ML20268B110
Text
OLD4 CUTLINE E
FOLD D
C FOLD B
co
~ A
<!)
C sr Ol o
u 00
- C a, 0 o,+-
'U 0
.o
'o
,-,-, _ N
<!)
I <{
r--_LL rt')IV") 00 V<!J L II I"'-
Q) 0:: r<) (/)
w " ::J f---
VlZO
<( C)<(
0:: OU "f,50 V M,C,C, /3US SECT. t2J
,4_;.; ______
e,---t--.---
c----+--f----
2 3
MANUAL CONT~L /NO/CATION Sf'ZJ CM I -
X/-<~>--<f-//,._ ____..-_______________ -..-_ __,1---.
C 4c-/2J-I
/3 CS/ST/./Q" G
4 5
C' 0:
6
,';lART
(§)
7
-lf-A
-If-a C'
a' 8
0' X
X THIS DWG-X THIS Dv.G.
, 42-l2I-3S cs A_ 1-2-12,./-I CS//l~LJT, SW.7 UScD AT LOCATION CM 1
SPRING RETURN TO NEU7. !=ROM START
,;2-t2J-I : =
49-12,1-/
OL SPeJ
+2-12*/
VACUUM Or f'RESSURE
..5£L£C1 0-PUSH Of-'EJ2A10l2 CQ>JfACTS
--, I-A
-ii-- P;
--,1-C
-ii-D VACUUM R.t llf.f llGL. 0£P, X
X X
P0.5/flON,5 REL.
DEP.
Ptl. E 5 Slli<c 11.Ell<=F REL.
f)£P.
X X
X R6MARK5 1HIS owr...
1H15 OWG SP2J I
1 CONTROL SWITCH FCV,;:;i;3, r;,.,4 cs A
MP2J/
8 C
USED AT LOCATION CM k"'LOSE", OP-EN !
(§)
CONTACTS.._P_O_S~I_T_I_O~N_S--'
FCV 679 661 CLOSE NEU"/: OPEN
-II-A X
X THIS DIO!i
-ii-6 X
SPARE.
THIS DIO!i 120 V AC CONTROL SCHEMATIC CONTAINMENT PURGE SUPPLY FAN S3 CIRCIJ!T N9 2JO/POO
-~=====================================================~
CONTAINMENT PURGE l::.XHAUST FAN E3 SIMILAR EXCEPT AS SHOWN IN TABLE CIRCUIT ALA/'lM CK.T. ~
SPRIN"> f?ET/JllN TO NEUT/?/tl Fi<OM OPE.).;
(ISED AT lOC.
-II-C
-I I-D X
-II-F
-II-G X
-II-H DESCfi./PT ION J;l',Cf!QR.
- lOC, MOTOI'.. CIR.CU/T 8REA/iEI\\
/3US.
seer C.OMPIJTl/!.C{T,Nt,._f----__
ca_m~-,.,,_r._._r_11,_'l1/4_E_S~YS_7'._c._M __ ~---,
ALARM euWN!NG Clf'.CU/7 CONT.ACT /ill: f.
CONTROL. SWITCH COM"MT: PlffeGE SUPf'LY FAI-I $3 C1JNTMT, Pl)K.GE EXHAUST /WI E3 OPEN FCV679 CONT'MT
!SOL MPZ.JI 5e-t2J-('J/
IZJ e.Jolfoo
- 12. I 21351'00 OUTSIDE CONTAINMENT OPEN FCV681 INDICATION AND MONITOR LIGHT CONT
( REF I I l AlZ'l740 C'(/0441>
CYI045D AF!i'l'f'lO 42.X*/Z[-35 71-Ml 1
OUTSIDE COIJTA/NMcAJT
/A/SIDE: CONTAIAIMl::IJT 0/ffS/DE COAITAINMENT OPEN FuV66t co1Jr'Mr vt!JT' 1No1cA Ttow 4 FN rcv66o coNr'Mr veNT 11101c1tr1ox oPEIJ FCV664 coNT'M T IOPl:N FCV663 P/1Rt;E. 61/PPLI IISOLAT/0/J MONITOR Lt<i-HT RGE-&IPPL Y /SOLATIO!J
,e MO!IITOR VAC/1111,11 R/3J.IE, VHJT PRESS RELIEF /NO!CBT/0~ MO/JI TOR LIGHT CO/JTAC TS
~CNOTE 21 lcO!JTACT(//EF 11)1 ~
1 Lr CO!IT I
ISOLAT!uN1
{I/EF
/I) 5A
---a:::::n---o-P I - I I
CNAC CM 8
~~ :$
~;~2:)
(RE/://)
~--'----1-----~ TO ERFlJS
~Pl*/~~ n r
--fi.i-o-P,-2-:<>:---((
l~"'-, Qi
... Mll¥0~-25-4 CNAC t;;f!1.. Bl I
Cl/AC Qt. e,'
l CNAC lD LL w
0::
0 lD N
0 z I-u u
0 lD N
FCV679,661.L CS/OPENI 8 A'f oCM
,.L FCV679, 661 AI CS/NEUT*
OPEN CTCM El 1 RNSOB 606-9
,.LFCV679,661
- r CS/OPEN CM G
R TO ERFDS{-
',L MUX06-24* I ~M
'fr:
CM L 3G-3R I - I 7 - K622 606-I 0
, RNSOB E2 1-2 XPOS I 159 >- 3G-XPO; I 176 >- :1XPO~I 159 cna:i wr-wr--
o-,co I{') I.Cl r-- r.c r-- w IJ) (0
~->
~->
_,__U
u
---u
-U XPOSI 159 XPOS I I 76
- _21
~
~ ~
~ "'
-1~~ D~;:;~
a.. a..
a.. a..
PMl23>--I-I o
f-2-PMl84 XPOSI 176 XPOSI 159
_i V') LL
_/
V'l LL V) LL f./') LL A a, A o, B o, B o'-
a... a..
a.. a..
a... _J a.. _J 0
O u
U o--- NI - I-XPOS I I 59 XPOSI 176 XPOSI 159 o 8TH I IO o I
I 3W2 SV312 FCV679 7SV314 NI-I i
XPOSI 159 POSI 159 FCV661 PMI 23,o----- NI -I ---~e>----~
3WI XPOS I I 76i POS I I 76 CL/FCV679I D XPOS I I 76 I E5-I DI CL/FCV66 I I XPOS I 159 E5-2 PMl84 NI - I 6 BTH I IO 6 FCVG61 I
I TO EPFf)S Pt-I TO ERF.0S l-j BTI/IIO 9 BTH/10
- ~ l/3 A _tIC5/%f1
Mt/%0{;-23-2 ;~yi:e~ -~ B A+z~:f R/JS B 606*7 (R
~
'3W/
3~2 A!
c~
G R I AI ci,, ! R KG22!,'
,K
~L ix%1126 jXPf!1,,z4-
-1 C/.1
,,or:,="'
~---=--1--.,, J fi'J/5¢8 3/!Z-JR/
POSl/2£ p¢Sl/24 EI
'f~L M,v !
E;3 f ~Ml J
xPq>S/1240
?XP¢51!26 DtCL/FCVot.4-T,;t-/FLV~6.3 1*3
?,"'-5 CM CA'/0-'
EI l
'SI-1 F<2" I
L PIPSl/c4 -a
]e,,~s11Z6 XHS//26 l;<P¢1l24
{,()6*5 Lt*
~
CM 'f' Cl/fCVtr:!,
CL/FCVU1 ---
1 '-'--'~~
K622a e 3()-
3R
~
BTG26£ ' f(NS!tA ~-6 3li i ll; fe, XP@S!ll,:<.,~ !IJ*I Xff51126 E5-/
, :::a !
JxP¢s;,31
~
BTt26E
-£~
. tJG2r.E~-
~
I I___ i
/-/
- ~
jXPJSIIIB I
,3T6Z6E~
Cl
. - CV66J,66.4.l.
.c,JCV6{3,tlf r
,!, BTHl/0 o_B,,,_,TH:.:..11:.,cO c2 I
l 8TXZ6[;
AI'°VYAC,D BJcsjp~ES'l-Xf05II~ ~
A~
I:>
1:ts1131 c,
~TX26E 3G 3R
~
, KEUEF I IIEUiF I
POSI I IBl.p 1'¢51118 JcL/FCVo{/ <
f\\l Jay
'-'C D
,,A
- OP/FCV661?)'f<75/J/6 OP/FC\\'U/1
?
l-3
~fxto!/1/& >X,Wl/6 9xP¢,//i7
~
y@
fcM fcM CM
/-3 1xeos11~ i
'v P0S l
A h
E4-E5
' x~m X5Vt74A y-111-1"1nts1131 i 116
'7:"'~B -=-
I,t¢s112, I t11-'l N1-1
~
NI*/
~-
Q fto'!//1(,,
P/FCV660 Ci/FCVW l-1 1-2.
I O t:,T/1//0 X$V29J l-4XMJM XM~~/16
\\J O ~P¢S!l25 I p
'FC'J/1233 I
3 ~ I 1/2
-HI 2 xP,s,111 C\\
I Ol'/FCW,{41 rXSV~6
'~ (';
i 1
C\\J le-.
6TG26E vr11,07 XP¢5113/
~
[31'13-0 I,,
0--1-1-A&
12 t 1
\\1-1'~
!t 1/1-Z 6THI 10 C'I
!MSl/25 XP~Sl/23
?¢5113!
- <;;~, ~
D iCL/FCV6{,/
6TX26E n
I
~NI-I'--<:;---~
"=-JI~ ~>---~
,m SV297 1
5'{296 7.'
V29*' X"109,,
XP¢51/!,I Y.
- -2~
i
"'. -r ="-='"-'-"""'--
~e-l X,Vct5 XSV29JA X,W5//17 FCVf£4, FCV663; c,*
N/-,:
Mo/111 L
5A J
-rr::::::D--:-o N I - I CM 6e,rHIIO 8TX26E~
- Cl,IFlVltDTD
~
NI*/
!3TGZGc
--0 XSV2976,--N/-/ --o-~
~ _J
~
BT.-261':
~1-3 )(Plf)51/ll N)-t XSV296
~1\\~AC HI-/
(M
~N/*2 N{"2C/.1
I =
CKT N° J0294SV
= I CKT ;..;o I0293SV
I
CKT /,JO I0296SV
... 1 CNAC It----------- CKT NO I 03 I 2SV __________ __,I COAITAINMEIJT
/-='URGE su,0 PL Y VAL V£5 FCV66/,! ;:cvct:o ViCUUM <!- P/?ESSUt?E RELIEF AIR SAMPLE VALVES FCV679 & FCV681 FOR PIIR&E l:XHAIIST V4lV.ES RCV/2, RCV/1 ANO 4/R $AMPt.E VA!Vl' F'CV678 VALVES,CCV663 t J:CVb64-AJJD VACU//M P/?£SSIIRE R!2LIEF VALVE f;C V 662 ARE SIMILAR SEE TABLE FOR FCV662 & FCV678 SEE ALSO DETAIL 'A' CONTAINM£IJT
( G)
INSIDE CONTAINMENT
( F-)
eRFDS D[SCR/PTJON VALVE NO SOLENOID VIV DC VlVPOS SW IRCUIT CONT'MT iltJiT i50t.
CONT'MT l60L PH;,
VALVt SfJLENOIPYI..
DC VLV,.,.,5.Si.o' CJRClfJT CONT'MT /'ENT !SOL COli,'MT /SOL /'HA ERFDS N° LOC Cf(T l/0 OPF:W CLOS C Alo VEV/Cf LOC CONTll(,T DEVICE LOC CONT11c1 NO.
NO.
,oc CKTl(Q_ OPEN CLOSE
.f./0.
OeVK£ LOC CONTACT {)$Vice t..OC COti!i4CT l;//l.-((}6-23-2 CONT'MT PURqf SUPPLY FCV6G!
ltfUX06-Z3-3 C0/1/T'MT PURGf;
£XHA.UST RCV 12
~§4A R~~~§4A z1so 1118 1:31 102,4::;v K622 RNStB '"-~r..,_, -
Fcv;.r;o ~§5.f' R~~~§~A 111.0 I/Ii#
1111 Io293sv KG22 RNSf/JA *06-~r.os-, -
uuxo5-24 }
4+gA R~~~igA 21so 11s1 1192 1041osv l<G'ZZ R1JS'6s~*- 1,l~06 _11 RCYJ/ ~~§f' R~~4~§A 117D J/88 1189 I04o9SV K~22 RNS~A "'-1:l~... 11 -
MUXtJ5-25-I SEE NOTE 2 J
/,fl.lllJ6-24-*/ CONTMT AIR SAMPLE SUPPL y Fcv1;,79 31,,,
PM/""
1176 606*9 t
606-9 RETUR/,.'
-~
'"" 215D >----- J03l2SV 1<622 Rl!Sf8
,II' FCV&l/3 3/1 X5V3JI 117.D /l33,l/.33A IOJIISV K/,22 RNS¢A A!'
FCV68/
3/4 PM/84 1159 606-10 606-10 M!JKC5-25*J VACUUM P8ESSURE RELIEF FCV663 296 XSVZ9G ZISD 1123 1124 I0296SV 1(622 RNSdJB 606,ii FCV662 Z'/5 X9129fJ J/71) //21 //32 102955.V K~22 RNS¢A 606Ai fC/1664 297 XSV297
!/25 /126 606-8 606*8 MIIXtJ1>-t£"-2 L_ __
_JL_ __________
_j_:_::_ _
_::_c_J__.:_J_c=e=c..L __ J.:.:_='-L!"--=-"-1----L_ _
_[_ __
_j_-"'"'-SCL._...J.. __
...J.. __
_j_ ___
.L..-,-...J.. __
L_
_j_ _
_j_ ___
_._ __.L_~~.L..--'----'---~------'
6 TRAIJ~IENT SUPflRE'!.,;QR N01 U5EI)
- ~f'.i;. 1-.1or£. I pl'-
A X
GR££N LT SPAl?c
--LH-8
.SRSRE SPME pl'-
C X
SPARE VENU"'1f/T
~
I-r.c-D+-~-+~x-+-.,,'cc,!e'~A~L~lccNc+-ccvccENc=-1 "'1 N"'P=u1 VALVE OPEN POSITION SWl!CI!
POSI 128, POS I I 59, POS I I 76 POSITIONS REMARKS CONTACTS OS ope, i. REMARKS POS I I 33A a
E,.,,.ER,,.
-II-A X
5PARE
-II-8 X
~El) LT SCAl-1/J
-II-C
.x.
SPARE
.SPAR£
---H-D X
il'OOiiOR iJ MO/./. LT.
VALVE: CLostc fOS/TiON SW!TC.4 POSI 117,POSI 124,POSI 126.POSI 131,POSI 132, POSI 133A,POSI 189,POSI 192 CONTACT
(}-jf-o POSITION OFF ON CONTfiOL SWITCH.' I 5.HT cs R.11AR.K THIS Dwr,,.
USEC! ON LOCATION; f.HT450 lO SPRING R/3TIJRN LHT450
-,----u
- o--o-- X ---</.
20A PIITBIJ
_L ISEHT T
CS/ON
/,HT450 XI EHT450A EHT4-50A b,-----v--XI TliA/.JSF ;-!-i ~
, f 75
/20/104-Y ~ t-J
~ -
PHTBD U _j ~---0]-U EHT4-50A EHT450A I
EH7450 TS
--<.JI ETHl/-50 PCS/ TIONS REMARKS CONT.~CT.S ~*-~i, OPt;N& POS I 159, REMARKS POS I I 33 POSIT I ON REMARKS REMARKS 1121, 1123, I 115 POSITION REMARKS POSll30 REF I J INTERIM S/IM.Plc 5YSTlM HEAT Tf<ACl CKT,fi-MHTIJO/
INTERM I I 76 CONTACTS t---~O~P~EN~&""l 116, 1118, CLOSE INTERM 1168,1191 CONTACTS OPEN &
CLOSE I NT ERM
-fr-A
-If-6 X
SPI\\RE SPAil!
~:._ ~
X X
SPARE SPARE X
X X
SPAIZe.
X SPARE THIS DIO!i X
THIS DIO!i SPARE X
Tli/5 VW!i SPARE X
Jl'AR!:
SPARE FCV 679,681 fCV(,62 CS I
CS I
/-J FCV!78 cs
~
I RNS0A BTG2¢ "606-9
!:Si
- K622
'NJ:t.E "606-1 o
/-3 RNS0A E-4 BTX26E X
BUi'6t E-.t
_rmr11JJ rlSYJ/1 B TMIIJJA
>-/-J~XftJSI/JJ XSV3II T
Nl-2---6 XPOSI 133 NJ-2 BTKUE IVI
!STGZ~E NJ-2 I
1~=*6cu Df.TAIL A" (rOR f"CV678 & rCY662)
-If-C X
SPARE 5PAtzE
-H-D
)(
.SEA~ IN
_5,1£. IN
~:._ E F
X VENT INPUT VENT INPUT SPARE KEY DWG. SECTION 9
X SPARE 9
10 TABLE OF DEVICES D£VIC£ N9 FUNCTION REMARKS 417,*ltI-aS/TO Tt!<fa DELAY /<ELAY ( 2-r.o Sl!C,)
12.0 VIC AGKJ TAT ETR*l413D003 SET AT 10.sec.
42*/cJ/,!2!-35 480V AC MOTOR STARTER 4!}-/2J*l,!21-3S MOTOR OVERLOAD RELAY PART Of MOTOR STARTEF, 52-121-35 480V AC CIRCUIT BREAKER CH
( 3 )
$2-12J-OJ, 480V AC AIR CIRCUIT BREAKE::R (3) 52-121-02, DB 52-IZI*08R 480V AC AIR CIRallT BREAKER WE.
3 l:!ACk-LJP eREAKER FCV ***
FLOW CONTROL VALVI=
K6l3 CONTMT ISOLATION PH. A AU/i.R£L.
(9) (10)(1.)
K622 CONTMT. VENT. /SOL. AUX. RlcL.
VALVE POSITION SWITCH SE.E Tl\\81-£ FOR N"-'
RCV *.
RriD/AT/ON CONTROL VALVE SV-311 SOLENOID VAL.Ve
/25VOC ASCO IIPLB!J,2/ASE =. NO, ti,"J775£l SV293, 293A, 294,294A, 295,296, 297,312, SOL/;NO/D VALVE:
314,469, 469A,470, 470A Cl05E OPE:I SPRING KET!i/lN TONE{JT fROM OPEN POSITION5 CONTACTS CLOSE NEUT OPEIJ REN/MM
-I~
A X
X 7HIS OWG
-1 I-13 X
THIS l)WG
-I I-C X
)(
Sl'ARE
-II-0 X
SPARE.
R01Aet<.5 f'OJll.3J GR£.'"I./ lT.
.SPA/?!
Sl;,A,1!"'
CONTROL SWITCH J:CVG60, FCV66/
RCV//
cs RCVIZ cs cs cs VAt.Y OP£t./ POSIT/0/-J.5JJ!TCJ-I PO.SI/Or;, f'0.51110 {POS 1133 USliD AT t.oc.
CM EQUIPMENT LOCATION NUMBERS 480 V M C.C. BUS SE.CT. /2J ClJNT.AilNME.NT PURGE SUPPLY FAN. S3 CONTROL BOARD
/VB4 ALLX £Q ~ [.)SL SP2J MP2JI CM RNS~B BTHJ/0 PM/23 f3TG2'E XSVt!Jf Xf'?Slt/8 CNAC PHTBD LHT450 EHT450 RAC;<. NUCLEAR SAFEGUARD OUTPUT TRAIN B TE.RM/NA/.. BOX AREA H ~
/10 ME.CHAN/CAL PAN£L N'2 123 SLOWDOWN TANK TERMINAi_ SOX Ne G2G~
NOTES:
ItlSrRUM:,/T Mo, SV294- /..OCAL /IIOVNTED INSTRUMoNr f'/C,. POS 11/8 LOCA~ MOl/Nfll!l COAJTJ?OL E,V. JV8/ SAFE.GI/ARDS HEAT TRACING DISTR. PNL. No. BO LCS HT. TRACE CONT. 450, 450A INTERIM SAMP HEAT TRACE 450 I. THE SEAL-IN FOR VALVE FCV 678 IS NOW A POSITION SWITCH CONTACT WHICH IS CLOSED WHEN THE VALVE IS IN THE OPEN OR INTERMEDIATE POSITION. PREVIOUSLY THE SEAL-IN WAS ONLY CLOSED WHEN THE VALVE WAS IN THE OPEN POSITION.~-;:--:"'-':~V-:::::::----:::-----:---::--~--:--;:------~-
( 2 FUSES REMOVED DURING MODES -1, 2, 3 AND-4 (PER.TS 3. 6. 3 l TO
'----'\\. DE-ENERGIZE FCV-660, FCV-661, RCV-11 AND RCV-12 VALVE OPERATORS. )
REFERENCES
/.
DESCRIPTION OF ELECT SLHEMATIC DIAG's.,SYMBOLS &: CKT. D£SIGNATIONS-DWG NrJ 050003
- 2.
/;QUteME.NT LOCATION NUMl3ER !_/ST
/OJ 900
- 3. SINGLE L!NIE METER 8, RE.LAY DIAG.,480V BU'> Seer. 12D, E, I._ J 437538 4 SINGLE. LIN iv/£.TE.R 8r R1=.LAY DIAG., 12-5 V PC SYSTEM, SH,/
437546 S:
PIPING SCHEMATIC VENTILATION e. AIR CONDITIONING SYSTEMS
/02023 G. INSTRUMENT SCHE.MATIC FlOW INSTRUMENT SYSTEMS 102632 7 SCH/:M/<TIC DJA(if<.AJv1 !t1Allv ANNUNCJATOf',.
501 /~!,
- 8.
VENTILATION CONTROLS AR!;A F" a, '1G" 59336
- 9. @ FUNCTtOrJ D/A<jRAMS 1<5C,/V!l l,i,,/9$
- O. @ SOL//)
- STAT.£ l"l?OT~CTION..S'r'STJ!M
.R.fC,KI-66323/
/i. SCHEMATIC DIAGRAM MONITOR LISHT BOX 13 DWG-N~ 437637 12 SCHEMATIC DIAG. AW. Ii, Fl./£(.
HANDLING 81.DG Y£NT, srs, ( POV I I J)WG. Ne! 444646
/,
fl U
II I)
II
/;
I*
11 H-. BLOCK DIAG.-ERl'DS T£CH SIIPPORT C£NTER & CONTROL ROOM If StNu/£ LINE METER J: if ELA Y !)tAC,ffAM, /ff V PC.5r'SffM, 9H. 2
/6. SCHE:M {)/AG, SSPS OUTPUT RELAYS, TRAIN A, TRAIIJ B 17-DELETED VA£Ve N(JS. : FCV6P4, FCV.f55_, /'CVt,56., FC//,S$7,, A:J/660,
,CCVb6/_, l=CY(,62,,t'C~6!;,, /'CY66~ ~//678,,
FCJ/67?, FCV6dl,RC// If f RCV IZ NUCLEAR SAFETY RELATED UNIT I
( POV2 I,t;WG-. Ne 444653 DW6. )J"' 4452 73 f)Wt5. /,IE 44'i07f DWu5 501869, 503088
~
),._
B C
P.G.&E. SYSTEM PHASE SEQUENCE A-C-B VAi. VE CL':JSE POSITION SWITCH POSI 133,POSI 159,POSI 176 VALVE OP[N POSITION SWITCH PO.~///(;, FOS/118, POS1l8a, />OS/19/, POs//2~PfJ5112tPtJSll2f VALVE CLOSE POSITION SWITCH POSI 130 DATE 04-16-2018 REVISION DESCRIPTION ELECTRICAL SCHEMATIC DIAGRAM CONTAINMENT PURGE SYSTEM DWG SCALEc D. D.
FAZI R. E.
FXC2 I. V.
NIA P. E.
N/A 4NPG "I S lze I
I I
I I
I Revised Per DDN-2*1722 I
DIABLO CANYON POWER PLANT PACIFIC GAS AND ELECTRIC COMPANY SAN FRANCISCO, CALIFORNIA I
I BILL OF MATL*
SUPSDS*
SUPSD BY*
DRAWi NG SHEET PAGE REV
~37631 I
O 29 U2-441490
~
FOLD FOLD z
~ -
i r<)
~ <!)
C r--
r<)
OLD4
'"'