ML20268A706

From kanterella
Jump to navigation Jump to search
5 to Updated Final Safety Analysis Report, Chapter 3, Drawing 108016, Rev. 50, Sheet 17
ML20268A706
Person / Time
Site: Diablo Canyon 
Issue date: 06/30/2020
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20268B299 List: ... further results
References
DCL-20-075
Download: ML20268A706 (1)


Text

170 E

D C

l.[) B 0

N I

0 I

fYJ 0..

Q)

+

C 0

a, 0

v.c I'-- a,

_v7

(/J

  • V) wr-z A

--N 0

lj) **

co W L II Q) er: 0 U) w co =::J f----

II VJ Z 0

<( l'.) <(

er: 0 U

INPGIC I Size K-567-2 co -

I N

S2-1 I 7 I 172 173 174 175 I 6 11

\\£NT V

I

______ J ___________ J~g __

176 177 MAIN CONDENSER j;

2_676 K-121 -12 4 I -E 02 ~--.l.----..1aE.J..-_-..1.--t><J--'\\'J---lll 2

-3

-4 68 K-2741-4 160_0 ~-

2 1

427f----r-+,----,----i:

2

->c 6

J-75~----tll 14 CONDENSATE STORAGE TK.

2-1 NOTE 2

PKG. BLR FD PP.

- ~

I N

~

0 I

co Ct: sq-

-I N

I-

~

a.

w I,..,

a>

SUCTION UNIT I 61 2-1603

~

co -

G....,_--1~-I 8 SAMPLE co I

N SAMPLE SINK EL 100' AUX BLDG TO AUX.

ly-BLOG.

I" xO. 065J SUMP SS TUBING I

"'N TC 2-853 D

~....

N D

~:-:-:---:ir==~ 2-1939 236A-A 33 425,000 GAL 9

16 K-2124-4 2-703 2-1420 11 ri,--~~--;!~~[><lf----i><t--<.__!1_§6.§.8,:-CLl T

2-704 2-1830 2-73 TO LT-40 TO/FROM DEMIN. OUTLET UNIT I 2;...,154 7+1 ~

TO L 1-195, LS-479 5

13 6

1 15rll--C><::l-e-232A-A 33 D

52 _

1 LS-478 & LT-44

.._,~-ffl"'----Ei3'--~--'

2 1548 S1-1'/i S2-4551-2 K-380-I0[g S2-5196-3 CST 2-1 HYDRAZINE MIX PP.

2-1551 SI - I 2-1552 K-1900-4

--1--11 i

)-s2-1'/2 cl.

2-1554 I fE-i S2-5197-3 cl.

"j' N"'D

.., I 2-672 -ffi

~

co I K-1 N 2-1864 LOCAL SAMPLE K-567-2 et::,..,

.o 0 Q. :c Q.

31:d 0

u..~

I 0

<U sq-w a::

K-5020-2 K-5371-2 NOTE 3 co I s.o A 2 N

a d_ch a.~

a.F 3:U u

< (I)

I sq-K-2126-2 (ijl

~

2-1421 K-1917-4

~~

I t---ri.,.....;i D 2-1416 2-965 166-C TO/FROM M.U.

WTR XFR. PPS SUCT.

UNIT I SHADED AREA ABANDONED EQUIPMENT NOTES:

I. NOZZLES 9 & 12 ARE PLUGGED INSIDE TANK

2. NOZZLE N3 IS PLUGGED (BLIND PLATE WELDED INSIDE PIPE) AND ABANDONED LINE K-382-4 IS CAPPED AND BOTH ARE EMBEDDED.
3. VALVE 2-671 HAS A LOCKING DEVICE WHICH MUST BE REMOVED PRIOR TO CLOSING.

03-10-2015 ZNS4 FxC2 SWH2 NOT REQUIRED PER CF3.ID5 REVISED PER DFT-7*2867 f---------+-----+-----+-----+-----------------+-------+--------+-------------<

DATE OWN RE IV PROFESSIONAL ENGINEER PE DISC.

PE EXP.

2-4 Vii 178 UN IT 179 2

DIABLO CANYON POWER PLANT -

PG&E CO.

MAKE-UP WATER SYSTEM DRAWING SHEET PAGE REV 108016 17 0 50 E

D C

B A