MIRION T E CHNOLOG I E S April 19, 2019 ZION SOLUTIONS Attn: Marvin Manninen 101 Shiloh Blvd ZION, IL 60099 To whom it may concern Dosimetry Services nivision 2652 Mc.Gaw Avenue Irvine, CA 92614 Toll Free* (800) 251-333' Tel. (849) 419-*I00C Fax.,(949) 296-114, www.mirion.con Enclosed is your environmental report for the locations, and wear periods listed below reported in units of,mR:

Account 92255 Location Wear Date 00000ENV 1/1/2019 As a reminder, no background has been applied. Only, fade and reader corrections.have been applied. The Analysis and Reporting of these results are _perfonnt:d in accordance with the Mirion Technologit!s (ODS) Inc. Quality Assurance Manual and Standard Operating Procedure T-550 Production of Environmental Reports. If you have any questions please contact me at (949) 419-1000, ext. 2083.

~~

Tam Hang Vo r Team Leader-Dose Analysis Global Dm:imetry Solutions, Inc.

0242214 REP411Cl_()

MIRION T E C HNO L OGIES Dos!mefry Services Dfvis1or, 2652 McGaw Avenue Irvine, CA 92614 Global Dosimetry Solutions Environmental Report 92255 ZION SOLUTIONS

~*-**--*-*----- *-------------*-*****.- *- - --* -

.OOOOOENV _______.. ---*- *-............ -*--- - ---- --... - ----*--

d 1/1/2019 ----------------*-*-----** -*--*---------

0242214 i_

' -- ---*-----*--'-,_ ~

  • ~*~"

"~~

  • L.
    • . - I*,,,,;_lf.\\1;"2'-

,_ =Element 2,Els~~ El:ement4 ~rmntAvg CONTROL 20 19 20 20

  • ---- I Z-0~1S~AIR ss I

I 1

18 18 18 18

- _ -2. J Z-01-2 S.AIR SS --

17 17 17 17 3

Z-02-1 W.AIR SS 16 17 17 17

- ~ - **---

  • 4 Z-02-2 W.AIR SS
  • 11 I 11 17 17 I ~-~= 5 -~= Z-03-1 Nl>JR ss -~~:=~- _

___ 11_). _

_ 18 17 17 6 l Z-03-2 N.AIR ss 17 17 17 17

---** ---~-

~

  • - -.. ---~---- - --- -- ***--** * *-

7 Z-101-1 0.5MI A 17 17 17 17 9 ___ J Z-102-1 0.5MI B 17 17 17

".7 10 Z-102-2 0.5MI B 17 18 18 18 11 Z-103-1 0.5MI C 17 18 16 17 12 Z-103-2 0.SMI C 18 17 17 17

~-104-1 0.5MI D 16 17 15 16 1?_ L11

_J 14 Z-104-2 0.5MI D 16 17 15 Z-105-1 0.5MI E 17 16 16 16

-~~----

16 Z-105-2 0.5MI E 17 17 17 17

  • 17 Z-106-1 0.5MI F 18 17 18 17 18 Z-106-2 0.5MI E l

11. ~a 18 17

-~- --~---- ------ *-* --*- ---- *--**.. - **---***--

  • - No control exposures hava been subtracted, and only ~lement, reader and fade corrections ha*:e been made.

11 Free: {800) 251-333' TeL (849) 419-100(

Fax. (949) 296-114t www.mirion.ro1r Page 1 of6 REP412il_0

MIR ON Dosimetry ~Gt vices Div/don 2652 IV1cGa*:, tw-=nu, Irvine. CA 92614 E CH N O L OGI ES Global Dosimetry Solutions Environmental Report

__ 9_2_2~55 ___

Z_IO_N_ SOLUTIONS _____ _

1 OOOOOENV __ ---** _....... _

~

-~ - -

sm~n1 a Etement 4 Eh"Jl

'f1I.

16 17

  • 1*a 18 18 18 19 I 19 19 19 20 19 19 19 18.

18 37 Z-13-1 CONTROL 22 22 L 38 Z-13-2 CONTROL 20 21

  • - No control exposures have-been subtracted, and 011ly element, readec and fadil corrections have been made.

Page 2 of 6 REP4129_0 251-333 *

(940) *,:19-100(

Fax. (~:~9) 29G-114L W\\'N. rnirion.con

MIRION Dosin1etry Services Division 2652 McGaw Avenue Tell (800) 251-333*

T E C H N OLO GI E S Irvine, CA 92614 Global Dosimetry Solutions Environmental Report

__ OOOOOENV

_ 1/1/2019 0242214

  • : ~;:;:~W:~o:-,- --+/---:i---: - :

~:

--:* 45 Z-122-2 SSW SWYD 62 63 62 62

  • ------ -----*-*- - -------1---------------- _

.*; 45*" *-

Z-123-*I SSE SWYO 40 42 43 42


~-----*-* ----**-- - *---***-- - -- -

l -- -~!-* __ z_.;1~2-~-_2_s_s_E_s_wv_o ___ --i1---3_s _

_____ 4_1_--tl!--__ 44 __

11- --

, 4 __ 1_-1 48 Z-124-1 PROP BOYL 19 18

  • 18 18

. 49 Z-124-2 PROP B()Y L 18 18 18 18


~--

. 50 Z-125-1 PROP BOY K

. 19 19 18 19 51 Z-125-2 PROP BOY K 17 16 17 17 ll-'---52_---e-z-~_20_9_-1_!>_M_I_._ K_____ _ _ _____ _j *

- 18_- -__

1_9 _ _.__1_9 ___

1_9_-11

--~--_53 _ __ z_-~~~:~~~11. K 18 j_ __

19 ____

1_9 ____

1_9 _

54 Z-2.11-1 SMI. L 21 22 22 22 55 Z-211-2 5MI. L 21 21 20 21 I 56 Z-212-1 5MI. M 22 22 23 22 57 Z-212-2 5MI. M 22 22 * -

22 22 58 Z-213-1 5ML N 23 25 25 24 1!----------------------**l!---*- ---

59 Z-213-2 5ML N 22 22 23 22

  • - No control exposures have been subtracted, and only element, reade, and fade corrections have been made.

Page 3 of6 REP41.;!9_0 l!:!49) 4*19-'1C*CC Fax,(949) 29G-114~

1."','W mirion.con

MIRION TEC HN OLOG I ES Do~-.imett'y Services Division 2652 McGaw Avenue Irvine. CA 92614 Tc..,;I FrEe (3(i0J 751--333*

{~':4D) LI i 9-100(

rax _r,949) 296-114*

ww*N. mirion.con Global Dosimetry Solutions Environmental Report

. 92255 ZION SOLUTIONS

'<I

, 00000(;:NV

-- 1/1/2019 _. -- -- --

0242214

-~--- -------- --... --------*-----ii

-* ---~*. l*i

  • t**

~.

~

.... -* ~..

.er.;,


:*-=,- -*--*~-

~-...,._... fJ::-* ~';-

)

~~nv.f~ ~G'l'M~f3 'Ciaifsp~; EJrnnt Av.s.

  • l

-~-.. ;;

60 Z-214-1 5MI. P 22 22 21 21

--*-**---~------- -----

i-~,-

Z-214-2 5MI. P 22 23*

22 22 Z-21"5-1 5MI. Q 22 I

22

  • e2 -

21 22 r *-sa'.

Z-215-2 5MI. Q 23 21 21 22

~

Z-216-1 5MI. R 20 20 19 20

..:___65 -- J Z-216--2 5Mi. R 20 19 20 20

- -~-

66 NESWYD 1 17 17 16 17 67

'NESWYD-2 15 17 16 16 1a __ I 68

-SESWYD-1 18 17 18 L __

~9

~* -*- *- **** - - ~- ------

SESWYD-2 18 18 18 18 70 NE ISFSl-1 86 88 90 88 71 NE ISFSl-2 86 88 87 87 72 E ISFSl-1 25 25 26 25 73 E ISFSl-2 26 25 26 26 76 S ISFSl-1 44 42 42 43 77 S ISFSl-2 43 43 41 42 78 W ISF'Sl-1 70 68 72 70 WISFSl-2 64 67 67

'-~

      • --- -****** -**-~

J__ 66_ __ J

.. _ No control exposures have been subtracted, and only element, reader and fade corrections have been made Page 4 of6 REP4129_0

MIRION EC HNOLOGI E S Dosimetry Services Division 2652 McGaw Avenue Irvine. CA 92614 Dosimetry Solutions Environmental Report ZION SOL.UTIONS _____.. --* ______ -------- --

- --u

---* - ---- - ---------D 1/2019 _ --**---- ----.~--

42214 --------- -- *----- ----- ------ --

~~

~

~

~~;;-'~:-t~'-

  • ,~

";' r-

.. ;.Eltme~ j ~l:ftmtn 3' Ele.me.nt 4 ~ill,!ilt~vg 80 Z-13-3 CONTROL 21 21 20 21

_ _!1__1 Z-1-3-4 C~~_T_R_O_L ______ =-__

2_1 _-c--_22 ____ 2_2 _ _ _.__.~2 __

.&2 Z-13-5 CONTROL 20 20 20 20

,~Bl /~ *.Z-13..S CONTROL 21 21 2-0 21

* !84,

SPARE


~ ~ __ 19 *-,

2-1--,

-19 ___

2_0_

-:* as - : -Z1~9-1 NW SWYD 19 19 18 19 I

86 Z-129-2 NW SWYD 18 18 18 18 87 Z-130-1 W SWYD 20..

21 21 21

  • ': as:

Z-130-2 W SWYD 21 21

  • *20.

. 21

--~-----t-------- -

89 Z-131-1 SW SWYD 33 32 33 33 90

. I Z-131~2 SW SWYO 34 33 32 33.

1------------------1,-------1--------------ll 91 Z-109-1.5MI H 18 18 17 18

- --+------!f-------- ---+-----

. ___ 9_3 ____ ~-109-2.sM1 H I

1a.. 1 --

1a _____ 1_a ____ 1_a __ -

93 SPARE

_________ 1 __

20_

20 19 ____ 2~

98 SPARE 19 19.

19 ~

~ ~;- j ~::::-~--~-:--~-:-~--~

-~~---_-_-_-_-___ -_

-_ -2_2:~-=----i--:: ____

----~

r 101 _lz-14.3 CON_T_RO_L _

_________ 2_4_~_2_3 _____ 2_2 ______

23_~

    • No control exposures have been !IUbtracted, and only element, read&r,an-:t fade corre_ctlons have been rnade.

I Free: {1300) 251-333 Tel. (849J -tHl--100t Fax. (949) 296-114,,

v,/ww.mirion con Page5of6 REP.(129_0

MIRION T ECH NO L OGIES Dosimelly SHvices Division 2652 l\\.1cGaw Avem*e-lrvine. CA 92614 Global Dosimetry Solutions Environmental Report

, 1/1/2019

~~- -------- ---------*---~- -------

.9.f422=-1"'--4'------

102 Z-14-4 CONTROL 21 21 22 22 103 Z-14,5 CONTROL 22 23 22 22

  • . No control exposures have been subtracted, and only element. reader and fade corrections have been made.

I I t rG00)251-333*

°icl. (949)419~100l Fax. (949)290-114*

viw*.-., mtlion con Page6 of6 RE!'41Ze_o

MIRION

, T E CH N OLO G I ES July 29, 2019 ZION SOLUTIONS Attn: MARVIN MA.._'NNINEN 101 SH1LOH BLVD ZION, IL 60099

Dear Marvin,

Des frne{ry Services Division 2652 McGaw Av nt1e Irvine CA 92614 Enclosed is your environmental report for the locations, and wear periods listed below reported in units of mR:

Account 92255 Location Wear Date 00000ENV 4/1/2019 As a remind':!r, no backgr,;,und has been applied. Only, fade and reader corrections have bee.n applied. The Analysis and Reporting of these results are perfonned in accordance with the Mirion Technologies (GOS) Inc. Quality Assurance Manual and Standard Operating Procedure T-550 Production of Environmental Reports. If you have any questions please contact me at (949) 419-1000, ext. 2083.

Team Leader -Dose Analysis Global Dosimetry Solutions, Inc.

02431~

REP4110_0

\\948),:SG-1G0 t94S) 296-114

  • .:*.vw.mirion.ccr

MIRION TE C HN OLO GIE S DoE-[metry Ser !ices Dtvidcn 2652 McGcw Av<::rwe CA 92614 Global Dosimetry Solutions Environmental Report

,Account_ *. __

  • 92255 **--- ZION SOLUTIONS _________________ _

Toll 1-P_~--'----I_Q00QQ~N_Y.._ _____., __ __ *-**--*-------*-----------*-

Monltoi'hyJPerlod 4/1/2019 --------"--

Process_ --____ *__ _Q_24~192 __________________________

w.......... --------**-*-----------

  • -All applicable corrections have been applied.

Page 1 of 7 REP4129_0

MIRION T EC H N OLOG I ES f;csimefry S~rvices Dtvision 2652 !vit.:Gc1w Avt":nua Irvine. CA 92614 Global Dosimetry Solutions Environmental Report Account --._

. 92255 --- ZION_ SOLUTIONS ----*-**------*------- -*-*-

Location O0000ENV


1 M_Q~l~tll'.19 J'!~rJ<XJ. _4/1 /2019 Process.

0243192

~ *


1 Badge -. '. *'/'.,.

. El(posure mR*

  • Name

-Number;: **:'. *: * :* -::

EJement2 Element3 Efement4 ElmntAvg 17 2-106-*1 0.5MI F 21 21 21 21 F~Ft;~~R:~i~ --~-=R=-=~: _J~_:-~i L

20 __..l_z-101-2 o.sM1_G ___.. ***--*** **- --' __ 2o ___ l __ 20 ______ 20 _____ l ____ 20 ________ _

I

_ 21 ____ Z-108-1 0.5MI GH -


**** ****-* **-** 21 _J ___

21 -- *-

22 -- _I __.. 21 _____ I I_ ____

22 -* *. _Z-108-2 0.5MI GH - - --*-*- ***-**

____ 21 ___ 1 ____ 22 __. -- 22

.l ~§~

I I __ 23

_z-110-1 o.sMI K ______ ____________ 22 __ J+/-+/-z2 23 ___ l __ __ 22 ___ _

I....

2_~ ____ _ -~-110-2 ~:~_rvll ~ -- __..... __________ --~

24

_ }3 __,_

23 L_ 25 _J Z-11_1-1 __ 0.5MI L


~2 ____ J_ -*- 21___

          • - 21 *---** _____ 22 L

___ 26 --

_Z-111_-2 0.5MI L ---****-**-*--*-*--*- 23 _ I 24

-- --~


24 ____ J 1

27 ____

  • Z-112-1 2MI M --*-------***-------,-}1 _____ L __ 22 --- ---* _22 I 21 _I L_ 28

-- _Z-112-2 2MI M _________ -- -*-----**-- ___ 21 ____ ~

_21 ___ _1 ____ 21 ___ _J L

__ 29 _

Z-113-1 2MI _N - - ------***-**-* - - -19 L_ 19

. *---20 __.. L_.... 19 _ ]

I_ __ 30 ____ Z-113-2 2MI_N **- ****---**** *-**--*_1 ___ 20 ___ J __ ____ 20__ _

20 I _

20 __ __ J L-3~----- Z-114-1 2MI p

---. **--* ~9 _ _ J ____

~ _..

21 I 20 L_ ___

32 ----- _ Z-114-2 2MI P ____ _ *- -*-*-* *-****** --*-* 21 _____ L __ 21 --- *----21 ___ _l __ 21 __ _

L_ 33 - -

Z-115-1_ 0.5MI _O ______________

_ -- 20 _J 19 --

20 ___ L _ 1_9 _--t L. --~4 **-*** Z-~~~*:_?_~-?~'-~ ---**-* -**** -**--**

20 __ _I _ _?_~--- *-*- -~1 _____ __ J _

___ __ 2-C?_

  • -All applicable corrections have been applied.

Page 2 of7 REP4129_0 Fzx.

  • *<-.~':1.1 n:rio n.cot

MIRION TEC H N OLOG IE S Uos ti'l1Glty Services Divisio;~

2Gf"-2 lv1cGaw Aven1.;e CA 92614 Global Dosimetry Solutions Environmental Report

_Acco~ * *. _* __ *. _92255 ____ ZION SOLUTIONS _

L~~tion ~..:..:_.P.OOOOEf'iV ________ __ ______________________ _

M.9flt~r'-'11l.P.!dQ9 :4=1_1:.:12-=.0~1~9 __________ _______ _

Proce&s

  • . 0243192

...: ---**"*-~-*- ----------------------

\\

"-All applicable corractlons have been applied.

Page3 of 7 REP-4129_0 (94;1) 296-,14 1-.v*..v miricn co,

MIRION I

Tdi TE CHNOLOG I ES Irvine. CA Global Dosimetry Solutions Environmental Report Account,.*.. _ _ :. -_ 92255 -- _ **-* ZION SOLUTIONS ------ -* -* -- _,...... -- **- -------........

_Locatlon -. *-~ -~-.9J~Q9_0!;~Y.. ______ _____________ __ _ ____ _

-~lwr:lngj~,rJo_c;t ~/.117_0_1~9~---*-- ---______________ _

P~ocess _ _,. ~ *. _ 024319,_--=2'------ -------------*---*-

  • -All applicable corrections have been applied.

Page4 of 7 REP-4129_0

MIRION

' T E C HNOLO G I ES It vine, CA 9261 1+

Global Dosimetry Solutions Environmental Report Ac!tQunt **....._ _ ~* 92255. ___.ZION SOLUTIONS ___. ----***--*---***--*---*-----**.. _ ***----

Location. '

OOOOOENV

.MonitortnJi.Period 4/1/2019 _____.

  • -All applicable corrections have been applied.

Page 5 of 7 REP4129_0 r:ax

":-,,:vw.mir!on c.c,

MIRION

' T E CH N OLOG I ES

[J.osiinctry Services !)tvl:=fon 2652 McGaw Avenue Irvine. CA 92614 Global Dosimetry Solutions Environmental Report Account.. ___...:_*. 92255

______ ZION SOLUTIONS LoP,l.ti.9n *-.... :*..

OOOOOENV I-=-*

  • -----.--"~.... -

~-----*- --- *-

Mqnttoring 'Peno4 4/1/2019 ---~---------- _______ -*--

p~q~s -_,: __ _._* __ 0243192 _ _____________

  • -All applicabl_e corrections have been applied.

Page 6 of 7 REP4129_0 Ti?I.

MIRION T EC H N OLO G I ES Global Dosimetry Solutions Environmental Report

_Ac~O\\lllt...,:: ~

_92255 ___ _ ZION SOLUTIONS b.q_CM!Cin'.:.. __ *. OOQQP_!;_~'l_ ___

_Moriitorin~_Period 4/1/2019 _______ ____. _______________. _____________ _

Process : *._:. *'

  • 0243192
-,*;~""***~-I...,~.......,...,.., --*-*-*-*'-"-'0----- ------

-All applicable corrections have been applied.

Page 7 of 7


~-----------

REP4129_0

\\~;.;~!) 2E:6-180

,94£':) 2G6-, l<i

  • *.v,, 11,1ric*n cc1

MIRION TECH NOLOG I ES October 25, 2019 ZION SOLUTIONS Attn: MARVIN MANNINEN 101 SHILOH BLVD ZION, IL 60099

Dear Marvin,

Enclosed is your environmental report for the locations, and wear periods listed below reported in units of mR:

Account 92255 Location Wear Date 00000ENV 7/1/2019 AB a reminder, no background has been applied. Only, fade and reader corrections have been applied. The Analysis and Reporting of these results are performed in accordance with the Mirion Technologies (GDS) Inc. Quality Assurance Manual and Stfmdard Operating Procedure T-550 Production of Environmental Reports. If you have any questions please contact ine at (949) 419-1000, ext. 2083.

Sincerely, ~

T:Jo J Dose Analysis Team Global Dosimetry Solutions, Inc.

0244049 REP4110_0

e.

MIRION TECH N OLOG I ES Global Dosimetry Solutions Environmental Report Ac00unt,. *.. *.... 92255_,

ZION SOLUTIONS

~

- --~~~~~---------------

  • ocat(on **J-,.*::;:~:.;...:.; _Q_QQOO~Y--------------------------1 Mt.llJ~ir.i~. Lf1/4Q_1~-------------------*--

-~~-._~---~i: ~: Q?14~0-'-4,~C:...------------ -------- --

. -: :~:.. ::t:: _: ;=:. "~ : ~. *..

  • -All applicable corrections have been applied.

Page 1 of 6 REP4129_0

MIRION ECH N OLOG I E S Global Dosimetry Solutions Environmental Report

.:.~~*:.~....... -.

92255 ZION S9~L=U*T"---'-'IO~N-'-'S'---___________

.LoMtfon ? *._

.. _. OOOOOENV

M~L~~lt1s ~,r19d J.!~!2-.R.:rn _________ ____ ; -*-----------

~~-:0.. ~:-./-.9£440~_~9 ____ __________

-~ ~~./**, --:~-: :':~.:<~-,_*_*.>:.

  • -All applicable corrections have been applied.

Page 2 of 6

  • Exposu~ _mlt*.

--- -~- *-**-------

Element 2 Element 3 *e1em~nt 4 Elmnt Avg REP4129_0

MIRION T E C HN O L OG I ES Global Dosimetry Solutions Environmental Report o _nt" *: *..,.

92255 ___ ZION :,,::S=O=LU=-"T'-'-'IO=N c.:..:S~---- ----------1 IM~~_;;.,:_:*,~* _:*'.._* _JOOOOOE~'L_-------------- -----~

... to,...rf.rutfeflg_g_ Jl1l?QJS _ ________ _

-ft>~_,.,:-::_~~::*~--.9?14_Q_49 __ _________ _

\\*. ;:: *;.:-* ~

~.,,.'".

t *

  • : i' *
  • -All applicable corrections liave beer> applied.

Page 3 of6 REP129_0

MIRION T E CH N OLOG I ES Global Dosimetry Solutions Environmental Report

"-All appllcabie t:0rrections have been applied.

Page 4 of 6 REP4129_0

MIRION T E CH N OLOG IE S Global Dosimetry Solutions Environmental Report

_'_-;~ :_* ~l,._ ;

  • i:..': -~::. 92255 _ _

ZION SOLUTIONS'-------

b9.9Atl!M).*.~_:-~\\:...'.:-, :. _OQO_OJ)~N~ __ ---------*-------------*-- _____________ _________ _________ _

)19n~g__"n."*"4l"~d _1i1,2019___________ __

-Pi~i,\\,-*.~. :~:. *.:_.; 0244049 ________

. *?:;~~-~

.. : :~~-

~..

~

  • -All appllcacle -;crrections have been applied.

Page 5 of 6 REP412S_O 12

IRION T E CH N OLOG I ES Global Dosimetry Solutions Environmental Report

.. A~nt ~:.:~~;*.. 92~.§~ _____ Z!Q_N SOLUTIONS

~~~~.-~}::._;

  • _:. *. OOOOOENV ---------*-* ___ *-----**--* __ -----*-**-*-____ _

~Q~rfoar~~~ _7/j /,?Q1J. *---- --- -;-*----------*--*-------- - -*--*- ----11 LP~y;~*;,.~:~>:~:'.~;*.. _0244049 ___________

,. ~*'.

  • -All applicable corrections have been applied.

Page 6 of 6 REP4123_0

MIRION TEC HNO LOG I ES January 22, 2020 ZION SOLUTIONS Attn: MARVIN MANNINEN 101 SHILOH BLVD ZION, IL 60099

Dear Marvin,

LJosrn1&try Services-Divts1on 2652 McGaw A':<"11u..'

CA 9L614 Enclosed is your environmental report for the locations, and wear periods listed below reported in units of mR:

Account 92255 92255 Location Wear Date 000O0ENV 7/1/2019 0000OENV 10/1/2019 As a reminder, no background has been applied. Only, fade and reader corrections have been applied. The Analysis and Reporting of these results are perfonned in accordance with the Minon Technologies (GDS) Inc. Quality Assurance Manual and Standard Operating Procedure T-550 Production of Environmental Reports. If you have any questions please contact me at (949) 419-1000, ext. 2083.

~ ~

Trun Hang Vo

/

D9se Analysis Team Global Dosimetry Solutions, Inc.

Toll Free*

T.:1.

024'1762 REP4110_0

MIRION II l;*,ine T E CH N OLOG I E S Global Dosimetry Solutions Environmental Report 7/1/2019 *------*----------- -*- - -----11 t~~:;*\\;::: :::~:t:~~;~:;11-* ~02_4~4.~7~62~- --------------------

67 29 30 29 30

  • -All applicable corrections have been appli-9d.
  • +
  • Unusual element result observed.

D

  • Element damaged and cannot be evaluated.

Page 1 of 8 REP4129_0

,~.1..:g)

,P.1fi)

  • ~ -'-it n,;rien CUl

MIRION T E C HN O L OG I E S Global Dosimetry Solutions Environmental Report ZION SOLUTIONS

_____ ---=._] CONTROL 19 19 19 19 1

Z-01-1 S.AIR SS 15 16

_ ___ 15_ ~-j-J 2

Z-01-2 S.AIR SS 16 16 16 I

3.. Z-02-1 \\JV.AIR SS 15

... 16* - -

15 4 ~. [z-02~2 \\IV.AIR SS 13 14

--14 ____ J I... _5...1.~~~~:1 _t~'.~~~ $$

17 16 r

_ 16 ___ __I L 6 I Z-03-2 N.AIR ss 17 16 16.J L_-_* {~*:.:.1~--~~:{~1-o.sM*I A 15 15 I*

a _ lz-101-2 o.5Mt A 1s 15 9

) Z-102-1 0.5MI B 16 16 16 16 15 14 15 17 16 15 15 15 15 16 10 I Z-102-2 0.5MI 8 16 17 17 16 11 lz-103.10.sM1c 19 1s

---11--

--- - ----3/4-----I 1--:: I~:::~::::-~-------- ---_:_~=-~::~~~-=--=-:--~-----~-:---1 I

14 Z-104-2 0.5MI_O _ ____ _______ -*

14 L.. 15.. I Z-105-1 0.5MI E 1_6 ______ ___ ___

1_6-

--=

L __ -~-?__

Z-105-2 0.5MI E 1~---

14 1... !~-- ~6-1 0.5M~£_ ___ __ ______ ~

-17 16 _j 18 16 14 14 I

17 I

14 16 19

-~ I 1~

20 16 15 -

17 16

  • -All applicable correction;; have been applied.

-t

  • l,Jnusual element result observed.

D - Element damaged and cannot be evaluated.

Page 2 of B REP~129_0

MIRION TECH NOLO G I E S Global Dosimetry Solutions Environmental Report

  • -Ail applicable c:orreelions have been applied.

+ - Unusual elem~nt result observed.

D - Element damligfid and cannot be evaluate,!.

Page 3 of 8 REP4129_o

MIRION TECH N O L OG IES Global Dosimetry Solutions Environmental Report

"'i*w.* i*'f i,.

.)-* *... -.

. *?. *=*

tt ;::\\::\\(:/~~ii~~l~;}?~)i;~I;::

    • a,,

'*S

~*a*.

c r. **

ure m. *...

~- * *.** *

...

  • 3J:-,,..

~ '

  • ~.,

-,1,11:1.,nt;.~inint J e~nt,t. e~_At/9 38 Z-13-2 CONTROL 17 16 17 16 F

39 Z-121-1 NSWYD 15 15 15

_ 15 ___ _ J

            • -15_J 40 Z-121-2 N SWYD 15 15 15

48 __ _J

    • -*-*44__

.. z.122-1 SSW SWYD 48 47

+ ----

I._..... 4_5 _ *.. I ~~-!~2~~-~sw swvo 54 52 52 53 J

L4sJ z-123-1 SSE swvo **-*----j-35 35 40 I

~6 I

    • ----~-~-__j :2*!33-2 ~~E SVVYO 31 33 -;s-r ;;* J 48 I Z-124-1 PROP BDY L l
  • 15 I

15 15 15

. _______ J I

1a J 49 Z-124-2 PROP BDY L 16 16 16 Z-125-1 PROPBDY K 14 I -~---J 50 15 14 I

... *****-***-- ~----

51 Z-125-2 PROP BOY K 15 14 14


~-~----_J 14 I 52 Z-209-1 5MI. K 13 14 14

-~

53 Z-209-2 5MI. K 15 15 14 54 lz-211-15Mt.L 18 19 19

____ 19_-1 55 I Z-211-2 5MI. L j

16 16 18

~.!__J I Z-212-1 20 J 56 5MI. M 20 21 20 l :__~!-

20 ____..I__ - -20 ___ J Z-212-2 5MI. M 20 19

_____ I

_1_8 ____..l_ 1_a __

1_9 _____ I _ ___!_f!__j

  • -All applicable corrections have been applied.

+

  • Unusual element result obseived.

D - Element damaged aml cannot be evaluated.

Page 4 of 8 REP4129_0

MIRION tc,d T ECH N OLOG I E S Global Dosimetry Solutions Environmental Report

-* -. mR11. * :**: :---::..... _.-~,-i;. -~

.........,__.,_.,_,...-----.,.-...,,"!~.............

... *:'.:'.".';:'*:*ri:,,:~:::", *.

....nt*lf :Elitt. :*. Vlf 59 Z-213-2 SMI. N 20 21 20 20 L_~~

Z-214-1 5Mi. P 21 20 21

_ 2_1 _-;

~-
:-- ~:~;::~ :::: : ~~--

~:

--- ~~ _ __I L.. 53 *--- I Z-215-2 SMI. Q 19 J 18 1-18 I 19 I L~-~ *

  • Z-216-1 5MI. R
  • ______ 1_

15 r-.. *--1-6 15

.. _.. ---~~ -:~~]

-: :_-~{~tM?--~~-+/-~:

67 J~~~-~WYD.:_~.

_ _l __ ---~~---1.. _. __ 1_~_ _

15 15 68 I SE SWYD-1 *..

I _

16..... J

.. -* 16 _

15 16 69 SE SWYD-2 1 16 l 16 16 16 l-~~ --~

~~=~~:--~~-~~t~R:~=q~=--* ::=*i S ISFSl-1 1

41 40 41

-~1___...J 8

.. ~f ~~~1 --

I ~:

= ~: = I

  • -All applicable corrections have been applied.

+ - Unusu;1I element result obse"ied.

D - Elamant diilila~ed and cannot be evaluated.

Page 5 of 8 REP4129_0

MIRION E CH N OLOG I ES Global Dosimetry Solutions Environmental Report 88

  • Z-130-2 W SWYD 16 16 17 16
J ~:::::: :: =~

--II!-----:-:-----~: -r- ~: --1 -:: -_j 91

. J Z-109-1.5MI H 17 17 17

-**-******- ********* - **--**-- *****--****----------+-

---+-----,---+-------

17 92

  • Z-109-2.5MI H 13

.. ** 15 14 14


;1-- -

---l!----

93 SPARE 18 20 19 19 98 __.J.sPARE ------ ---~_1_a ____ 1_0 _____ 2_0 __ _!_~.-1 99 __

z_-_14_-_1_c9~_::r_RO_L ____ ___, _ _. _19 ____ 1a _____ 1_9_L 19 I

____ 1_0_0_

...... z_-_14_-_2_CO.~TR~~......... *. -*-J *---*-15._J __

16 ___ ~.~-J_._ ~~J

  • -All applicable corrections have been applied.

+

  • Unus\\;al element reault obsgrved.

D - Element damaged and cannot be evll!uated.

Page* 6 of 8

~EP4129_o

MIRI N

TE CH N OLOG I ES

  • -A!I applicable corrections have been appliE!d.

-t- - Ur.usual element result observed.

D - Element damaged and c-.annol be avaluatAd.

Page 7 of 8 RE"<112S_0 i.

l, *.,

MIRION T E CH N O L OG I E S Global Dosimetry Solutions Environmental Report ZION SOLUTIONS 617 SPARE 18 20 19 19 618 SPARE 18 19 19 18 (5'19-SPARE 19 19 19 19 p20 SP-ARE 19 20 20 20 621 **

SPARE 19 19 20 19

'-All applicable corrections have bee11 applied.

+ - Unusual element rosult observed.

D - Element damaged and cannot be evaluated.

Page a of 8 REP4129_o

MIRION TECHNOLOGIES April 24, 2020 ZION SOLUTIONS Attn: MARVIN MANNINEN 101 SHILOH BL VD ZION, IL 60099

Dear Marvin,

Dosimetry Se ices 2652 McGaw Avenue rvine CA 92614 ion Enclosed is your environmental report for the locations, and wear periods listed below reported in units of mR:

Account 92255 Location Wear Date 00000ENV 1/1/2020 As a reminder, no background has been applied. Only, fade and reader corrections have been applied. The Analysis and Reporting of these results are perfonned in accordance with the Mirian Technologies (GDS) Inc. Quality Assurance Manual and Standard Operating Procedure T-550 Production of Environmental Reports. If you have any questions please contact me at (949) 419-1000, ext. 2083.

Sincerely, r t:i,hv r/~ V&

Tam Hang Vo Dose Analysis Team Global Dosimetry Solutions, Inc.

0245586 REP4110_0 Free: (80C) 25'1-3331 Tel. (949) 296-1800 Fax. (949) 296-1144 www mirion.com

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue rvine CA 92614 Global Dosimetry Solutions Environmental Report Account

~* 92255 Location

! OOOOOENV Monitoring Pefjoq 1/1/2020 Process 0245586 CONTROL 1 I Z-01-1 S.AIR ss 3

I Z-02-1 W.AIR ss 4 I Z-02-2 W.AIR ss 5

I Z-03-1 N.AIR ss 6

Z-03-2 N.AIR SS 7

Z-101-1 0.5MI A 8

Z-101-2 0.5MI A 9

Z-102-1 0.5MI B 10 I Z-102-2 0.5MI B 11 Z-103-1 0.5MI C 12 Z-103-2 0.5MI C 13 Z-104-1 0.5MI D 14 Z-104-2 0.5MI D 15 I Z-105-1 0.5MI E 16 I Z-105-2 0.5MI E 11 lz-106-1 o.5MI F 18 I Z-106-2 0.5MI E ZION SOLUTIIONS 15 14 15 15 16 15 17 16 14 17 17 16 14 16 14 17 15 16 14 15 15 16 16 17 16 14 16 17 16 15 16 15 17 15 16 14 14 15 16 15 17 16 14 16 17 16 15 17 14 16 15 16 14 15 15 16 15 17 16 14 17 17 16 14 16 14 17 15 Toll Free (800) 251 -3331 Tei. (949) 296-1500 Fax. (949) 296-144 wvvw.mirion.com

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 1 of7 REP4129_0

MIRION TECHNOLOGIES Dosimetry Services Divis1ior.

2652 McGaw Avenue rvine CA 92614 Global Dosimetry Solutions Environmental Report

Account, 92266 Locatlon., /-~

000001:NV

. Monitoring Pertod 1/112020 Process 0245586 20 lz-101-2 o.5MI G 21 I Z-108-1 0.5MI GH 22 I Z-108-2 0.5MI GH 23 I Z-110-1 0.5MI K 24 Z-110-2 0.5MI K 25 Z-111 -1 0.5MI L 26 Z-111-2 0.5MI L 27 Z-112-1 2MI M 28 Z-112-22MIM 29 Z-113-1 2MI N 30 Z-113-2 2MI N 31 I Z-114-1 2MI P 32 Z-114-2 2MI P 33 Z-115-10.5MIQ 34 Z-115-2 0.5MI Q 37 Z-13-1 CONTROL 38 Z-13-2 CONTROL ZION SOLUTIIONS 14 17 17 19 17 19 18 18 16 13 16 14 16 16 17 15 16 14 17 17 19 18 19 19 18 15 14 16 15 16 14 16 15 16 15 17 16 18 18 19 19 18 16 14 15 15 16 16 17 16 17 14 17 17 19 18 19 19 18 15 14 16 15 16 15 17 15 17 I

I

-1 Toll Free: (800) 251-3331 Tel. (949) 296-1800 Fax. (949) 296-144 www mirion.coni

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 2 of7 REP4129_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue Irvine. CA 926 4 Global Dosimetry Solutions Environmental Report

~ccount 92255 ZION SOLUTIONS Location

. OOOOOENV Monitoring Period 1/1120-20 Proc8" 0245586 Z-121-1 N SWYD 40 lz-121-2Nswvo 44 I Z-122-1 SSW SWYD 45 I Z-122-2 SSW SWYO 46 I Z-123-1 SSE SWYO 47 Z-123-2 SSE SWYO 48 Z-124-1 PROP BOYL 49 Z-124-2 PROP BOYL 50 lz-125-1 PROP BOY K 51 Z-125-2 PROP BOY K 52 Z-209-1 5MI. K 53 Z-209-2 5MI. K 54 Z-211-1 5MI. L 55 Z-211-2 5MI. L 56 Z-212-1 5MI. M 57 Z-212-2 5MI. M 58 Z-213-1 5MI. N 59 I Z-213-2 5MI. N 14 55 57 37 38 16 16 16 15 17 15 20 17 19 21 21 I

20 15 52 53 39 38 17 16 15 15 16 15 20 18 19 21 21 20 14 54 55 40 42 16 16 16 14 16 14 19 17 20 20 21 19 14 54 55 39 39 16 16 16 15 16 15 20 18 20 21 21 20 Toll Free: (800) 251-3331 Te!. (949) 296-1800 Fax. (949) 296-1144 www.mirion.com

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 3 of7 REP4129_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue rvine CA 92614 Global Dosimetry Solutions Environmental Report 92255 2J ON SOLUrlrONS l.Qca n

00000ENV Monltori~g_e!!riod, 11112020-* ----------------------111 Process 1 0245586 Z-214-1 5MI. P 61 I Z-214-2 5MI. P 62 lz-215-1 5MI. o 63 I Z-215-2 5MI. Q 64 I Z-216-1 5MI. R 65 Z-216-2 5MI. R 66 NESWYD 1 67 NESWYD-2 68 SE SWYD-1 69 SESWYD-2 70 NE ISFSl-1 71 NE ISFSl-2 72 IE ISFSl-1 73 E ISFSl-2 76 S ISFSl-1 77 IS ISFSl-2 78 W ISFSl-1 79 W ISFSl-2 21 18 19 16 17 14 15 18 17 92 89 24 24 42 42 70 70 20 20 20 17 17 16 15 16 16 78 86 19 19 19 16 16 15 15 17 17 80 89 25 I 24 23 25 41 44 44 45 69 69 69 67 20 19 19 16 17 15 15 17 17 83 88 24 24 43 44 69 69

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 4 of7 REP4129_0 Free: (800) 251-333 Tel. (949) 296-:800 Fax. (949) 2~6-144 www.mirion.com

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue 1-vine. CA 926....

Global Dosimetry Solutions Environmental Report Account l

1 92255 Location 1:/,,:-~:;,,-

OOOOOENV

_MQnitoring Period 1/1/2020 Process 0245586 Z-13-3 CONTROL 81 I

Z-13-4 CONTROL 82 I~1~5CONTROL 83 I Z-13-6 CONTROL 84 lsPARE 85 Z129-1 NW SWYD 86 Z-129-2 NW SWYD 87 Z-130-1 W SWYD 88 Z-130-2 W SWYD 89 Z-131-1 SW SWYD 90 Z-131-2 SW SWYD 91 Z-109-1.5MI H 92 I Z-109-2.5MI H 93 SPARE 98 SPARE 99 Z-14-1 CONTROL 100 Z-14-2 CONTROL 101 lz-14-3 CONTROL ZION SOLUTION$

17 17 17 20 15 15 17 17 28 28 15 18 22 22 21 20 21 18 18 16 21 15 16 16 18 30 26 15 17 22 21 22 21 21 18 18 16 20 16 16 16 16 29 28 15 17 20 21 22 21 21 18 18 16 20 15 16 16 17 29 27 15 17 22 21 21 21 21

~

Toll Free: (800) 251-3331 Tei. (949) 295-1800 Fax. t949) 296-1144 v*,'Vl."A'.mirion.com

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 5 of7 REP41 29_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 !VlcGaw Avenue rv 1e, CA 92614 Global Dosimetry Solutions Environmental Report

.Acc9unt 92255 Location OOOOOENV

, Monltoring Period 111/2020 Process 0245586 102 Z-14-4 CONTROL 103 Z-14-5 CONTROL 602 SPARE 603 I SPARE 604 I SPARE 605 SPARE 606 SPARE 607 SPARE 608 SPARE 609 SPARE 610 SPARE 611 SPARE 612 I SPARE 613 SPARE 614 SPARE 615 SPARE 616 SPARE 617 I SPARE ZION SOlUTIONS 22 19 23 21 22 24 21 22 23 22 21 20 16 19 21 18 20 21 23 20 23 21 21 23 22 22 23 23 20 18 17 20 20 17 19 21 21 19 23 22 22 24 22 23 22 21 20 19 17 20 22 17 19 21 22 20 23 22 21 23 22 23 23 22 20 19 16 20 21 17 19 21 Toll Free: \\800) 251-3331 Te!. (949) 296-1800 Fax. (949) 296-1144 WWW I

.corn

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 6 of7 REP4129_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue

r. ine. CA 926 4 Global Dosimetry Solutions Environmental Report ZION SOLUTIONS:..__ ________ __ _

Locati

... o--=o=o=oo=E:.:...;N:,.:_V ____ _____

/1/2020 SPARE 619 I SPARE 21 20 21 21 620 I SPARE 21 20 19 20 621 I SPARE 21 20 21 20

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made, Toil Free: (800) 2:51-3331 Tel. (949) 296-1800 Fax. (949) 296-1144 www.

.com Page7of7 REP4129_0

MIRION TECHNOLOGIES October 06, 2020 ZION SOLUTIONS Attn: MARVIN MANNINEN IO 1 SHILOH BL VD ZION, IL 60099

Dear Marvin,

Dosimetry Services Division 2652 McGaw Avenue Irvine, CA 92614 Enclosed is your environmental report for the locations, and wear periods listed below reported in units of mR:

Account 92255 Location Wear Date 00000ENV 4/1/2020 As a reminder, no background has been applied. Only, fade and reader corrections have been applied. The Analysis and Reporting of these results are performed in accordance with the Mirion Technologies (GDS) Inc. Quality Assurance Manual and Standard Operating Procedure T-550 Production of Environmental Reports. If you have any questions please contact me at (949) 419-1000, ext. 2083.

Sincerely, Ta;n,rf~J/9 Tam Hang Vo Dose Analysis T earn Global Dosimetry Solutions, Inc.

0246283 REP4110_0 Toll Free. (800) 25*1-3331 Tel. (949) 296-1800 Fax. (949) 296-1144 www.mirion.corn

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue rvine, CA 926 4 Global Dosimetry Solutions Environmental Report Account.,.

92256 J.,ocatlo1_1 'i3/4 0000OENV MonJtorlng Period_ 4/1/2020 Process 0~46283 CONTROL 1

I Z-01-1 S.AIR ss 2

I Z-01-2 S.AIR ss 3

I Z-02-1 W.AIR ss 4

I Z-02-2 W.AIR ss 5

Z-03-1 N.AIR SS 6

Z-03-2 N.AIR SS 7

Z-101-1 0.5MI A 8

I Z-101-2 0.5MI A 9

Z-102-1 0.5MI B 10 Z-102-2 0.5MI B 11 Z-103-1 0.5MI C 12 I Z-103-2 0.5MI C 13 Z-104-1 0.SMI D 14 Z-104-2 0.5MI D 15 Z-105-1 0.5MI E 16 Z-105-2 0.5MI E 17 Z-106-1 0.5MI F ZION SOLUTIONS 19 19 18 19 18 18 13 16 19 20 17 16 19 20 21 18 18 18 19 17 18 18 18 14 16 17 18 15 16 21 19 20 18 16 18 19 19 20 19 19 14 16 19 18 18 17 20 19 18 20 18 18 19 18 19 18 18 14 16 18 18 17 16 20 19 19 19 17 Toll Free: (800) 251-3331 Tel. (949) 296-1800 Fax. (949) 296-1144 www.mirion.com

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 1 of7 REP4129_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue Irvine CA 92614 Global Dosimetry Solutions Environmental Report Accoul!_l 92255 Location OOOOOENV Mo11ltorlnu.._eMiPd 411/2020

~ess

0246283, Ill 19 lz-101-1 o.5MI G 20 I Z-107-2 0.5MI G 21 I Z-108-1 0.5MI GH 22 I Z-108-2 0.5MI GH 23 Z-110-1 0.5MI K 24 Z-110-2 0.5MI K 25 Z-111-1 0.5MI L 26 Z-111-2 0.SMI L 27 I Z-112-1 2MI M 28 Z-112-2 2MI M 29 Z-113-1 2MI N 30 lz-113-2 2M1 N 31 Z-114-1 2MI P 32 Z-114-2 2MI P 33 I Z-115-1 0.5MI Q 34 I Z-115-2 0.5MI Q 37 I Z-13-1 CONTROL ZION SOLUTIONS 18 21 18 17 20 21 20 20 19 20 17 9

17 18 17 19 18 18 20 16 18 18 19 19 19 17 17 15 13 16 17 17 19 18 18 20 18 19 19 19 21 21 19 19 17 18 18 17 17 19 18 18 20 17 18 19 20 20 20 18 18 16 13 17 17 17 19 18 Toll Free: (800) 2 51-3331 Te! (949) 296-1800 Fax. (949) 296-1144 WWW.

.Gorr.

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 2 of7 REP4129_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue Irvine CA 92614 Global Dosimetry Solutions Environmental Report 92255 ZIION SOLUTION~1S~-----------

--1 OOOOOENV 4/1/2020 0246283 Z-13-2 CONTROL 39 I Z-121-1 N SWYD 40 I Z-121-2 N SWYD 44 lz-122-1 ssw swvo 45 I Z-122-2 SSW SWYO 46 Z-123-1 SSE SWYO 47 Z-123-2 SSE SWYO 48 Z-124-1 PROP BOYL 49 I Z-124-2 PROP BOYL 50 Z-125-1 PROP BOY K 51 Z-125-2 PROP BOY K 52 Z-209-1 5MI. K 53 I Z-209-2 5MI. K 54 Z-211-1 5MI. L 55 Z-211-2 5MI. L 56 Z-212-1 5MI. M 57 I Z-212-2 5MI. M 58 I Z-213-1 SMI. N 17 17 59 55 32 31 16 18 18 15 17 19 20 20 20 18 19 15 15 51 51 35 32 17 17 16 19 18 20 18 19 19 19 20 16 17 53 50 44 39 18 17 18 18 18 19 19 18 18 19 21 16 16 54 52 37 34 17 18 17 17 17 19 19 19 19 19 20

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Toll Free (800) 251-3331 Tei. (949) 296-1800 Fax. (949) 296-1144 WWi.'.f.,-1r 1.com Page 3 of7 REP4129_0

MIRION T E CHNOLOGI E S Dosimetry Services Division 2652 McGaw Avenue Irvine CA 92614 Global Dosimetry Solutions Environmental Report Account 92255 Location "

OOOOOENV Monitoring Period 411/2020

,..erocess 60 61 62 63 64 65 66 67 68 69 70 71 72 73 76 77 78 0246283 I Z-214-1 5MI. P I Z-214-2 5MI. P I Z-215-1 5MI. Q I Z-215-2 5MI. Q Z-216-1 5MI. R Z-216-2 5MI. R NE SWYD 1 NE SWYD-2 SE SWYD-1 SESWYD-2 NE ISFSl-1 I NE ISFSl-2 IE ISFSl-1 IE ISFSl-2 S ISFSl-1 S ISFSl-2 W ISFSl-1 ZION SOLUTIONS 19 19 21 21 19 19 15 13 17 18 79 77 24 23 34 41 67 20 19 19 18 17 19 14 13 17 15 76 77 21 22 33 38 59 20 18 20 21 19 19 15 14 17 18 84 82 23 23 36 40 61 19 19 20 20 18 19 15 13 17 17 80 79 23 23 34 39 63 Toll Free (800) 251-3331 Tel (949) 296-800 Fax. (949) 296-1144 www.

.corn

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 4 of7 REP41 29_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue rvine. CA 926 4 Global Dosimetry Solutions Environmental Report Account

+--- 92255 Location 00O00ENV Monitorir,g Period 4/1/2020 I Process 1 0246283 I

W ISFSl-2 80 I Z-13-3 CONTROL 81 I Z-13-4 CONTROL 82 I Z-13-5 CONTROL 83 I Z-13-6 CONTROL 84 SPARE 85 2129-1 NW SWYD 86 Z-129-2 NW SWYD 87 Z-130-1 W SWYD 88 Z-130-2 W SWYD 89 Z-131-1 SW SWYD 90 Z-131-2 SW SWYD 91 I Z-109-1.5MI H 92 Z-109-2.5MI H 93 SPARE 98 SPARE 99 I Z-14-1 CONTROL 100 I Z-14-2 CONTROL ZION SOLUTIONS 20 19 21 19 17 17 16 19 18 26 29 17 15 20 19 21 20 18 18 18 20 18 15 15 18 18 27 26 17 16 19 18 19 19 20 18 19 19 19 17 16 17 18 29 26 17 16 19 18 20 21 20 18 20 19 18 16 16 18 18 27 27 17 16 19 18 20 20 Toll Free: (800) 251-3331 Tei. (949) 296-1800 Fax. (949) 296-1144 www.rnirion.com

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 5 of 7 REP41 29_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue Irvine, CA 92614 Global Dosimetry Solutions Environmental Report Process 102 103 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 92255 000001:NV 4/1/2020 0246283 Z-14-4 CONTROL Z-14-5 CONTROL SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE lsPARE ISPARE SPARE lsPARE lsPARE ZION $OLUT!ONS _________ ____

1 20 19 20 20 19 18 19 19 22 21 21 22 25 23 24 24 24 22 24 23 25 22 23 23 22 18 20 20 18 19 19 19 20 20 20 20 19 17 20 18 18 18 18 18 20 19 20 20 21 20 19 20 20 18 19 19 19 18 20 19 20 19 20 19 21 16 18 19

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Toll Free: (800) 251-3331 Tel. (949) 296-1800 Fax. (949) 296-1144 www mirion.com Page 6 of7 REP4129_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue

'rvine, CA 92614 Global Dosimetry Solutions Environmental Report Account -.,,

92255 ZilON SOLUTIONS Location'ti,~

~~:

OOOOOENIV Monitoring Period 4/1/2020 Process..

0246283 SPARE 18 618 lsPARE 18 I 18 19 620 lsPARE 19 I 18 21 621 lsPARE 20 I 19 19 19 20 19 Toll Free: (800) 251-3331 Tel. (949) 296-1800 Fax. (949) 296-~ 144

.mirion.com

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 7 of7 REP4129_0

MIRION TECHNOLOGIES October 28, 2020 ZION SOLUTIONS Attn: MARVIN MANNINEN 101 SHILOH BLVD ZION, IL 60099

Dear Marvin,

Dosimetry Services Div1sion 2652 McGaw /-\\venue Irvine. CA 92614 I

Enclosed is your environmental report for the locations, and wear periods listed below reported in units of mR:

Account 92255 92255 92255 Location Wear Date OOOOOENV 4/1/2020 OOOOOENV 7/1/2020 OOOOOENV 10/1/2020 As a reminder, no background has been applied. Only, fade and reader corrections have been applied. The Analysis and Reporting of these results are performed in accordance with the Mirion Technologies (GDS) Inc. Quality Assurance Manual and Standard Operating Procedure T-550 Production of Environmental Reports. If you have any questions please contact me at (949) 419-1000, ext. 2083.

Sincerely, Tam Hang Vo Dose Analysis Team Global Dosimetry Solutions, Inc.

0247142 REP4110_0 Toll Free: (300) 251-333 Tel (949) 296-180 Fax (949) 296-114 www mirion car

- MIRION TECHNOLOGl°ES Dosimetry Services Division 2652 McGaw Avenue Irvine, CA 92614 Global Dosimetry Solutions Environmental Report

~~e}i~*. *. ~-.. w~ 92255

. -~?'.tQ~ SO"'~TIQN§ _ __ __

't,'~-"_. '.*: ;:*-~~t.t,.:~ OOOOOENV

~!fj_ij;~.~i-4/1/2Q2.0.

P.r0g,,! :;..,.: /3 I' 0247142 619 SPARE

.. ~""

~ptssuJe flt~-. -**

,:~

~~(-r El'l,meAt~1 _mten;*a(t 3; -eJen,ent4 *mm*~t-Ayg 30 32 32 31

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Toll Free: (800) 251-333*

Tel (949) 296-180[

Fax. (949) 296-114, www.mirion.con Page 1 of6 REP4129_0

Pl MIRION TECHNOLOGIES Dosimetry Services Div rston 2652 McGaw Avenue 11-vine_ CA 92614 Global Dosimetry Solutions Environmental Report 92255 ___

ZION SOLUTIONS _____________ _ ___ ________ _

~~~* OO=-=O=O-=OE=N'"'"V~---------------------1 7

8 11 12 17 18 21 22 23 24 25 26 27 28 29 30 31 34 7/1/2020 _

0247142 Z-101-1 0.5MI A Z-101-2 0.5MI A Z-103-1 0.5MI C Z-103-2 0.5MI C I Z-106-1 0.5MI F Z-106-2 0.5MI E Z-108-1 0.5MI GH Z-108-2 0.5MI GH Z-110-1 0.5MI K Z-110-2 0.5MI K Z-111-10.5MIL Z-111-2 0.5MI L lz-112-1 2M1 M Z-112-2 2MI M Z-113-1 2MI N Z-113-2 2MI N Z-114-1 2MI P Z-115-2 0.5MI Q 12 14 14 14 11 I 15 16 I 15 13 I 14 16 13 16 17 17 15 17 15 16 16 18 17 13 14 15 15 14 15 15 16 15 17 17 I

17 16 17 15 tit1 15 16 15 16 15 13 14 14 13 15 16 15 15 17 I 17 I 17 I 13 14 16 15 13 15 16 16 16 17 17 17 15 16 14 14 15 I 17 __ J

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Toll Free: (800 ) 25 1-333' TE=I (948) 296-180(

Fax (949) 296-11 4' www rnirion con Page 2 of6 REP4129.0

MIRION TECHNOLOGIES Dosimetry Servic,s Division 2652 McGaw Avenue Irvine CA 92614 Global Dosimetry Solutions Environmental Report Accounj;~~---*.; ~22§5 __

Zl9N _SO~UTIONS _

~::.-!'),..... ":I:.;."~~

. rlo'cat(cinh -'IL:~

,; OOOOOENV

~.-.~ *-r... *. ~

  • . J.:'." _--,Y*

~~J~!tb~!.~~~ 7/1/2020 Pioce's&~J:

  • 0247142

~

~.,., ~

~

  • .~"':

.. lt..-__

.:~sitf -~,,~

diums,,~....,._. '.,,{ --~~i'........... t'J ""',

~

J:

il (i> t;.*:.t":

!f'lf. ex

  • fr~ R"':---*.... *., * -:" ~~-

"4;.* J?~.. IJL. ~.,,.:~* *.~

  • .~.... ~

........... ~

... ~ *e,.

~

e~meot;: :EJ~~ng *,~~~...... ~,"'1::) ):{fifnt.AVOi 37 Z-13-1 CONTROL 19 16 17 17 38 Z-13-2 CONTROL 16 17 16 16

~IZ-121-1 NSWYD I

14 I 14 14 I 14 lz-121-2 N swvo 15 I 13 I 14 I 14 44 Z-122-1 SSW SWYD 58 51 56 55 45 Z-122-2 SSW SWYD 55 48 53 52 46 Z-123-1 SSE SWYD 33 29 32 31 47 I Z-123-2 SSE SWYD I

43 37 36 39 48 lz-124-1 PROP sov L I

16 I 15 15 I 15 49 Z-124-2 PROP BDY L 16 16 16 16 50 Z-125-1 PROP BOY K 14 13 15 I 14 Toll Free (800) 251-333 '

Tei. (949) 296-180(

Fax (949) 296-1 1'1, www mldon con I

I 51 Z-125-2 PROP BDY K 15 15 15 ~ ---'

66 INE SWYD 1 I

13 13 13 13 67 NE SWYD-2 14 12 13 13 68 SE SWYD-1 16 15 16 16 I

69 lsESWYD-2 14 15 14 14 71 INE ISFSl-2 I

81 78 82 80 I

73 IE ISFSl-2 I

21 I 21 21 21

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Page 3 of6 REP4129_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue Irvine. CA 92614 Global Dosimetry Solutions Environmental Report

~~<;~l!Ji~.

-~ 9225~, __ ZION SOLUTIONS ____

  • Jt..*~-

Lbcatiori, *t.

g,. ~...

'l_,..'f_ 00000ENV M-PJ.lJ!9ri~siJ~.etto'(! 7J1l2P';.,Q Proc-.;.;,t:

  • _.. 0247142 "i..

-, ~....,*

ii<'*,..-~.........*. "V Nam

-. "-- "..,._11,.,_

77 S ISFSl-2 36 34 35 79 W ISFSl-2 66 63 66 80 Z-13-3 CONTROL 16 I 15 I 16

--8,~Z--13-C_O_N-TR_O_L ____ l __

17--:-l-1_7_

l_

16-82 lz-13-5CONTROL I

16 I 1s I 16 I 83 Z-13-6 CONTROL 17 16 17 84 SPARE 17 17 17 85 2129-1 NW SWYD 17 14 14 I

86 I Z-129-2 NW SWYD 14 I 12 13 87 Z-130-1 W SWYD 16 15 15 88 Z-130-2 W SWYD 15 15 15 I

89 Z-131-1 SW SWYD 28 25 25 I

90 lz-1s1-2 sw swvo

--r 24 I 24 I 23 I

91 Z-109-1.5MI H 15 15 15 92 Z-109-2.5MI H 16 16 16 93 SPARE

-109

-109

-116 I

98 SPARE I

15 15 I 14 35 65 16 17 16 17 17 15 13 15 15 26 23 15 16

-111 15

  • u- *

.1

...____6_02_

.... I_ z_-_1s_o_-1 _________

l _

2_1_

.......___ 2_1 _

.. __ 2_1 ______

2_1 _ J

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Toll rree (GOO) 2~11-333 Tel (949) 296-1 80(

Fax (949j 296-114, www.,nirion con Page 4 of6 REP4129.0

Pl MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue lrvine CA 9261<:i Global Dosimetry Solutions Environmental Report Account:.,-

.. 92255 ZION SOLUTIONS

~-,,_~--:,. ~-... __

. -~-

---~ ---~---...,_... ___ __ _

Location~,,-... ~.*:..... : OOOOOENV 603 Z-150-2 23 20 21 21 604 Z-151-1 23 23 21 22 605 Z-151-2 I 23 22 21 I

22 606

, -Z--1-52---1 _______, __ 1_8 _ _, ___ 19-- --1 r--1-8 _

607 lz-152-2 I

11 11 16 I 11 608 Z-153-1 17 15 16 16 610 Z-154-1 17 17 17 17 611 Z-154-2 17 16 16 16 lz-155-1 612 17 16 17 17 613 Z-155-2 16 16 16 16 615 SPARE 40 35 35 36 I 616 SPARE 24 22 22 23 I 617 fsPARE 19 17 I 19 19 I 618 SPARE 34 30 33 32 619 SPARE 18 18 17 18 620 SPARE 18 17 16 17 I 621 lsPARE 17 16 I 16 17

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

To!! Free: (300) 25*1-333 Tel. (9!.i9) 296-130(

Fsx (949) 296-114, wwvv. mrrlon con Page 5 of6 REP4128_0

MIRION TECHNOLOGIES Dosimetry Services Division 2652 McGaw Avenue Irvine, CA 92614 Global Dosimetry Solutions Environmental Report ZIQN_ SQ_LUTIONS

~

,:. 92255 _

, ' -.,,*. ; :t, **..,,, 0=0-=-00=0=E:.:..N:...,V'------------ ---------*

ir-~,~-~@i, ~ 0/1 /2020

,~o~ci---.*,.,.

~ 0247142

rm l.. ~

.. -,~-.,. *'*';.p*.* j~r.~~-~~,:-*~-:~ o~~-. i:-~-;~-!fi~

~*.

~;t;-~ 'QT~-,1

  • -~ *~....

etm,nf).w/.*

"\\l'l.

fl {

)

I J

I' i"

~

"-c.

,I

A,,.,.~.P,

.r- :"i....,~~.:l'\\r -A,

....,,;)_!'._~ ~

..... r I,

~

34 Z-115-2 0.5MI Q 5

5 5

5 84 SPARE 5

5 6

5 I

93 lsPARE 6

5 5

5 I

98 lsPARE I

5 5

I 5

5 614 SPARE 6

5 5

5 615 SPARE 5

5 5

5 616 SPARE 5

5 5

5 I

I 617 SPARE 6

5 5 =8 618 SPARE 5

5 5

619 SPARE 5

5 5

5 620 SPARE 6

4 5

5 621 SPARE I

5 5

5 5

  • - No control exposures have been subtracted, and only element, reader and fade corrections have been made.

Toll Free: (800) 251-3331 Tel. (949) 296-180(

Fax (949) 296-114L www.mirion.con-Page6 of6 REP4129_0

10/22/2020 Account Location Wear Date 92255 OOOOOARE 07/01/2020 92255 OOOOOARE 07/01/2020 92255 OOOOOENV 07/01/2020 92255 OOOOOSPR 07/01/2020 Pagel of 1 Control Element Value Report Badge Type 36 36 36 36 Process# 0247141 Wearer#

UIDNo El E2 E3 18699865 23 21 16 18699866 21 21 20 18699871 27 24 25 (I)

(I)

(I)

Global Dosimetry Sululiult!::>

E4 Fade Days Note Code j

28 122 31 122 43 122 (1)

Al Rep 4125_0

MIRION TECHNOLOGIES January 13, 2020 ZION SOLUTIONS Attn: MARVIN MANNINEN 101 SHILOH BLVD ZION, IL 60099

Dear Marvin,

Dosimetry Services Division 2652 McGaw Ave Irvine, CA 92614 Toll Free: (800) 251-3331 Tel: (949) 419-1000 Fax: (949) 296-1144 www.mirion.com Enclosed is the environmental report for the location, and wear period listed below reported in units of mR:

Account 92255 Location 00000ENV Wear Period 10/1/2020 As a reminder, no background has been applied. Only fade and reader corrections have been applied.

The Analysis and Reporting of these results are performed in accordance with the Mirion Technologies (GDS) Inc. Quality Assurance Manual and Standard Operating Procedures T-550 Production of Environmental Reports.

If you have any questions, please contact customer service.

Sincerely, ram,, II~ v~

Tam Hang Vo Dose Analysis Team

M I R I O N Dosimetry Services T E C H N O LO G I E S Division Toll Free: (800) 251-3331 Tel: (949) 419-1000 Fax: (949) 296-1144 www.mirion.com Global Dosimetry Solutions Environmental Report Account Location Monitoring Period Process Badge Number 7

8 11 12 17 18 21 22 23 24 25 26 27 28 29 30 31 32 37 38 39 40 44 45 46 47 48 49 so 51 66 67 Name CONTROL CONTROL-DAILY Z-101-1 0.5MI A Z-101-2 O.SMI A Z-103-1 0.5MI C Z-103-2 O.SMI C Z-106-1 O.SMI F Z-106-2 0.5MI E Z-108-1 0.5MI GH Z-108-2 O.SMI GH Z-110-1 0.5MI K Z-110-2 0.5MI K Z-111-1 O.SMI L Z-111-2 0.5MI L Z-112-1 2MI M Z-112-2 2MI M Z-113-1 2MI N Z-113-2 2MI N Z-114-1 2MI P Z-114-2 2MI P Z-13-1 CONTROL Z-13-2 CONTROL Z-121-1 N SWYD Z-121-2 N SWYD Z-122-1 SSW SWYD Z-122-2 SSW SWYD Z-123-1 SSE SWYD Z-123-2 SSE SWYD Z-124-1 PROP BDY L Z-124-2 PROP BDY L Z-125-1 PROP BOY K Z-125-2 PROP BDY K NESWYD 1 NE SWYD-2 92255 00000ENV 10/1/2020 247800 Element 2 18 12 15 14 16 16 17 16 15 15 17 15 16 17 14 15 14 14 15 14 16 16 13 13 52 51 31 35 12 15 14 14 14 13 ZION SOLUTIONS Element 3 Element 4 19 18 13 13 14 14 14 13 15 15 14 15 15 16 15 15 15 15 14 15 16 16 15 14 17 18 16 17 14 15 15 15 14 13 14 14 14 15 13 14 16 17 15 16 12 13 12 14 47 56 47 48 32 32 34 36 12 13 14 15 14 14 14 14 14 14 12 14 Note:* No control exposures have been subtracted, and only element, reader and fade correction have been made.

+- unusual element result observed. D-Element damaged and cannot be evaluated. G code-out of date.

ElmntAvg 18 13 14 14 15 15 16 15 15 15 16 15 17 16 14 15 14 14 14 14 16 16 13 13 52 49 31 35 12 15 14 14 14 13

MIRION Dosimetry Services Toll Free: (800) 251-3331 TECHNOLOGIES Division 68 SE SWYD-1 15 17 16 69 SE SWYD-2 15 15 15 70 NE ISFSl-1 71 69 71 71 NE ISFSl-2 74 73 76 72 E ISFSl-1 21 20 21 73 E ISFSl-2 21 21 22 76 S ISFSl-1 35 31 32 77 S ISFSl-2 35 32 37 78 W ISFSl-1 61 57 57 79 W ISFSl-2 61 57 59 80 Z-13-3 CONTROL 17 15 17 81 Z-13-4 CONTROL 16 16 16 82 Z-13-5 CONTROL 17 16 17 83 Z-13-6 CONTROL 17 16 16 85 Z129-1 NW SWYD 15 13 14 86 Z-129-2 NW SWYD 14 14 15 87 Z-130-1 W SWYD 15 14 15 88 Z-130-2 W SWYD 15 15 15 89 Z-131-1 SW SWYD 23 22 22 90 Z-131-2 SW SWYD 23 23 26 91 Z-109-1.5MI H 15 15 16 92 Z-109-2.SMI H 16 15 16 602 Z-150-1 20 19 20 603 Z-150-2 22 22 22 604 Z-151-1 22 20 20 605 Z-151-2 21 20 20 606 Z-152-1 19 18 18 607 Z-152-2 17 17 18 608 Z-153-1 16 16 15 609 Z-153-2 17 15 16 610 Z-154-1 18 16 17 611 Z-154-2 17 16 15 612 Z-155-1 18 17 17 613 Z-155-2 18 15 16 Note:* No control exposures have been subtracted, and only element, reader and fade correction have been made.

+- unusual element result observed. D-Element damaged and cannot be evaluated. G code-out of date.

Tel: (949} 419-1000 Fax: (949) 296-1144 www.mirion.com 16 15 70 74 21 21 33 35 58 59 16 16 17 17 14 14 15 15 23 24 15 16 20 22 21 20 18 17 15 16 17 16 17 16

MIRION TECHNOLOGIES Dosimetry Services Division Note:* No control exposures have been subtracted, and only element, reader and fade correction have been made.

+- unu~ual element result observed. D-E;lement damaged and cannot be evaluated. G code-out of date.

Toll Free: (800) 251-3331 Tel: (949) 419-1000 Fax: (949) 296-1144 www.mirion.com

Revision 12 January 30, 2020 Page 17 of 34 Table 11-1 Radiological Environmental Monitoring Program Exposure Pathway And/or Sample Sampling or Monitoring Locations Sampling or Collection Frequency Type and Frequency of Analysis

1. Direct Radiation
a.

Indicators - 0 to 0.5 mile Ring5 Z-129-1 and 2 0.29 mi N 0.47 km (A)

Z-101-1 and 2 0.40 mi NNE 0.65 km (B)

Z-121-1 and 2 0.31 mi NNE 0.51 km (B)

Z-103-1 and 2 0.39 mi NE 0.62 km (C)

Z-106-1 and 2 0.31 mi ENE 0.45 km(D)

Z-108-1 and 2 0.24 mi E 0.38 km (E)

Z-109-1 and 2 0.22 mi E 0.35 km (F)

Z-110-1 and 2 0.11 mi SE 0.18 km (G)

Z-125-1 and 2 0.15 mi SSE 0.24 km (H)

Z-155-1 and 2 0.10 mi SSE 0.16 km (H)

Z-154-1 and 2 0.09 mi S 0.15 km (J)

Z-111-1 and 2 0.11 mi SSW 0.17 km (K)

Z-124-1 and 2 0.16 mi SSW 0.26 km (K)

Z-153-1 and 2 0.11 mi SW 0.18 km (L)

Z-112-1 and 2 0.50 mi W 0.81 km (N)

Z-152-1 and 2 0.09 mi WSW 0.15 km (M)

Z-151-1 and 2 0.08 mi W 0.12 km (N)

Z-150-1 and 2 0.08 mi WNW 0.13 km (P)

Z-131-1 and 2 0.07 mi NW 0.11 km (Q)

Z-130-1 and 2 0.12 mi NNW 0.20 km (R)

b.

Indicators - greater than 0.5 miles Z-113-1 and 2 0.53 mi WNW 0.85 km (P)

Z-114-1 and 2 0.56 mi NW 0.90 km (Q)

c. One control at control airborne location Z13-1 thru Z13-6 13 mi NW 21.5 km (Q)

Quarterly Quarterly Quarterly Gamma dose on each TLD quarterly Gamma dose on each TLD quarterly Gamma dose on each TLD quarterly

5. Limited TLD placements due to Lake Michigan.

Revision 12 January 30, 2020 Page 18 of 34 Figure 11-1a Direct Radiation Sample Locations e

TLD Locations Property Boundary

~

Sector lines &

~

1/2 mile radius N

A Z-13 CD CD

g.

)>

< *