ML20268B099

From kanterella
Jump to navigation Jump to search
5 to Updated Final Safety Analysis Report, Chapter 8, Drawing 496275, Rev. 11, Sheet 1, Electrical Schematic Diagram 4160V Diesel Generator Control No. 23 and Associated Circuit Breaker
ML20268B099
Person / Time
Site: Diablo Canyon  
Issue date: 06/30/2020
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20268B299 List: ... further results
References
DCL-20-075
Download: ML20268B099 (1)


Text

{{#Wiki_filter:OLD4 CUTLINE 0 N E FOLD D C FOLD B ~ A N C N 01 O TI

  • C Ql 0 o,+-

'TI 0 .o 'o Li) ' r--_N N ' <( "' Li) "-- O'l t--.. SJ"N L II r..p (l) 0:: "' '1) wsr=i f-VlZD <!C><! o::ou I SL<'.96\\7 2 o' o' "' 3 5 6 7 3 r-+--0 4 r-+--0 + VTD 1' 62 5 6 1-1 (+) NON-MATCH Q CIRCLE ~ REF NO. 5 """""' < CHF 8GI OG 4GI ( ( ( F . 5 3 I ,--.---+--+--+-------, I I ____.J PHASE SHIFT TRANS MATCH CIRCLE REF 0 5 §) ~- OG 8GI 4GI POWER SUPPLY 2 I r( _3 _T_Y--,P I 2 2 ~ ~ 4160V BUS SECTION "F" A----+----------- B----+-+---------- c------+--+-------- r-+--t--(:>-,--<:)--0":<r-C' -~y-J~ 0-----0-- 5D 3 -:-(_'J"'.<'r-C~>--Y'"-l: C>---, r:-:f:--(->-..-C 1 -)----;Cf,.,-'x-< *-:>--if" J 0---0f-7 D 3 ,.,- ~ _ oo-Qt( ,._.: I = /~ - V = -/, - V-( T - 0----0-- 90 3 c7 't--0--.1-0-----0--.-c)-o-- --- T OD ------0--.e-0, SHF7 RHF 5 , r T T,0,A 6 5, r T T ~ .,_+-t-------+-<-' , ~,,~ ' '-+--+/-~, y y, 0B SHF7 4GI OG 8GI 6' / '5 51HF7_j (3-1¢ RELAYS) -= i----BUS DIFF CT & POTENTIAL TRANSFORMER ARE NOT SHOWN. SEE REFS 5 & 6 0A ,A ,r-<:->---r '--"()----'-7-~ Jr 1 1 1_l,_-8_~ ~,, ", v '06 T ~- ~ ) -' 60015A \\ 1A __ -o _, '----?o----7~)_,r 1 1 1 l 8 I _ 1, J _ .........,. NON-CL1AlS f f RHF V , 0 C l'-----0--~ l>----+--'I \\'.A,'--(:~6----7--+_J'T I,~l'>-'-8---o---<'>-0--I-----II------' f f C L1AES S.----- - - - ~ -1 4 I )I (~7 I ,,",,....,,,l'-,,1'- I I ---1 1-- 7 I 3 2) I PHASE I 6 3 I I F 3 I I SH I FT I u.;__ I I 6 I I 7 6 5 4 TRANS I I I,---l I _j LJ :

1 5 :
r 7 :

1------r-r----- 1 _) ___ I ,1 -,;-//,,- -1 I I I 5 I I I I 1 I I I 12 9 IO I 4 3 5 6 ,I I I I I C __ H __ F RHF I 7 6 I 7 6 5 I ,--::---------r-----+-+-'>-------+--'------l------+------+----+'-+-'--i----------- oc = I I 1 I I I I I j 1 V ~ QC / 51HF7 (3-10 RELAYS) £ DISC IN FIELD 1- - - - - - - - - -1 I


j ~

I CS I I ( CO Q I >----<,_,f:v ) I 0 ~ ALARM SEE REFI 3 , 9 ~~~>-'-8.,..: __ -D"P.-o-t=-+,-,1 3'--' 8 7,,4,1 __ ---r-1 __,.1 o__,,,...---.1---,:-<=:r-'--,."':>-1-<:_,,,.P-- 19 11 19 11 Ar-<.=>-'---:rC.1>---or 51 --c--------,--,.--------+--+-9-<ef-_-:_rYn ______ 8 RHF sHF1c:,.....1~-:>--+-""t;,,,

  • -+-: -----+:-----+-+;...: ____

v _

...'1 ___

v __ __L1 ___ cr.P--~o-:_-+-1-,'l-:_-:_-:_-:_~+-:l~~-'-+-:l~~~~-----t_,_,;1-=, ___ 7 r*- rv-v---. I ~oc----::- 1 -, ~ 600/5A ~ I I I A--(_)--,' '-.'<:!}---Qr 7 I --C-+---------,--;---------+----e-~',,, ~ 5 -o--o--"o--'o--


I' I,-----,

I I I I I I I I I 7.------. 6 I O _ 7 -o--o--lt-0--_-+__,I 113 L...../\\ ____J 2,1 0---o-+-+-l--'-:1, *,, 6 5 \\ 2 1 I I \\, ~-----8----1'-<:>--'----?a,'.>----1-0--0---o--t-11~0,1,\\/...::2:.+'-+:ll...::O,\\\\, __ 2---tl~1,'.A,'-c_>---r- ______ '01_0-- 91 --c I /\\ 7 f /\\ _J\\ _J\\ 7 I ~------7+----i-----O _ 9 ---0---0---<'>-0-----11-----+----, ~ v"7-1 v v 1 1 v 1 i v 1 1 v i v 9 ° ~-+---8-i--1-9-+0-'* r-T '[ fA- +-8_,___,__3~0 ---.-t r 2 11 Y K Z I 15151413 1VAR I 2 I 9 12 IWTD ~---J '---~


~ ___________

_j ___ o_ o _:? __ JH l ___ t_j ___ l TD 1 _ __ 1~ ~ VAR W 32HF7 40HF7

      • ....................................... *********=

f ~-,~ ~_,, fNON-CLASS IE L _J -/8+/A y CH.4 L N L _J +/A-/B y CH,3 ...L UL -/B+/A y CH.2 L +/A-/8 y CH, I RECORDER RW-CH. I RF-CH.2 RVAR-CH.3 RV-CH.4 L ___________ _j 46HF7 50NHF7 .--------7 I -21\\; 6 I I r-----1'----0--+--o--t--1-~' I I I -

  • 50/5A I

I SERVED BY CKT = K3-23 I I ...L 1ALARM, REF 131 I SPARE I SHF7 TO I 20V AC {

  • 514YOO IREF 41

,'+-----------~

lu MATCH CIRCLE REF N0.5 111~101 I I A B C NON-CLASS IE I V I I I NTLK REF IO I I Ar I L _____ I I _________ I SED23 CR66 r-------------------------------------+-+-.------------.-------=B,.1..::6----=<>---------+---8=-cG::.:2=--+oE I I 0 617 OG DRB23 r----7 I 2 I I I ot--,----s,,-----.,1------<o----++-o -8 7 L 3= DR823 3 4 r---------.----+------------+-,.__--.---~o-------1-------1-----.>-c----,--------__.----,--,----,----+oE2 r-----l----------.--+-----+------------+-,.__--t--------ll------l-----+--+-=B*l~8 _____ 4~G~2=--+oE3 1 8 ' I 2 ' I L 2=

.------,1----

I FI O I l 2A 2 ~- ------ ---1 I I FU15-0I l...A,,---- EGIOB23 HYDR ACTUATOR 1 i i1,.. HY 17 I I I

  • L l-2o+-,----.L>--------+---i1------<~>-H-o:8 6 pltET 3 40 ::.+----.--,1----+-

8ot--------1 A M I -8 5 REF I 4 3 3ot-

----.-----t-----;1r.

& DWG 35:: ,,-, ~,N ~,- 9 84 499404 Jf-If-If-I FI02 2A ~ 2 VIS:,f,~,~=P,J,{ 1 I I v F 2 I ( XEGIOB VOLTAGE REGULATOR ASSEMBLY SEE REF 14 & DWG 499403 PI ot---------+-o-'P I Du )u Ju

        • ******~ --

I o------+-~ ---+--. I I l-1-- - - - -- - -

  • f- __,

f NON-CLASS IE J SED23 4G2 OG l GQD23 FUl6-0I 2 SED23

  • YM-36

() ) () EG2 EGI ( GQD23 EG2 EGI SED23 1 l,t-------t, j I 2 3 17 18 I 9:: 3 4 5 6 7 ) <) () <) I) P2o+--------t-o::P2 1314 ( ( 16 14 16 15 14 0 MATCH MATCH SED23 CIRCLES CIRCLE

  • ~\\----

L-.::Re!=Ec:...F__:_1 c:...I ___ R_E F __ I 0-r-;-;;-;~:;-i.-=--_J ~ , YM-3D,

  • DRB23 SED23

( - B 14 1101 141 I 36ot---+-----t------t-----ll----+-~ 35 33 34 G) MATCH CIRCLE REF 10 I) I) NON-CLASS IE YM-3C I EGA CONTROL BOX REF I~

9T 13T :

2 0 ot--~--------1.....,-0 B I 5 L - DRA23 - I SED23 r------- NON-CLASS IE--==-~ PM-DST23I REF. 15 T 65-23 cs PM-DST23 REF. I 5 ~ CHF SED23 29 -23 6 r---------11---i ', 1----o--- G P2 ---{)1--------,Ftf "-:-E~--t-U-4 611\\,,AAII 46 1~ 13 r-+-~"-'+----t

. 9 MOTOR 2o+
---+---+---+o I 4

,~"AcHF SED23 29-23 I J,,,J OPERATED 3::, 15 0---------1~---i, ~ GP 3 ---{) " 2 4 r---t-o 7 GOVER NOR I o 8 6 5 7 BIZ,, Al2 POTENTIOMETER --~-'-=,-I () () () () ( B

8 REF 14

!f-4_3 _____ ___,.~-~B 2,,,l---1"-* f--ScAe'c6 ~-~=~~~

21 22-1 8 12 I I - ~ -c : I 7 I I I ' 6 IO I I -~ I ! 5T 9T 1 SED23 _______ I A B C T3 T2 TI GGD23 87HFG r-----------------, I I I MATCH I CIRCLE I REF *7 I s - I I I I OP I \\..A.) 5 ./ 1 1 9 6 >-< '=----J,, I 4 >--{ I OP I \\..A.) 4 / , 1 7 15 1 ~ Rf-f---+ ),- J" 12,< '=---~J,,*, 13 I OP I \\..A.) 1 3 ' -<__:_rr,,n__--=l - ~ R t----+--+ ~ 17


1--1---

DRB23 2 " I 29-23 I\\, E CHF SED23 2(,~~13 ~ GP4---<: "' 18 Bl\\, Al >---'-',-'--c-------~ \\:

  • C CHF SED23 2_r,~_2f'

____________, ('-------------- Y V V BTA500 ,,---o-- F +~---o=o:=---~',_,,..,..___, MATCH 0 GEN T ~ CIRCLE B FI ELD : <':) DIESEL GENERATOR NO. 23 4160V, 30, 60HZ, 3250KVA, 2600 KW, 0.8 PF, 900RPM 44 F107 r 2A o----C---i' 1----o--- G P5 ---{) L..-{)-- GP I ---<:>----~ SED23 CHF 48 ~h\\. 8 "' ".A 7,.--It-µ RESISTOR BOX DIESEL GENERATOR NO. 23 AND ASSOCIATED CIRCUIT BREAKER - CKT NO. F07H REF 10 6 RES TEMP DETECTORS IEMF'S REACH POSITIVE MAX VALUE IN ORDER OF Tl, T2, T31 '---o-- F- -,::>-----~ SED23 I SEE NOTE I I MAGNETIC I SPEE;// PICKUP MATCH CIRCLE r;:;;'\\ REF I O I,,'.__':')~~ GGD23 BTA503 BTA503 RHF OD ---0-----0---.-o-c~oD---o---0-<o--o""' LJ,( _J.( _J 600/5Ai CT9( CT8f ~;7 , >-,,,w 9 D I ~ 9 D 2 -()----o_-:_~.)--().-J ',,~ ~ ~ ~ '----+--o-- 7 D I ---o---0-c;';___---0.--0.., ~ ~ 7 D 2 ~o-~ -+----t---v-5 D I <-:i_::'-{

  • -)--().--1 0 5 D 2

~ vo--- ~-------i ~ Tv,6---,,T.,,c5>--"'T4-()GGD23 KEY DWG. SECTION 2 9 0' 8 0' TABLE OF DEVICES DEVICE NO. FUNCTION RATING MFR TYPE A AMMETER w WATTMETER VAR VARMETER 1----=-W:..cT-=D----1-W::.:A_:._Tc_T__:_T_:_R::..A::..Nc=S-=D-=U-=-C=-ER__:_ _____ ---J_-=--_---l-_'..l,\\/l~Af.1n~'M""'~ XL3 I K5A2 VARTD VAR TRANSDUCER VTD VOLT TRANSDUCER RW RECORDING WATTS YOKOGAWA DXI004N RF RECORDING FREQ YOKOGAWA DX I 004N RVAR RECORDING VAR YOKOGAWA DXI004N RV RECORDING VOLTMETER YOKOGAWA DXI004N WH WATT HOUR METER F FREQUENCY METER DRA23,B23 DROOP RELAY(UNIT-PARALLELI 32HF7 DIRECTIONAL POWER RELAY 40HF7 LOSS OF FIELD RELAY 46HF7 UNIT NEGATIVE SEQUENCE RELAY 50NHF7 GND CURRENT SENSOR RELAY 51HF7 DIESEL GENERATOR 0/C RELAY 52HF7 AIR CIRCUIT BREAKER 87HFG DIESEL GEN DIFF 0/C RELAY K3-23 FIELD FLASH CUT-OUT RELAY FTD FREQ TRANSDUCER RTM RUNNING TIME METER V VOLTMETER MASL23 MANUAL AUTO SW FOR VOLTAGE REG 29-23 DIESEL CONTROL ISOLATING SW EGIOB23 ENGINE RUN SOLENOID (PART OF HYDRAULIC ACTUATOR! YM-36 DG23 EGA OUTPUT VOLTS SIGNAL ISOLATOR MOORE IND UB YM-3C DG23 EGA MOP INPUT SIGNAL ISOLATOR MOORE IND UB YM-3D DG23 GEN VOLTS ADJ MOP SIGNAL ISOLATOR MOORE IND UB CATALOG OR REF DWG 3 3 3 3 3 3 3 3 3 3 3 3 & 4 10 3 3 3 3 3 3 3 3 3 3 I I 9 10 FCT/0-5V/0-5V/U FCT/0-5V/0-5V/U FCT/0-IOV/O-IOV/U IGSL, GSRI 10 REMARKS ALARM ONLY ALARM ONLY OFF LOWERlRA I SE CONTACTS LOWER OFF RA I SE REMARKS BC AB CA OFF l Al 1---II-B1 I A X A12---II-B12 B X Al-II-Bl C A5 -II-65 D X A6 -I I-B6 E X A7 -II-B7 F GOVERNOR CONTROL SWITCH SPRING RETURN TO OFF USED AT LOC CHF & SED23 THIS DWG THIS DWG X THIS DWG SPARE THIS DWG X SPARE 65-23 cs CONTACTS OFF PHASE PHASE PHASE A-B B-C C-A REMARKS -I I-A X -II-B X -II-C -II-D X -I I-E X -I I-F VOLTMETER SWITCH VIS USED AT LOCATIONS SED23 THIS DWG THIS DWG X THIS DWG THIS DWG THIS DWG X THIS DWG EQUIPMENT LOCATION BTA500 GQD23 SHF7 RHF SED23 GGD23 BTA503 CHF XEGIOB DIESEL GEN 23 DC FIELD TERM BOX DIESEL GEN 23 CONTROL PANEL SWGR 4160V BUS F CUB 7 ENG SAFEGUARD RELAY BOARD BUS F DIESEL GEN NO. 23 EXCITER CUBICLE DIESEL GEN NO. 23 MAIN LEAD TERM BOX DIESEL GEN NO. 23 NEUT CT TERM BOX CONTROL BOARD ENGRD SFGRD BUS F HYDRAULIC ACTUATOR PM-DST23 DG23 START TIMING DATA ACQUISITION (DASI PANEL NOTES I. NAMEPLATE VALUES DEPICTED ON THIS DRAWING, REFER TO CALC 015-DC ISAP* 9*377601 FOR RATED VALUES. REFERENCES DWG NO. I. DESCRIPTION OF ELECT SCHEMATIC DIAG SYMBOLS & CIRCUIT DESIGNATION ________ 050003

2. LIST OF EQUIPMENT LOCATION CODES ______________________________ 067998
3. SINGLE LINE METER & RELAY DIAG 4160V SYS BUS SECTION F _______________ 441229
4. SINGLE L !NE METER & RELAY DIAG INST AC SYSTEM SH 2 __________________ 441242
5. SCHEMATIC DIAG POTENTIAL & SYNCHRONIZING 4160V SYSTEM SH 2 ____________ 441340
6. SCHEMATIC DIAG 4160V BUS DIFFERENTIAL SH 2 _______________________ 441343
7. SCHEMATIC DIAG 4160V DIESEL GEN NO. 23 & ASSOCIATED CIRCUIT BREAKER SH 2 ___ 496276
8. SCHEMATIC DIAG 4160V DIESEL GEN NO. 23 CONTROL SH I _________________ 496277
9. SCHEMATIC DIAG 4160V DIESEL GEN NO. 23 CONTROL SH 2 _________________ 496278
10. SCHEMATIC DIAG 4160V DIESEL GEN NO. 23 CONTROL SH 3 _________________ 496279
11. SCHEMATIC DIAG 4160V DIESEL GEN NO. 23 CONTROL SH 4 _________________ 496280
12. SCHEMATIC DIAG 4160V DIESEL GEN NO. 23 CONTROL SH 5 _________________ 496281
13. SCHEMATIC DIAG MAIN ANNUNCIATOR SH 17 ___________________________ 500787
14. EXCITER/REGULATOR ( BASLER) MFR DWG ____________________________ 663082
15. DAS VENDOR DWG _________________________________ 663082-342 THRU 354 NUCLEAR SAFETY RELATED UNIT 2 REVISION DESCRIPTION DWG SCALE:

~ ),__ B C P.G.&E. SYSTEM PHASE SEQUENCE A-C-B DATE 02-24-2020 Revised Per DFT-7*5086 ELECTRICAL SCHEMATIC DIAGRAM BlLL OF MATL: D.. FAZI R. E. RXG2 I. V. N/A P. E. N/A 4NPG 4 size 4160V DIESEL GENERATOR NO. 23 AND ASSOCIATED CIRCUIT BREAKER DIABLO CANYON POWER PLANT PACIFIC GAS AND ELECTRIC COMPANY SAN FRANCISCO, CALIFORNJA SUPSOS: SUPSO BY: DRAWi NG SHEET PAGE REV 496275 I O I I DFT-7 *5086 FOLD FOLD ~ Li) i r--- ~ N 0 sr OLD4 cu,}}