80 81 82 83 84 85 86 87 88 89 ro m

m

' ro 0

A B

C D

~E G)

+-

0 D

TO I 9 c-80 UNIT 2 EDUCTORS 2-1 & 2-2 (DWG 108019)

S2-3479-2 vn 28 PI 31

( 452B-A I 32)

FCV-63 S2-3479-2 MIXED BED DEMINS U-1 STM GEN 52 _4344 _2 8 8 -c 04 >-----I.... --,

79 -D 08 V-1 I A RESIN SAMPLERS

( ISOLOK AUTO SAMPLER DC-6981 06-1 I NOTE 6 84A-A SPENT RESIN LOADOUT U-2 RESIN SAMPLERS I D WG I O 8 0 I 9 I 86 S2-3334-21/2

-c 19 EL, I 15, -0" S2-3323-2 BW U-1 DEMINERALIZERS 1-2 NOTE 8 SEAL GLAND TEST S2-1597-21/2 S2-3331-21/2 [8J S2-3333-21/2 V-IOA V-153A S2-3327-2 16 V-12A 85A -A RV-48 D u SPENT RESIN EDUCTORS DC-663270-35 85A -A FCV-1 306A

( 452E -A I 32)

S2-1597-21/2 S2-3332-21/2 [8J S2-3486-21/2 V-10B V-153B S2-3328-2 I - I S2-3332-21/2 FI SEAL GLAND TEST S2-3343-11/2

...___,---.303 f'-------,

U-1 DEMINERALIZERS 16 EL, I 00' -0" S2-3324-2 BW Du 79 -A 08 S2-3597-2 V-11B 65B -D >---.... ----'

RADWASTE ION EXCHANGER 0-1 V-21B V-35 V-156B S2-3071-11/2 i---- 8 2A -B) 28 u D MOTIVE WATER TO LOADOUT EDUCTOR 0-2 S2-3383-11/2 S2-3340-11/2

-....t-----~78IA-B MOTIVE WATER TO V-21A V-156A V-77 PCV-LOADOUT EDUCTOR 0-1 FLUSH WATER n V (FROM PROCESSED WASTE PUMPS!

28 65 -D ").-----"--1 S2-3355-I1/2 V-70 D u28 S2-4008-1 nV STR 22 85A -A 85A -A FCV-I 308A

( 456E -A I 32)

A 6

&L RESIN SAMPLE RETURN V-l 4A vn 16 8 6 A -A >-------, I 0 S5-2 BW 6

S2-5870-3/4 NOTE 7

NOTE I 0 22 S2-3334-21/2 (272B-E I 33)

LT (161C-Bl34)

PT 65 3 I S2-3919-11/2 nv 16 STRAINER STRAINER SPENT RESIN STORAGE TANK 0-1 DC-663270-42 STRAINER S2-3484-21/2 S2-3921-3/4 V-80 1

((ill 4"

611 ~ """ [El

~G&E P-0120 y.lEJ 3"

5_.._

-2 4

S2-3482-11/2 S2-1640-1 1/2

,______.,___, V - 3 6 A NOTE FCV 1056 NOTE 12 (LOCATED 2

D u 9

INSIDE V-37A TANK ROOMI V-6A :,-------+1-1 PGE S2-3337-3 D

S-2 86A RESIN S2-3070-2 82A LOADOUT l_jJ SAMPLERS S2-3383-I 1/2 BW l_jJ EDUCTOR 0-1 S2-5872-3 28 V-I 57 V-23 ~~ NOTE 9 u

D nV Vn

r14x420 S2-3355-11/2 HCV 130 28 S2-3475-11/2 V-163 V-151 V-149 28 S2-3355-I1/2 SLUICE WATER BOA FOR l_jJ RESIN DISPOSAL V-33 tE-S2-3151-3/4 SERVI CE 82A AIR

~

LJ C-0250 S2-3382-3 BIA

~

SPENT RESIN TRANSFER FILTERS S2-3335-21/2 nV 16 V

V-1 76C S2-3923-1 V-85 S2-3/4 V-86 S2-3/4 V-55C V-55A V-51A V-159 28 D u S2-3475-I1/2 S2-3386-11/2 Vn 16 V-175A V-25A S2-3375-11/2 V" 16 V-175C V-25C

  • -A"°"2 S2-11/2

&ll I'-___,_

16 ~-~ OVERFLOW f-lo-~- 83A -c FILTERS LJ S2-3379-3 S2-3374-1 1/2 S2-1800-3 3/4X42D vn D

RV-40 A2

~

P-0120 3/4X42D Du S2-4009-2 BYPASS PX 393 R-0186 21

..=i1e-

,,.,

  • S2 392

~--- =t= PX

~,~~~

~

S2-3549-3 S2-1626-4_~

s 2 - 3 4 7 8 -2 0 - I

(~---,,----, H t--r-,---;--1----<; 6 4 -c P-0120 c?,

6 Du A2

~

(SEETYP, DRAINS Du 28 PROCESSED S2-3477-2 ON SRMW PP 0-2 I START-UP 6

WASTE S2

  • STRAINERS RECEIVERS 17~~

,,., ~ ~ ~

S2-3514-3 p _ 0 I 2 0 R -0 I 8 6 0 _ 2

(:s:-+-4---t r----r1 11 t-'-t-r---~ 6 4 -c 16....__.,,, 600# FLNG S2-3550-3 28 S2-1627-4 ou D[...,.-11-+-

I TYP, 4 I S2-3475-11/2 V-158A NOTE I I V-158C NOTE I I V-22C S2-1248-4 S2-5878-4 nV V-160 28 u D V-25B V-25D A I 6

~

iH7 y2 PX D u S2-5863-21/2 m t5 BY CNS/NSA BY PG&E W CASI NG 28 SEAL 267 SPENT RESIN SRTF nv 16 S2-3485-11/2 V

V-1 76D S2-3924-I V-88 S2-3/4 S2-2142-21/2

( I 64C-B I 34)

A6

&'h V

V-1 76B s

s-S2 ~

S2-3926-1 LT (278E-A I 33) I 057 14" U-2 RESIN SAMPLERS (DWG 108019)

S2-3335-21/2 RV-50 S2-3344-11/2 88 19

-c 19 S2-3920-1 1/2 STRAINER S2-3333-21/2 (274B-E I 33)

(ITT Yv-14D (278B-E I 33)

LT 28 14 DEWATER ING PUMP RETURN


..(S2A-C(

S2-5869-3/4 V-14B nv 16 RESIN SAMPLE RETURN IO t--- 86A-A S5-2 BW V-87Ml---t-r'---+----

STRAINER S2-3/4 V-51B S2-3483-11/2 S2-3336-11/2 3/4X42D u D nV 16 S2-3339-3 V-175B S2-3376-1 1/2 nV 16 V-175D S2-3377-V-I NOT S2-5878-4 S2-1249-4 PG&~*

i 6"

E H

V-55D P-0120 6

-{><}----

-A5 SPENT RESIN STORAGE TANK 0-2

-{><}----

&'h llf-2 DC-663270-40 NOTE 7 V-55B STRAINER NOTE 10 3"

NOTE 9

V-36B NOTE 12 u D PGE 2

I LOCATED FCV V-6B INSIDE H S2 1057 S2-3338-3 V-37B TANK ROOMI S-2 E s S2-3378-3 D

V-166 S2-3385-I1/2 S2-1588-2 83A LOADOUT l_jJ EDUCTOR 0-2 NOTES:

V-29

( 447M-E I 32)

ISOLOK RESIN 86A SAMPLERS l_jJ I, EQUIPMENT, VALVES, & INSTRUMENT TO BE PROVIDED BY CNS/NSA; PG&E PRO-VIDES THE PIPING, SEE DWG, 101935 INSA VALVE INVENTORY),( 80-E) 2,

'BW' DENOTES BUTTWELDED (ALL 2 LINES CARRYING SPENT RESIN TO AVOID ENTRAPMENT OF RESIN AT JOINTS!,

3, VALVE POSITIONS ARE SHOWN WITH THE SPENT RESIN STORAGE TANKS 0-1 & 0-2 IN THE FILLING AND LOADOUT OPERATIONS RESPECTIVELY, 4, PG & E VALVES WITH ITEM NUMBERS ARE SPECIFIED ON SPEC, 0722, 5, ALL PIPING ON THIS SHEET SHALL BE PG&E CODE CLASS H, EXCEPT ISOLOK AUTO SAMPLING SYSTEM, & AS NOTED, 6, AUTOMATIC RESIN SAMPLE COLLECTION DEVICES I PG&E CODE CLASS "E" I ARE LOCATED AT COORDINATES: ( 82 _A) 7,3/4"0 BALL VALVE,PITTSBURG BRASS CO, MODEL SPH-I3-BW-XXS 2/0ESL(83+89-C) 8, 2"DIAM, 3-WAY BALL VALVE, BW ENDS, PITTSBURG BRASS MANUFACTURING CO, MODEL NO,MP-H-17 BW/2 PO/CO/OE/IS FLOW PATTERN N0,2, 316 SS, ( 82-A) 9, 3" BALL VALVE PITTSBURGH BRASS MODEL #SPH-19-BW I IOI 2/0E SI FP, 316 SS, 10, SCH XXS, ( B3-C)( 89-C)

( 87-C) ( B4-C) 11, CHECK VALVE INTERNALS REMOVED. ( 85-D)( 87-E) 12, 1/20 PLUG VALVE,300# 316 SS XOMOX MODEL 0366 SW,UHMW SLEEVE IP-01201 W/ MODEL 60 ACTUATOR, ( 83-C) ( 89-C)

UNIT

\\i' ":

NOTE I ORA IN l'\\.IA ORA IN

'.-:3; TO 15~ 1 sH. TO AUX, MOTIVE WATER PPS FILTERS B4A REV

~"'

MISC,EQUIP,1_ 44'11-slBLDG, DC-663268-1 BYPASS I-cl PG O E

CO 020 9 A

B C

D E

~~

DRN,TK,o-1vvsuMP v

~

SHEET Sex PAGE O"

82

-*3N,..PG'"'IC---------------------------------------,,--------------------------"""T--------------------------r------....1-------"T'"....., ______...,_ ____

T"" ________

..._...._...._ __ ~

6/ I I /98 CMG9 BSG I KERS I J, DALAL MECHANICAL M I 6690 3/3 I /00 Revised pe, FCT 023040 1----A_T_E--t---W-N-+-R-E-t--I-V-t---=-p-=-R----:O-=F-=E----:S----:S--::-I----:O----=N-A-L----=-E----=NG----I N----=-E E=cR::-----t-----:P:-:E:--::D----=1----=s----=c----=.-----t-----:P::cE=c,,---------t-P::cE::--E=cX----:P::c.-------J