ML20268A794

From kanterella
Jump to navigation Jump to search
5 to Updated Final Safety Analysis Report, Drawing 102016, Sheet 18 Rev. 86, Make-up Water System
ML20268A794
Person / Time
Site: Diablo Canyon  
(DPR-082, DPR-080)
Issue date: 06/30/2020
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20268B299 List: ... further results
References
DCL-20-075
Download: ML20268A794 (1)


Text

180 E

D C

s;:i-B 0

N I

r--

N I

N 0

I- :zw 00 z

Q)

> -i=

+

12 a=>

C 0

00 a,

0 v oc m

CD CT>

I I

0

~

V=:J a,

(/J 0 er:

w co z A

--~

0 lj) 00 NW L II Q) er: 0 (JJ W N =:J f----

II VJ Z 0

<( l'.) <(

er: 0 U

INPGIC I Size I 8 I 182 ABANDONED IN PLACE LOOP SEAL FILL LINE 1-1384 S2-5085-3/4 S2-388-2 3 8 -B 26 >----tl><J-D<Jr-----o<J---,~

183 PRIMARY WATER MAKE-UP PUMPS m\\

V

~

184 185 27-D 13 SPENT FUEL PIT old(!) i'.5 I-z 0::

1-780 z:::i<

....,...., en D

Q. ::J 0::

(I) It~

12 0:: :::!

u.

~

I

~

N u:,

~

c/)

1-801 D

~-~

i2

a.

186 187 14 SURGE Tl<.

,...._J MAKE-UP (LCV-70) 188 TO MISC.

COMPONENTS S2-3451-1 1/2 ABANDONED IN PLACE N

I old'b 0

>-w

~old

  • in

<i=

(I)....

0::::,

z....

oo

~~

F.,....

cn I

..J

~o c,;i..J Oa,_

~

12~

u 189 TO STEAM N2 SUPPLY FROM PKG BLR N2 SUPPLY HDR N

c/)

~ -~BLIND FLANGE CONN. 'S co 0

a..

S2-375-2 S2-641-3 D

S2-3435-3/4 ~

w DIAPHRAGM 1-1 SEALED PRIMARY 9 WATER STORAGE I t--0<1--+ 2 3 4 - E 33 1-828 10 TANK 5

TO L 1-191, LS-473

---1n 200,000 GAL

& LS-472 AUX. BLDG. SUMP DC 663071 - 77 RECIRC.

SPWS TI 1 1---£>c::1--..,...----....;.;;=;.;.;;.;;---

1 t.._

99 4---""T""'-f 1-983 SERVICE WTR. HEAD TANK 1-1 MAKE-UP TO LT-41 I t--0<1--+ 233-E 33 LOCAL SAIIPI.E S2-1408-2 BY-PASS 1-820 26 _E 13 SPENT FUEL PIT (SFS) UNIT 1 S2-5161-2 1-821 187-E S2-5160-4 S2-4609-1 1-995 BY-PASS 1-992 FROM M.U. WTR XFER PPS DISCH 35-C 15 1-1S59

-------------><1--...------------4 FLUSH WTR 1----+,----c
><1-- 133-E OS BLDG. HTG. OR.

...___, RECEIVER 0-1 1-1579 S2 -4289 -1,"

S2-5162-3/4" TO CHEM LAB 1-1560 11 1-1947

---........ ----r--.J-___

il 1-1946 S-3/a" 1-1948 11 SAMPLE SINK 1-2 S2-5160-4

~

1-789 l!!,.,......._+I K-3730-3/4" S2-2837-1 02 CNO. POLISH DEMINS

~----.------.. CENTRIFUGE 106 -E 20 SEAL WATER

....,.,,==-~___,,,--==--;_-::..-:..-_-_--~.... ~

.... TO POST LOCA

'"-----SAMPLE ROOM

~

LO en

~

N c/)

I N

~

~

S2-465-4 FROM UNIT 2 199-D 0-797 0-796 TO FILTER RADWASTE RM.

0-590 s2-2 1 9-1 FOR RM. MAINTENANCE) 1 SPARE 1;

I CONN. S2-4446-2 AIR BOTTLE 1 S2-4447-1/2 7 4 -D 25 REFILL STA.

s2~1-iii\\3/4 :===::.::.:,':.

0 8

.. o,-2 85' ELEV.

s1c-D

,__....,.__S_2 -_3_7 5_7 --3/~4 ____,. S 4 C _ D 08

,___...,.._ __ ~- 5 2 C - B 08

_____.....__56C-E 08

..,_..,,,._-=-...;..;..;'-'-'".;:.._--, 5 4 C -C 08

___.,.._..., 5 5 C -D 08

_____.....__52C-A 08 BORIC ACID EVAP.

B.A. TANK DR.

1+-r-....-......... -

FUNNa I--_.,._""'--""'-....._~ 5 9 C - E 08

___________ __, 5 4 C - B 08 SYSTEM 1-1 08 B.A. TANK LOOP SEAL FILL o-678 o-683 s2-1..

3_11_-1/"'-'-~-

1--------,,.----, 5 I C-C 08

_..........,,........,._--uu11 s* a.

/\\ I

&L


1~140* EL 2


J 790 S2-3896-1 1/2 ------53C-B 08 I 02008 (zID 08 eves

..,.... ----~

08 QUIO< DISCS.

====::=oa:::::

FOR RESIN

~ FILL 08 cn CONTAINER 08 S2-1888-3/4 51C-D S2-3757-3/4 54C-D S2-1890-3/4 53C-A S2-1893-3/4 56C-E S2-1384-3/4 54C-C S2-1895-3/4 55C-D 08 S2-1891-3/4 53C-A 59C-E 54C-B BORIC ACID EVAP.

SYSTEM 2-1 U2-LINES UN IT

2. USED FOR EMERGENCY SPENT FUEL POOL MAKEUP. SEE AP-22 DO NOT REMOVE HOSE COUPLING
3. SHADED AREA ABANDONED EQUIP 4oPIPING IS SS SCH 40 THR'D SEE DWGo 224924 FOR DETA I LSo DIABLO CANYON POWER PLANT - PG&E CO" MAKE-UP WATER SYSTEM DRAWING SHEET PAGE REV 102016 18 0 86 01-27-2014 MNRU FxC2 KJD3 NOT REQUIRED NIA NIA NIA REVISED PER DFT-7*2459 f-----------+---f-----+-----+------------------+-------+------+------------<

DATE OWN RE IV PROFESSIONAL ENGINEER PE DISCO PE""

PE EXPO E

D C

B A