NRC FORM 699 U.S. NUCLEAR REGULATORY COMMISSION (11-2017)

CONVERSATION RECORD NAME OF PERSON(S)/TITLE CONTACTED OR IN CONTACT WITH YOU DATE OF CONTACT TYPE OF CONVERSATION 09/14/2020 E-MAIL E-MAIL ADDRESS TELEPHONE NUMBER TELEPHONE INCOMING OUTGOING ORGANIZATION DOCKET NUMBER(S)

Holtec International 72-1040 LICENSE NAME AND NUMBER(S) MAIL CONTROL NUMBER(S)

SUBJECT HI-STORM UMAX Amendment No. 3, Clarification Call for Response to RAI 5, 14, and 16

SUMMARY

AND ACTION REQUIRED (IF ANY)

Holtec Attendees: Chuck Bullard and Kim Manzione NRC Attendees: Yen-Ju Chen, Tom Boyce, John McKirgan, and Tony Rigato This is a call to clarify Holtec's response to RAI 5, 14, and 16. NRC has shared the clarification questions (proprietary) prior to the meeting. During the meeting, the attendees discussed each RAI to ensure Holtec understands the staff's concern. Holtec will determine how to address each question and provide supplemental information to these RAIs.

NAME OF PERSON DOCUMENTING CONVERSATION Yen-Ju Chen SIGNATURE DATE OF SIGNATURE Digitally signed by Yen-Ju Chen Yen-Ju Chen Date: 2021.01.15 11:46:02

-05'00' NRC Form 699 (11-2017) Page 1 of 1