ML20343A189

From kanterella
Jump to navigation Jump to search
Cover, Table of Contents and Introduction
ML20343A189
Person / Time
Issue date: 08/31/2020
From: Borowski J, Michel Call, Darrell Dunn, Antonio Rigato, James Smith, Jorge Solis, Jeremy Tapp, Bernie White
Division of Fuel Management
To:
SKumar - NMSS/DFM/NARAB
Shared Package
ML20343A188 List:
References
NUREG-2216
Download: ML20343A189 (32)


Text

NUREG-2216 Standard Review Plan for Transportation Packages for Spent Fuel and Radioactive Material Final Report Office of Nuclear Material Safety and Safeguards

NRC Reference Material As of November 1999, you may electronically access NUREG-series publications and other NRC records at the NRCs Public Electronic Reading Room at http://www.nrc.gov/reading-rm.html. Publicly released records include, to name a few, NUREG-series publications; Federal Register notices; applicant, licensee, and vendor documents and correspondence; NRC correspondence and internal memoranda; bulletins and information notices; inspection and investigative reports; licensee event reports; and Commission papers and their attachments.

NRC publications in the NUREG series, NRC regulations, and Title 10, Energy, in the Code of Federal Regulations may also be purchased from one of these two sources.

1. The Superintendent of Documents U.S. Government Publishing Office Washington, DC 20402-0001 Internet: http://bookstore.gpo.gov Telephone: 1-866-512-1800 Fax: (202) 512-2104
2. The National Technical Information Service 5301 Shawnee Road Alexandria, VA 22161-0002 http://www.ntis.gov 1-800-553-6847 or, locally, (703) 605-6000 A single copy of each NRC draft report for comment is available free, to the extent of supply, upon written request as follows:

U.S. Nuclear Regulatory Commission Office of Administration Multimedia, Graphics and Storage & Distribution Branch Washington, DC 20555-0001 E-mail: distribution.resource@nrc.gov Facsimile: (301) 415-2289 Some publications in the NUREG series that are posted at the NRCs Web site address http://www.nrc.gov/reading-rm/doc-collections/nuregs are updated periodically and may differ from the last printed version. Although references to material found on a Web site bear the date the material was accessed, the material available on the date cited may subsequently be removed from the site.

Non-NRC Reference Material Documents available from public and special technical libraries include all open literature items, such as books, journal articles, transactions, Federal Register notices, Federal and State legislation, and congressional reports.

Such documents as theses, dissertations, foreign reports and translations, and non-NRC conference proceedings may be purchased from their sponsoring organization.

Copies of industry codes and standards used in a substantive manner in the NRC regulatory process are maintained at The NRC Technical Library Two White Flint North 11545 Rockville Pike Rockville, MD 20852-2738 These standards are available in the library for reference use by the public. Codes and standards are usually copyrighted and may be purchased from the originating organization or, if they are American National Standards, from American National Standards Institute 11 West 42nd Street New York, NY 10036-8002 http://www.ansi.org (212) 642-4900 AVAILABILITY OF REFERENCE MATERIALS IN NRC PUBLICATIONS Legally binding regulatory requirements are stated only in laws; NRC regulations; licenses, including technical specifications; or orders, not in NUREG-series publications. The views expressed in contractor-prepared publications in this series are not necessarily those of the NRC.

The NUREG series comprises (1) technical and administrative reports and books prepared by the staff (NUREG-XXXX) or agency contractors (NUREG/CR-XXXX), (2) proceedings of conferences (NUREG/CP-XXXX), (3) reports resulting from international agreements (NUREG/IA-XXXX), (4) brochures (NUREG/BR-XXXX), and (5) compilations of legal decisions and orders of the Commission and Atomic and Safety Licensing Boards and of Directors decisions under Section 2.206 of NRCs regulations (NUREG-0750).

DISCLAIMER: This report was prepared as an account of work sponsored by an agency of the U.S. Government.

Neither the U.S. Government nor any agency thereof, nor any employee, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for any third partys use, or the results of such use, of any information, apparatus, product, or process disclosed in this publication, or represents that its use by such third party would not infringe privately owned rights.

SR-CR 10/2017

NUREG-2216 Standard Review Plan for Transportation Packages for Spent Fuel and Radioactive Material Final Report Office of Nuclear Material Safety and Safeguards Manuscript Completed: February 2020 Date Published: August 2020 Prepared by:

Joseph Borowski Michel Call Darrell Dunn Antonio Rigato Jeremy Smith Jorge Solis Jeremy Tapp Bernard White

iii ABSTRACT This Standard Review Plan (SRP) provides guidance to the U.S. Nuclear Regulatory Commission (NRC) staff for reviewing an application for package approval issued under Title 10 of the Code of Federal Regulations (10 CFR), Part 71, Packaging and Transportation of Radioactive Material. NRC approval of a package design typically results in issuance of a certificate of compliance (CoC) or a letter amendment for a transportation package.

The objectives of this SRP are to assist the NRC staff in its reviews by providing a basis that promotes uniform quality and a consistent regulatory review of an application for a CoC for a transportation package presenting a basis for the reviews scope identifying acceptable approaches to meeting regulatory requirements suggesting possible evaluation findings that can be used in the safety evaluation report This SRP was published for public comment, and the responses to those comments are available at ML20023A361. This SRP may be revised and updated as the need arises on a chapter-by-chapter basis to clarify the content, correct errors, or incorporate modifications approved by the Director of the NRC Division of Spent Fuel Management. Comments, suggestions for improvement, and notices of errors or omissions should be sent to and will be considered by the Director, Division of Spent Fuel Management, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001.

v TABLE OF CONTENTS ABSTRACT................................................................................................................... iii TABLE OF CONTENTS.................................................................................................. v LIST OF FIGURES........................................................................................................ xv LIST OF TABLES........................................................................................................xvii ABBREVIATIONS AND ACRONYMS......................................................................... xix INTRODUCTION......................................................................................................... xxv 1

GENERAL INFORMATION EVALUATION....................................................... 1-1 1.1 Review Objective..............................................................................................1-1 1.2 Areas of Review................................................................................................1-1 1.3 Regulatory Requirements and Acceptance Criteria...........................................1-2 1.3.1 Drawings............................................................................................1-3 1.3.2 Quality Assurance..............................................................................1-4 1.4 Review Procedures...........................................................................................1-4 1.4.1 Package Design Information...............................................................1-5 1.4.1.1 Purpose of application...........................................................1-5 1.4.1.2 Proposed use and contents...................................................1-6 1.4.1.3 Package type and model number..........................................1-6 1.4.1.4 Package category and maximum activity...............................1-6 1.4.1.5 Codes and standards............................................................1-7 1.4.1.6 Criticality safety index............................................................1-7 1.4.1.7 Quality assurance program...................................................1-7 1.4.2 Package Description...........................................................................1-7 1.4.2.1 Packaging.............................................................................1-7 1.4.2.2 Operational features..............................................................1-8 1.4.2.3 Contents of packaging...........................................................1-9 1.4.3 Summary of Compliance with 10 CFR Part 71.................................. 1-11 1.4.3.1 General requirements of 10 CFR 71.43............................... 1-11 1.4.3.2 Condition of package after tests in 10 CFR 71.71 and 10 CFR 71.73...................................................................... 1-11 1.4.3.3 Structural, Thermal, Containment, Shielding, Criticality, Materials............................................................. 1-11 1.4.3.4 Operational procedures, acceptance tests, and maintenance....................................................................... 1-11 1.4.4 Certification Approach for Commercial Spent Nuclear Fuel.............. 1-11 1.4.5 Drawings.......................................................................................... 1-12 1.4.6 Appendix.......................................................................................... 1-14 1.5 Evaluation Findings......................................................................................... 1-15 1.6 References..................................................................................................... 1-16

vi 2

STRUCTURAL EVALUATION.......................................................................... 2-1 2.1 Review Objective..............................................................................................2-1 2.2 Areas of Review................................................................................................2-1 2.3 Regulatory Requirements and Acceptance Criteria...........................................2-2 2.4 Review Procedures...........................................................................................2-2 2.4.1 Description of Structural Design.........................................................2-3 2.4.1.1 General.................................................................................2-3 2.4.1.2 Identification of codes and standards for package design...................................................................................2-5 2.4.2 General Requirements for All Packages.............................................2-7 2.4.2.1 Minimum package size..........................................................2-7 2.4.2.2 Tamper-indicating feature.....................................................2-7 2.4.2.3 Positive closure.....................................................................2-7 2.4.2.4 Package valve.......................................................................2-7 2.4.3 Lifting and Tie-Down Standards for All Packages...............................2-8 2.4.3.1 Lifting devices.......................................................................2-8 2.4.3.2 Tie-down devices..................................................................2-8 2.4.4 General Considerations for Structural Evaluation of Packaging..........2-9 2.4.4.1 Evaluation by analysis...........................................................2-9 2.4.4.2 Evaluation by test................................................................ 2-10 2.4.5 Normal Conditions of Transport........................................................ 2-12 2.4.5.1 Heat.................................................................................... 2-12 2.4.5.2 Cold.................................................................................... 2-13 2.4.5.3 Reduced external pressure................................................. 2-13 2.4.5.4 Increased external pressure................................................ 2-13 2.4.5.5 Vibration and fatigue........................................................... 2-14 2.4.5.6 Water spray......................................................................... 2-14 2.4.5.7 Free drop............................................................................ 2-14 2.4.5.8 Corner drop......................................................................... 2-14 2.4.5.9 Compression....................................................................... 2-14 2.4.5.10 Penetration.......................................................................... 2-15 2.4.6 Hypothetical Accident Conditions..................................................... 2-15 2.4.6.1 Free drop............................................................................ 2-16 2.4.6.2 Crush.................................................................................. 2-16 2.4.6.3 Puncture.............................................................................. 2-16 2.4.6.4 Thermal............................................................................... 2-17 2.4.6.5 Immersionfissile material................................................. 2-17 2.4.6.6 Immersionall packages.................................................... 2-17 2.4.7 Air Transport Accident Conditions for Fissile Material....................... 2-17 2.4.7.1 Free drop............................................................................ 2-18 2.4.7.2 Crush test............................................................................ 2-18 2.4.7.3 Puncture test....................................................................... 2-18 2.4.7.4 Thermal Test....................................................................... 2-18 2.4.7.5 90-meter-per-second Impact............................................... 2-18 2.4.8 Special Requirement for Type B Packages Containing More Than 105 A2...................................................................................... 2-18 2.4.9 Air Transport of Plutonium................................................................ 2-19 2.4.10 Appendix.......................................................................................... 2-19 2.5 Evaluation Findings......................................................................................... 2-20 2.6 References..................................................................................................... 2-21

vii ATTACHMENT 2A COMPUTATIONAL MODELING SOFTWARE TECHNICAL REVIEW GUIDANCE.............................................................. 2-25 3

THERMAL EVALUATION................................................................................. 3-1 3.1 Review Objective..............................................................................................3-1 3.2 Areas of Review................................................................................................3-1 3.3 Regulatory Requirements and Acceptance Criteria...........................................3-2 3.3.1 Description of the Thermal Design......................................................3-2 3.3.2 Material Properties and Component Specifications.............................3-2 3.3.3 General Considerations for Thermal Evaluations................................3-4 3.3.4 Evaluation of Accessible Surface Temperatures.................................3-4 3.3.5 Thermal Evaluation Under Normal Conditions of Transport................3-4 3.3.6 Thermal Evaluation Under Hypothetical Accident Conditions.............3-4 3.4 Review Procedures...........................................................................................3-5 3.4.1 Description of the Thermal Design......................................................3-7 3.4.1.1 Packaging design features....................................................3-7 3.4.1.2 Codes and standards............................................................3-8 3.4.1.3 Content heat load specification.............................................3-8 3.4.1.4 Summary tables of temperatures...........................................3-8 3.4.1.5 Summary tables of pressures in the containment system...................................................................................3-9 3.4.2 Material Properties and Component Specifications.............................3-9 3.4.2.1 Material thermal properties....................................................3-9 3.4.2.2 Specifications of components.............................................. 3-11 3.4.2.3 Thermal design limits of package materials and components........................................................................ 3-11 3.4.3 General Considerations for Thermal Evaluations.............................. 3-11 3.4.3.1 Evaluation by analyses........................................................ 3-12 3.4.3.2 Evaluation by Tests............................................................. 3-13 3.4.3.3 Confirmatory analyses......................................................... 3-15 3.4.3.4 Effects of uncertainties........................................................ 3-15 3.4.3.5 Conservatisms.................................................................... 3-15 3.4.4 Evaluation of Accessible Surface Temperatures............................... 3-16 3.4.5 Thermal Evaluation Under Normal Conditions of Transport.............. 3-16 3.4.5.1 Heat and cold...................................................................... 3-16 3.4.5.2 Maximum normal operating pressure.................................. 3-17 3.4.6 Thermal Evaluation Under Hypothetical Accident Conditions........... 3-19 3.4.6.1 Initial conditions................................................................... 3-19 3.4.6.2 Fire test............................................................................... 3-19 3.4.6.3 Maximum temperatures and pressures............................... 3-20 3.4.7 Appendix.......................................................................................... 3-21 3.4.7.1 Radioactive materials.......................................................... 3-21 3.4.7.2 Spent nuclear fuel............................................................... 3-23 3.5 Evaluation Findings......................................................................................... 3-25 3.6 References..................................................................................................... 3-26 4

CONTAINMENT EVALUATION........................................................................ 4-1 4.1 Review Objective..............................................................................................4-1 4.2 Areas of Review................................................................................................4-1 4.3 Regulatory Requirements and Acceptance Criteria...........................................4-1

viii 4.3.1 General Requirements.......................................................................4-2 4.3.2 Containment Under Normal Conditions of Transport..........................4-3 4.3.3 Containment Under Hypothetical Accident Conditions........................4-4 4.4 Review Procedures...........................................................................................4-4 4.4.1 Description of the Containment System..............................................4-4 4.4.1.1 Containment boundary..........................................................4-4 4.4.1.2 Codes and standards............................................................4-7 4.4.1.3 Special requirements for damaged spent nuclear fuel...........4-7 4.4.2 General Considerations for Containment Evaluations.........................4-7 4.4.2.1 Type AF fissile packages......................................................4-7 4.4.2.2 Type B packages..................................................................4-7 4.4.2.3 Combustible-gas generation..................................................4-8 4.4.3 Containment Evaluation under Normal Conditions of Transport..........4-9 4.4.3.1 Type B transportation packages............................................4-9 4.4.3.2 Spent nuclear fuel transportation packages...........................4-9 4.4.3.3 Compliance with containment design criteria....................... 4-10 4.4.4 Containment Evaluation Under Hypothetical Accident Conditions........................................................................................ 4-11 4.4.4.1 Type B transportation packages.......................................... 4-11 4.4.4.2 Spent nuclear fuel transportation packages......................... 4-12 4.4.4.3 Compliance with containment design criterion..................... 4-12 4.4.5 Leakage Rate Tests for Type B Packages........................................ 4-12 4.4.6 Appendix.......................................................................................... 4-13 4.5 Evaluation Findings......................................................................................... 4-13 4.6 References..................................................................................................... 4-14 5

SHIELDING EVALUATION............................................................................... 5-1 5.1 Review Objective..............................................................................................5-1 5.2 Areas of Review................................................................................................5-1 5.3 Regulatory Requirements and Acceptance Criteria...........................................5-1 5.4 Review Procedures...........................................................................................5-5 5.4.1 Description of Shielding Design..........................................................5-6 5.4.1.1 Shielding design features......................................................5-7 5.4.1.2 Summary tables of maximum external radiation levels........ 5-10 5.4.2 Radioactive Materials and Source Terms......................................... 5-12 5.4.2.1 Source-term calculation methods........................................ 5-14 5.4.2.2 Gamma sources.................................................................. 5-16 5.4.2.3 Neutron sources.................................................................. 5-18 5.4.3 Shielding Model and Model Specifications........................................ 5-20 5.4.3.1 Configuration of source and shielding................................. 5-20 5.4.3.2 Material properties.............................................................. 5-22 5.4.4 Shielding Evaluation......................................................................... 5-23 5.4.4.1 Methods.............................................................................. 5-23 5.4.4.2 Code input and output data................................................. 5-26 5.4.4.3 Fluence-rate-to-radiation-level conversion factors............... 5-27 5.4.4.4 External radiation levels...................................................... 5-28 5.4.4.5 Confirmatory analyses......................................................... 5-31 5.4.5 Appendix.......................................................................................... 5-32 5.5 Evaluation Findings......................................................................................... 5-32 5.6 References..................................................................................................... 5-33

ix 6

CRITICALITY EVALUATION............................................................................ 6-1 6.1 Review Objective..............................................................................................6-1 6.2 Areas of Review................................................................................................6-1 6.3 Regulatory Requirements and Acceptance Criteria...........................................6-2 6.4 Review Procedures...........................................................................................6-4 6.4.1 Description of Criticality Design..........................................................6-5 6.4.1.1 Packaging design features....................................................6-5 6.4.1.2 Codes and standards............................................................6-6 6.4.1.3 Summary table of criticality evaluations.................................6-7 6.4.1.4 Criticality safety index............................................................6-7 6.4.2 Contents.............................................................................................6-8 6.4.3 General Considerations for Criticality Evaluations............................ 6-11 6.4.3.1 Model configuration............................................................. 6-11 6.4.3.2 Material properties.............................................................. 6-12 6.4.3.3 Analysis methods and nuclear data..................................... 6-13 6.4.3.4 Demonstration of maximum reactivity.................................. 6-14 6.4.3.5 Confirmatory analyses......................................................... 6-15 6.4.3.6 Moderator exclusion under hypothetical accident conditions............................................................................ 6-15 6.4.4 Single Package Evaluation............................................................... 6-16 6.4.4.1 Configuration....................................................................... 6-16 6.4.4.2 Results................................................................................ 6-17 6.4.5 Evaluations of Package Arrays......................................................... 6-17 6.4.5.1 Package arrays under normal conditions of transport.......... 6-17 6.4.5.2 Evaluation of package arrays under hypothetical accident conditions.............................................................. 6-17 6.4.5.3 Package arrays results and criticality safety index............... 6-18 6.4.6 Benchmark Evaluations.................................................................... 6-18 6.4.6.1 Experiments and applicability.............................................. 6-19 6.4.6.2 Bias determination.............................................................. 6-19 6.4.7 Burnup Credit Evaluation for Commercial Light-Water Reactor Spent Nuclear Fuel........................................................................... 6-20 6.4.7.1 Limits for the certification basis........................................... 6-22 6.4.7.2 Model assumptions............................................................. 6-22 6.4.7.3 Code validationisotopic depletion..................................... 6-24 6.4.7.4 Code validationkeff determination..................................... 6-25 6.4.7.5 Loading curve and burnup verification................................. 6-27 6.4.8 Appendix.......................................................................................... 6-29 6.5 Evaluation Findings......................................................................................... 6-29 6.6 References..................................................................................................... 6-31 ATTACHMENT 6A TECHNICAL RECOMMENDATIONS FOR THE CRITICALITY SAFETY REVIEW OF PRESSURIZED-WATER REACTOR SPENT NUCLEAR FUEL TRANSPORTATION PACKAGES AND STORAGE CASKS THAT USE BURNUP CREDIT.......... 6-35 7

MATERIALS EVALUATION............................................................................. 7-1 7.1 Review Objective..............................................................................................7-1 7.2 Areas of Review................................................................................................7-1 7.3 Regulatory Requirements and Acceptance Criteria...........................................7-2

x 7.4 Review Procedures...........................................................................................7-4 7.4.1 Drawings............................................................................................7-4 7.4.2 Codes and Standards.........................................................................7-6 7.4.2.1 Usage and endorsement.......................................................7-7 7.4.2.2 ASME code components.......................................................7-7 7.4.2.3 Code case use/acceptability..................................................7-7 7.4.2.4 Non-ASME code components...............................................7-8 7.4.3 Weld Design and Inspection...............................................................7-8 7.4.3.1 Moderator exclusion for commercial spent nuclear fuel packages under hypothetical accident conditions..................7-9 7.4.4 Mechanical Properties........................................................................7-9 7.4.4.1 Tensile properties..................................................................7-9 7.4.4.2 Fracture resistance............................................................. 7-10 7.4.4.3 Tensile properties and creep of aluminum alloys at elevated temperatures......................................................... 7-11 7.4.4.4 Impact limiters..................................................................... 7-12 7.4.5 Thermal Properties of Materials........................................................ 7-12 7.4.6 Radiation Shielding........................................................................... 7-12 7.4.6.1 Neutron-shielding materials................................................. 7-13 7.4.6.2 Gamma-shielding materials................................................. 7-13 7.4.7 Criticality Control.............................................................................. 7-14 7.4.7.1 Neutron-absorbing (poison) material specification............... 7-14 7.4.7.2 Computation of percent credit for boron-based neutron absorbers............................................................................ 7-15 7.4.7.3 Qualifying properties not Associated with attenuation.......... 7-16 7.4.8 Corrosion Resistance....................................................................... 7-18 7.4.8.1 Environments...................................................................... 7-19 7.4.8.2 Carbon and low-alloy steels................................................ 7-19 7.4.8.3 Austenitic stainless steel..................................................... 7-19 7.4.9 Protective Coatings.......................................................................... 7-20 7.4.9.1 Review guidance................................................................. 7-20 7.4.9.2 Scope of coating application................................................ 7-20 7.4.9.3 Coating selection................................................................. 7-20 7.4.9.4 Coating qualification testing................................................. 7-21 7.4.10 Content Reactions............................................................................ 7-21 7.4.10.1 Flammable and explosive reactions.................................... 7-21 7.4.10.2 Content chemical reactions, outgassing, and corrosion....... 7-22 7.4.11 Radiation Effects.............................................................................. 7-23 7.4.12 Package Contents............................................................................ 7-24 7.4.13 Fresh (Unirradiated) Fuel Cladding................................................... 7-24 7.4.14 Spent Nuclear Fuel........................................................................... 7-25 7.4.14.1 Spent fuel classification....................................................... 7-25 7.4.14.2 Uncanned spent fuel........................................................... 7-26 7.4.14.3 Canned spent fuel............................................................... 7-33 7.4.15 Bolting Material................................................................................. 7-34 7.4.16 Seals................................................................................................ 7-34 7.4.16.1 Metallic seals....................................................................... 7-35 7.4.16.2 Elastomeric seals................................................................ 7-35 7.5 Evaluation Findings......................................................................................... 7-36 7.6 References..................................................................................................... 7-37

xi ATTACHMENT 7A CLARIFICATIONS, GUIDANCE, AND EXCEPTIONS TO ASTM STANDARD PRACTICE C1671-15........................................ 7-43 ATTACHMENT 7B FUEL SELECTION.................................................................. 7-49 8

OPERATING PROCEDURES EVALUATION................................................... 8-1 8.1 Review Objective..............................................................................................8-1 8.2 Areas of Review................................................................................................8-1 8.3 Regulatory Requirements and Acceptance Criteria...........................................8-1 8.3.1 Package Loading................................................................................8-1 8.3.2 Package Unloading............................................................................8-2 8.3.3 Preparation of Empty Package for Transport......................................8-2 8.3.4 Other Procedures...............................................................................8-2 8.4 Review Procedures...........................................................................................8-2 8.4.1 Package Loading................................................................................8-3 8.4.1.1 Preparation for loading..........................................................8-3 8.4.1.2 Loading of contents...............................................................8-4 8.4.1.3 Preparation for transport.......................................................8-4 8.4.2 Package Unloading............................................................................8-6 8.4.2.1 Receipt of package from carrier............................................8-6 8.4.2.2 Preparations for unloading....................................................8-6 8.4.2.3 Removal of contents..............................................................8-7 8.4.3 Preparation of Empty Package for Transport......................................8-7 8.4.4 Other Procedures...............................................................................8-7 8.5 Evaluation Findings...........................................................................................8-7 8.6 References.......................................................................................................8-8 9

ACCEPTANCE TESTS AND MAINTENANCE PROGRAM EVALUATION.... 9-1 9.1 Review Objective..............................................................................................9-1 9.2 Areas of Review................................................................................................9-1 9.3 Regulatory Requirements and Acceptance Criteria...........................................9-1 9.3.1 Acceptance Tests...............................................................................9-2 9.3.2 Maintenance Program........................................................................9-2 9.4 Review Procedures...........................................................................................9-2 9.4.1 Acceptance Tests...............................................................................9-3 9.4.1.1 Visual inspections and measurements..................................9-3 9.4.1.2 Weld examinations................................................................9-3 9.4.1.3 Structural and pressure tests.................................................9-4 9.4.1.4 Leakage tests........................................................................9-5 9.4.1.5 Component and material tests...............................................9-5 9.4.1.6 Neutron-absorber and moderator tests..................................9-5 9.4.1.7 Shielding tests.......................................................................9-6 9.4.1.8 Thermal tests........................................................................9-6 9.4.2 Maintenance Program........................................................................9-6 9.4.2.1 Structural and pressure tests.................................................9-6 9.4.2.2 Leakage tests........................................................................9-6 9.4.2.3 Component and materials tests.............................................9-7 9.4.2.4 Neutron-absorber and moderator tests..................................9-7 9.4.2.5 Shielding tests.......................................................................9-7 9.4.2.6 Thermal tests........................................................................9-7

xii 9.4.2.7 Miscellaneous tests...............................................................9-7 9.5 Evaluation Findings...........................................................................................9-8 9.6 References.......................................................................................................9-8 10 QUALITY ASSURANCE EVALUATION......................................................... 10-1 10.1 Review Objective............................................................................................ 10-1 10.2 Areas of Review.............................................................................................. 10-1 10.3 Regulatory Requirements and Acceptance Criteria......................................... 10-1 10.4 Review Procedures......................................................................................... 10-2 10.4.1 Quality Assurance Organization....................................................... 10-3 10.4.2 Quality Assurance Program.............................................................. 10-4 10.4.3 Package Design Control................................................................... 10-5 10.4.4 Procurement Document Control....................................................... 10-6 10.4.5 Instructions, Procedures, and Drawings........................................... 10-7 10.4.6 Document Control............................................................................. 10-8 10.4.7 Control of Purchased Material, Equipment, and Services................. 10-8 10.4.8 Identification and Control of Materials, Parts, and Components...... 10-10 10.4.9 Control of Special Processes.......................................................... 10-11 10.4.10 Internal Inspection.......................................................................... 10-11 10.4.11 Test Control.................................................................................... 10-12 10.4.12 Control of Measuring and Test Equipment...................................... 10-13 10.4.13 Handling, Storage, and Shipping Control........................................ 10-13 10.4.14 Inspection, Test, and Operating Status........................................... 10-14 10.4.15 Nonconforming Materials, Parts, or Components........................... 10-14 10.4.16 Corrective Action............................................................................ 10-15 10.4.17 Quality Assurance Records............................................................ 10-15 10.4.18 Audits.......................................................................................... 10-16 10.5 Evaluation Findings....................................................................................... 10-17 10.6 References................................................................................................... 10-18 11 GLOSSARY.................................................................................................... 11-1 APPENDIX A DESCRIPTION, SAFETY FEATURES, AND AREAS OF REVIEW FOR DIFFERENT TYPES OF RADIOACTIVE MATERIAL TRANSPORTATION PACKAGES.................................................... A-1 APPENDIX B DIFFERENCES BETWEEN THERMAL AND RADIATION PROPERTIES OF MIXED OXIDE AND LOW-ENRICHED URANIUM RADIOACTIVE MATERIALS.......................................... B-1 APPENDIX C DIFFERENCES BETWEEN THERMAL AND RADIATION PROPERTIES OF MIXED OXIDE AND LOW-ENRICHED URANIUM SPENT NUCLEAR FUEL................................................ C-1 APPENDIX D BENCHMARK CONSIDERATIONS FOR MIXED OXIDE RADIOACTIVE MATERIALS AND SPENT NUCLEAR FUEL.......... D-1

xiii APPENDIX E DESCRIPTION AND REVIEW PROCEDURES FOR IRRADIATED TRITIUM-PRODUCING BURNABLE ABSORBER RODS PACKAGES................................................... E-1 ATTACHMENT A PHYSICAL AND CHEMICAL PROPERTIES OF TRITIUM..... E-35 ATTACHMENT B BIOLOGICAL PROPERTIES OF TRITIUM AND TRITIUM HEALTH PHYSICS................................................................... E-51

xv LIST OF FIGURES Figure 1-1 Overview of General Information Evaluation...................................................... 1-5 Figure 2-1 Information Flow for the Structural Evaluation................................................... 2-4 Figure 3-1 Information Flow for the Thermal Evaluation..................................................... 3-6 Figure 4-1 Information Flow for the Containment Evaluation.............................................. 4-5 Figure 5-1 Information Flow for the Shielding Evaluation.................................................... 5-7 Figure 5-2 Illustration of Surfaces to Which Regulatory Radiation Limits Apply for Exclusive-Use and Non-Exclusive-Use Shipments.......................................... 5-11 Figure 5-3 Cutaway Images Depicting Package Surfaces and Radiation Level Limits for Packages with Complex Surfaces........................................... 5-29 Figure 6-1 Information Flow for the Criticality Evaluation.................................................... 6-6 Figure 6A-1 Reactivity Behavior In The GBC-32 As A Function Of Cooling Time For Fuel With 4.0 Weight Percent Uranium-235 Initial Enrichment And 40 Gwd/MTU Burnup....................................................................................... 6-40 Figure 6A-2 Reactivity Effect Of Fuel Temperature During Depletion On Kinf In An Array Of Poisoned Storage Cells; Results Correspond To Fuel With 5.0 Weight Percent Initial Uranium-235 Enrichment........................................ 6-42 Figure 6A-3 Reactivity Effect Of Moderator Temperature During Depletion On Kinf In An Array Of Poisoned Storage Cells; Results Correspond To Fuel With 5.0 Weight Percent Initial Uranium-235 Enrichment................................ 6-42 Figure 6A-4 Reactivity Effect Of Soluble Boron Concentration During Depletion On Kinf In An Array Of Poisoned Storage Cells; Results Correspond To Fuel With 5.0 Weight Percent Initial Uranium-235 Enrichment......................... 6-43 Figure 6A-5 Reactivity Effect Of Specific Power During Depletion On Kinf In An Array Of Fuel Pins (Actinides Only)................................................................. 6-44 Figure 6A-6 Reactivity Effect Of Specific Power During Depletion On Kinf In An Array Of Fuel Pins (Actinides And Fission Products)....................................... 6-45 Figure 6A-7 Effect Of Axial Burnup Distribution On Keff In The GBC-32 For Actinide-Only Burnup Credit And Various Cooling Times For Fuel With 4.0 Weight Percent Initial Enrichment.............................................................. 6-47 Figure 6A-8 Representative Loading Curves And Discharged PWR Population................. 6-58

xvi Figure 7-1 Information Flow for the Materials Evaluation.................................................... 7-5 Figure 7A-1 Plot of the Effective Neutron Multiplication Factor, keff, as a Function of Heterogeneity Size.......................................................................................... 7-46 Figure 8-1 Information Flow for the Operating Procedures Evaluation................................ 8-5 Figure 9-1 Information Flow for the Acceptance Tests and Maintenance Program Evaluation........................................................................................... 9-4

xvii LIST OF TABLES Table 1 Interim Staff Guidance (ISGs) Incorporated Into This Standard Review Plan................................................................................... xxviii Table 1-1 Relationship of Regulations and Areas of Review for Transportation Packages......................................................................................................... 1-3 Table 1-2 Summary of Approaches for Demonstrating Subcriticality of SNF Under the Requirements of 10 CFR 71.55(e)........................................................... 1-13 Table 2-1 Relationship of Regulations and Areas of Review for Transportation Packages......................................................................................................... 2-3 Table 3-1 Relationship of Regulations and Areas of Review for Transportation Packages......................................................................................................... 3-3 Table 4-1 Relationship of Regulations and Areas of Review for Transportation Packages......................................................................................................... 4-2 Table 4-2 Release Fractions and Specific Activities for the Contributors to the Releasable Source Term for Packages Designed to Transport Irradiated Fuel Rodsa,b................................................................................................... 4-11 Table 5-1 Relationship of Regulations and Areas of Review for Transportation Packages......................................................................................................... 5-2 Table 5-2 Package and Vehicle External Radiation Level Limitsa..................................... 5-2 Table 6-1 Relationship of Regulations and Areas of Review for Transportation Packages......................................................................................................... 6-3 Table 6-2 Recommended Set of Nuclides for Burnup Credit.......................................... 6-23 Table 6-3 Isotopic keff Bias Uncertainty (ki) for the Representative PWR SNF System Model Using ENDF/B-VII Data (i = 0) as a Function of Assembly Average Burnup............................................................................. 6-26 Table 6-4 Isotopic keff Bias (i) and Bias Uncertainty (ki) for the Representative PWR SNF System Model Using ENDF/B-V Data as a Function of Assembly Average Burnup............................................................................. 6-26 Table 6-5 Summary of Code Validation Recommendations for Isotopic Depletion......... 6-26 Table 6-6 Summary of Minor Actinide and Fission Product Code Validation Recommendations for keff Determination........................................................ 6-28 Table 6-7 Summary of Burnup Verification Recommendations...................................... 6-30 Table 6A-1 Recommended set of nuclides for actinide-only burnup credit........................ 6-39

xviii Table 6A-2 Recommended set of additional nuclides for actinide and fission product burnup credit.................................................................................................. 6-39 Table 6A-3 Isotopic keff bias uncertainty (ki) for the representative PWR SNF system model using ENDF/B-VII data (i = 0) as a function of assembly-average burnup...............................................................................6-56 Table 6A-4 Isotopic keff bias (i) and bias uncertainty (ki) for the representative PWR SNF system model using ENDF/B-V data as a function of assembly-average burnup.............................................................................. 6-56 Table 6A-5 Fission product reactivity worth for typical burnup in generic burnup credit cask (GBC-32) with 4 weight percent uranium-235 Westinghouse 17x17 OFA, burned to 40 GWd/MTU............................................................. 6-57 Table 7-1 Relationship of Regulations and Areas of Review for Transportation Packages......................................................................................................... 7-3 Table 8-1 Relationship of Regulations and Areas of Review for Transportation Packages......................................................................................................... 8-2 Table 9-1 Relationship of Regulations and Areas of Review for Transportation Packages......................................................................................................... 9-2

xix ABBREVIATIONS AND ACRONYMS ADAMS Agencywide Documents Access and Management System Ag silver AISC American Institute of Steel Construction ALARA as low as is reasonably achievable (radiation exposure)

Am americium ANL Argonne National Laboratory ANS American Nuclear Society ANSI American National Standards Institute ASNT American Society for Nondestructive Testing APSR axial power shaping rod ASME American Society of Mechanical Engineers ASTM American Society for Testing and Materials AWS American Welding Society AWRE Atomic Weapons Research Establishment B4C boron carbide B&PV Boiler and Pressure Vessel (ASME Code)

BPR burnable poison rod BPRA burnable poison rod assembly BWR boiling-water reactor CE Combustion Engineering CE-PWR Combustion Engineering System 80+ Pressurized-Water Reactor CFR Code of Federal Regulations c.g.

center of gravity CH4 methane CISCC chloride-induced stress corrosion cracking CMS computational modeling software CoC certificate of compliance CR control rod CRC commercial reactor critical Cs cesium CSI criticality safety index CVCM collected volatile condensable materials D

deuterium (chemical symbol)

D2 deuterium gas D2O deuterium oxide, heavy water DOE U.S. Department of Energy DOT U.S. Department of Transportation DSFM Division of Spent Fuel Management (NRC)

DT deuterium tritium DTO tritiated heavy water EALF energy of average neutron lethargy-causing fission EIA Energy Information Administration EPR ethylene propylene rubber EPRI Electric Power Research Institute Er erbium

xx Er2O3 erbium oxide Eu europium FG fuel grade GBC generic burnup credit cask GCI grid convergence index Gd gadolinium Gd2O3 gadolinium oxide GE General Electric H

hydrogen, protium (chemical symbol)

H2 hydrogen gas H2O water HD hydrogen deuteride HDO hydrogen-deuterium oxide HPS Health Physics Society HT tritium gas HTC Haut Taux de Combustion HTO tritiated water vapor, tritium oxide H/X hydrogen-to-fissile atom ratios IAEA International Atomic Energy Agency IBA integral burnable absorber ICRP International Commission on Radiological Protection IHECSBE International Handbook of Evaluated Criticality Safety Benchmark Experiments IN information notice (NRC)

INMM Institute for Nuclear Materials Management ISG interim staff guidance keff k effective-neutron multiplication factor or effective thermal conductivity LEU low-enriched uranium lfpm linear feet per minute LiAIO2 lithium aluminate LSA low specific activity LWR light-water reactor MMC metal matrix composite MNOP maximum normal operating pressure Mo molybdenum MOX mixed oxide N2 nitrogen gas NASA National Aeronautics and Space Administration Nd neodymium NDE nondestructive examination NDT nondestructive testing NFH nonfuel hardware NIST National Institute of Standards and Technology

xxi NMSS NRC Office of Nuclear Material Safety and Safeguards Np neptunium NRC U.S. Nuclear Regulatory Commission NRR Office of Nuclear Reactor Regulation (NRC)

NSA neutron-source assembly O

oxygen O2 oxygen gas OCRWM Office of Civilian Radioactive Waste Management OFA optimized fuel assembly ORNL Oak Ridge National Laboratory UO2 uranium dioxide PEEK polyetheretherketone PG power grade PNNL Pacific Northwest National Laboratory Pu plutonium PVC polyvinyl chloride PWR pressurized-water reactor QA quality assurance QAPD quality assurance program description QARD quality assurance requirements document RAC Respiratory Advisory Committee (DOE)

RAI request for additional information RAM radioactive material RCA radiochemical assay RES Office of Nuclear Regulatory Research (NRC)

RG regulatory guide (NRC)

Rh rhodium RIS regulatory issue summary RSICC Radiation Safety Information Computational Center Ru ruthenium SAR safety analysis report SBR styrene-butadiene SCO surface contaminated object SER safety evaluation report SFPO Spent Fuel Project Office (NRC)

SI International System of Units Sm samarium SNF spent nuclear fuel SRP standard review plan SRS Savannah River Site SSCs structures, systems, and components STP standard temperature and pressure T

tritium (chemical symbol)

T2 molecular tritium, tritium gas

xxii T2O tritium oxide Tc technetium TI transportation index TML total mass loss TPBARs Tritium-Producing Burnable Absorber Rods TVA Tennessee Valley Authority U

uranium UF6 uranium hexafluoride UO2 uranium dioxide UT ultrasonic testing WG weapons grade WREC Westinghouse Reactor Evaluation Center X/Q atmospheric dispersion

xxiii UNITS A/g Specific activity per gram atm atmosphere Bq Becquerel C

Celsius

°C degrees Celsius Ci curie Ci/cm3 curies per cubic centimeter Ci/liter curie per liter Ci/yr curies per year cm centimeter cm-1 per centimeter cm2 square centimeter cm3 cubic centimeter dpm/100 cm2 disintegrations per minute per 100 square centimeters eV electron volt F

Fahrenheit

°F degrees Fahrenheit ft foot ft2 square foot ft3 cubic foot g

gravitational unit gm gram GWd/MTU gigawatt days per metric ton uranium GWd/MTHM gigawatt days per metric ton of heavy metal Gy gray hr hour in.

inch K

Kelvin keV kilo electron volt kg kilogram km kilometer kPa kilopascal ksi thousand pounds per square inch L

liter lb pound m

meter m2 square meter m3 cubic meter

xxiv mb millibar mCi millicurie mCi/hr millicuries per hour mCi/m3 millicuries per cubic meter mCi/(TPBAR-hr) millicuries per TPBAR per hour MeV mega electron volt mg milligram (one-thousandth of a gram) mg/cm2 milligrams per square centimeter mi mile mJ millijoule ml milliliter mm millimeter (one-thousandth of a meter)

MPa megapascal (million pascals) mph miles per hour mrem millirem ms millisecond mSv millisievert MT metric ton MTHM metric tons of heavy metal MW megawatt MWd megawatt days MWd/MTU megawatt days per metric ton uranium MWd/MTHM megawatt days per metric ton of heavy metal N

newton nCi nanocurie Pa Pascal PBq petabecquerel ppm parts per million psf pounds per square foot psi pounds per square inch psig pounds per square inch gauge rad radiation-absorbed dose s

second Sv sievert Tbq terabecquerel Ci microcurie

µm micrometer W

watt wt%

weight percent yr year

xxv INTRODUCTION Purpose of the Standard Review Plan The Standard Review Plan for Transportation Package Approval (referred to herein as the SRP) provides guidance to the U.S. Nuclear Regulatory Commission (NRC) staff for reviewing applications for approval of package designs used for the transport of radioactive materials under Title 10 of the U.S. Code of Federal Regulations (10 CFR) Part 71. It is not intended as an interpretation of NRC regulations. Nothing contained in this SRP may be construed as having the force and effect of NRC regulations (except where the regulations are cited), or as indicating that applications supported by safety analyses and prepared in accordance with Regulatory Guide (RG) 7.9, Standard Format and Content of Part 71 Applications for Approval of Packages for Radioactive Material, will necessarily be approved, or as relieving any person from the requirements of 10 CFR Part 71 as well as other pertinent regulations, including but not limited to the following:

10 CFR Part 20, Standards for Protection Against Radiation 10 CFR Part 30, Rules of General Applicability to Domestic Licensing of Byproduct Material 10 CFR Part 40, Domestic Licensing of Source Material 10 CFR Part 60, Disposal of High-Level Radioactive Wastes in Geologic Repositories 10 CFR Part 70, Domestic Licensing of Special Nuclear Material Three major objectives of this SRP include the following:

summarize the regulatory requirements for package approval describe the procedure by which the staff determines that the requirements have been satisfied document the practices the NRC developed in previous package certifications This SRP complements RG 7.9, which provides guidance to applicants on the standard format and content of applications for package approval. Unless specified, all acceptance criteria and review guidance in this SRP is applicable to all packages. Appendix A, Description, Safety Features, and Areas of Review for Different Types of Radioactive Material Transportation Packages, to this SRP describes different types of packages for different types of contents and provides specific information on reviewing each package type. Note that Appendix A does not contain guidance specific to spent nuclear fuel packages.

Applicability This SRP provides guidance for the NRC staffs review and approval of certificates of compliance for packaging used to transport radioactive materials (RAM).

Appendix E, Description and Review Procedures for Irradiated Tritium-Producing Burnable Absorber Rods Packages, to this SRP provides supplemental general information and

xxvi guidance for reviewing applications for packaging used in the shipment of irradiated tritium-producing burnable absorber rods (TPBARs).

Organizational Structure The SRP is organized to correlate with the recommended content for an application, as detailed in RG 7.9, which will be revised in the future to harmonize with this SRP. The individual sections of each chapter address the matters that are reviewed, the basis for the review, how the review is accomplished, and the conclusions that are sought and follow a common outline of subsections, as described below. In conjunction with the SRP, the NRC staff developed several interim staff guidance (ISG) documents related to package approvals under 10 CFR Part 71.

An ISG addresses emergent review issues. This SRP combines and updates NUREG-1609, Standard Review Plan for Transportation Packages for Radioactive Material, issued September 1997, and NUREG-1617, Standard Review Plan for Transportation Packages for Spent Nuclear Fuel, issued March 2000, and their supplements and incorporates applicable ISGs, as shown in Table 1.

Table 1 Interim Staff Guidance (ISGs) Incorporated Into This Standard Review Plan ISG #

& Rev.

Title Affected Chapter(s)

ISG 1 Rev. 2 Damaged Fuel 2, 4, 5, 6, 7 ISG 6 Establishing Minimum Initial Enrichment for the Bounding Design Basis Fuel Assembly(s) 5 ISG 7 Potential Generic Issue Concerning Cask Heat Transfer in a Transportation Accident 3

ISG 8 Rev. 3 Burnup Credit in the Criticality Safety Analyses of PWR Spent Fuel in Transport and Storage Casks 6

ISG 11 Rev. 3 Cladding Considerations for the Transportation and Storage of Spent Fuel 7

ISG 15 Materials Evaluation 5, 6, 7 ISG 19 Moderator Exclusion Under Hypothetical Accident Conditions and Demonstrating Subcriticality of Spent Fuel Under the Requirements of 10 CFR 71.55(e) 1, 3, 6 ISG 20 Transportation Package Design Changes Authorized Under 10 CFR Part 71 Without Prior NRC Approval 1, 3, 5, 6, 8, 9 ISG 21 Use of Computational Modeling Software 2, 3 ISG 22 Potential Rod Splitting Due to Exposure to an Oxidizing Atmosphere During Short-Term Cask Loading Operations in LWR or Other Uranium Oxide Based Fuel 3, 8 ISG 23 Application of ASTM Standard Practice C1671-07 When Performing Technical Reviews of Spent Fuel Storage and Transportation Packaging Licensing Actions 3, 5, 6, 7, 9 Because of the large variety of packages and the many different approaches that can be taken to evaluate these package designs, no single review plan can address in detail every situation that might be applicable to a review. The staff may therefore need to modify or expand the guidance in this review plan to adapt to specific package designs. The following areas of 10 CFR Part 71 are not within the scope of this SRP:

xxvii Qualification and shipment of low-specific-activity material and surface-contaminated objects Qualification of special form radioactive material Reports, records, notifications, violations, and criminal penalties Exemptions and general licenses Requirements incorporated into 10 CFR Part 71 by reference to other regulations, (e.g.,10 CFR Parts 20, 21, 30, 40, 70, 73, and DOT or U.S. Postal Service regulations)

Technical Review Oversight Certificate holders are responsible for demonstrating that the package design meets the requirements in 10 CFR Part 71, Subparts D, Application for Package Approval, and E, Package Approval Standards, and performing the preliminary determination, as required by 10 CFR 71.85, Preliminary Determinations. Licensees are responsible for complying with the general license in accordance with 10 CFR 71.17, General License: NRC-Approved Package, for safe operation and for complying with appropriate regulations during shipment. The NRC mission as the regulator is to confirm that the package design provides adequate protection of public health and safety and the environment. The value of the NRC review team is its independent expertise in identifying and ensuring the resolution of potential design or operational deficiencies, analytical errors, nonconservatisms or significant uncertainties in novel design approaches, or other issues that hinder the NRCs ability to ensure compliance with the regulations. If otherwise left unchecked by the licensee and the regulator, these issues could potentially lead to the unsafe or noncompliant use of the package.

Several considerations may influence the depth and rigor that is needed for a reasonable assurance determination of both safety and compliance. These include, but are not limited to, the novelty of the design (as compared to existing designs), safety margins, operational experience, and defense-in-depth. Any aspect of the design or procedures that the NRC determines the certificate holder should not change, without prior NRC approval, should be placed as a condition in the certificate. The design is specified in the certificate of compliance (CoC) (by reference) with drawings, operating procedures, acceptance tests and maintenance programs, and with other relevant documentation as needed. The staff and applicant should ensure that the CoC conditions include the appropriate level of detail that could also allow for appropriate minor changes to the package but still be within the design specified in the CoC (e.g., tolerances that are bounding of variations that can be seen in package fabrication).

Review Process The reviews of the application are performed by reviewers with expertise in the technical areas described in this SRP. Because of the dependence between technical information in different sections of the application, coordination among the different disciplines is important to ensure a consistent, uniform, and high-quality review. As shown in the flow charts contained in each chapter of this SRP, technical issues are interwoven among the disciplines, and many rely on input from multiple areas.

When reviewing an amendment to a package design, the staff should consult the SERs of previous amendments, if applicable, as well as the SERs for similar, approved packages to

xxviii understand past NRC determinations regarding analyses affecting or similar to those in the application under review. In conducting reviews, the staff should confirm that the application properly applies NRC regulatory guidance, when endorsed by reference. While applicants are not required to comply with NRC guidance, the use of NRC guidance facilitates the staffs review process in evaluating package designs and confirming compliance with NRC regulations.

For amendments, the staff should review the entire amendment to ensure that the applicant has identified all the changes to the certificate of compliance. Amendments may range from minor changes in the design, contents, or operations to adding new major component designs or contents. Some amendments are based upon the design and methodologies the NRC previously reviewed for that package. Evaluations of amendment changes are often based on the performance of the package as an integrated system. As a result, the staff may reexamine portions of previously approved components, contents, or methodologies in the application to ensure that the design and operations, as modified under the amendment proposal, meet 10 CFR Part 71 requirements. During the audit review of an amendment, the staff may occasionally find errors or other safety questions that affect part of the previously approved design. The staff may need to review that part of the application and ask questions to assure the design remains safe and compliant with applicable regulations. The questions should be limited to understanding and resolving the specific technical issue and should consider past precedents, regulatory guidance, and risk significance, as appropriate. The staff should also consider other processes (e.g., inspections, enforcement actions, generic issue program) to resolve these types of potential safety questions with a previously approved design.

If the information provided in the application is not properly justified, the reviewer may develop and then forward to the applicant questions requesting clarification of technical issues via a request for additional information (RAI). The staff should review the applicants response to the RAI, together with a supplemented application, for acceptability. The RAI process is repeated, as necessary, until the applicant demonstrates that the package design meets 10 CFR Part 71, or until the NRC terminates the application review or the applicant withdraws the application.

Safety Evaluation Report and Content The NRC staff documents the results of an application review in a safety evaluation report (SER). Although the NRC Project Manager for the review will make the final determination of the organization of an SER, the SER typically is organized in the same manner as this SRP and contains the following information:

a general description of the package, including the design and operational features, and content specifications a summary of the approach the applicant used to demonstrate compliance with the regulations, and a description of the reviews that the staff performed to confirm compliance comparison of systems, components, analyses, data, or other information important in the review analysis to the acceptance criteria, in addition to staff conclusions (including the bases for those conclusions) regarding the acceptability, suitability, or appropriateness of this information to provide reasonable assurance the acceptance criteria have been met

xxix summary of aspects of the review that were selected or emphasized, aspects of the design or contents that were modified by the applicant, aspects of the design that deviated from the criteria stated in the SRP, and the bases for any deviations from the SRP summary statements for evaluation findings at the end of each chapter Content of this Standard Review Plan Each chapter of the SRP is organized into the following sections:

Review Objective Areas of Review Regulatory Requirements and Acceptance Criteria Review Procedures Evaluation Findings References Review Objective This section provides the purpose and scope of the review and establishes the major review objectives for the chapter. The reviewer should obtain reasonable assurance during the review that the objectives are met.

Areas of Review This section lists the areas of review. Each area of review encompasses systems, components, analyses, data, or other information and provides the organizational structure for the rest of the chapter.

Regulatory Requirements and Acceptance Criteria The regulatory requirements portion of this section summarizes the regulatory requirements for 10 CFR Part 71 pertaining to the given chapter and can also list other significant regulatory requirements, such as those for 49 CFR Part 173, ShippersGeneral Requirements for Shipments and Packagings. This list is not all-inclusive, and the reviewer should refer to the regulations to ensure all relevant requirements are addressed in the application.

This subsection includes the regulatory requirements by reference and identifies other criteria to demonstrate that the package meets the regulatory requirements in 10 CFR Part 71 that apply to the given chapter. In most chapters, the acceptance criteria are organized similar to the review areas established in the Areas of Review section of the specific chapter and identify the type and level of information that should be in the application.

This section typically sets forth the solutions and approaches that staff reviewers have previously determined to be acceptable for demonstration of compliance with the regulations and addressing specific safety concerns or design areas that are important to safety. These solutions and approaches are discussed in this SRP so that the reviewers can implement consistent and well-understood positions as similar safety issues arise in future cases. These solutions and approaches are acceptable to the staff, but they are not the only possible method for meeting the regulations.

Substantial staff time and effort has gone into developing these acceptance criteria.

Consequently, a corresponding amount of time and effort may be required to review and accept new or different solutions and approaches. Thus, applicants proposing new solutions and approaches to safety issues or analytical techniques other than those described in the SRP may

xxx experience longer review times. An alternative for the applicant is to propose new methods on a generic basis, apart from a CoC. Such an alternative proposal could consist of a submittal of a topical report.

Review Procedures This section presents a general approach that reviewers typically follow to establish reasonable assurance that the applicable acceptance criteria have been met. As an aid to the reviewer, this section may also provide information on what has been found acceptable in past reviews. This section identifies standards that have been found acceptable in particular reviews, or that are desirable but not specifically identified in existing regulatory documents. Since many reviews of applications are interdisciplinary, the reviewers should coordinate with each other, as necessary, to identify issues in other chapters. The section includes a flow chart figure to depict the coordination that may be necessary to conduct reviews.

In addition, the reviewer may provide discussions on conditions of the approval. In these cases, the reviewer should include a discussion of each condition and the reasons for the addition of the condition in the relevant sections of the SER.

Evaluation Findings This section provides example evaluation findings and summary statements to be incorporated into the SER. The reviewer prepares the evaluation findings based on the applicants satisfaction of the regulatory requirements. The findings are published in the SER.

References This section lists the NRC documents, codes, specifications, standards, regulations, and other technical documents referenced in the chapter.