ML20268A885
Text
A B
C D
a:,
0 N
I en N
I I")
C o
CJl u
- C QJ
~E
,o I") I N "1" N 0
I <(
a:, I") LL ON""
-0 \\_
II 00 (])
0:: 0 (I) w -
- J f--
II VlZD
<(CJ<(
o::ou 40 41 42 43
)I 22A-Bl931)
PLANT VENT EXHAUST & MONITORS AIR PARTICULATE
& NOBLE GAS MONITORING HIGH LEVEL IN.5T~UMENT Alfi: Ccrs)
CLASS
( Pt/RGE)
!45C3 NOTE (RE\\ )I 22H-A 1931) 13 ~
M/1)-MNGc MO/\\IITQRS.4RL'A ARcA MON/TOA (At!M4)
ATMa.5 25CI I,.-, J-/
[: NOTE 8 lcLAss 1 SPE.C8802 (ABANDONED RV-429 IN PLACE) l;------..1 u-1 l;----_;__..,..i I l;-----~
u-1
[:--i :,1(~1--...--+,
RCV-32 r; ___
___::S:.,.;-1~
I. CLASS ----
125G-A HIGH RANGE GROSS GAMMA MONITOR 44 SPECIFIC PROBE SELECTED TO BE DETERMINED BY FIELD TEST
( TYP OF 5)
FCV 678 NOTE *lO t
S-1"4" p
L A
FCV-to98
/VOTc 7
45C4 45 our S/ De CON'TA/NM&VT r:1 s
S2 46 47 48 CONTAINMENT ATMOSPHERE MONITORS & SAMPLING 7.C~
5 Nore!~ I
I S2-3837-I T.Cij r., s II]
5 ~
I S2-3/4
S2-3838-I T
FCV-679 45V3 FCV 681 FCV 1428 r.,T.V.
45V3 45V3 TRITIUM
'--.L...~;io<l--4~----C<MONITOR 45V3 45C4 F. C.
F. 0.
SAMPLING (NOTE 9)
S-521-1
)1 I I/I 18-Dj931)
S-520-1 CNTMT GAS &
AIR PARTICULATE MONITORS S-4999-1 POST LOCA SAMPLE
-<1"'""1,-r-,,-D"""'-6c-::9c--? COLLECT I ON TANK 2-I DRAIN COLL. HEADER AIR 45V3 SAMPLE SUPPLY T. V.
r.,
~'-.._./
_ _;_~___;~'-.._./---1~1-,,----....--'-:::../-___;,,.---..,_
__:_'--.-/-i:,_......:....,,,--...___:...._'.__/
~ 60-D II FCV-699 I S-4670-1/4 T.C. (SPARE)
[filI]
:]
~
S-1/4 l~> s-1/2 NOTE 4
)4 72J-E!32)
S NOTE 3 f' T. J/.
45V3
/'
~
"-.__,.I
'....__I S-46 72-1/2 AIR SAMPLE RETURN II D-66 POST LOCA SAMPLING 49 RADIATION N
45V3
~ ~VIV 700 B E
.7;V5Tfa-UMclv7 AI.R.
(PUAf,)
I N'oTe II
L.:.I T. c.
)474G-E!32)
Tl/
r.,
100 45V8 45V8 MONITORING I
T:
~
M FCV 236 IO I 3NPGIC 3 Size PLANT REMOVABLc GASEOUS RADWASTE FILTE.R 2-1 I ABANDONED r~-/
,,....___ s-1 1
I L.:
'-.J I
I IN RCV-37 I
I PLACE I
I
[:------~
I I
S-/
1 GAS 38 DE.CAY C K2 TANKS 24 CNTMT.
HYDROGEN PURGE 30-B >-----11~
K-4394*4 V
MJTe/
H K2-2645-/
K-3634-2 E
H 3"
8 NOTE2 42 D
(T'(P-2)
)4741 -cl 32) y N
GLAND STEAM K-510-Z K-i 743 - 16
_Mf:.f:....:..H;;_.-'
CONDENSER
~
ARCH.
T
~
....... ~
-- "!!~ ---......i NOTE rCV S
Z3S 11/0Tc 45C4 7.......--1 45V3 lvOTES
)475G-E!32)
~
T.C.
OOTe s
MJTES COI\\IT A/NMcAIT WALL
.s FCV 238 45C4 45V3 l:J T.C.
S-4633-3/4III THROUGH COMMON lli1m (.I/1/STAllMc/VT ClASS)
I" SLEEV[)474G-D!32)
S-4634-3/s FCv
<.37 IVOTE3
FCV' s I
<39 Ti/
r,-,
I 03 45V8 TY r.,
104 45V8 45V8 102 45V8 PM #209 CEt. -f)Z
) 151-B J31)
CONTAINMENT HYDROGEN r--.... ---- ~--------..L..--------1 ~~~--,
105 PM#2/0 CEl-83 IVlONITORING S-4635-3/4I I I THROUGH COMMON I" SLEEVE)475G-Dl32)
FCV 240 Tl/
107 45V8 S-4636-3/4 NOTE 3 ffi!IJJ ( INSTRUMENT CLASS)
) 158-B I 31) 45V8
- 8.
106
- 9.
I O.
I I.
I 2.
I 3.
ISOLATION VALVES TO BE INSTALLED NEAR RADIATION ELEMENTS QUICK DISCONNECT COUPLINGS FOR TRITIUM MONITOR ) 47A)
SEE DWG 049099 FIG 950 FOR INSTALLATION DETAIL~-
VALVE UNDER SPEC 8179, PO ~013226, DC 663316-1 I I RCV-32 AND RCV-37 ARE ABANDONED IN PLACE, FAILED OPEN 43-B/C WHITEY VALVE MODEL B44F4)42-C)
INSTRUMENT IS PIMS SYS 39 ~
<IEI)
~--- K-109I-4 FJJL HANDLING t
66-A 021>----------'
BLOG- £XHAU5r FUTURE CONN
~
1 s;5;iT~R (FROM FANS E*4,5,IJ) t!~~:trHO; [!-
FCV-51...,i 68...
-"""-/~ :j:j[
(SEE SHEETS 3)5 ~ ~
en
~
f I}
FO/< CONTAIN'M~NT ii ~: ::~:: ~~~:: :::~ ~;::: ::: :~:: ~:~ :~:~~:
I 4, RE-24, RE-28A/B, RE-14A/B,RE-32 & RE-33 ARE ABANDONED IN PLACE. REFER TO DWG. 049099 SH. 7A, 7B & I I. ~
lXHAUST AIISC. EQUIP. 68 ORN. TK. 0-1 I 9 4
ex~fufr~it'<.
f DISCONNECTED
- ~=I,m"NTEP-/o.,.,_ SffCIPICS)'<**<<<<<>)}I (FROM FANS Z~*/4,ZE*Z) f Fl{OM OOM£.5TIC S-7160-3/4[I] LJIT>e-1 WATER SIJPP/..Y I")
32-C I")
SH AUX.BLDG. 5
$UMP 0-1 19 r---
CNTMT. PtJl<G£ AIR TO TURBINE BUILDING SUMP VIA ANNULAR R INC,
- 3. INSTALLED IN REVERSE TO NORMAL FLOW DIRECTION TO MEET CONTAINMENT ISOLATION REQUIREMENTS
- 4. CONTAINMENT AIR SAMPLE & RETURN TUBING SHALL PASS THROUGH A COMMON 2 SLEEVE SEE DWG 501915 FOR DETAILS, DWG 501035 FOR A COMPREHENSIVE LISTING OF MECHANICAL & ELECTRICAL PENETRATIONS
- 5. END PROVISION FOR LEAK RATE TESTING
- 6. DELETED
- 7. ELBOW TURNED DOWN <KEEP, CLEAR) 1-0:....:3_-~279:;:--~2 0.:....:....:1 B+F:::-:A:.=.Z~I -rF~X,:..:.C:--=2+:N~/..:..A+N~O=-::T---:-:cR-=-E :::::Q U::..:..:,I R,:..::E:..:'.D~P-=-E R:...:.......:C::..:.F...::3:..:.....'..I ::::...D::::...5 +-----+----+----=--~ R e v i s e d P e, DD N - 2,. I 6 I I DATE DWN RE IV PROFESSIONAL ENGINEER PE DISC.
p E" PE EXP.
lJ NIT 2 DIABLO CANYON POWER PLANT - PG&E CO, VENTILATION & AIR CONDITIONING SYSTEMS DRAWING SHEET PAGE REV 08023 4
0 88 A
B C
D E