5 to Updated Final Safety Analysis Report, Chapter 7, Drawing 445291, Rev. 28, Sheet 1, Electrical Single Line Meter 12V Instrument AC System
ML20268B134
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 06/30/2020
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20268B299 List: ... further results
References
DCL-20-075
Download: ML20268B134 (1)


Text

{{#Wiki_filter:OLD4 CUTLINE E FOLD D C FOLD B o A N CX) C sr Ol o u

  • C al 0 o,+-

'U 0 .o 'o o, _ N N ' <( "1- - ,;;;;r CJ) ** SJ"N L II LC1 (]) o:: sr '1J w sr :::J f- " VlZD <( 0<( 0:: OU 4NPG 4 size I I 6ZSvv 2 3 4 5 C' 0: 6 7 480V MCC BUS" IH" (REF 6) 480V MCC BUS "I G" ( REF

12) 125V DC DISTRIBUTION PANEL NO.

13 (REF 5) 72-131 I .,.....,,_;2;;.;5;.;;0'-<l,,.-----,_o--* 250 IOO )52-IH-77 70 _!_QQ l) 52-1 H-56 70 H77POOB 3- 0 2 ,------------------------------------------------------------------------1 , i,-- H56POOA 2-*2 (A0,C0) -AV2927D I 3- 0 12 r----- ---- N A SBOI l I Ii I IY/frl _I >-----j V NUCLEAR ,,---,I C":\\ I I INSTRUMENT V Q \\Xl9j""\\X20,-.....,1,....,_. ____ ~ UPS 13 '--_, \\~*LVJJ/ ~~ ~J I 2P ) 10, 20KVA B4 I IYl3 SWITCH I X404 INVERTER B401 I


0 STATIC SWITCH 2P I

I I I 225A '0 I A I, V F II MANUAL BYPASS T I SWITCH B2 11 250A B801 7 I_ - - - - - - - - - ~ ~300Y00,300YOOA 4- 0 2/0 IOO )52-IG-37 70 J i,--G37POOA 2-*2 (A0,B0) NUCLEAR INSTRUMENT REGULATING TRANSFORMER 13 10,20KVA TRYl3 SDl3 3~ ~--0,,.-----,_0-"i[l;:::;}r17 -~o-~l---1*-----------------------------------, 3P F407 F2 F204 2P I L300YO 1 -31 ID 2-350kcmi I I 4 0 0 A r----"'-----, X 6 BOA ~jg~ RECTIFIER 600A ~-1-~ 600A e IOOA 2-*I/O BI XDCR2 XDCRI <;)7 XDCR4 XDCR3 XI 7 X204 B3 I I ,......----..._~ I '----------------i.l--o2Po-XI O ~ --o 2Po- '.:+-'I~ I 350A J Xl 5 IOOA I I X4 X 16 I i,-- 300Y02 NIS CHAN I I I CAB "C" CONT PWR RNIC RACK NU PROT SET 3 CUB 'A RNP3A BAT 1-1 MISC INSTR PM-117 RACK NU SFGD INPUT 'A' RNS I A DEMIN & MU WTR CONT INSTR BUS CONT CONSOLE CC2 I Xl3 I 2- 0 1/0 I /x9\\ I I ~ VI YI 3DCA YI YI 3DCA _l_ VI YI 3ACA YI YI 3ACA I I COMPUTER COMPUTER XI 8 COMPUTER COMPUTER I I I I _________________________________________________________________________ I FU-1311 l~I 1~ 2 FU-1312 2-*10 2-*10 -=---------'---------IIII =:Ill f----------0

0---------1..__--o_

I I FU-1313 1~ 3 1~ 4 FU-1314 2-*8 2-*10 --=--~-l[II =:Ill f----------0 I I 2 *IO FU-1315 l~S 1~ 6 FU-1316 ~~____:_:IITI :'.::JJI f----------0 0---------1..__--o o-----------rr: 2 o IO FU-131 7 1~ 7 1~ 8 FU-1318 2 o I 0 ~~____:_:IITI :'.::JJI f----------0 I I 2 *10 FU-1319 1~ 9 ~~O FU-1320 2 *10 ~.::_c_~-----{l[l:=JJlf----------0 ~o---.---0 I I NIS CHAN Ill CAB"C INSTR PWR RNIC RACK NU CONT SET 3 CUB B RN03B SPARE RACK NU SFGD INPUT "B" RNSIB

eves, INSTR BUS CONT BD CNV FU-1321 1E 1 1322 FU-1322

-~ 2 *10 STM GEN 10% ATM INST I 3A I I I 3A 12 2-*10 FU-13AII ~ ~ FU-13Al2 2-*12 MON LT BOX BT H I I OX ---------<[C))>------00--

-.----0 0>-------,[C))>-------

1 3A I 3 I 3A 14 MAIN CONT BD STATUS L TS 2-" IO FU-I 3A 13 ~ ~ FU-I 3A 14 CH IV & ERFDS CNCS [CJ] o o [C))f----- 1 3A I 5 I 3A 16 2 *8 FU-13Al5 ~ ~ FU-13Al6 RAD MON PNL RNRMS2 --------l[C))f----0 o [C))f----- 1 3A I 7 I 3A 18 FU-13Al7 ~ ~ FU-13Al8 SPARE -------l[C))f----0 0 [C))f----- 13 A I 9 13A20 FU-13Al9 ~ ~ FU-13A20


i[C))>------0 0

rr=Il>----- SPARE l 3A 2 I 13A22 NEUTRON FLUX AMPLIFIER AND PROCESSOR XNM52,XNM54 SPARE SPARE SPARE SPARE SPARE RHR PP 1-2 FLOW CONT LOGIC PM75A rr::::::Il----- ~0---.---0 I H I C 5 I 6 & H I C 5 2 6 2-*12 FU-1323 1~ 3 1~ 4 FU-1324 HOI RAD MON RACKS 2-* IO FU82 I 0~_ ~ FUciA22 2-* IO'

RNRMA, RNARB, RNARE 13A23 13A24

,FIRE ALARM CONT FU-13A23 ~ ~ FU-I 3A24 I-* 1 o PNL POFA, POFB, POFD AUX FW I I, 12 INSTR HIC 70,71, till.! RWST LVL AUX RLYS PIC SFGD VENT LOGIC CABINET P0V2 SEISMIC ORTHOGONAL TRIGGERS ENST3A ERFDS & POST ACCIDENT MON RACK RPAMl,2,4 .'.:___'._'.:___----jlII =:Ill f----------0 o-----------rr: s P A R E FU-1325 I E.5 I ~ 6 FU-1326 131!iR 12E RCP -=-2-=--=-*_,_1 o~----tcJ:l ~ ' 1-3 LEAKAGE PRESS INST-PEN PROT-FIT-157 II lf----------0 :;I - 32o-----------rr: 8 ~ 1_, 10 RCP 1-3 LEAKAGE PRESS INST-B/U PEN PROT-FIT-157 Fu -1327 1:3.7 FU 1328 .=_2_::_.::_*_,_1 0~--{l[I =:Ill f--------0 :: ~ - 1 2 *IO B/U A IR SPL Y I 0% STM DUMP 1 329 1-330 SG I -2 SV526E, F, G & H PM307 2-*12 FU-1329 ~ ~ FU-1330 2-*10 SEISMIC INSTR -=-------'---='------!III =:Ill f----------0 1 R A C K R S I FU-1331 I~ I I :22 FU-1332 TRANS SW EJPBZ FOR .::_2 _-* __ l'...:0'----((=:IJ ';..__--{CTI-------':2=--------*_,_1.::_2 CON T RM VENT I SOL AUX 11 I f----------0 I I RL YS & PZR SAFETY RV 2 _. 12 FU-1333 1~ 3 1~ 4 FU-1334 2 _. 12 MONITOR POMI (OWG 433130) ---=------'-'=---{I [I =:Ill f----------0 1 1 PO S T A C C I D E N T P N L S RCHMC & POPLS2 AND RVLIS PNL PM79 SPARE PEN PROT BILI: I 3SPR* : BKR I 0~ I 3A I '27 1YPYl3 L _____ ] .------rr::::n-~-.._----{ w FU-01 PANEL 13 INSTR AC DISTR CHAN I II PYl3 10, 2 WIRE, 120V ( ALL BKRS ARE 20A, IP EXCEPT AS SHOWN. ALL FUSES ARE 30A EXCEPT AS SHOWN. )

  • NOTE:

I 3SPR IS A SPARE BKR FOR FUTURE PENETRATION REDUNDANCY, IT IS NOT CONNECTED ELECTRICALLY TO THE PANEL BUS. SPARE AUX RELAY RACK "A" RNA RA SPARE SPARE SPARE


<[C))>------0 ::

Q>-------,[C))f----- 1 3A25 I 3A26 2-*10 FU-13A25 ~ ~ FU-13A26 2-*10


l[C))>------0 ::

Q>-------,[C))f----- 1 3A27 I 3A28 FU-13A27 ~ ~ FU-13A28 2-*12


<[C))>------0 ::

0 rr=Il>------- 1 3A29 I 3A30 FU-I 3A29 ~ ~ FU-I 3A30


<[C))>------0 "'

0 rr=Il>----- 13A31 13A32 FU-13A31 ~ ~ FU-13A32


<[C))>------0 0

rr=II>----- 27 3A 1 y I t-----rr=n----------< w FU-01 PANEL 13A INSTR AC DISTR CHAN 11 I PYl3A 10, 2 WIRE, 120V ( ALL BKR' S ARE 20A, IP EXCEPT AS SHOWN) ALL FUSES ARE 30A, EXCEPT AS SHOWN) GEN RLY BD RG TRANS SW EJPB FOR CONT RM VENT !SOL AUX RLYS & PZR SAFETY RV MONITOR POM2 IU-2 B/U SPLY-DWG 433130) SPARE (SEE NOTE 2) SPARE KEY DWG. SECTION DATE 04-18-2019 D,D, IAZI R. E. RXG2 I. V. NIA P. E. NIA 9 C' a' 8 0' TABLE OF DEVICES DEVICE DESCRIPTION Xl2 UPS COMMON ALARM X7 OUT OF SYNC/COMMON ALARM X13 UPS FAN FAILURE/COMMON ALARM XIS UPS OVER TEMP/COMMON ALARM Xl9 REG XFMR OVER TEMP/COM ALM X20 REG XFMR FAN FAILURE/COM ALM X203 LOSS OF BYPASS SOURCE/COM ALM X404 AC INPUT/RECTIFIER FAIL/COM ALM X4 DC INPUT UNDERVOLTAGE RELAY XG INVERTER OUTPUT UNDERVOLTAGE RELAY X9 LOSS OF BATTERY SOURCE ALARM XIO INVERTER FAILURE ALARM Xl5 LOSS OF AC OUTPUT VOLTAGE ALARM X16 STATIC SW TRANSFERRED ALARM Xl7 MAN BYP SW IN BYPASS POS ALARM X204 AC OUTPUT UNDERVOLTAGE RELAY 27PYl3 PYl3 UNDERVOLTAGE ALARM 27PYl3A PYl3A UNDERVOLTAGE ALARM XDCRI DC INPUT CURRENT TRANSDUCER XDCR2 DC INPUT VOLTAGE TRANSDUCER XDCR3 AC OUTPUT CURRENT TRANSDUCER XDCR4 AC OUTPUT VOLTAGE TRANSDUCER CATALOG/TYPE P&B - TYPE CSJ MODEL 38-70010 P&B - TYPE CSJ MODEL 38-70010 RJS: 0 - 50mV DC RI S: 0 - I 50VDC RJS: 0 5 AAC RJS: 0 - 130VAC 72-1 3B I DC INPUT BREAKER G. E. TYPE T JK, 350A 52-l 3B2 AC OUTPUT BREAKER G.E. TYPE THEDl24100, IOOA 52-l 3B3 AC OUTPUT BREAKER G.E. TYPE THED124100, IOOA CONTACT LATCH NON-LATCH LATCH LATCH 10 REMARKS COMMON ALARMS FOR X7, X13, XIS, X19, X20, X203 & X404 CONTACT CLOSES TO ENERGIZE Xl2 CONTACT CLOSES TO ENERGIZE X12 CONTACT CLOSES TO ENERGIZE X12 LATCH CONTACT CLOSES TO ENERGIZE Xl2 LATCH CONTACT CLOSES TO ENERGIZE Xl2 NON-LATCH CONTACT CLOSES TO ENERGIZE X12 NON-LATCH CONTACT CLOSES TO ENERGIZE X12 NON-LATCH CONTACT CLOSES TO ENERGIZE X9 NON-LATCH CONTACT CLOSES TO ENERGIZE XIO LATCH N. C. CONTACT OPENS TO ALARM LATCH N. Co - CONTACT OPENS TO ALARM LATCH N.Co - CONTACT IN SERIES WITH X204 LATCH N.C. - CONTACT IN SERIES WITH X17 NON-LATCH N.O. - CONTACT IN SERIES WITH Xl6 NON-LATCH N.O. - CONTACT IN SERIES WITH Xl5 NON-LATCH N.C. - CONTACT CLOSES TO ALARM NON-LATCH N.C. - CONTACT CLOSES TO ALARM 52-13B4 BYPASS SOURCE DISC SWITCH G.E. TYPE TOD, 225A 1-------+------------------1------'-----,-~--+------1--------------1------ 52-I 3B401 AC INPUT BREAKER G.E. TYPE THED,(90A) 52-13B80 I REG XFMR OUTPUT BREAKER C.H. TYPE HJD, 250A 29-13S801 REG XFMR TRANSFER SWITCH 600VAC, 75A, 3PDT BREAK-BEFORE-MAKE SWITCH F2 F204 F407 F408 F409 IC INVERTER FUSE 250VAC, 600A SEE DWG 066144 STATIC SWITCH FUSE 250VAC, 600A SEE DWG 066144 RECTIFIER FUSE 250VAC, 400A SEE DWG 066144 RECTIFIER FUSE 250VAC, 400A SEE DWG 066144 RECTIFIER FUSE 250VAC, 400A SEE DWG 066144 LEGEND 0 METER 0 ALARM RELAY BOARD lxocR1I TRANSDUCER [CJ] FUSE VIYl3DCA PLANT COMPUTER COMPUTER INPUT NO. NOTE: I. DELETED

2. 52-PYl3A30 IS DEDICATED FOR UNIT I SAFETY PARAMETER SYS COMPUTERS 11

& 12 (SEE 445292, CIRCUIT 3A30Y00). REFERENCES DWG NO. I. SINGLE LINE METER & RELAY DIAG INSTR AC SH 0 1 --------- 437547

2. SINGLE LINE METER & RELAY DIAG INSTR AC SH *2--------- 437549
3. SINGLE LINE METER & RELAY DIAG INSTR AC SH 0 3--------- 445290
4. SINGLE LINE METER & RELAY DIAG INSTR AC SH 0 5 --------- 445294
5. SINGLE LINE METER & RELAY DIAG 125V DC SYSTEM--------- 445076 6, SINGLE LINE METER & RELAY DIAG 480V SYSTEM BUS SECT I H ---

437543

7. SCHEMATIC DIAG-120V INSTR AC SYSTEM--------------- 4010036
8. SCI 20KVA UPS & REGULATING TRANSFORMER------------- 6013738
9.

INSTR AC DISTR PNLS---------------------------66334 I

10. ONE LINE VENDOR DIAGRAM FOR PANEL PYl3------------- 6021760-123
11. LIST OF ELECTRICAL DEVICES ----------------------050024 12, SINGLE LINE METER & RELAY DIAG 480V SYSTEM BUS SECT IG--- 437542
13. ONE LINE VENDOR DIAGRAM FOR PANEL PYl3A-------------6021760-129 UNIT I REVISION DESCRIPTION DWG SCALE:

Revised Per DFT-7*4789 ELECTRICAL SINGLE LINE METER AND RELAY DIAGRAM BILL OF MATL: 120V INSTRUMENT AC SYSTEM DIABLO CANYON POWER PLANT PACIFIC GAS AND ELECTRIC COMPANY SAN FRANCISCO, CALIFORNIA SUPSOS: SUPSD BY: DRAWi NG SHEET 445291 PAGE REV 0 28 ~ FOLD z ~ - i O"> ~N C <{) sr sr OLD4 cu,}}