5 to Updated Final Safety Analysis Report, Drawing 102011, Rev. 65, Sheet 2
ML20268A672
Person / Time
Site: Diablo Canyon 
Issue date: 06/30/2020
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20268B299 List: ... further results
References
DCL-20-075 102011, Rev. 65
Download: ML20268A672 (1)


Text

C Ol A

B C

D ro 0

N I

r----

1 N

"O 00

  • C QJ

~a

,o I

SJ"

-NVl o'Z N-N o-..

-OL 11 N

Q) er: 0 (JJ w -

J I-II VlZD

<U.'.l <c a::ou 20 21 IN&IDE= I OUTSIDE CONTAINMENT I CONTAINMENT 22 23 24 25 26 27 NUCLEAR STEAM SUPPLY SAMPLlt\\lG SYSTEM

--'--"--------'---=--==-----1

--~=--=---=--=-:.____:;::::::.=.;__::.::::=.=.!.-:...-:...::::__;__:_=-.:::_;_=..:.~..,,;.SA M PLE. ROOM OU T~I DE.

INSIDE.

I SAMPLE I-IEAi E.XCHANGERS ccw

-- SAMPLE. SINK. HOOD ASSEMBLY 28 29 7

NOTE I

)68-rlf4)

I t-lOTE I T.V.

..!:I m s18-4sv1 c K*2339*t~

I NOTE.

I - I

)337-E 132)

G-~

l NOTE T-F.C.

2~V2....+-,---~ j

  • 1721--

,)-~~.....,,;,.-;....;;.._., ___

c(), _____...,.;c~

9372A PRESSIJRIZE.1-1 STEAM 25V2 SAMP.LE. VESSEL.

ITl:,M.A.TSV I

°?>77A 9378A 25V2 E

45C5

/\\I

~

sreAM 9350A 5 -1013*3/a~P 9354A 3

SP,\\CE 3/e*TA.SSRL 3/s*TA58RL s-iYa 3/9-45 YI

~

PRESSURIZER r:iT,C-I L.'.J 7§]

T. V. r., ~ D

=Ve-4 5 VI ~

T. V.,..,,

RCG 3/9-45VI 32

>:,31-El~z>

51_~

1/e-4sv1 S-1674-3/e s-3/8 T.

8 s*Ye f.-C.

F. c.

T F. C...

~2-A 07 591:-""P~::-O--Oil(J-~-,...---.-

B 9~508 S*H,74*3/eYP 9~S5A 3

J!355e,

~i;;'l~ ~iAS8RL.. NOTE 1 7 3/4-TA'SSRL s-Vs va-TASSRL.,....,,---,

[fil_

3/s* 45V I

~

u D LOOP I ~~i~~L S-*1675-~1' P I

I r.,

T.V. r.,

. ~

T.C.

1/2-45VI 7§)

1/e*45VI s-.\\ 1..---.---

i.,

6 >337A*El32) s-7 8 HOT LEGS N0fE3 T.

F.C.

RCS S-167G-)sYP SIS NOTES:

  • D131,)

F.C.

135&A NOTE 10 S* 16 77-3/s ]'. P CONTAINMENT WALL I. SAMPLE. SINK AND HOOD ASSEMBLY SUPPLIED AS A PAC.KAGE.

)29-A) )29-E) )2&-E) )25-A)

2. 3/s' TUBING ADAPTED TO 3/4" NOMINAL PIPE AT VALVE.. 52?>-c)

.3. DELAY LINE FOR N16 DECAY IN 3/s PIPE TO PROVIDE A 40 SEC MINIMUM DELAY INSIDE CONTAINMENT. )21-B)

4. AL.L @) ITEM NUMBERS IN ii-IE SS. ARE SHOWN Wl,HOUT THE PRE.FIX. P.G,.&e. SS
  • REFER TO @) SiATUS REPORT.
5. ALL TUBING IS o/e O.D. E.XCEPT AS DE.TAILED.

E,. INl,..ET TO VESSE.L AT BOTTOM.

)26-A/B/D)

7. WHITEY SS-6NBS6*PK )23-B)
8. HEAT I:XCHANGiER.5 1*1

~ 1*2 ARI: 01:SIG.N eLASS lJ, QA Cl.ASS S, TO MAINT,l,,IN CCW SY5TE.M PRI:SSURE. 60Ut-lOAR'f INTEG.R.IT'f (24-A/5)

~. THE 1*3 HEAT EXCHANGER IS DESIGN CLASS II QA CLASS S TO MAINTAIN CCW SYSTEM PRESSURE BOUNDARY INTEGRITY AND ALSO TO MAINTAIN RCS SAMPLING CAPABILITY TO SUPPORT THE POST HOSGRI COLD SHUTDOWN LICENSING COMMITMENT. )24-B) ro. EXISTING VALVE 935,A WAS RE.PLACED WITI-\\. A NE.W VALVE UNDE.R RO. 706974 (SEE DC- &000235-81). )2\\-B)

II-SAMPLE VESSEL ISOLATION VALVE rs J/4" FEMALE.---~---,-....--

NPT SNOW-TRIK Vf>..LVE MODEL NO. SS-410-FP-STE )2.5/26-A/B/D)

I

12.

DELETED 3NPGIC 5 Size I, 3 7 I A I L...L..::..;.::;~......;:..J...J.

E DG-663214-11 53315A 9316 NOTE 11 25V3 s-1124-3/a I

Ls*t613-Y8YP S-1721-3/s E.

9314A 25 V.3 S-1131-3/a

/f---ABANDONED IN PLACE C7 T. v.

C7 14 ccw

&1-C 14 c K-Z~~S*l!i NOTE E, I - 2 9317B 25Y2 e

S-1125-3/4 S-1732-3/e NOTE 6 -~l--~--..

I-IOT LE.G NOTE 7 5-3/a 1*9360-A 25V2 3/B-45VI 5-3/a NOTE 7 5*4288*3/a E

1*9360-B 25V2 NOTE 9 tct2334-1Yz

'ZSl/2.

1-3 9372C 25V2 SAMPLE. VE.$SE.L s-4270-Y2 ITEM ATSV 3 YS,W-l.,_."'"':ll!'..,._-<~---.....i~E..._oao10-r+-..:..,

93"7OA

~-TSB 1 93 71 C

.. H:>1-1*

9~1'3C. OC*G63214 - I I 9~7SC 9316C S-1126 -1/e 2953v",.2 f.!OTEII NOTE!\\

2.5V3 S* 1677-3/s..___

S-4645-3/s I 9S14C NOTE 15 9369

  • t

~-,.~

S-7006-3/s

~E7 s-1686-~mP 1 7 1 1

9~106 I t I

AND HYDROGEN I

Ve-Tse I NTE.RIM._ _. I s-1123-!/6 ANALYZER POST LOCA 1---1;...;_.....,;.L_-c::'.>----*1. __

.....J ccw 87L-D 31 S-5976-':"

SAMPLING I

89-C 14

~

I

., HOT I

I/

~

SYSTEM I,("ilsAMPLE s-1022-,2 s-1021-1/21

( SEE SHEET4)

I 24A I PANEL I

I l,;:J I CSEE SHT. 2Al l L

_J 1--c.., 83L -D 3 I SC 126 9395 NOTE I 4 9386

[

RV-900 S-5978-1/4 45C5 45C5 9407 9408

> ) (s 110011 1;~

25A *E c:::::>-

FILTER EFFLUENT FROM HOT SAMPLE PANEL 25VZ 9409 E

S-1133-3/s S-5979-3/4 9362 45C5 -

9402 a 5 Y 2 _E_,..,.._

5 93&3 6 52 3/4-CS6 2-4452*3/4 GROS,S FAILED FU~L SYSTEM SAMP. RET. TO LETDOWN MIXED BE.D DEMIN.

eves 9381 25V2 I!

I 25v,, !

,,_/

25V.3

~

s-16,9-'}e IE)

---=~~>----------------tx:J-- -c:::::-----....,;------~*.... *i---------c::::-

................ ~

NOT~6-~1-_-,--~

~3~6 9372D VOLUME CONTROL TK GAS SPACS 2sv2 I asv2 SAMPLE. V~SSEL.

2_)4~5~B :J;-E~I 01§;8)).a..;§.*_.I !e1oi@ilf,7"--_~_ve.....,[E)lilii,l,, ___ -:" ___ 111111111::::::;))-txJ~--** -.-l)od,.....{)©1),.1 I TE.M ATSV 4 I

9:J73D OC.-663214*1 I VOL-. CONI-NOTE I!

2.5V2 S* I 688-3/4 TANK eves 9404 Q.

9397 1*

~L~l~U~lD~SF"PA_c,:_~:,_ _______..____

25V2

>4SB*D)O&,

--IXJi-----

Ts-4 ~ bO- ~

.I LC.I 9398 5-.597~ -r~/8 DEMIN.INLET 25V2 I

49-8 08 LET DOWN LINE DEMIN. OUTLET C,

9999 2.5Y2 s-%62-Y4 I

/11'---i...._.....,_. I 9sg1 zsvi I

I:

9'?190 25V2.

E S*o/s 9~14D 25Y3

  • S*16S9-~

9363 25V2 E S-1693-%

S-1693-s MAKE-UP~

WATE.R

-A CRINS!) 16 S-11~3-% E 9~86 45G5 B

F S*t914-\\

s~e,_

2SV2

( TYP 7)

E D

l E

I I S318!:!, j I 4sc.s I I I I I I E 5-1734-o/s C

9380 25V3 I

I l I

I I

S-3/4" I I 0 I j

I I s-3/4* I I 9384 25VZ 9385 25V2 E S-I735-3/4 I

SAMPLE RETURN TO VOL. CONTROL TANK 42B-D 08 eves L

L NOTE.I SAMPLE SINK 1-1 (NOTE NOTE l I

_J SAMPLE. SINK HOOD ASSEMBLY -- 9-400-.L_-2.-s-vz 5AMPI...E. ROOM. -

9369 I-X-420

_I_NSI0E I OUTSIDE

/>---ABANDONED IN PLACE NOTES CONT'D:

SZ-1642.-t(s],___ _

__.SH-4 19 DRAIN TO MEDT 0-1 13, THE CODE CLASS "E" TUBING FROM 9356B TO THE NSSS SAMPLE SINK AND PM-80 IS SEISMICALLY QUALIFIED TO ALLOW POST-EARTHQUAKE SAMPLING CAPABILITY AT THE NSSS SAMPLE STATION. (TI]>

UN IT

14. NUPRO SS-4TF-140 MICRON<18)
15. WHITEY METERING VALVE, MODEL SS*31RS4G 16, H

= ABANDONED IN PLACE BOUNDARY (CUT & CAPPED) CS-SPEC. U.N.O. l

17. INSULATION ON PORTIONS OF THESE LINES HAVE ADDITIONAL BANDS INSTALLED ON 3" CENTER-TO-CENTER <MAX> SPACING. SEE DRAWING 500048 FOR SPECIFIC LOCATIONS.
18. SAMPLE SINK 1-1 HVAC REFER TO 102023-11.<lB)

A I

~

t-1_2_-~l-;-7;:--;'--2 Oc:....:..::I 8=-t=Z~N~S-;-4 rF~X~C:.::2+N~/7A:.+N.:.:=O:-::T~R~E~QLJ~I R~E:..:::D~P~E R~C~F,.::3:_:,. ~I.::'..D::..5 +..-:-----1--.::_-+----=--___j Rev i sed p e, D FT - 7 *4 7 I O DATE DWN RE IV PROFESSIONAL ENGINEER PE DISC.

PE EXP.

SAMPLE.

~I RE.TU RN* TO

  • C. VENT HDR 24 GAS. WASTE.

':>YSTE.M DIABLO CANYON POWER PLANT - PG&E CO, NUCLEAR STEAM SUPPLY SAMPLING SYSTEM DRAWING SHEET PAGE REV 020 2

0 65 A

B C

D E