ND-20-0642, ITAAC Closure Notification on Completion of 3.2.00.04 (Index Number 751)

From kanterella
(Redirected from ML20342A200)
Jump to navigation Jump to search
ITAAC Closure Notification on Completion of 3.2.00.04 (Index Number 751)
ML20342A200
Person / Time
Site: Vogtle 
Issue date: 12/04/2020
From: Yox M
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
ND-20-0642
Download: ML20342A200 (6)


Text

Southern Nuclear Michael J, Yox Regulatory Affairs Director Vogtle 3 & 4 7825 River Road Waynesboro, GA 30830 706-848-6459 tel December 4, 2020 Docket Nos.: 52-025 ND-20-0642 10CFR 52.99(c)(1)

U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 ITAAC Closure Notification on Completion of 3.2.00.04 (Index Number 7511 Ladies and Gentlemen; In accordance with 10 CFR 52.99(c)(1), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) of the completion of Vogtle Electric Generating Plant (VEGP) Unit 3 Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 3.2.00.04 [Index Number 751]. This ITAAC confirms human-system interface resources are available to the main control room operators. The closure process for this ITAAC is based on the guidance described in Nuclear Energy Institute (NEI) 08-01, "Industry Guideline for the ITAAC Closure Process under 10 CFR Part 52," which was endorsed by the NRC in Regulatory Guide 1.215.

This letter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) requests NRC staff confirmation of this determination and publication of the required notice in the Federal Register per 10 CFR 52.99.

If there are any questions, please contact Tom Petrak at 706-848-1575.

Respectfully submitted.

,UCH'WX1 0 V Michael J. Yox Regulatory Affairs Director Vogtle 3 & 4

Enclosure:

MJY/RAS/sfr Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 3.2.00.04 [Index Number 751]

U.S. Nuclear Regulatory Commission ND-20-0642 Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. Peter P. Sena III (w/o enclosures)

Mr. D. L. McKinney (w/o enclosures)

Mr. M. D. Meier (w/o enclosures)

Mr. G. Chick Mr. S. Stimac Mr. P. Martino Mr. M. J. Yox Mr. A. S. Parton Ms. K. A. Roberts Mr. T. G. Petrak Mr. C. T. Defnall Mr. C. E. Morrow Mr. R. L. Beiike Mr. S. Leighty Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc:

Nuclear Regulatory Commission Ms. M. Bailey (w/o enclosures)

Mr. M. King Mr. H. K. Nieh Mr. C. P. Patel Mr. G. J. Khouri Mr. C. J. Even Mr. B. J. Kemker Ms. N. C. Coovert M

M M

M M

M M

M M

M M

M M

M C. Welch J. Gaslevic O. Lopez-Santiago G. Armstrong M. Webb T. Fredette C. Santos

s. M. Bailey B. Davis J. Vasquez J. Eargle E. Davidson T. Fanelli S. Rose Ms. K. McCurry

U.S. Nuclear Regulatory Commission ND-20-0642 Page 3 of 3 Oqlethorpe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. 8. M. Jackson Daiton Utilities Mr. T. Bundros Westinqhouse Electric Company. LLC Dr. L. Oriani (w/o enclosures)

Mr. D. 0. Durham (w/o enclosures)

Mr. M. M. Corletti Mr. Z. 8. Harper Mr. J. L. Coward Other Mr. 8. W. Kline, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., CDS Associates, Inc.

Mr. 8. Roetger, Georgia Public Service Commission Mr. R. L. Trokey, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Batch Bingham

U.S. Nuclear Regulatory Commission ND-20-0642 Enclosure Page 1 of 3 Southern Nuclear Operating Company ND-20-0642 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 3.2.00.04 [Index Number 751]

U.S. Nuclear Regulatory Commission ND-20-0642 Enclosure Page 2 of 3 Design Commitment

4. The HSI resources available to the MCR operators include the alarm system, plant information system (nonsafety-related displays), wall panel information system, nonsafety-related controls (soft and dedicated), and computerized procedure system.

Inspections/Tests/Analvses An inspection of the HSI resources available in the MCR for the MCR operators will be performed.

Acceptance Criteria The HSI (at the time of plant startup) includes an alarm system, plant information system (nonsafety-related displays), wall panel information system, nonsafety-related controls (soft and dedicated), and computerized procedure system.

ITAAC Determination Basis An inspection of the Human-System Interface (HSI) resources available in the Main Control Room (MCR) for the MCR operators was performed to verify that the HSI (at the time of plant startup) includes an alarm system, plant information system (nonsafety-related displays), wall panel information system, nonsafety-related controls (soft and dedicated), and computerized procedure system.

The inspection of the HSI resources discussed above was performed per ITAAC Technical Report (ITR) SV3-HSI-ITR-800751 (Reference 1) to confirm that the HSI resources available in the MCR for the MCR operators at the time of plant startup include an alarm system, plant information system (nonsafety-related displays), wall panel information system, nonsafety-related controls (soft and dedicated), and computerized procedure system.

The results of the inspection are documented in the ITR and confirm that the HSI resources available in the MCR for the MCR operators at the time of plant startup include an alarm system, plant information system (nonsafety-related displays), wall panel information system, nonsafety-related controls (soft and dedicated), and computerized procedure system. This report is available for NRC inspection as part of the ITAAC Completion Package (Reference 2).

ITAAC Finding Review In accordance with plant procedures for ITAAC completion. Southern Nuclear Operating Company (SNC) performed a review of all findings pertaining to the subject ITAAC and associated corrective actions. This review found there were no relevant ITAAC findings associated with this ITAAC. The ITAAC completion review is documented in the ITAAC Completion Package for ITAAC 3.2.00.04 (Reference 2) and is available for NRC review.

U.S. Nuclear Regulatory Commission ND-20-0642 Enclosure Page 3 of 3 ITAAC Completion Statement Based on the above information, SNC hereby notifies the NRG that ITAAC 3.2.00.04 was performed for VEGP Unit 3 and that the prescribed acceptance criteria are met.

Systems, structures, and components verified as part of this ITAAC are being maintained in their as-designed, ITAAC compliant condition in accordance with approved plant programs and procedures.

References favailable for NRG inspection)

1. SV3-HSi-iTR-800751, Revision Number 0, HFE Human Systems interface_Resources Available (ITAAC# 3.2.00.04)
2. 3.2.00.04-U3-CP-Rev0, ITAAC Completion Package