 421SS, a high-alloy steel, such as a 9Cr-1Mo steel, or an alloy of zirconium. In the case of a liquid-metal bonded fuel, the cladding tubes may be pre-loaded with the bond metal (e.g. sodium) by the supplier or this operation can be completed in the fuel fabrication facility.
Fuel slugs may be loaded either vertically or horizontally into cladding tubes that are closed on one end. After the cladding tube is properly loaded, the open end is closed with an end plug that is welded into place. At this
6 point the fuel is encapsulated and can be removed from the glovebox if further processing is required. Further processing may include heat treating welds, heating the liquid metal bond material, slight deformations of the cladding tube, or wire wrapping of the fuel rods for proper spacing in the reactor. Heat treating welds, if necessary, is generally done at temperatures lower than 800°C for less than 30 minutes. If the metal bond material must be heated, the final temperature would depend on the properties of the metallic bond material, in the case of sodium, the sealed tube is heated to about 500°C for up to 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. The seal-welded fuel rods are inspected to verify closure, final dimensions, and other attributes, and then released for later assembly into fuel subassemblies.
2.1.1.2 Ceramic Fuels Process The fabrication of fuels from three representative ceramic compounds is briefly outlined here: uranium oxide, uranium nitride and uranium silicide (other compound/ceramic fuels could also be fabricated with limited changes to the production line).
HALEU Receiving and Cleaning: Because the HALEU feedstock is coming from the FCF used fuel treatment process, an initial cleaning step may be necessary. In most cases this could be a simple external decontamination of the as-received ingots to minimize contamination spread to the gloveboxes. In some cases, depending on the condition of the HALEU feedstock, a mechanical or chemical cleaning may be necessary to remove oxide or slag layers. During the cleaning process, waste products would be generated.
Powder Production: Powder production could occur by three processes:
- 1. Uranium oxide would be produced by the reaction of uranium metal directly with oxygen through a process known as roasting. This involves a controlled atmosphere furnace with an agitation system to separate the oxidized material as it reacts. The oxidized powder would be a mix of oxidation states and would undergo another furnace run in a reducing atmosphere to transform the material into UO2. The resultant material would undergo a granulation step to form it into powder that would be compatible with the rotary press that produces the pellets.
- 2. Uranium silicide is made by first alloying silicon with the FCF metallic HALEU feedstock. Preferential loss of silicon during initial melting is minimized by using an arc-melting furnace to produce the uranium silicon alloy. After more homogenization melts, the ingot is mechanically broken up and ball-milled to reduce the material particle size to the proper powder size. The milling media is periodically replaced and disposed as waste.
- 3. Uranium nitride is produced through a hydride-dehydride/nitride-denitride process (i.e., forming uranium hydride, then decomposing the hydride to form powder that is then nitrided to form uranium nitride).This process is done by heating the bulk uranium in a hydrogen atmosphere (the optimal temperature is 225°C) until the uranium has reacted with hydrogen followed by introduction of vacuum (still at temperature) until the material has turned into a fine powder. The process is repeated with nitrogen (the denitriding step reduces the material from U2N3 to the required UN).
Pellet Production: Following powder manufacture, fuel pellets are formed using an industry standard pelletizing process. Each powder requires optimizing parameters, with variables such as binder, die lubrication and pressing parameters evaluated. The residual contaminants expected to be present in the HALEU feedstock requires that the powder and pelletizing operations be performed within containment gloveboxes. Depending on the
7 characteristics and chemical reactivity of the powder, the pelletizing process might need to be contained in inert atmosphere gloveboxes (for example, uranium silicide powder is potentially pyrophoric and must be handled away from atmospheric air).
The prepared fuel powder is fed into a rotary die where the material is pressed at room temperature to form green pellets (i.e., pellets that have been pressed from powder but not yet sintered into non-friable pellets).
Green pellets are later heated in a sintering furnace (at temperatures ranging from 1450 to 2000°C). The atmosphere of the furnace needs to vary depending on the material: silicide fuel requires an inert atmosphere while oxide and nitride need a reducing atmosphere, such as dry argon with a small amount of hydrogen.
Following sintering, pellets are ground to final diameter using centerless grinders (the desired length and end chamfer are imparted during pelletizing). Following quality inspection, the pellets are ready to be encapsulated into fuel rods.
Encapsulation: Fuel pellets approved by inspection are laid out in channeled trays in single columns. After the proper number of pellets are arranged into columns, the pellet columns are pushed horizontally into a horizontal cladding tube that is sealed on one end. The cladding tubes would be brought into the facility from an off-site vendor. Cladding tubes are generally either a stainless steel, such as 316SS or 421SS, a high-alloy steel, such as a 9Cr-1Mo steel, or an alloy of zirconium. After the cladding tube is properly loaded, the open end is closed with an end plug that is welded into place. The seal-welded fuel rods are inspected to verify closure, final dimensions, and other attributes, and then released for later assembly into fuel subassemblies.
2.2 Alternative 2 - No Action Under the No Action Alternative, DOE would continue to electrometallurgically treat the EBR-II spent nuclear fuel (about 25 metric tons) and miscellaneous small lots of sodium bonded spent nuclear fuel, as decided in the ROD for the Treatment and Management of Sodium Bonded Spent Nuclear Fuel (FR Vol. 65, No. 182, September 19, 2000 pp. 56565-56570) and addressed in DOEs Sodium-Bonded EIS, DOE/EIS-306 (DOE 2000). DOE would continue to treat the fuel at MFC, blend with depleted uranium, if needed, to reduce the enrichment levels, and cast into ingots to store until deciding on appropriate disposition made through a separate NEPA review.
8 3 AFFECTED ENVIRONMENT 3.1 Idaho National Laboratory, Idaho 3.1.1 General Description of INL Site and Surrounding Area The INL Site consists of several complexes, each taking up less than 2 square miles, located across an 890 square miles expanse of otherwise undeveloped, cool desert terrain. DOE controls the INL Site land, which is located in southeastern Idaho and includes portions of five Idaho counties: Butte, Bingham, Bonneville, Clark, and Jefferson. Population centers in the region include the cities (>10,000 people) of Idaho Falls, Pocatello, Rexburg, and Blackfoot, located further than 30 miles to the east and south; several smaller cities/communities (<10,000 people), including Arco, Howe, Mud Lake, Fort Hall Indian Reservation, and Atomic City, located around the site less than 30 miles away. Craters of the Moon National Monument is less than 20 miles to the west of the western INL boundary; Yellowstone and Grand Teton National Parks and the city of Jackson, Wyoming are located more than 70 miles northeast of the closest INL boundaries. (see Figure 1)
Populations potentially affected by INL Site activities include INL Site employees, ranchers who graze livestock in areas on or near the INL Site, hunters on or near the INL Site, residential populations in neighboring communities, travelers along U.S. Highway 20/26, and visitors at the Experimental Breeder Reactor I National Historic Landmark. There are no permanent residents on the INL Site.
The five Idaho counties that are part of the INL Site are in an attainment area or are unclassified for National Ambient Air Quality Standards status under the Clean Air Act (CAA). The nearest new source review (NSR) nonattainment area is located about 50 miles south of INL in Power and Bannock counties. INL is classified under the NSR minor source permit regulations as a Class II areaan area with reasonable or moderately good air quality.
Surface waters on the INL Site include the Big Lost River and Birch Creek. Both streams carry water on an irregular basis, with the majority of the flow diverted for irrigation before entering INL. The Snake River Plain Aquifer, which lies between 220 ft (at the north end of the Site) to 610 ft (at the south end of the Site) below the surface of the Site. The geology above the Snake River Plain Aquiferthe vadose zoneis generally comprised of basalt (95%), with a layer of soil or sediment on top of the basalt, and thin layers of Figure 1. Figure shows the INL Site and the surrounding region with two insets showing locations of MFC and INTEC.
9 sediments (1 to 20 ft intervals) between basalt flows. The Snake River Plain Aquifer has similar geology as the overlying vadose zone and is generally 250 to 900 ft thick.
Predominant natural vegetation of the INL Site consists of a shrub overstory with a perennial grass and forb understory. The most common shrub is Wyoming big sagebrush, although basin big sagebrush may dominate or co-dominate in areas with deep or sandy soils. Other common shrubs include green rabbitbrush, winterfat, spiny hopsage, gray horsebrush, gray rabbitbrush, and prickly phlox. The grass and forb understory consists of native grasses, thick-spiked wheatgrass, Indian ricegrass, bottlebrush squirreltail, needle-and-thread grass, Nevada bluegrass, and bluebunch wheatgrass and native forbs (i.e., tapertip hawksbeard, Hoods phlox, hoary false yarrow, paintbrush, globe-mallow, buckwheat, lupine, milkvetches, and mustards). Steep slopes and rises associated with buttes, bluffs and foothills may be dominated or co-dominated by Utah juniper. Part of the INL Site has been designated as the Sagebrush Steppe Ecosystem Reserve, which is managed to allow research opportunities and preserve sagebrush steppe habitat. The INL site is also designated as a National Environmental Research Park.
A total of 219 vertebrate species have been recorded as occurring at the INL Site. These wildlife species include amphibians, reptiles, rodents, carnivores, bats, big game and birds. Several of these species are sagebrush-obligate species, meaning that they rely upon sagebrush for survival. These species include sage sparrow, Brewers sparrow, sage thrasher, northern sagebrush lizard, greater sage-grouse, and pygmy rabbit.
The INL Site also contains important breeding and nesting habitat for many species of raptors and songbirds.
Most avian species occupying the INL Site use both sagebrush and grassland habitats from a few days for feeding and resting during migration to several months for breeding and raising young. Many bird species use specific habitats for foraging and reproduction. Species that primarily use sagebrush include greater sage-grouse, sage sparrow, Brewers sparrow, sage thrasher, and loggerhead shrike. Species that occur mainly in grassland habitats include horned lark, western meadowlark, vesper sparrow, and grasshopper sparrow. Other common bird species at the INL Site include the following: rock wren, common nighthawk, red-tailed hawk, rough-legged hawk, prairie falcon, ferruginous hawk, golden eagle, and common raven. Although most raptors range widely across the INL Site for foraging, nesting habitat and structures are a limiting factor in population abundance and species diversity.
No resident species on the INL Site are listed as endangered or threatened under the Endangered Species Act.
North American wolverine (Gulo gulo luscus) has not been documented at the INL Site, but may pass through it.
Yellow-billed cuckoo (Coccyzus americanus) is known to breed in river valleys in southern Idaho (Federal Register, Vol. 79 No. 192, October 3, 2014), but has only been observed once near the INL Site at Atomic City.
The INL Site has no designated critical habitat. Several species identified as Birds of Conservation Concern under the Migratory Bird Treaty Act or as Species of Greatest Conservation Need under state of Idaho regulations do occur on the INL Site, including bald eagle, Brewers sparrow, burrowing owl, common nighthawk, golden eagle, grasshopper sparrow, greater sage-grouse, long-billed curlew, ferruginous hawk, Franklins gull, loggerhead shrike, peregrine falcon, sage thrasher, sagebrush sparrow, short-eared owl, pygmy rabbit, hoary bat, little brown myotis, Townsends big-eared bat, silver-haired bat, and western small-footed myotis. In 2010, a status review of little brown myotis was prepared and determined that emergency listing under the Endangered Species Act was warranted. The U.S. Fish and Wildlife Service has not made a final determination on listing of little brown myotis.
10 Several wildlife species that were delisted but continue to be monitored are present on the INL Site. Bald eagle (Haliaeetus leucocephalus) was delisted in 2007, but is still protected under the Bald and Golden Eagle Protection Act. The Bald Eagle often winters in the Little Lost River Valley just north of the INL Site and some eagles winter on the INL Site. American peregrine falcon (Falco peregrinus), delisted in 2009, has been observed infrequently on the northern part of the INL Site.
The cultural landscape of the INL represents nearly 13,500 years of human occupation and land use. Historic properties (those properties either listed or eligible for listing on the National Register of Historic Places [NRHP])
present within INL boundaries include both archaeological sites, and resources associated with the built environment. Archaeological sites encompass Native American habitation, and late 19th and early 20th century Euro-American sites associated with mining, canal and railroad construction, emigration and homesteading, agriculture, and ranching. Resources within the built environment consist of modern roads, railroad tracks, irrigation canals, and transmission and telephone lines, along with buildings and landscape features associated with the Arco Naval Proving Ground (NPG) and nuclear energy research at INL between 1949 and 1970, including the MFC and the INTEC. Additionally, the INL site contains numerous areas and natural resources of traditional cultural importance to the Shoshone-Bannock Tribes.
Two NRHP listed historic properties occur on the INL:
x Aviator's Cave is listed under Criterion D for archaeological potential, and cultural significance to the Shoshone-Bannock Tribes; and x
Experimental Breeder Reactor one (EBR-I) is listed under Criterion A for its association with events that have made a significant contribution to the broad patterns of American history, and Criterion C for distinctive characteristics of a method of construction.
3.1.2 MFC Area (Area Potentially Affected by Alternative 1a and 1b)
MFC, which is located about 38 miles west of Idaho Falls in Bingham County in the southeastern corner of INL.
MFC is about 100 acres (inside the MFC fence) and about 2.7 mi (4.3 km) from the southern INL Site boundary.
MFC is engaged in advanced nuclear power research and development, spent fuel and waste treatment technologies, national security programs, and projects to support space exploration. Formerly the Argonne National Laboratory-West (ANL-W), the MFC was established in 1949. For the next half-century, its primary mission was to take nuclear reactor power stations through the steps from design to demonstration.
3.1.3 INTEC Area (Area Potentially Affected By Alternative 1b)
INTEC is located in the southcentral portion of the INL Site in Butte County, between INLs Advanced Test Reactor (ATR) Complex and Critical Infrastructure Test Range Complex areas, and just south of the Big Lost River.
INTEC is about 210 acres (inside the INTEC fence) and about 13.7 km (8.5 mi) from the southern INL Site boundary.
INTEC was a one-of-a-kind facility built in the early 1950s for reprocessing government-owned nuclear fuels from research and defense (primarily naval) reactors. Through April 1992, INTEC recovered uranium from the spent nuclear fuels for reuse. The current missions at INTEC include safe and secure storage and handling of spent nuclear fuel, special nuclear material, and waste by-products; waste treatment; and dismantle and demolition of facilities that are no longer needed.
11 4 ENVIRONMENTAL CONSEQUENCES The following sections evaluate direct, indirect, and cumulative environmental impacts that are likely to occur from the alternatives described in Section 2. Section 4.1 discusses the environmental impacts associated with Alternative 1. Section 4.2 discusses the environmental impacts associated with no action. Each section discusses cause and effect relationships, including cumulative impacts, of the proposed actions on INLs natural, biological, and cultural resources; mitigative measures needed to lessen impacts; and those permits and regulations required to protect the resources.
During the EA scoping meeting, resource personnel identified that the proposed action could potentially affect air, biological and cultural resources and waste generation and management. This document evaluates impacts from construction/modification impacts to air, cultural and waste management (Section 4.1.1); normal operations to air, waste generation and management, and biological resources (Section 4.1.2); Accidents (Section 4.1.3); Transportation (Section 4.1.4); Destructive Acts (Section 4.1.5), and Cumulative Impacts (Section 4.1.6).
DOE uses engineered and administrative controls to make work safe and to reduce the potential for environmental consequences of its operations.
4.1 Alternative 1 - Proposed Action: Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory 4.1.1 Construction/Modification The proposed action would result in facility modifications that involve construction activities that include modifying facilities to support fuel-fabricating processes to separate the proposed processes (e.g., physical changes to buildings, ventilation separation, and so forth). These activities could affect air and cultural resources and waste generation and management.
Air -
The proposed action would likely result in fugitive dust and emissions. Before commencing any construction or modification, facility environmental personnel would complete an air permitting applicability determination (APAD). If an approval to construct (ATC) from Environmental Protection Agency (EPA) or a permit to construct (PTC) from the Idaho Department of Environmental Quality (DEQ) is required, an ATC or PTC would be obtained before commencing construction or modification. Construction and modification activities are not expected to release radiological contamination. However, activities could disturb materials containing asbestos; therefore, properly trained personnel would perform work on asbestos containing building materials.
Cultural -
The proposed action would not disturb areas outside facility areas, but could impact historic properties at MFC or INTEC. DOE has chosen to defer Section 106, per 36 CFR 800.14(b)(1)(ii), until after a NEPA decision has been made since the specific buildings to be used for the project have not been determined. As such, the final Area of Potential Effect (APE), impacts, and final agreement regarding mitigation of historic properties have not been identified.
12 DOE has not determined which buildings at either MFC or INTEC would be used under the proposed action, but potential impacts include:
x installation of a 15-meter-tall emissions stacks x
installation of an exterior staircase x
interior modifications to accommodate production equipment, such as reconfiguration or installation of walls and ductwork x
replacement or installation of HVAC systems and filter housings x
updating of life safety systems and radiation monitors x
interior or exterior painting No building demolition or major additions are anticipated for the proposed alternative.
Potential buildings may include Category 2 or 3 historic properties. Property categories are defined in the INL Cultural Resource Management Plan (CRMP; February 2016, Rev. 06) as Signature, Category 1, Category 2 or Category 3 Properties, from most significant to least. Category 2 Properties are defined as Contributing INL properties directly associated with signature or key individual properties (control buildings, hot shops, and artifacts such as the TAN shielded locomotive). Category 3 Properties are defined as Contributing INL properties not directly associated with signature or key individual properties (e.g. cafeterias and warehouses).
The anticipated Section 106 process for the HALEU project must consider potential effects to these property types.
Typical mitigations of Category 2 and Category 3 historic properties include:
x Category 2 Historic Properties: Requires exterior and interior (when possible) documentation with large format photography meeting NPS HABS/HAER standards. The photographs will be preserved in the INL Cultural Resource Management Office (CRMO) along with architectural and engineering drawings that depict elevations, sections, details, and historic features; and with available historic photographs of construction, manufacture, and other activities or experiments, when possible. This documentation will be made available to scholars, researchers, and other interested parties (as appropriate in keeping with security standards). Additionally, these photographs and other documents will be available for future HABS/HAER studies.
x Category 3 Historic Properties: Requires photographic documentation meeting Idaho SHPO mitigation photo standards and completion of an Idaho Historic Sites Inventory form. This documentation will be preserved by the INL CRMO and made available to scholars, researchers, and other interested parties.
Photography may be included in future HABS/HAER studies as appropriate to illustrate narrative.
DOE negotiated a process for deferment of Section 106 under the proposed action for Alternative 1, with the Idaho State Historic Preservation Office (SHPO). The following process was proposed by DOE and concurred on by the Idaho SHPO in an October 18, 2018 letter:
- 1) The Idaho SHPO will be allowed the opportunity to review the language in the EA regarding deferment of Section 106 once the document has been made available for public comment, as per 36 CFR 800.8(c)(2)(i);
- 2) DOE will prepare a Memorandum of Agreement (MOA) outlining how the Section 106 process will be completed, once determinations are made regarding the specific buildings involved in the undertaking.
13
- 3) The MOA will be signed prior to making the NEPA decision. The NEPA decision will include stipulations for completing the Section 106 process.
If the undertaking involves a historic property, potential impacts to that property will be assessed, as outlined in the stipulations in the MOA:
x The Section 106 process will begin once the Project scope and description has been completed.
x Completion of the Section 106 process will include:
Identification of historic properties within the APE; Evaluation of potential effects - immediate and cumulative direct and indirect - to historic properties from project activities.
- 4) Adverse Effects will be mitigated as identified in the INL Cultural Resource Management Plan, which may require consultation and concurrence between DOE-ID, the Shoshone-Bannock Tribes and the Idaho SHPO.
Waste Management -
Modifying buildings at MFC and INTEC for the new fuel fabrication processes would generate waste. The modifications for fuel fabrication would generate non-radioactive electronic waste, scrap metal, and other construction-related debris. Construction debris, electronic waste, and scrap metal would be recycled to the extent possible. Activities could require disposal of construction debris, concrete, coolants, and hydraulic/lubricating fluids. These wastes could be recycled or disposed at on-site facilities or sent off-site. These modifications could also generate radioactive waste. Constructing and modifying activities would likely generate mixed low-level waste (MLLW) (waste that is both radioactive and hazardous).
Based upon estimates supplied by MFC Engineering the amount of waste generated to refurbish a radiological facility would be about 218 m3. During FY 2018, INL sent 934-m3 low-level waste (LLW) to off-site facilities for disposal. INL would accumulate and store any waste generated per Federal and state regulations, and if required, treat and disposed at an off-site permitted/licensed facility.
4.1.2 Normal Operations Activities Normal activities involved in the processing of HALEU include those described in Section 2.1.3 (e.g., cleaning, casting/alloying, cutting/shearing, machining/extruding/drawing, welding, dissolving, calcining/drying, pelleting, sintering, and grinding).
Processes would use engineered and administrative controls to enhance safety and minimize the potential for environmental consequences. The only anticipated releases would be to the atmosphere.
4.1.2.1 Releases to the Air Toxic EmissionsNonradiological emissions would be minimal during operational stages. Welding emissions during cladding operations, as well as hazardous and toxic air emissions from processing, would from experience be expected to be below State of Idahos toxic regulations. Ceramic fuels processing may involve using hydrochloric acid, hydrogen peroxide, and nitric acid. An acid scrubber system would be required to keep Helpful Information for the Reader When reviewing the impact of toxic and radiological releases to the air from normal operation, transportation, and accidents it may be useful to refer back to the section on Helpful Information (page vi) for discussion on Scientific Notation, English/Metric Units, Understanding Small and Large Numbers, and Understanding Dose and Latent Cancer Fatalities.
14 emissions below State of Idaho toxic limits. During encapsulation phase, some minor welding is performed to seal cladding tubes. These welding emissions are minor (an estimated 5.5 grams of chromium and 4.2 grams of nickel fume may be generated per batch based on the amount of welding rod used). Cleaning for external contamination may use small amounts of nitric acid (about 2 liters per batch). The APAD will quantify these emissions.
Radiological Impacts of Atmospheric ReleasesDuring normal operations, radioactive particulate matter and gaseous emissions are possible. Based on the proposed processing operations, the potential for release of particulate contamination, and gaseous/vapor-phase radionuclides is greatest when the fuel is heated during the casting phase. During processing operations, the amount of radioactive material released during heating operations is assumed the same for each alternative. Operations planned for Alternatives 1a and 1b involve heating with equivalent cleanup efficiencies, i.e., two stages of HEPA filtration each with at least 99.97% removal of airborne material with a particulate size of 0.3 m or greater. For the APAD evaluation HEPA filtration is not credited for gaseous/vapor phase radionuclides.
Each of the two facilities could process a maximum 2,500 kg of HALEU feedstock annually. The average radionuclide composition in the HALEU feedstock (TEV-3537) was used to determine the activity inventory in 2,500 kg as shown in Table 1.
Potential emissions were conservatively estimated using the maximum amount of feedstock material to be processed annually and appropriate emission factors based on the physical state of the material. Because the material could undergo heating, an alternative to the method in 40 CFR 61 Appendix D, approved for use at INL by EPA Region 10 (see letter from Donald Dossett [EPA Region 10] to Tim Safford (U.S. Department of Energy -
Idaho Operations Office [DOE-ID] Oct 19, 2017 [CCN 241475]) was used to determine the emission factors for radioactive solid materials with high melting and boiling points. These emission factors are:
x 1 for radioactive solid materials heated to temperatures greater than or equal to 90% of the boiling or subliming point; x
1E-03 for radioactive solid materials heated to temperatures greater than or equal to their melting point but less than 90% of their boiling or subliming point; and x
1E-06 for radioactive solid materials heated to temperatures above ambient temperature but less than their melting point.
Table 1 shows the emission factors and potential radionuclide emissions for 2,500 kg of HALEU feedstock material assuming the material is heated to a temperature of 2000 C, which equals or exceeds the maximum predicted temperature of both the metallic and ceramic processes. In this case, the emission potential is the product of the inventory and the emission factor and represents the amount that could potentially be released from the facility annually. It was assumed that the most likely manner for emissions to exit the processing facilities during normal operations would be from a stack similar to the stacks at the Fuel Manufacturing Facility or Irradiated Materials Characterization Laboratory at MFC. These stacks are about 15 m high with an exit diameter of 0.6 m.
15 Table 1. Radionuclide inventory in 2,500 kg HALEU feedstock material and unabated estimated annual potential to emit per processing facility.
Radionuclidea Inventory in 2,500 kgb (Ci)
Emission Factor (at 2000 C)
Emission Potential per Facilityb (Ci/yr)
Mn-54 5.89E-02 1
5.89E-02 Co-60 7.86E-02 0.001 7.86E-05 Sr-90 5.40E+00 1
5.40E+00 Tc-99 6.41E-03 0.000001 6.41E-09 Sb-125 2.67E-01 1
2.67E-01 Cs-134 8.06E-02 1
8.06E-02 Cs-135 7.68E-03 1
7.68E-03 Cs-137 1.74E+00 1
1.74E+00 Ce-144 5.34E-01 0.001 5.34E-04 Eu-154 1.49E-01 1
1.49E-01 Eu-155 2.67E-01 1
2.67E-01 Np-237 3.02E-02 0.001 3.02E-05 Pu-239 1.30E+01 0.001 1.30E-02 Pu-240 1.27E+00 0.001 1.27E-03 Am-241 5.25E-01 1
5.25E-01 U-234 2.48E+01 0.001 2.48E-02 U-235 1.04E+00 0.001 1.04E-03 U-236 8.38E-01 0.001 8.38E-04 U-238 6.68E-01 0.001 6.68E-04 U-232 2.77E-01 0.001 2.77E-04 U-233 7.67E-03 0.001 7.67E-06 U-237 7.67E-03 0.001 4.49E-05
- a.
Includes nuclides whose concentrations were measured by analysis or determined by modeling; other nuclides, including radioactive decay products, may be present at very low concentrations but does not change the conclusions of the analyses presented in the EA.
- b.
Alternative 1a assumes two processing facilities at MFC that would each process 2,500 kg annually for a total of 5,000 kg processed annually at MFC. Alternative 1b assumes one processing facility at MFC and one processing facility at INTEC that would each process 2,500 kg annually. Thus the emission rates are per facility.
Public Receptor The CAP88-PC computer code was used to model atmospheric transport of the emissions and calculate the potential effective dose (ED) at the following public receptor locations for Alternatives 1a and 1b (see Figure 2)
(ECAR-4321).
- 1. INL Site boundary nearest MFC: Located 5 km from MFC and 400 m north of the INL East entrance on Highway 20, which is accessible to the public, but there are no permanent residents (hypothetical receptor). Regulatory dose limits do not apply to this location. Doses are presented only for reference.
- 2. INL Site boundary nearest INTEC: Located about 14 km directly south of the INTEC entrance and 10 km west of Atomic City. The distance to INLs Site boundary northwest of INTEC is about the same distance, but the dose at the south receptor is higher. This location is accessible to the public, but there are no permanent residents. Regulatory dose limits do not apply to this location. Doses are presented only for reference.
- 3. Permanent resident nearest MFC: This is a farmhouse located 9 km from MFC and 3.1 km south of Highway 20, 3 km from INLs East entrance. Regulatory dose limits apply at this location.
16
- 4. Atomic City: This town of population 29 (2010 census) is located about 2 km east of INLs South entrance on Highway 26. The residence nearest INTEC is located in Atomic City. Atomic City is about 21 km SSW of MFC and 17 km SE of INTEC. Regulatory dose limits apply at this location.
- 5. Frenchmans Cabin: This location is about 2 km south of the southern INL boundary near Big Southern Butte. This location is used to show INL Site compliance with 40 CFR 61, Subpart H - National Emissions Standards for Hazardous Air Pollutants (NESHAPs) Other Than Radon From Department of Energy Facilities, and is the location of the maximally exposed individual (MEI). The site may be inhabited during portions of the year. Regulatory dose limits do apply to this location because of the potential for occupation during a portion of the year.
Figure 2. Actual and hypothetical public receptor locations for the air pathway analysis showing distance and direction from MFC and INTEC. Regulatory dose limits do not apply to the nearest boundary locations.
Table 2 shows the calculated potential EDs for public receptor locations from normal operations (ECAR-4321).
For each alternative, the doses are well below the 10 mrem/year federal standard set by 40 CFR 61, Subpart H for public exposures. Cumulative doses from all INL sources would also be well below the 10 mrem/year dose standard at the INL MEI location (see Section 4.1.7).
17 Table 2. Public air pathway potential dose estimates from normal operations (unmitigated dose).
Potential Receptor Location Alternative 1a Total ED (mrem/year)
Alternative 1b Total ED (mrem/year)
INL Site Boundary Nearest MFC (hypothetical receptor)a 5.4d 3.1d INL Site Boundary Nearest INTEC (hypothetical receptor)a NAb 2.2 Residence Nearest MFC 2.4e 1.5 Atomic Cityc 1.9 1.5 Frenchman's Cabin (INL Site NESHAP MEI) 0.74 1.6e
- a.
INL Site boundary locations between the two boundary locations were not evaluated, but the dose at other boundary locations is likely bounded by these values.
- b.
Location not applicable to Alternative 1a since there are no emissions from INTEC.
- c.
The Residence nearest INTEC is located at Atomic City.
- d.
Highest potential dose at a publicly accessible location, but no permanent resident (hypothetical receptor). Regulatory dose limits do not apply to these locations. Doses are presented only for reference.
- e.
Highest potential dose at a location with a residence, school, business or office.
Collocated Worker Receptor Collocated worker potential doses were calculated at 100 m from the source stack in the direction of maximum dose using the same atmospheric transport and dose model used for public dose calculations. However, worker dose estimates do not include the ingestion pathway because workers do not consume contaminated food products, and the inhalation and external doses were scaled to account for the reduced time workers would be onsite.
Table 3 shows the calculated EDs for collocated workers from normal operations (ECAR-4321). For Alternative 1b, doses are presented for both MFC and INTEC with the difference attributed to the different meteorological conditions. For each alternative, the doses are well below the 5,000 mrem/yr federal occupational dose limit for general employees (10 CFR 835.202).
Table 3. Collocated worker potential doses from operational radionuclide emissions (unmitigated dose).
Alternative Facility Feedstock Material Processed Annually Total EDa (mrem/yr) 1a MFC 5,000 kg 48 1b MFC INTEC 2,500 kg 2,500 kg 24 33
- a.
Dose at 100 m from stack in direction of maximum dose.
Groundwater Exposure Pathway Consequences of potential groundwater contamination resulting from air emissions depositing on soil and migrating to the aquifer were evaluated with the computer model GWSCREEN (Version 2.5a). GWSCREEN parameter input values and assumptions were generally consistent with those used to perform Track 2 CERCLA assessments for low probability hazard sites at INL (DOE-ID 1994). Thus, the groundwater pathway modeling is effectively a screening-level assessment and the impacts should be viewed as bounding.
In the model, radionuclides deposited on surficial soils are transported downward through the unsaturated zone and into the aquifer by natural precipitation and infiltration. In the unsaturated zone, radionuclides can undergo advection, longitudinal dispersion, sorption and radioactive chain decay and ingrowth. Once in the aquifer, similar transport and decay processes occur as contaminants move with the regional groundwater flow. The
18 GWSCREEN model provides radionuclide concentrations in the aquifer and effective dose from groundwater ingestion.
All radionuclides were modeled except those with half-lives less than 1 year (Mn-54, Ce-144 and U-237) because they would decay to insignificant levels before reaching the aquifer. Significant long-lived progeny are included explicitly in the model and assumed to be generated as the parent radionuclides decay. Short-lived radionuclide progeny were not modeled explicitly but are assumed to be in secular equilibrium with the parent. Where progeny are not explicitly modeled, the effective dose coefficients include the contribution from progeny.
Impacts to the aquifer are bounded by Alternative 1a where all 10,000 kg of HALEU feedstock would be processed at MFC. The calculations assume all emissions for the 2-year operating period are deposited uniformly over a 400 m x 400 m area surrounding the facility. This area is based on air-dispersion modeling results that indicate maximum deposition occurs approximately 100 m to 200 m from the emission stack. Assuming all radionuclides deposit within 200 m of the stack is a conservative assumption as the emissions would be spread over a much larger area. The groundwater receptor well is assumed located at the downgradient edge of the 400 m x 400 m source zone, the location of maximum concentration.
The peak total effective dose (TED) from groundwater ingestions for Alternative 1a is 0.059 mrem/yr and occurs approximately 1,600 years after operations. The impact for Alternative 1b would be approximately one half the effective dose of Alternative 1a (0.03 mrem/yr) and would occur at both INTEC and MFC. There would be slight differences in the results based on differences between the two sites in terms of cumulative interbed thickness in the unsaturated zone and groundwater velocity in the aquifer, but the dose at each facility would not be greater than the 0.059 mrem/yr dose for Alternative 1a. Thus, the impact from either alternative would be less than 0.1% of the regulatory dose limit of 100 mrem/yr (DOE O 458.1).
Surface Soil Exposure Pathway Estimated potential doses to public receptors (Table 2) and collocated workers (Table 3) from atmospheric emissions include impacts from air immersion, inhalation of contaminated air, ingestion of contaminated food products and direct radiation from ground deposition. Additional impacts from incidental ingestion of contaminated soil and inhalation of fugitive dust (particulate matter) were assessed by calculating soil concentrations due to build-up of particulate deposition, and comparing them to EPA preliminary remediation goals (PRGs) (ECAR-4321). PRGs are risk-based soil concentrations derived from standardized equations combining exposure information assumptions with EPA toxicity data. They are soil concentrations that would not likely result in adverse health impacts under reasonable maximum exposure conditions for long-term/chronic exposures.
Table 4 contains estimated soil concentrations calculated from maximum deposition rates calculated by the atmospheric transport model. For both MFC and INTEC, maximum deposition occurs 200 m from the stack in the NE direction. For both MFC and INTEC, this distance would likely be the shortest distance from a production facility to a location outside the facility fence. The soil concentrations from these deposition rates were also used to determine impacts to biota (see Section 4.1.2.3). There are no permanent human receptors at these locations and the soil concentrations are much greater than concentrations at actual public receptor locations farther from the facilities. Thus, impacts to public receptors are bounded by use of these concentrations.
19 Table 4. Comparison of maximum radionuclide soil concentrations to EPA PRGs.
Radionuclide Maximum Soil Concentration outside MFC (pCi/g)a Maximum Soil Concentration outside INTEC (pCi/g)b EPA Total PRG for Soil Ingestion and Inhalationc Ratio of MFC Maximum Soil Concentration to EPA PRG Ratio of INTEC Maximum Soil Concentration to EPA PRG Mn-54 2.16E-02 1.49E-02 3.8E+03 5.69E-06 3.92E-06 Co-60 5.06E-05 3.49E-05 8.3E+01 6.09E-07 4.20E-07 Sr-90 3.89E+00 2.68E+00 8.9E+00 4.37E-01 3.01E-01 Tc-99 3.46E-09 2.39E-09 1.2E+02 2.89E-11 1.99E-11 Sb-125 1.56E-01 1.07E-01 5.4E+02 2.88E-04 1.98E-04 Cs-134 4.35E-02 3.00E-02 1.4E+02 3.11E-04 2.14E-04 Cs-135 5.69E-03 3.92E-03 9.6E+01 5.93E-05 4.09E-05 Cs-137 1.26E+00 8.72E-01 2.8E+01 4.51E-02 3.11E-02 Ce-144 1.85E-04 1.27E-04 2.2E+02 8.41E-07 5.79E-07 Eu-154 1.02E-01 7.03E-02 8.4E+01 1.21E-03 8.38E-04 Eu-155 1.72E-01 1.18E-01 6.7E+02 2.57E-04 1.76E-04 Np-237 2.22E-05 1.53E-05 6.2E+00 3.60E-06 2.48E-06 Pu-239 9.64E-03 6.64E-03 3.8E+00 2.54E-03 1.75E-03 Pu-240 9.42E-04 6.49E-04 3.8E+00 2.48E-04 1.71E-04 Am-241 3.88E-01 2.68E-01 4.8E+00 8.09E-02 5.58E-02 U-234 1.81E-02 1.25E-02 5.9E+00 3.08E-03 2.13E-03 U-235 7.61E-04 5.24E-04 5.7E+00 1.33E-04 9.19E-05 U-236 6.13E-04 4.23E-04 6.3E+00 9.77E-05 6.74E-05 U-238 4.88E-04 3.37E-04 4.4E+00 1.10E-04 7.59E-05 U-232 2.01E-04 1.38E-04 1.9E+00 1.08E-04 7.41E-05 U-233 5.62E-06 3.87E-06 5.8E+00 9.70E-07 6.69E-07 U-237 4.44E-07 3.06E-07 6.5E+04 6.83E-12 4.71E-12 Sum of Ratiosd 0.57 0.39
- a.
Soil concentrations near MFC based on annual emission rate of 5,000 kg (2,500 kg per facility). Facilities are assumed collocated.
- b.
Soil concentrations near INTEC based on annual emission rate of 2,500 kg.
- c.
PRGs are based on a target risk of 1E-06. PRG is the total PRG for the soil ingestion and inhalation of fugitive dust exposure pathways.
- d.
Sum of Ratios less than 1 indicates concentrations would not result in adverse human health impacts. The lifetime cancer risk is less than one in one million.
The results in Table 4 indicate maximum radionuclide soil concentrations are less than EPA PRGs. Sum of ratios values less than one is evidence that contaminated soils would not result in adverse human health impacts.
4.1.2.2 Waste Generation and Management Routine maintenance and operations would generate a variety of waste streams, including both radioactive and non-radioactive wastes. Non-radioactive wastes would include trash and waste found at any industrial facility, including common trash, wastewater, hydraulic and lubricating fluids, scrap metal, and possibly small amounts of hazardous waste (e.g., electronic circuit boards, solvent contaminated wipes).
Common trash would be disposed at the on-site industrial waste landfill. Hazardous waste/mixed waste would be accumulated and stored per federal and state regulations, treated and disposed at an off-site permitted/licensed facility. Solid LLW may include scrap metal, HEPA filters, used personal protective equipment, wipes, rags, and decontamination fluids. Solid LLW would be sent to an off-INL disposal facility permitted/licensed to accept LLW. Liquid LLW would be solidified and sent to an off-site disposal facility permitted/licensed to accept LLW. The volume of various LLW generated during routine operations are expected
20 to be less than 20 m3 per year (based on FY2018 generation rates at MFC); the additional LLW disposal from the proposed action is less than a 2.5% increase in the volume sent to off-site disposal facilities each year.
Cleaning for external contamination may use small amounts of nitric acid (about 2 liters per batch. During ceramic fuels processing using hydrochloric acid, hydrogen peroxide, and nitric acid would generate a MLLW.
MLLW when generated, would be accumulated and stored per federal and state regulations, treated if required, and disposed at an off-site permitted/licensed facility. For purposes of this analysis, it is assumed that the majority of materials comes from the processing of EBR-II spent fuel. EBR-II missions involved defense-related activities. Therefore, the transuranic waste generated from production of HALEU fuel would be defense-related and can be disposed at the Waste Isolation Pilot Plant (WIPP) (McFarlane 2001). Based on past operations of the FCF and the HALEU feedstock, less than 1 m3 of transuranic waste may be generated. Based on the starting point (HALEU feedstock) in the production of HALEU fuel, the HALEU process by definition would not generate Greater-Than-Class C waste nor would it generate High-Level Waste.
The environmental impacts associated with disposal and transportation of LLW are addressed in the Final Waste Management Programmatic Environmental Impact Statement for Managing Treatment, Storage, and Disposal of Radioactive and Hazardous Waste (DOE 1997a), the EA for the Replacement Capability for Disposal of Remote-Handled Low-Level Radioactive Waste Generated at the DOEs Idaho Site (DOE 2011b), and the Final Site-Wide Environmental Impact Statement for the Continued Operation of the DOE/National Nuclear Security Administration Nevada National Security Site and Off-Site Locations in the State of Nevada (DOE 2013a).
Handling and Examinations in Other MFC Facilities Fuel fabrication would result in waste generation at other facilities at MFC where the fuel can be analyzed. The materials and fuel specimens proposed for analysis would not be appreciably different from current testing.
Based on INLs FY2018 LLW generation rate of 934 m3, the increase in LLW generation would represent less than 2.5% of the volume generated at INL each year. MLLW may also be generated during these operations. If MLLW were generated, it would be accumulated and stored per Federal and state regulations, treated if required, and disposed at an off-site permitted/licensed facility. The proposed processes should generate less than 1 m3 of transuranic waste. The environmental impacts associated with disposal of transuranic waste are addressed in the Waste Isolation Pilot Plant Disposal Phase Final Supplemental Environmental Impact Statement (DOE 1997b).
4.1.2.3 Biological Resources The RESRAD-BIOTA (Version 1.8) computer code (http://resrad.evs.anl.gov/codes/resrad-biota/) was used to model radiation exposures to terrestrial biota resulting from soil contaminated by airborne releases from the HALEU processing facilities at INTEC and/or MFC. The Level 1 analysis in RESRAD-BIOTA provides generic limiting concentrations of radionuclides in environmental media, termed Biota Concentration Guides (BCG). Each biota concentration guide is the environmental concentrations of a given radionuclide in soil or water. The contaminated soil subsequently results in contamination in air and in different food sources used by biota. Both external radiation and internal radiation are considered in the dose assessment.
For the HALEU analysis, soil concentrations resulting from emissions under Alternatives 1a (MFC - 5000 kg feed processed per year for two years) and 1b (MFC and INTEC -2500 kg per each facility processed per year for two years) were evaluated. The maximum radionuclide concentrations in soil resulting from deposition under each scenario were evaluated for dose to terrestrial biota.
21 The potential radionuclide concentrations in surface soils around the INTEC and MFC were estimated using radionuclide-specific deposition rates modeled by the CAP88-PC computer code, as discussed in Section 4.1.2.1.
The locations at which the maximum deposition rates were estimated to occur were identified at 200 m northeast of MFC and 200 m northeast of INTEC. The concentrations of radionuclides in the soil at these locations were calculated using an algorithm which includes the deposition rate, radioactive decay and leaching of dissolved materials down through the soil via water infiltration (VFS-ID-ESER-NEPA-044, 2018). The calculated concentrations of radionuclides at the locations of maximum deposition are shown in Tables 5 and 6.
A Level 1 screening analysis was preformed using the maximum soil concentrations for each alternative scenario
[MFC for Alternative 1a (Table 5) and INTEC for Alternative 1b (Table 6)]. Because RESRAD-BIOTA does not offer Mn-54, Pu-240, U-232, U-236, and U-237 as input choices, these radionuclides were handled as follows: 1) Mn-54 was summed with Co-60; 2) Pu-240 was summed with Pu-239; 3) U-236 was summed with U-238; 4) U-232 was entered as Th-228 (a daughter in the decay series); and 5) U-237 was eliminated. The Level 1 screening analysis represents the most conservative estimate of impacts of contaminants in soil on terrestrial biota accessing the soil. The bases for these decisions are discussed in VFS-ID-ESER-NEPA-044.
The results of the analyses show that for each alternative terrestrial animals are the limiting species and the soil concentration/BCG ratios do not cumulatively exceed 1. This shows that the limits established for protection of terrestrial biota would not be exceeded for either alternative.
22 Table 5. Results of Level 1 RESRAD-BIOTA analysis of proposed HALEU releases at MFC (Alternative 1a).
Terrestrial animals are the limiting organism.
Terrestrial BCG Report for Level 1
Title:
HALEU - MFC (Summed) Total Ratio for Limiting Organism: 2.38E-01 (Summed) Soil Ratio for Limiting Organism: 2.38E-01 Terrestrial Animal Soil TOTAL Nuclidea Concentration (pCi/g)
BCG (pCi/g)
Ratio Limiting Organism Ratio Am-241 0.388 3.89E+03 9.96E-05 Yes 9.96E-05 Ce-144 0.000185 1.44E+03 1.28E-07 Yes 1.28E-07 Co-60 0.0217 6.92E+02 3.14E-05 Yes 3.14E-05 Cs-134 0.0435 1.13E+01 3.85E-03 Yes 3.85E-03 Cs-135 0.00569 2.62E+02 2.17E-05 Yes 2.17E-05 Cs-137 1.26 2.08E+01 6.07E-02 Yes 6.07E-02 Eu-154 0.102 1.29E+03 7.90E-05 Yes 7.90E-05 Eu-155 0.172 1.58E+04 1.09E-05 Yes 1.09E-05 Np-237 0.0000222 3.86E+03 5.75E-09 Yes 5.75E-09 Pu-239 0.0106 6.11E+03 1.73E-06 Yes 1.73E-06 Sb-125 0.156 3.52E+03 4.43E-05 Yes 4.43E-05 Sr-90 3.89 2.25E+01 1.73E-01 Yes 1.73E-01 Tc-99 0.00000000346 4.49E+03 7.70E-13 Yes 7.70E-13 Th-228 0.000201 5.30E+02 3.79E-07 Yes 3.79E-07 U-233 0.00000562 4.83E+03 1.16E-09 Yes 1.16E-09 U-234 0.0181 5.13E+03 3.53E-06 Yes 3.53E-06 U-235 0.000761 2.77E+03 2.75E-07 Yes 2.75E-07 U-238 0.0011 1.58E+03 6.97E-07 Yes 6.97E-07 Summed 2.38E-01 2.38E-01 Terrestrial Plant Soil TOTAL Nuclidea Concentration (pCi/g)
BCG (pCi/g)
Ratio Limiting Organism Ratio Am-241 0.00131 1.57E+04 8.33E-08 No 8.33E-08 Ce-144 0.000185 1.39E+04 1.33E-08 No 1.33E-08 Co-60 0.0217 6.13E+03 3.54E-06 No 3.54E-06 Cs-134 0.0435 1.09E+03 4.00E-05 No 4.00E-05 Cs-135 0.00569 2.81E+04 2.02E-07 No 2.02E-07 Cs-137 1.26 2.21E+03 5.71E-04 No 5.71E-04 Eu-154 0.102 1.25E+04 8.18E-06 No 8.18E-06 Eu-155 0.172 1.53E+05 1.13E-06 No 1.13E-06 Np-237 0.0000222 8.15E+03 2.73E-09 No 2.73E-09 Pu-239 0.0106 1.27E+04 8.36E-07 No 8.36E-07 Sb-125 0.156 3.49E+04 4.47E-06 No 4.47E-06 Sr-90 3.89 3.58E+03 1.09E-03 No 1.09E-03 Tc-99 0.00000000346 2.19E+04 1.58E-13 No 1.58E-13 Th-228 0.000201 6.42E+03 3.13E-08 No 3.13E-08 U-233 0.00000562 5.23E+04 1.07E-10 No 1.07E-10 U-234 0.0181 5.16E+04 3.51E-07 No 3.51E-07 U-235 0.000761 2.74E+04 2.77E-08 No 2.77E-08 U-238 0.0011 1.57E+04 7.00E-08 No 7.00E-08 Summed 1.74E-03 1.74E-03
23 Table 6. Results of Level 1 RESRAD-BIOTA analysis of proposed HALEU releases at INTEC (Alternative 1b).
Terrestrial animals are the limiting organism.
Terrestrial BCG Report for Level 1
Title:
HALEU - INTEC (Summed) Total Ratio for Limiting Organism: 1.64E-01 (Summed) Soil Ratio for Limiting Organism: 1.64E-01 Terrestrial Animal Soil TOTAL Nuclidea Concentration (pCi/g)
BCG (pCi/g)
Ratio Limiting Organism Ratio Am-241 0.268 3.89E+03 6.88E-05 Yes 6.88E-05 Ce-144 0.000127 1.44E+03 8.81E-08 Yes 8.81E-08 Co-60 0.0149 6.92E+02 2.15E-05 Yes 2.15E-05 Cs-134 0.03 1.13E+01 2.66E-03 Yes 2.66E-03 Cs-135 0.00292 2.62E+02 1.12E-05 Yes 1.12E-05 Cs-137 0.872 2.08E+01 4.20E-02 Yes 4.20E-02 Eu-154 0.0703 1.29E+03 5.45E-05 Yes 5.45E-05 Eu-155 0.0118 1.58E+04 7.45E-07 Yes 7.45E-07 Np-237 0.0000153 3.86E+03 3.96E-09 Yes 3.96E-09 Pu-239 0.00729 6.11E+03 1.19E-06 Yes 1.19E-06 Sb-125 0.107 3.52E+03 3.04E-05 Yes 3.04E-05 Sr-90 2.68 2.25E+01 1.19E-01 Yes 1.19E-01 Tc-99 0.00000000239 4.49E+03 5.32E-13 Yes 5.32E-13 Th-228 0.000138 5.30E+02 2.60E-07 Yes 2.60E-07 U-233 0.00000387 4.83E+03 8.02E-10 Yes 8.02E-10 U-234 0.0125 5.13E+03 2.44E-06 Yes 2.44E-06 U-235 0.000524 2.77E+03 1.89E-07 Yes 1.89E-07 U-238 0.00076 1.58E+03 4.82E-07 Yes 4.82E-07 Summed 1.64E-01 1.64E-01 Terrestrial Plant Soil TOTAL Nuclide Concentration (pCi/g)
BCG (pCi/g)
Ratio Limiting Organism Ratio Am-241 0.268 2.15E+04 1.24E-05 No 1.24E-05 Ce-144 0.000127 1.39E+04 9.12E-09 No 9.12E-09 Co-60 0.0149 6.13E+03 2.43E-06 No 2.43E-06 Cs-134 0.03 1.09E+03 2.76E-05 No 2.76E-05 Cs-135 0.00292 2.81E+04 1.04E-07 No 1.04E-07 Cs-137 0.872 2.21E+03 3.95E-04 No 3.95E-04 Eu-154 0.0703 1.25E+04 5.64E-06 No 5.64E-06 Eu-155 0.0118 1.53E+05 7.72E-08 No 7.72E-08 Np-237 0.0000153 8.15E+03 1.88E-09 No 1.88E-09 Pu-239 0.00729 1.27E+04 5.75E-07 No 5.75E-07 Sb-125 0.107 3.49E+04 3.07E-06 No 3.07E-06 Sr-90 2.68 3.58E+03 7.49E-04 No 7.49E-04 Tc-99 0.00000000239 2.19E+04 1.09E-13 No 1.09E-13 Th-228 0.000138 6.42E+03 2.15E-08 No 2.15E-08 U-233 0.00000387 5.23E+04 7.40E-11 No 7.40E-11 U-234 0.0125 5.16E+04 2.42E-07 No 2.42E-07 U-235 0.000524 2.74E+04 1.91E-08 No 1.91E-08 U-238 0.00076 1.57E+04 4.83E-08 No 4.83E-08 Summed 1.20E-03 1.20E-03
24 4.1.3 Accident Consequences Accident consequences for Alternative 1 (Proposed Action) were evaluated for events related to processing of HALEU. Accident types considered included thermal stress of fire on 50 kg uranium solids, spill or free-fall drop of molten metal, and accidents resulting in solid ingot free-fall drop or impact (ECAR-4310). The potential for nuclear criticality exists due to the quantity and form of material being processed. However, engineered and administrative controls would be incorporated into the facility and process operations to prevent and mitigate worker risk associated with this hazard.
DOE-Hdbk-3010-94 states that no significant airborne release is postulated from spill and impact of solid uranium, so those types of events are not addressed further. The handbook further states that release fractions for disturbed molten metal surface under dynamic conditions such as a spill or free-fall drop are higher than that for pieces or powder under thermal stress (fire). Therefore, the bounding and most severe postulated accident for the proposed action is a spill or free-fall drop of molten uranium during material processing. This accident could occur from an initiating event such as natural phenomena occurrence (i.e. severe seismic event), operator error, or from unspecified facility structural failures. The combined probability of initiating event and likelihood of equipment failure in this type of event of the magnitude to result in a material release during the molten phase of processing is judged to be no higher than a return frequency of 1E-02 to 1E-04 per year.
The needs of the proposed action are anticipated to be filled using more than one facility on the INL site. Dose consequence to the facility worker in an accident varies depending on the size of the room/building in which the accident occurs. Dose consequence to the public is dependent upon location of the activity and corresponding distance to the nearest site boundary where the public could be affected. Accident consequences in this document focus on molten material spill occurring at both the INTEC complex and MFC complex and use nominal values for building size and distance to the public.
To achieve the production requirements of the program, the two process lines could operate simultaneously and so for conservative analysis, double batch upsets are analyzed under accident conditions for airborne release.
Overview of Accident Analysis The accident analysis was conducted by using Radiological Safety Analysis Computer Program (RSAC) 7.2. RSAC 7.2 program is a radiological safety analysis tool that has been developed and used extensively at INL for calculating the doses to facility worker, collocated workers, and off-site public due to radiological releases. It has been independently verified and validated for these types of calculations.
Assumptions used for the accident analysis are as follows:
x Batch processing is 50 kg HALEU feedstock x
Potentially 2 batches simultaneously affected by accident x
HALEU feedstock is stored in closed containers when not in process and is therefore not considered material at risk during the analyzed accident x
Performance of HALEU in accidents (thermal stress, spill, drop, impact) follow that of uranium.
The HALEU is >99% uranium. The other elements identified are homogeneously entrained throughout the uranium matrix on ppm and ppb scale
25 x
This accident was analyzed as unmitigated with no credit taken for engineered controls or safety systems such as glovebox or ventilation systems x
Molten HALEU spills occur at a height of <4 m. Process equipment would be placed on the floor of the work area, and material would be molten only during processing x
A room/building volume of 1,700 m3 was assumed for facility worker dose calculations x
The composition of HALEU feedstock is based upon the best available information. Specific values are shown in ECAR-4310 and calculated from the maximum concentrations postulated in TEV-3537 x
The nearest INL boundary is located at about 5,000 m from MFC and 14,000 m from INTEC Bounding Inhalation Dose Consequences The calculation of 100 kg molten HALEU feedstock was postulated to be involved in a spill under assumed conditions as described above and worst case environmental conditions. Dose consequences were analyzed for the facility worker, collocated worker at 100 m, and the public receptor located at 5,000 m and 14,000 m. The analysis and results are documented in ECAR-4310, Evaluation of the Inhalation Dose Consequences for the HALEU Environmental Assessment. RSAC-7.2 was used to quantify the doses of the postulated accidents. The program is used to calculate the doses from the release of radionuclides to the atmosphere and uses the parameters of source term, plume dispersion, breathing rate, dose conversion factor for each receptor, and dry deposition in determining an estimated committed effective dose for each downwind receptor location.
Source term is calculated by multiplying material at risk quantity by damage ratio, airborne release fraction, respirable fraction, and leak path factor. The methodology for dose estimates is detailed in ECAR-4310. The results from the RSAC consequence calculations are shown in Table 7 below.
Radiologic Consequences Table 7. Summary of dose impacts for the highest consequence events for Alternative 1.
Receptor Dose Total Effective Dose (TED)
Latent Cancer Fatality (LCF)a Facility Worker (1,700 m3 building) 8.81 (rem/min)b 1.03E-02d Collocated Worker (100 m downwind) 997(mrem)c 4.09E-04 Offsite Member of the Public (5,000 m downwind) 29.4E(mrem)c 1.62E-05 Offsite Member of the Public (14,000 m downwind) 9.10(mrem)c 5.01E-06
- a. conservatively estimated based on ICRP Publication 103 health effects
- b. 50 yr TED rem per minute of exposure time. If smaller room volumes are used, process configuration and parameters would be adjusted to maintain worker dose below the calculated values
- c. 50 yr TED millirem
26 4.1.4 Impacts of Transportation Transportation of HALEU feedstock, fuel alloy, and cast or clad fuel under the proposed action would occur between INL facilities on the route as shown in Figure 3, which is on roadways controlled by INL security. For transport between MFC and INTEC facilities on the INL site, an appropriate shipping container for each material would be used such as the Hot Fuel Examination Facility-5 cask.
Figure 3. Transport route between INTEC and MFC.
The assessment of transportation accident consequences to workers and the public for on-site transport is addressed in, Environmental Assessment for the Multipurpose Haul Road within Idaho National Laboratory, DOE/EA-1772 (DOE 2010). HALEU feedstock would be transported in solid form; therefore, no significant airborne release is postulated from spill and impact of solid uranium. It is not credible that a shipment could become molten under plausible transportation accidents. As shown in the previous section, for double batch size quantities, the worst-case air release of molten material HALEU feedstock, the dose consequence is expected to be substantially less than that addressed in DOE/EA-1772 (Haul Road EA). Therefore, the consequence analysis of DOE/EA-1772 is appropriate and bounding for HALEU transportation. Safety during transportation is also assured using DOE-approved transport plans, which analyze reasonable and bounding accident scenarios.
4.1.5 Impacts of Intentional and Destructive Acts DOE considered Impacts of intentional acts of destruction occurring at an INL facility or during transport on INL.
INLs protective force mitigates the potential for an act of sabotage occurring on site. INL routinely uses a variety of measures to mitigate the likelihood and consequences of intentional destructive acts. The DOE maintains a highly trained and equipped protective force intended to prevent attacks against and entry into the facilities.
The protective force monitors and patrols site perimeters to prevent unauthorized entry.
27 Access to INL roads would be restricted during transport of radioactive materials. Security measures would be in place to mitigate the likelihood and consequences of sabotage. Transportation crewmembers would be screened for behavioral and substance abuse issues and would receive safety and security training. Crewmembers would conduct a thorough inspection of vehicles and loads before transport. During transport, crewmembers have a means of communication and immediately report suspicious activity encountered while in route.
Accident analyses for the proposed action are evaluated based on conservative assumptions using parameters resulting in the highest postulated dose to workers and public receptors, therefore, any acts of sabotage, should they occur, would be expected to result in consequences that would be bounded by the results of accident scenarios detailed above.
4.1.6 Sustainability The only anticipated sources of greenhouse gas (GHG) emissions would be from a diesel backup generator.
Emissions from the transport of nuclear material would also be included. BEA uses 100% renewable diesel fuel, which would result in 0 metric tons carbon dioxide equivalent (MT CO2e) of anthropogenic GHG emissions. If 100% renewable diesel is not available, the total anthropogenic GHG emissions are estimated to be less than 0.5 MT CO2e, assuming heavy-duty vehicle burning 100% diesel and taking 20 one-way trips at 20 miles per trip.
4.1.7 Cumulative Impacts DOE reviewed the resources at risk; geographic boundaries; past, present, and reasonably foreseeable future actions; and baseline information in determining the significance of cumulative impacts. The review was assessed for construction, transportation, normal operations, and potential impacts of accidents. Conclusions are as follows:
x Cumulative impacts to historic properties cannot be evaluated until Section 106 has been completed. Section 106 under the proposed action alternatives has been deferred; as such, cumulative impacts to historic properties would be evaluated under the MOA and associated stipulations identified in the NEPA decision for completion of Section 106. (see Section 4.1.1) x The proposed action would not create new facility or building footprint; therefore, there would be no or negligible cumulative impacts to biological resources. There may be low short-term impact to INLs ecological resources. (see Section 4.1.2.3) x During normal operations, cumulative radiologic, waste generating, or sustainability impacts would be minimal. Radiologic releases during normal operations would not result in adverse health impacts. Additional waste volumes would be small compared to current disposal volumes at INL.
Additional GHG emissions would be negligible compared to INL Site-wide amounts (see Section 4.1.6).
The maximum total annual estimated dose from atmospheric emissions to a maximally exposed off-site individual reported for INL compliance in year 2017 is 0.008 mrem (DOE ID 2018). Inclusion of the conservatively estimated maximum annual dose contribution from HALEU fuel production of 1.6 mrem (Alternative 1b) would result in a total annual estimated dose at Frenchmans Cabin of 1.61 mrem. The estimated annual dose of 0.74 mrem (Alternative 1a) would result in a total annual dose estimate of 0.75 mrem. Although the Alternative 1a and 1b doses from HALEU fuel production are much larger than the dose from current emissions, the doses from
28 HALEU fuel production are based on conservative emission estimates that take no credit for mitigation. The actual emissions and doses are expected to be much less.
There are several proposed projects at the INL Site that DOE considers reasonably foreseeable that would include radiological emissions that could contribute to cumulative impacts. Those that DOE reviewed include:
x Remote-Handled LLW Disposal Facility x
Plutonium-238 Production for Radioisotope Power Systems x
Recapitalization of Infrastructure Supporting Naval Spent Nuclear Fuel Handling x
Resumption of Transient Testing using the TREAT facility x
Radiological Response Training Ranges x
National Security Test Range Table 8 presents the estimated dose from each reasonably foreseeable project to a MEI. Most are screening-level dose estimates which means the analysis used conservative assumptions (e.g. no mitigation) to bound the dose estimate. In addition, some projects estimate dose at the nearest off-site public receptor location which may be several miles from Frenchmans Cabin. For example, the location of the public receptor dose presented for the National Security Test Range is near the INL Site northeast boundary, more than 38 miles from the INL MEI location at Frenchmans Cabin. If the doses for each project are conservatively assumed to occur at Frenchmans Cabin (which they do not), the total dose from reasonably foreseeable projects, including HALEU fuel production, is 1.67 mrem/yr. If combined with the current maximum total annual estimated dose reported for INL compliance (0.008 mrem in 2017), the dose from current and reasonably foreseeable future actions on the INL Site would be 1.68 mrem as indicated in Table 8. Although the actual dose is expected to be much less, this estimated dose is still much lower than the 10 mrem annual dose standard.
The potential additive impacts from implementing Alternative 1a or 1b for HALEU fuel production are determined to be collectively small and would have little impact to reasonably foreseeable future actions or current operations.
29 Table 8 Estimated annual air pathway dose (mrem) from normal operations to the maximally exposed off-site individual from the above proposed projects, including the estimated dose from HALEU fuel production.
Reasonably Foreseeable Future Action Estimated Annual Air Pathway Dose (mrem)
New DOE Remote-Handled LLW Disposal Facility (DOE/ID 2018) 0.0074a Plutonium-238 Production for Radioisotope Power Systems (DOE 2013b) 0.00000026b Recapitalization of Infrastructure Supporting Naval Spent Nuclear Fuel Handling (DOE 2016) 0.0006c TREAT (DOE 2014) 0.0011a Radiological Response Training Range (North Test Range) (ECAR 3533) 0.043d Radiological Response Training Range (South Test Range) (ECAR 3533) 0.00031a National Security Test Range (ECAR 3565) 0.037e HALEU fuel Production 1.6a,f Total of Reasonably Foreseeable Future Actions on the INL Site 1.69g Current (2017) Annual Estimated INL Emissions (DOE-ID, 2018) 0.008h Total of Current and Reasonably Foreseeable Future Actions on the INL Site 1.70i
- a. Dose calculated at Frenchmans Cabin, typically INLs MEI for annual NESHAP evaluation.
- b. Receptor location is not clear. Conservatively assumed at Frenchmans Cabin.
- c. Dose calculated at INL boundary northwest of Navel Reactor Facility (NRF). Dose at Frenchman Cabin likely much lower.
- d.
Dose calculated at INL boundary northeast of Specific Manufacturing Capability (SMC). Dose at Frenchmans Cabin likely much lower.
- e. Sum of doses from New Explosive Test Area and Radiological Training Pad calculated at separate locations northeast of MFC near Mud Lake. Dose at Frenchmans Cabin likely much lower.
- f. Maximum dose from Alternative 1b (1.6 mrem/year) is presented. Alternative 1a dose at Frenchmans Cabin is 0.74 mrem/year.
- g. This total represents the air impact from reasonably foreseeable future actions and assumes they occur at Frenchmans Cabin.
- h. Dose at MEI location (Frenchmans Cabin) from 2017 INL emissions (INL 2018). The 10-yr (2008-2017) average dose is 0.05 mrem/year.
- i. This total represents air impact from current and reasonably foreseeable future actions at INL. It conservatively assumes the dose from each facility was calculated at the same location (Frenchmans Cabin) which they were not.
4.2 Alternative 2 - No Action Under the No Action Alternative, blending uranium separated from sodium-bonded fuel through the electrometallurgical process with depleted uranium would continue at INL as analyzed in the Sodium Bonded EIS. The Sodium Bonded EIS, DOE/EIS-306 (DOE 2000) evaluated treating about 5 metric tons of heavy metal of sodium-bonded spent nuclear fuel per year. Appendix E, Section E.4.1, contains details on the process duration and the amount of blanket and driver spent nuclear fuel treated annually.
30 4.3 Summary of Environmental Impacts Table 9 summarizes impacts of the proposed action for air, cultural and biological resources and waste generation and management.
Table 9. Summary of environmental impacts.a Resource Alternative #1: Proposed Action Impacts -- Construction Constructions (Section 4.1.1) x Project activities may generate fugitive dust as the result of construction or modification due to possible soil disturbance or excavation activities.
x Materials containing asbestos could be disturbed.
x INL has not determined which buildings at either MFC or INTEC would be used under the proposed action; as such, DOE would evaluate impacts to historic properties before making the NEPA decision, resulting in deferment of Section 106 as per 36 CFR 800.14(b)(1)(ii).
x The modifications for fuel fabrication would generate non-radioactive electronic waste, scrap metal, and other construction-related debris. Construction debris, electronic waste, and scrap metal would be recycled to the extent possible.
Impacts - Normal Operations Non-Radiologic Atmospheric Impacts -
chemical pollutants (Section 4.1.2.1) x Nonradiological emissions would be minimal during operational stages.
Atmospheric Pathway (Section 4.1.2.1 x A conservative assessment of radionuclide releases during anticipated normal operations indicates cumulative doses from all INL sources would be well below the 10 mrem/year dose standard for a member of the public at the INL MEI location (see Section 4.1.7). Estimated doses to collocated workers would be well below the 5,000-mrem dose standard.
Waste Generation (Section 4.1.2.2 x The volume of various LLW generated during routine operations are expected to be less than 20 m3 per year (based on past generation rates at MFC). The additional LLW disposal from these operations would represent less than a 2.5% increase in the volume sent to off-site disposal facilities each year.
x Less than 1 m3 of transuranic waste is expected to be generated.
x The materials and fuel specimens proposed for analysis would not be appreciably different from current testing.
Biological Resources (Section 4.1.2.3) x Terrestrial animals are the limiting species and modeling shows that the soil concentration/BCG ratios do not cumulatively exceed 1 for terrestrial animals or plants, thus, the limits established for protection of terrestrial biota would not be exceeded for either alternative.
Impacts - Potential Accidents Accidents (Section 4.1.3) x The committed dose to facility workers from the most severe postulated accident is conservatively estimated to be 8.81 rem/min of exposure time. Facility worker dose is further reduced by engineered and administrative controls and procedures and by using protective equipment.
x Committed dose estimates for collocated workers would be 997 millirem and would result in 4.09E-04 (or 1 chance in 2400) LCFs. Estimated dose to the public at 5,000 m and 14,000 m would be 29.4 millirem and 9.1 millirem respectively with corresponding LCFs estimated at 1.62 E-05 (1 in 62,000) and 5.01E-6 (1 in 200,000). These consequences would likewise be reduced by applying engineered and administrative controls.
Impacts -- Transportation Transportation (Section 4.1.4) x HALEU feedstock would be transported in solid form; therefore, no significant airborne release is postulated from spill and impact of solid uranium.
x The consequence analysis of DOE/EA-1772 is appropriate and bounding for HALEU transportation.
31 Resource Alternative #1: Proposed Action Intentional and Destructive Acts Destructive Acts (Section 4.1.5) x INL routinely uses a variety of measures to mitigate the likelihood and consequences of intentional destructive acts.
- a.
Alternative #2 No Action results in no change to environmental impact from current operations.
32 5 PERMITS AND REGULATORY REQUIREMENTS Each alternative would be required to adhere to federal, state, and local regulations and obtain appropriate permits before constructing, modifying, or operating facilities, equipment, or processes. Below is a list of federal, state, and local regulations and permits that either of the alternatives may be required to adhere to or to obtain. The No Action alternative complies with permits and applicable regulatory requirements. DOE would be responsible for identifying a comprehensive list of applicable regulations and permits for the selected actions.
Activities that affect, or may affect, the safety of DOE nuclear facilities must also comply with the requirements of 10 CFR 830, Nuclear Safety Management.
Air Radiologic air emissions from the INL must meet the EPA limit of 10 mrem/year for demonstration of compliance with National Environmental Standards for Emissions of Radionuclides Other Than Radon from Department of Energy Facilities (40 CFR 61, Subpart H). In addition, because each processing facility would exceed the 0.1 mrem/yr limit, each facility may require an Application to Construct under 40 CFR 61.96 and a state PTC under IDAPA 58.01.01.200 for a radiological source requiring a continuous stack monitor to be built per ANSI N13.1 (2011).
Emissions of hazardous air pollutants, criteria pollutants and state toxic air pollutants would be evaluated for compliance with Permit to Construct P-2015-0023, INL Permit to Construct and Facility Emission Cap. If emissions are under the facility wide limits of Permit Condition 2.2 and comply with the Notice and Recordkeeping of Ambient Concentration Estimates of Permit Condition 2.6 no permit revision would be required. If the ambient concentration exceeds significant contribution levels of IDAPA 58.01.01.006.109, a separate PTC would be required.
Biological In analyzing the potential ecological impacts of the action alternative for the proposed action, DOE has followed the requirements of the Endangered Species Act (16 USC §1531 et seq.) and has reviewed the most current lists for threatened and endangered plant and animal species. Other federal laws that could apply include: the Fish and Wildlife Coordination Act (16 USC § 661 et seq.), Bald and Golden Eagle Protection Act (16 USC § 668), and the Migratory Bird Treaty Act (16 USC § 715-715s).
Cultural Cultural resources are managed at the INL Site according to a tailored approach outlined in INLs Cultural Resource Management Plan (DOE-ID 2016) and corresponding Programmatic Agreement executed among DOE, the Idaho SHPO, and the Advisory Council on Historic Preservation. Shoshone-Bannock tribal interests in INL resources and activities are addressed in an Agreement in Principle between DOE and the Shoshone-Bannock Tribes.
Section 106 of the National Historic Preservation Act (NHPA) directs any federal agency undertaking or licensing any activity, to prior to the approval of the expenditure of any federal funds on the undertaking or prior to the issuance of any license, as the case may be, [to] take into account the effect of the undertaking on any district, site, building, structure or object that is included in or eligible for inclusion in the National Register. To assess the impact of such an undertaking, an agency must know whether any affected district, site, building, structure, or object is eligible for the NRHP. (Section 110 of the NHPA requires a federal agency to assume responsibility
33 for historic properties it owns or controls. Historic properties must be identified, evaluated, documented, and nominated to the NRHP, if appropriate. Thus, Section 110 obliges an agency to preserve its historic properties and manage those properties in compliance with Section 106.
DOE has negotiated a following process for deferring Section 106 under the proposed action for Alternative 1 with the Idaho SHPO, per 36 CFR 800.14(b )(1)(ii). The following process was outlined in a letter from DOE to the Idaho SHPO on October 10, 2018:
- 1) The Idaho SHPO will be allowed the opportunity to review the language in the EA regarding deferring Section 106 once the document has been made available for public comment, as per 36 CFR 800.8(c)(2)(i);
- 2) DOE will prepare a MOA outlining how the Section 106 process will be completed, once determinations are made regarding the specific buildings involved in the undertaking.
- 3) The MOA will be signed prior to the NEPA decision. The NEPA decision will include stipulations for completing the Section 106 process.
Sustainability Executive Order 13834 Efficient Federal Operations; DOEs 2016 Strategic Sustainability Performance Plan; and DOE Order 436.1, Departmental Sustainability contains requirements and assign responsibilities for managing sustainability within DOE to carryout missions in a sustainable manner. These requirements also include provisions to institute wholesale cultural change to factor sustainability and GHG reductions into DOE decisions, and to achieve DOEs sustainability goals established in its Strategic Sustainability Performance Plan.
Per DOEs 2016 Strategic Sustainability Performance Plan Goal 2, alterations or renovations of buildings greater than 5,000 GSF must comply with the Guiding Principles. There are 26 Guiding Principles required for a building to meet compliance. Some are at no cost (e.g., non-smoking policy) and others require investments (e.g., water, gas, electricity meter installations). Executive Order 13834 states that new construction and major renovations conform to applicable building energy efficiency requirements and sustainable design principles; consider building efficiency when renewing or entering into leases; practice using and optimizing space; and annually assess and report on building conformance to sustainability metrics. These requirements would be incorporated and addressed, where applicable.
Nuclear Safety 10 CFR 830 sets forth requirements that must be implemented in a manner that gives reasonable assurance of adequate protection of workers, the public, and the environment from adverse consequences, taking into account the work to be performed and the associated hazards.
34 6 COORDINATION AND CONSULTATION DURING EA PREPARATION Shoshone-Bannock Tribes DOE briefed Shoshone-Bannock Tribes staff on the HALEU EA and project on September 5 and October 24, 2018, and the Fort Hall Business Council on October 30, 2018.
DOE briefed the Heritage Tribal Office on October 10, 2018 on the HALEU Project, the plan to defer Section 106, and the Memorandum of Agreement.
INL Oversight Office DOE briefed Kerry Martin (State of Idahos INL Oversight Office Manager), her staff, and Mark Clough (Idaho DEQ) on the HALEU EA on October 16, 2018.
Idaho State Historic Preservation Office DOE has negotiated a process for deferring Section 106 under the proposed action for Alternative 1 with the Idaho SHPO, per 36 CFR 800.14(b )(1)(ii).
Congressional DOE briefed staff members of Sen Risch, Sen Crapo, and Congressman Simpson on October 18, 2018.
35 7 REFERENCES ECAR-3533, 2018, Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL Radiological Response Training Range, Revision 2, A.J. Sondrup, December 2018.
ECAR-3565. 2018, Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL National Security Test Range, Revision 1, A.J. Sondrup, December 2018.
ECAR-4310, 2018, Evaluation of the Inhalation Dose Consequences for the HALEU Environmental Assessment, Revision 0, B. Christensen, October 2018.
ECAR-4321, 2018, Evaluation of Impacts from Radiological Air Emissions for the HALEU Environmental Assessment, Revision 0, A.J. Sondrup, October 2018.
ICRP-68, Dose Coefficients for Intakes of Radionuclides by Workers, International Commission on Radiological Protection, 1994.
ICRP-72, Age-dependent Doses from Intakes of Radionuclides, International Commission on Radiological Protection, 1996.
McFarlane, H. F., 2001, The Defense Programs Origin of Transuranic Waste at ANL-W, ANL-NT-192, Argonne National Laboratory - West, November 2001.
TEV-3537, 2018, Isotopic Characterization of HALEU from EBR-II Drive Fuel Processing, Revision 0, D. Vaden, October 2018.
U.S. Department of Energy Idaho Operations Office (DOE-ID), 1994, Track 2 Sites: Guidance for Assessing Low Probability Hazard Sites at the INEL, DOE/ID-10389, August 1994.
U.S. Department of Energy (DOE), 2000, Final Environmental Impact Statement for the Treatment and Management of Sodium-Bonded Spent Nuclear Fuel, Volume 1, U.S. Department of Energy, Office of Nuclear Energy, Science and Technology, Washington, DC, DOE/EIS-306, July 2000.
U.S. Department of Energy (DOE), 2010, Idaho National Laboratory Radiological Response Training Range Environmental Assessment, DOE/EA-1776, U.S. Department of Energy, October 2010.
U.S. Department of Energy (DOE), 2011, Environmental Assessment for the Replacement Capability for Disposal of Remote-Handled Low-Level Radioactive Waste Generated at the Department of Energys Idaho Site, DOE/EA-1793, U.S. Department of Energy, December 2011.
U.S. Department of Energy (DOE), 2013a, Final Site-Wide Environmental Impact Statement for the Continued Operation of the DOE/National Nuclear Security Administration Nevada National Security Site and Off-Site Locations in the State of Nevada, DOE/EIS-0426, February, 2013 U.S. Department of Energy (DOE), 2013b, Supplemental Analysis for the Nuclear Infrastructure Programmatic Environmental Impact Statement for Plutonium-238 Production for Radioisotope Power Systems, DOE/EIS-0310-SA-02, U.S. Department of Energy, Washington, D.C. September 2013.
U.S. Department of Energy (DOE), 2016, Final Environmental Impact Statement for the Recapitalization of Infrastructure Supporting Naval Spent Nuclear Fuel Handling at the Idaho National Laboratory, DOE/EIS-0453-F, Appendix D, U.S. Department of Energy, October 2016.
U.S. Department of Energy (DOE), 2014, Environmental Assessment for the Resumption of Transient Testing of Nuclear Fuels and Materials, DOE/EA-1954, U.S. Department of Energy, February 2014.
36 U.S. Department of Energy Idaho Operations Office (DOE-ID), 2016, Idaho National Laboratory Cultural Resource Management Plan, U.S. Department of Energy - Idaho Operations Office, DOE/ID-10997, June 2016.
U.S. Department of Energy Idaho Operations Office (DOE-ID), 2018, National Emission Standards for Hazardous Air Pollutants - Calendar Year 2017 INL Report for Radionuclides, DOE/ID-11441, June 2018.
U.S. Department of Energy (DOE), 2010, Environmental Assessment for the Multipurpose Haul road Within the Idaho National Laboratory Site, DOE/EA-1772, August 2010.
VFS-ID-ESER-NEPA-044, 2018, Analysis of Radiological Impacts to Terrestrial Biota in Support of Environmental Assessment for Use of DOE-Owned High-Assay Low-Enriched Uranium Stored at Idaho National Laboratory, Revision 0, M.J. Case and D. Halford, Veolia Nuclear Solutions - Federal Services, October 2018.
Code of Federal Regulations Referenced in this EA 10 CFR 830 - Nuclear Safety Management 10 CFR 835.202 -- Occupational dose limits for general employees 36 CFR 800.14(b)(1)(ii) - Federal Agency Program Alternatives, Use of Programmatic Agreements, Advisory Council on Historic Preservation 36 CFR 800.8(c)(2)(i) - Coordination with the National Environmental Policy Act, Review of Environmental Documents.
40 CFR 61 Appendix D - Methods for Estimating Radionuclide Emission 40 CFR Part 61, Subpart H - National Emission Standards for Emissions of Radionuclides other than Radon from Department of Energy Facilities 40 CFR 61.96, Subpart H - Applications to construct or modify 40 CFR Part 191 - Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes.
40 CFR 1500.2[e] - Council on Environmental Quality, Purpose, Policy, and Mandates
37 APPENDIX A - Comment Responses The formal comment period for the Draft EA for the Use of DOE-Owned High-Assay Low-Enriched Uranium ended on November 30, 2018. DOE received several comments from interested parties and groups. DOE has reprinted these comments verbatim as received. The following pages contain DOEs responses to the comments. This document is being prepared as an appendix to the Final EA and DOE will send copies to those individuals and groups who gave DOE comments. This document will also be available online and to other interested parties upon request. Comments are organized by commenter in alphabetical order (see Table A-1).
Items added to the EA are called out in individual comments.
38 Commenters Table A-1. List of commenters, commenters affiliation (if any), and page number of comment response.
Comment
- s Commenter Commenter (affiliation, if any)
Page # for
Response
1 Aref Alexander Adibi, Real Estate Broker Century 21, Northwest, Krikland, WA 39 2
Nima Ashkeboussi Nuclear Energy Institute 40 3
Larae Bill, Cultural Resource Specialist The Shoshone-Bannock Tribes 41 4
Beatrice Brailsford, Nuclear Program Director Snake River Alliance 45 5
Chuck Broscious, President Environmental Defense Institute 48 6
Jason Charles Self 53 7
Benjamin Cox Self 53 8
Suketu Gandi Self 54 9
Peter Hastings, Vice President Kairos Power 55 10 Lars Jorgensen, CEO ThorCon US 56 11 Edwin Lyman, Senior Scientist Union of Concerned Scientists 58 12 Bob McGarn Self 59 13 Rich Powell, Executive Director David Blee, President and CEO ClearPath U.S. Nuclear Industry Council 60 14 Peter Rickards Self 62 15 Ann Rydalch Self 66 16 Abhijit Sengupta Self 67 17 Tami Thatcher Self 68 18 Noy Xayavong Self 83
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
39 Aref Alexander Adibi, Real Estate Broker, Century 21 Comment(s) 1:
Response(s) 1: Mr. Adibi, DOE acknowledges your comment supporting the proposed action. Thank you.
1
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
40 Nima Ashkeboussi, Nuclear Energy Institute Comment(s) 2:
Response(s) 2: Ms. Ashkeboussi, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
2
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
41 Larae Bill, Cultural Resource Specialist, The Shoshone-Bannock Tribes Comment(s) 3 - 8:
3 4
5 6
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
42 Response(s) 3 - 8: Ms. Bill, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
- 3. The Department of Energy recognizes the unique relationship we have with the Shoshone-Bannock Tribes, who are a sovereign entity and with whom we have a trust responsibility to protect their people, cultural resources, ancestral homeland and current reservation land. DOE reached out to Tribal subject matter experts immediately after the EA Determination for this project was signed, and offered Tribal staff a briefing on the scope of the EA before it was prepared. This briefing was carried out with Tribal staff on September 5, 2018 in Idaho Falls.
After most of the substantial work on the EA was completed, DOE again offered the Tribal staff a briefing to bring them up to speed on the likely results of the analysis. This briefing was given to Tribal staff on October 24, 2018 in Fort Hall. Finally, as work on the EA was completed, DOE offered the Fort Hall Business Council a detailed briefing on the scope and findings of the EA, which was carried out at Fort Hall on October 30. 2018, the day before the draft EA was released for public review and comment.
DOE believes these sincere attempts at early and thorough communications with the Tribes more than fulfill the requirements of the Agreement in Principle between the agency and the Tribes, which states: (DOE agrees to the following) Arrange and give presentations or briefings to Tribal audiences for those NEPA 7
8
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
43 activities that may affect the Tribes, and will facilitate the interface with DOE-HQ. The Tribes will have opportunity to participate in the normal public process leading to issuance of final EAs and EISs.
- 4. Response: 36 CFR Part 800, Protection of Historic Properties, allows federal agencies to defer final identification and evaluation of historic properties if specifically provided for in a formal agreement or in the documents used by an agency official to comply with NEPA. The specific buildings that would be used for the project have not yet been determined and, therefore, the effects on historic properties cannot be fully determined prior to approval of the undertaking (i.e. making a NEPA decision). DOE consulted with the Idaho State Historic Preservation Office (SHPO) and negotiated a process to defer section 106 and a draft memorandum of agreement (MOA) was developed to outline how the section 106 process would be completed once determinations are made regarding specific buildings involved in the undertaking. DOE is committed to meeting its legal obligations to complete the section 106 process. DOE will make a modification to the final EA that identifies the significance of the buildings under consideration, potential modifications that may be needed to the buildings, and the types of associated mitigative actions that may be taken. DOE formally notified the Honorable Chairman Nathan Small, Fort Hall Business Council, on October 11, 2018, of the request to SHPO to defer section 106 (CLN190064) and formally transmitted the draft MOA to Honorable Chairman Small on October 30, 2018, for review (CLN190149). DOE will modify the MOA to add the Tribes to the signatory page as a Concurring Party and transmit the final MOA to the Tribes for signature.
- 5. The EA contains calculations of dose to public receptors during normal operations (unmitigated dose) at several receptor locations including Atomic City.
Middle Butte is in the pathway between MFC and Atomic City. DOE understands Middle Butte is a Tribal sacred site and that Tribal members go to Middle Butte for ceremonial activities. In evaluating potential effective dose to public receptors, the draft EA estimates the effective dose received by a resident in Atomic City at 1.9 mrem per year under Alternative 1a and estimates the highest potential dose at a publicly accessible location, located at a residence nearest MFC, to be 2.4 mrem per year under Alternative 1a. The federal standard set by 40 CFR 61, Subpart H, sets the dose limit for public exposure at 10 mrem per year. DOE does not have data on the number and duration of visits made to Middle Butte by Tribal members each year. Using the public dose estimates as best available data, DOE believes the potential effective dose to Tribal members going to Middle Butte would be no higher than the public receptor doses estimated in the draft EA.
- 6. Depending on the direction from the production facility, radionuclide soil deposition rates from air emissions peak at distances of 100 m to 300 m from the facility. As stated in the EA, the highest deposition rates were at approximately 200 m in the northeast direction, and the potential soil contamination is not likely to result in adverse health impacts under reasonable maximum exposure conditions for long-term chronic exposures. Since long-term exposures are not possible on the INL Site, the actual impacts would be much less. In addition, deposition rates beyond 200 m decrease rapidly with distance from the facility.
The soil concentrations at Middle Butte and anywhere outside the INL Site would be a fraction of the soil concentrations presented in the EA and thus soil impacts are bounded by those presented in the EA. Furthermore, the public doses presented in the EA include direct radiation from soil contamination. Thus, the impacts of soil deposition are included in the impact assessment.
- 7. The draft EA evaluated radiation exposures to terrestrial plants and animals resulting from the proposed HALEU project. Although the dose to humans was not estimated in the RESRAD-BIOTA calculations, the limiting Biota Concentration Guides (BCGs) are so conservative that the dose to humans resulting from eating contaminated biota at the BCG levels is well below the limit established by DOE for the protection of public health (100 mrem/yr). That is, if a person eats 8 oz (227 g) of meat that is contaminated at the BCG level every day for a year, he or she would not exceed the 100 mrem/yr dose limit. For example, the two highest contributors to biota dose were determined to be strontium-90 (Sr-90) and cesium-137 (Cs-137). The BGCs established for these radionuclides are 3.89 and 1.26 pCi/gsoil, respectively. Using concentration ratios (i.e., concentrationmeat/concentrationsoil) of 17 for Sr-90 and 67 for Cs-137, as provided in RESRAD-Biota documentation, the resulting concentrations in meat of a game animal grazing exclusively in the contaminated area for a year would be 66.13 pCi/g (Sr-90) and 84.42 pCi/g (Cs-137). Ingestion dose coefficients may be found in the Federal Guidance Report 13 database
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
44 (https://www.epa.gov/radiation/federal-guidance-report-no-13-cancer-risk-coefficients-environmental-exposure). They are 1.02x10-14 mrem/pCiSr-90 and 5.02x10-13 mrem/pCiCs-137. Assuming a person eats 227 g/day (8 ounces) for a year, the total dose received would be 3.57 x 10-6 mrem/yr, well below the DOE dose limit of 100 mrem/yr. This is conservative because the calculations do not take into effect bioelimination of the radionuclides by the animals during the year and the fact that game animals would visit the project area rarely and for minimal time so the actual doses would be even lower.
- 8. The cumulative impacts presented in Table 8 of the EA include all potential doses from current operations, reasonably foreseeable actions and the proposed action. Although the doses for each action in the table are not all calculated at the current INL Site maximally exposed individual (MEI) location which is Frenchman's Cabin, they are conservatively added together as if they all occur at Frenchman's cabin. If the HALEU emissions estimated in the EA were actual emissions, the INL MEI location would likely move from Frenchman's cabin to a location nearer INTEC or MFC depending on the alternative selected. However, the maximum annual dose would not be higher than the maximum dose predicted in the EA (see Table 2) plus the annual INL radiological NESHAP dose (0.008 mrem/yr in 2017, see Table 8).
Receptors located N, NNE and NE of MFC and INTEC are much farther away than the receptor locations examined in the EA. In addition, doses in this direction at the same distance are less than doses in the S, SSW and SW directions. The predominant wind direction is generally to the NE during the day, but higher speeds and unstable-to-neutral atmospheric conditions result in greater dispersion and dilution. Less dispersion occurs during the nighttime and early morning hours when atmospheric conditions are more stable and wind speeds are slower and typically to the SW. Therefore, doses in the NE direction would be less than those presented in the EA.
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
45 Beatrice Brailsford, Nuclear Program Director, Snake River Alliance Comment(s): 9 -15 Response(s) 9 - 15: Ms. Brailsford, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
14 12 15 13 11 10 9
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
46
- 9. The U.S. nuclear industry has been working on advanced reactors (including micro-reactors) for the over a decade. Numerous companies/vendors contacted the Department of Energy and Idaho National Laboratory to obtain advice and technical assistance/support in developing advanced reactor designs. One issue that has been identified by vendors is the availability of HALEU fuel. As with any new technology, the supply chain would only become available after a demonstration of the new technology and concept. Some of the advanced reactors vendors requiring HALEU have been in discussion with NRC concerning licensing and operations of these new designs. In addition, the National Defense Authorization Bill section 327 instructed the Department to work with commercial vendors to demonstrate a micro-reactor.
- 10. As discussed in this EA, the proposed action would make 10 MT of HALEU feedstock produced through the electrometallurgical treatment (EMT) process, and other small quantities of HALEU feedstock stored at INL, available to support early-stage demonstration by the commercial nuclear industry and government agencies. The ongoing EMT process converts sodium-bonded spent nuclear fuel into waste forms suitable for disposal as high-level waste and a HALEU product that is unsuitable for diversion to nuclear weapons, but could be either reused in fuel or disposed of as waste. The 10 MT HALEU feedstock proposed for use in the production of HALEU fuel is largely the result of processing EBR-II driver fuel. EMT of the EBR-II driver fuel, including down blending with depleted uranium, is addressed by DOEs sodium-bonded EIS (DOE/EIS-306, 2000) and is not part of this NEPA action.
This EA conservatively assumes that a total of 5,000 kg HALEU would be processed annually. Approximately 4 MT HALEU feedstock is available from historical and ongoing EMT processing of EBR-II driver fuel. HALEU fuel fabrication would be limited by the EMT processing rate. INL produces about 0.3 MT HALEU annually through the EMT process, with planning underway to potentially increase the production rate to meet programmatic needs. The conservative assumptions of an annual HALEU fuel production of up to 5 MTHM/yr used in the EA provides a conservative estimation of annual airborne releases and potential accidents.
- 11. From a practical standpoint, the environmental impacts are expected to be essentially the same for producing either metallic or ceramic fuel. For purposes of determining impacts for the EA, production of ceramic fuel results in higher releases for some radionuclides and thus results in greater impacts. This is because the prescribed methodology for determining emissions is based on temperature and the process to create ceramic fuel would involve heating the material to a higher temperature. If the temperature exceeds the melting point or boiling point of a specific radionuclide, the estimated emission rate for that radionuclide increases. Thus for the EA, calculated emissions were based on the highest temperature expected. Practically speaking, radionuclides that become liquids or gases during the heating process would likely be converted back to a solid before reaching the HEPA filters, and thus the emissions would be less than those assumed in the EA.
- 12. Approximately 10 MT of HALEU fuel at a U-235 enrichment level of 19.75% is anticipated to be produced as part of the proposed action. DOE has made no decision on the specific use of the fuel. The fuel could be used in advanced reactor design or for the purpose of research and development. DOE will work with other Federal agencies and commercial vendors to determine use of HALEU fuel. Any reactors that use the HALEU fuel addressed in this EA will require their own NEPA review which would include disposition of spent nuclear fuel and other waste.
- 13. In its management of radioactive waste, DOE follows applicable radioactive waste management statutes, including the Land Withdrawal Act. For purposes of this analysis, it is assumed that the majority of materials comes from the processing of EBR-II spent fuel. EBR-II missions involved defense-related activities.
Therefore, the transuranic (TRU) waste generated from production of HALEU fuel would be defense-related and can be disposed at the Waste Isolation Pilot Plant (WIPP).TRU waste that is sent to the Waste Isolation Pilot Plant (WIPP) must meet rigorous Waste Acceptance Criteria, which includes among other things a defense waste determination. DOE takes actions that are practical to segregate and keep separate defense origin material from non-defense origin material. However, due to the potential for cross contamination, DOE cannot eliminate the generation and transportation of TRU wastes to WIPP from consideration in the EA. Clarification on the defense-related origin of the HALEU fuel was added to Section 4.1.2.2 (page 19).
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
47
- 14. Consistent with information given in recent EAs, cumulative impacts presented in Table 8 of the EA include all potential doses from current operations (including Idaho Cleanup Project operations), reasonably foreseeable actions and the proposed action. RH-LLW facility and TREAT are operating, the naval reactors facility recapitalization is under construction, and we removed the DOE Idaho Spent Fuel Facility (NRC 2004) from the table because the project is unlikely to happen. The other projects are expected in the future. We updated the references in Table 8 and Section 7 of the EA.
- 15. The proposed actions fits within DOEs mission to advance nuclear power. Consistent with DOEs mission, Congress directed the Department to work with commercial vendors to demonstrate a micro-reactor as described in The National Defense Authorization Bill Section 327.
SEC. 327. REPORT ON PILOT PROGRAM FOR MICRO-REACTORS.
(a) Report Required.Not later than 12 months after the date of enactment of this Act, the Secretary shall develop and submit to the Committee on Armed Services and the Committee on Energy and Commerce in the House of Representatives and the Committee on Armed Services and the Committee on Energy and Natural Resources in the Senate a report describing the requirements for, and components of, a pilot program to provide resilience for critical national security infrastructure at Department of Defense facilities with high energy intensity and currently expensive utility rates and Department of Energy facilities by contracting with a commercial entity to site, construct, and operate at least one licensed micro-reactor at a facility identified under the report by December 31, 2027.
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
48 Chuck Broscious, President, Environmental Defense Institute Comment(s): 16 - 24 16
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
49 17 18
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
50 19 20 21
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
51 Response(s) 16 - 24: Mr. Broscious, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
- 16. The proposed action in this EA is to use uranium product material resulting from the EMT process. Information regarding sodium-bonded spent nuclear fuel and the waste generated from the EMT process was addressed in the Final Environmental Impact Statement for the Treatment and Management of Sodium-Bonded Spent Nuclear Fuel (DOE/EIS-0306).
- 17. DOE is not reclassifying electro processing waste as non-high-level waste. The Final Environmental Impact Statement for the Treatment and Management of Sodium-Bonded Spent Nuclear Fuel (DOE/EIS-0306, 2000) addresses the wastes and products from the EMT process. The wastes would be dispositioned as 22 23 24
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
52 addressed in the EIS. The ROD did not make a decision on the disposition or use of the HALEU product from the EMT process. This EA addresses the use of HALEU product.
- 18. Table 8 of the EA presents the cumulative impact of current INL emissions and emissions from reasonably foreseeable actions, including production of HALEU fuel. The maximum cumulative impact is less than the 10 mrem/yr regulatory limit from 40 CFR 61, Subpart H. Although the doses for each action in Table 8 are not all calculated at the current INL Site maximally exposed individual (MEI) location, Frenchman's Cabin, they are conservatively added together as if they all occur at Frenchman's cabin. If the HALEU emissions estimated in the EA were actual emissions, the INL MEI location would likely move from Frenchman's cabin to a location nearer INTEC or MFC depending on the alternative selected. However, the maximum annual dose would not be higher than the maximum dose predicted in the EA (depends on the alternative, see Table 2) plus the annual INL radiological NESHAP dose (0.008 mrem/yr in 2017, see Table 8). Finally, the dose calculations presented in the EA are compliant with 40 CFR 61, Subpart H (NESHAP) requirements. This regulation requires the model used to predict dose use a 100-year period for emission, deposition and build-up of radionuclides in soil. Because the facility is expected to operate only a few years, the 100-yr build up time is very conservative and presumes all emissions would occur for a considerably longer time.
- 19. Table 1 presents the inventory in 2,500 kg of feedstock material, the maximum amount that could be processed at a single facility in one year. The footnote in Table 1 explains that Alternative 1a would process 2,500 kg at two separate facilities at MFC for a total of 5,000 kg processed at MFC, and Alternative 1b would process 2,500 kg each at a facility at INTEC and a facility at MFC. The EA is based on use of 10 MT of HALEU feedstock at 19.75% U-235 enrichment to produce HALEU fuel. By processing 5,000 kg/yr, it would require only 2 years to produce the HALEU fuel. If the production rate is less than 5,000 kg/yr, the material processed each year would be less than analyzed in the EA and the annual impacts would be less.
- 20. See response to comment #17.
- 21. The proposed action in this EA is not reprocessing. The proposed action is using a non-waste product from the EMT process to produce nuclear fuel, as described in Section 1.1 of this EA. See also the response to comment #17.
- 22. HALEU feedstock is obtained from electrometallurgical treatment of Experimental Breeder Reactor-II (EBR-II) fuel with the intended U-235 enrichment, contaminated with about 100 ppm transuranic contaminants. Residual fission products have been removed such that the feedstock can be handled without extensive shielding (i.e., without requiring shielding walls as in hot cells, although containment of low-activity contamination would require gloveboxes). Based on the starting point (HALEU feedstock) in the production of HALEU fuel, this HALEU process by definition would not generate Greater-Than-Class C waste nor would it generate High Level Waste. DOE clarified this in Section 4.1.2.2 Waste Generation and Management. See also response to comment #21.
- 23. See response to comment #17
- 24. In accordance with the NEPA implementing regulations, a federal agency can prepare an EA at any time for a proposed action. If potential significant environmental impacts are identified, an environmental impact statement (EIS) can always be pursued. Conversely, if no significant environmental impacts are identified, the EA is the appropriate level of documentation and no further evaluation is necessary. DOE ensures the level and quality of analysis and data compiled for the EA is suitable for use in an EIS if it is decided that an EIS should be prepared. This course of action is appropriate for use when an agency has a basis for the belief that the proposal will not manifest significant environmental impacts.
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
53 Jason Charles, Self Comment(s): 25 Response(s) 25: Mr. Charles, DOE acknowledges your comment supporting the proposed action. Thank you.
Benjamin Cox, Self Comment(s): 26 Response(s) 26: Mr. Cox, DOE acknowledges your comment supporting the proposed action. Thank you.
25 26
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
54 Suketu Gandi, Self Comment(s): 27 and 28 Response(s) 27 and 28: Mr. Gandi, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
- 27. In criticality safety assessments, the uranium enrichment and material/fuel density are considered explicitly and independently of each other. Therefore, derivation of an effective uranium enrichment based on uranium density is not necessary. As discussed in the EA, engineered and administrative controls would be incorporated into the facility and process operations to prevent and mitigate worker risk associated with a criticality. Derivation of these controls would be informed directly from a criticality safety assessment for the process.
- 28. Worker and public safety are INLs highest priority and INL workers are highly trained in performing their jobs. Education and training requirements are commensurate with job functions.
27 28
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
55 Peter Hastings, Vice President, Kairos Power Comment(s): 29 Response(s) 29: Mr. Hastings, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
29
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
56
- 29. In scoping of the proposed action, DOE assumed that developers of TRISO fuel concepts would not be able to use HALEU resulting from the EMT of EBR-II driver fuel due to the presence of TRU contaminants and residual fission products that would require handling in gloveboxes. If ongoing efforts to decrease residual fission product contamination of the HALEU feedstock being conducted as part of the EMT process are successful, additional uses of the FCF HALEU product for other fuel types may be considered. Such consideration would be subject to appropriate evaluation in accordance with NEPA.
Lars Jorgensen, CEO, ThorCon US Comment(s): 30 and 31 Response(s) 30 and 31: Mr. Jorgensen, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
- 30. In scoping of the proposed action, DOE assumed that developers of molten salt reactor (MSR) concepts would not be able to use HALEU resulting from the EMT of EBR-II driver fuel due to the presence of residual fission products. If ongoing efforts to decrease TRU contaminants and residual fission product 30 31
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
57 contamination of the HALEU feedstock being conducted as part of the EMT process are successful, additional uses of the FCF HALEU product for other fuel types may be considered. Such consideration would be subject to appropriate evaluation in accordance with NEPA.
- 31. Sent copy of TEV-3537 Isotopic Characterization of HALEU from EBR-II Driver Fuel Processing.
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
58 Edwin Lyman, Senior Scientist, Union of Concerned Scientists Comment(s) 32: Mr. Lyman, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
32
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
59 Response(s) 32: Please refer to the numbered comments and corresponding numbered responses.
- 32. The commenter is correct that the expected contaminants in the FCF HALEU product would likely render the material unsuitable for use in thermal-spectrum reactors, though suitable for fast-spectrum reactors. The scope addressed by the EA purposely excludes further decontamination using aqueous methods, primarily to limit cost. So, fuel made from the material would be limited to use in fast-spectrum reactors, or other reactor systems in which the reactor performance and fuel performance are not sensitive to those contaminants. Should the Department decide later to include potential application to thermal-spectrum reactors, such consideration would be subject to appropriate evaluation in accordance with NEPA.
Bob McGarn, Self Comment(s): 33 Response(s) 33: DOE acknowledges your comment supporting the proposed action. Thank you.
33
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
60 Rich Powell, Executive Director, ClearPath and David Blee, President and CEO, U.S. Nuclear Industry Council Comment(s): 34 34
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
61 Response(s) 34: Mr. Powell, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
- 34. Conversion of U.S. Navy fuel into advanced reactor fuel is not within the scope of this EA. This EA is limited to the use of HALEU product material resulting from the electrometallurgical processing of sodium-bonded spent nuclear fuel addressed in DOEs Sodium-Bonded Environmental Impact Statement (DOE/EIS-0306, 2000) and other small quantities stored at the INL.
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
62 Peter Rickards, Self Comment(s) 35 - 43: Mr. Rickards, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
35 38 36 39 41 40 37
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
63 43 42
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
64 Response(s) 35 - 43: Please refer to the numbered comments and corresponding numbered responses.
- 35. See response to comment #24
- 36. Pu-238 has not been detected using approved analytical chemistry methods and calculation to determine chemical and isotopic composition from six casting batches of HALEU feedstock material, comprising roughly 202 kg of uranium. The detection levels presented in the analytical results are given in weight percent (wt. %), ppm, parts per billion (ppb), and parts per trillion (ppt). Production of Pu-238 involves nuclear irradiation of Np-237, which is not within the scope of this project. Pu-238 is not expected as a product or by-product contaminant for High-Assay Low-Enriched Uranium (HALEU) fuel development and is therefore not addressed in the subject document nor supporting dose calculation documents.
- 37. See response to comment #24
- 38. DOE takes its responsibility for the safety and health of the workers and the public seriously. Accidental nuclear criticality is recognized as a potential hazard; however, a criticality event is extremely unlikely because a large number of independent failures would have to happen before an accidental criticality
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
65 could occur. DOE has multiple engineered and administrative controls in place to prevent these failures. In the unlikely event of an accidental criticality, the potential dose to the public is bounded by the accident analysis in the EA. Intentional destructive acts are discussed in the EA (see Section 4.1.5).
Accidental nuclear criticality is recognized as a hazard primarily from direct radiation exposure to workers within the affected area. Through a combination of engineered and administrative controls, potential dose to the public is bounded by the accident analysis in the EA.
In criticality safety assessments, the uranium enrichment and material/fuel density are considered explicitly and independently of each other. Therefore, derivation of an effective uranium enrichment based on uranium density is not necessary. As discussed in the EA, engineered and administrative controls would be incorporated into the facility and process operations to prevent and mitigate worker risk associated with a criticality. Derivation of these controls would be informed directly from a criticality safety assessment for the process.
- 39. The worker dose referred to as 8.81 rem is actually a conservative estimate of committed effective dose to the worker over 50 years - per minute of exposure to the accident conditions. Worker training dictates the reasonable response that in a catastrophic accident, the affected area is immediately evacuated, which is the basis for the assumption as stated in ECAR-4310, to the effect that a worker would evacuate the affected area in less than one minute following an accident. The 8.81 rem committed dose per minute of exposure equates to approximately 176 millirem per year averaged over the 50 years. This dose rate is less than that associated with natural terrestrial and cosmic radiation exposure rates encountered in everyday living. Likewise, the 997 mrem accident-induced committed dose referred to for a collocated worker at 100 meters results in approximately 20 mrem per year average over 50 years, which is well below radiation dose from natural sources over the same time. By comparison, 10 CFR Part 20 limits annual whole body total effective dose equivalent to 5,000 mrem (5 rem) whole body radiation exposure for radiation workers.
- 40. The scope of this EA does not include Pu-238 production (see response to comment #34). The potential consequences of Pu-238 production noted in the comment were addressed previously approved in DOE/EIS-0310.
- 41. The phenomena discussed in the referenced documents are specifically applicable to Pu-238 due primarily to high decay heat and radiologic decay mode of that isotope. The documents cited address work at Savannah River in the 1970s and 1980s in production of and subsequent clean up from Pu-238 production.
The work scope included in this EA does not involve Pu-238 and the comment has no relevant context to HALEU fuel development. Pu-238 has not been detected or derived by calculation to be present in materials to be used in HALEU fuel development and has therefore not been addressed nor analyzed in this EA. The analyses presented in the EA represent maximum hypothetical doses and do not credit administrative and engineering controls, including HEPA filtration. Nevertheless, HEPA filtration is an effective means to control release of particulate radionuclides and will continue to be used as an engineering control to protect workers and the public.
- 42. DOE has made no decision on the specific use of the fuel. The fuel could be used in advanced reactor design or for the purpose of research and development. DOE will work with other Federal agencies and commercial vendors to determine use of HALEU fuel. Any reactors that use the HALEU fuel addressed in this EA will require their own NEPA review which would include disposition of spent nuclear fuel and other waste.
- 43. See Comment/Response #39
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
66 Ann Rydalch, Self Comment(s) 44:
Response(s) 44: Ms. Rydalch, DOE acknowledges your comment supporting the proposed action. Thank you.
44
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
67 Abhijit Sengupta, Self Comment(s) 45 - 49: Mr. Sengupta, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
Response(s) 45 - 49: Mr. Sengupta, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
- 45. The definition of dose has been changed to clarify that dose is due to external and internal radiation.
- 46. While the suggested text is a regulatory limit for the TEDE, it is not a description of the term. Regulatory limits are discussed in the document.
- 47. The definition is correct and further clarification is deemed not necessary.
- 48. The definition is correct and further clarification is deemed not necessary.
- 49. Appropriate references (e.g., CFRs) were added to the EA where missing.
45 46 47 48 49
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
68 Tami Thatcher, Self Comment(s) 50 - 63:
50 51
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
69 52
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
70 53
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
71 54
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
72
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
73
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
74 56 55
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
75 57 59 58
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
76 59
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
77
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
78
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
79 60 62 61
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
80 Response(s) 50 - 63: Ms. Thatcher, thank you for your comments. Please refer to the numbered comments and corresponding numbered responses.
- 50. The Final Environmental Impact Statement for the Treatment and Management of Sodium-Bonded Spent Nuclear Fuel (DOE/EIS-0306, 2000) discussed the EMT process, but the ROD did not make a decision on the disposition or use of the HALEU product from the EMT process. This EA addresses the HALEU product as HALEU feedstock in production of HALEU fuel.
In accordance with the NEPA implementing regulations, a federal agency can prepare an EA at any time for a proposed action. If potential significant environmental impacts are identified, an EIS can always be pursued. Conversely, if no significant environmental impacts are identified, the EA is the appropriate level of documentation and no further evaluation is necessary. DOE ensures the level and quality of analysis and data compiled for the EA is suitable for use in an EIS if it is decided that an EIS should be prepared. This course of action is appropriate for use when an agency has a basis for the belief that the proposal will not manifest significant environmental impacts.
- 51. DOE added conversions for pounds (lb) to kilograms (kg) and kg to lb. and noted that 1000 kg equals a MT in the EA sections for helpful information for readers.
- 52. Treatment of sodium-bonded spent nuclear fuel is ongoing and addressed in the Final Environmental Impact Statement for the Treatment and Management of Sodium-Bonded Spent Nuclear Fuel (DOE/EIS-0306). The proposed action in this EA intends to use the HALEU product from the EMT process addressed in EIS-0306. Idaho Settlement Agreement milestones and management of high-level waste is not part of the scope and analysis of this EA.
63
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
81
- 53. DOE takes its responsibility for the safety and health of the workers and the public seriously. 10 CFR 830 governs the conduct of DOE contractors, DOE personnel, and other persons conducting activities that affect, or may affect, the safety of DOE nuclear facilities, and DOE holds all personnel acting on its behalf to comply with 10 CFR 830. When an incident arises of failure to follow the safety requirements, DOE takes action to correct the failure and prevent future recurrence, including causal analysis and extent of conditions review.
- 54. DOE takes its responsibility for the safety and health of the workers seriously. Radiation worker doses at INL are maintained well below limits as required by regulations - 5 rem (5,000 mrem) whole body deep-dose equivalent per year (10 CFR Part 20). The regulatory limit is based on recommendations provided by the International Commission on Radiation Protection publications and other independent and peer reviewed documents and in consideration of the latest available scientific information of the biology and physics of radiation exposure. Furthermore, in accordance with INLs as low as reasonably achievable (ALARA) policy, current administrative control limits (ACL) restrict worker whole body dose to less than 20% of the regulatory limit.
- 55. Evaluating nuclear energys place in the energy market is out of scope of this effort. This EA does not address the economics or affordability of nuclear power, leaving that decision to those proposing to use the HALEU fuel.
- 56. See response to comment #22.
- 57. All annual INL radionuclide NESHAP reports are available to the public as well as INL Annual Site Environmental Reports where emissions are presented by radionuclide and facility. Each regulated INL Site facility determines airborne effluent concentrations from its regulated emission sources as required under state and federal regulations. Regarding the assertion in the comment that the "...estimated dose from radiological emissions in Table 2 demonstrate the inaccuracy and underrepresentation of ongoing radiological air emissions as reported at Frenchman's Cabin..." in annual NESHAP reporting, we submit that the opposite is truethat is, the calculated or estimated emissions are greater than measured emissions. The emissions in Table 2 are based on the methodology in 40 CFR 61, Appendix D with EPA approved allowances to account for heating. In the absence of emission measurements, this methodology (or similar) must be used because it results in more conservative emission estimates. In addition, annual INL radiological NESHAP dose calculations and the dose calculations presented in the EA for the HALEU facility are compliant with 40 CFR 61, Subpart H (NESHAP) requirements. This regulation requires the model used to predict dose use a 100-year period for emission, deposition and build-up of radionuclides in soil. It is unlikely that current radiological emission sources at the INL will operate for 100 years, especially the HALEU production facilities which is expected to operate only a few years. The INL Site 2017 NESHAP report DOE/ID-11441 (DOE-ID 2018) was added to the reference list.
- 58. Commenter surmises that radiological emissions in Table 2 demonstrate the inaccuracy and underrepresentation of ongoing radiological air emissions as reported at Frenchmans Cabin Radiological emissions from all INL facilities are measured or calculated in accordance with 40 CFR 61 Subpart H National Emission Standards for Emissions of Radionuclides Other Than Radon from Department of Energy Facilities (Subpart H - NESHAP) requirements. Emissions from radionuclide emissions sources are required by Subpart H to be calculated in accordance 40 CFR 61 Appendix D Methods for Estimating Radionuclide Emissions or other procedure for which EPA has granted prior approval. These facilities apply the Appendix D airborne emission factors or approved alternate procedures to their respective source terms. The dose from each emission source is modeled using CAP-88 (EPA required air dispersion modeling software) to 62 off-site receptors (residence, school, business, or office). The modeled dose impact from all INL sources at each receptor is summed to determine the highest effective dose equivalent which historically has been at Frenchmans Cabin. Ambient air monitoring performed by DOEs INL Management and Operations (M&O) contractor; DOEs INL Environmental Surveillance, Education, and Research Program (ESER) contractor (independent from the M&O contractor); and the Idaho Department of Environmental Quality (DEQ) INL Oversight Program demonstrate that impacts from the INL are low and consistent with the emissions reported in annual INL radionuclide NESHAP reports. DOE contractors ambient air monitoring data are reported annually in the Annual Site
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
82 Environmental Reports which are available at the ESER programs website. DEQs INL Oversight Program Annual Reports are available at DEQs INL Oversight Monitoring Program website.
All discharges to the ATR Complex Evaporation Pond are sampled, reported, and dose modeled in accordance with the facilitys air permit and EPA requirements contained in Subpart H and Appendix D (i.e., the NESHAP annual report). This includes any incidental or accidental discharges to the evaporation pond. ATR Complex does not purposely flush radioactive resin to the evaporation pond; however, discharges of resin to the evaporation pond are not prohibited by the facilitys air permit or Subpart H.
Contamination was found outside the contamination area boundary on the berm of the Evaporation Pond fence on the berm of the pond as reported in the 2016 ASER report. In accordance with accepted practices for contaminants at these levels, a soil cap of at least 30 centimeters of soil was added over the area where the contaminants were found. The contaminants were silt-like soils that did not contain any resin. The purpose of the Evaporation Pond permit is to regulate the discharge of radionuclides to the ATR Evaporation Pond. Upon end of useful life of the ATR Evaporation Ponds, the facility would be cleaned up to regulations applicable at the time of closure.
- 59. The INL manages nine Public Water Systems at the INL Site and provides required sample results to the Idaho Department of Environmental Quality. All of these systems result in water well below those Maximum Contaminant levels identified in the Safe Drinking Water Act.
Potential doses from airborne contamination presented in the EA are based on a long-term chronic exposure scenario for a permanent resident that consumes locally produced food products including crops and vegetables grown in contaminated soil, and milk and meat products from animals that consume contaminated forage. The model used to predict dose also assumes emission, deposition and build-up of radionuclides in soil occurs over a 100-year period--
much longer than the operating period assumed in the EA. Doses based on air immersion, direct ground radiation, air inhalation and food ingestion are below all regulatory standards.
Potential impacts of groundwater contamination due to radionuclide deposition on soil and migration to the aquifer have been added to the EA. The source (soil contamination) was conservatively estimated and a screening-level model was used to simulate leaching and transport of radionuclides through the unsaturated zone and in the aquifer. Calculated doses based on maximum predicted groundwater concentrations are well below the doses from air emissions and less than all regulatory limits. DOE added a section on Groundwater Exposure Pathway to the EA (see page 17)
- 60. Regarding concerns about consequences of potential committed dose to workers, the public, and the environment, the operations proposed under the proposed action would be performed in full compliance with DOE 5400.1, General Environmental Protection Program, DOE Order 458.1, Radiation Protection of the Public and the Environment, and 10 CFR Part 835, Occupational Radiation Protection. Dose based consequences of the proposed action, as detailed in this EA, are derived from the Annals of the ICRP; Publication 103, The 2007 Recommendations of the International Commission or Radiological Protection, and in consideration of the latest available scientific information of the biology and physics of radiation exposure. The purpose of this EA is to assess the environmental impacts of the proposed action.
- 61. See response to comment #12.
- 62. Doses in the EA from air emissions are presented at locations where the maximum dose is expected to occur from HALEU production. The current (2017) annual INL NESHAP dose, presented in Table 8, is the dose to the maximally exposed individual (MEI) considering all public receptor locations outside the INL Site boundary where a person is expected to reside. The MEI dose in the NESHAP report is based on the estimated emissions from all radionuclides from all INL
Table A-2. DOEs response to comments on the draft EA sorted by commenter.
83 sources. The dose is based on a long-term chronic exposure scenario where the resident lives, works and eats locally produced food products. This dose may change from year to year, but it bounds the dose at any other public receptor location outside the INL for each year. While the INL NESHAP report includes the dose by facility, Annual Site Environmental Reports (ASERs) present the dose at the MEI location by radionuclide and facility.
- 63. See response to comment #24 Noy Xayavong, Self Comment(s) 64:
Response(s) 64: Mr. Xayavong, DOE acknowledges your comment supporting the proposed action. Thank you.
64