ML20268A529

From kanterella
Jump to navigation Jump to search
5 to Updated Final Safety Analysis Report, Chapter 3, Drawing 102021, Rev. 58, Sheet 5
ML20268A529
Person / Time
Site: Diablo Canyon  
Issue date: 06/30/2020
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20268B299 List: ... further results
References
DCL-20-075
Download: ML20268A529 (1)


Text

A B

C D

E 50 I

51 I

52 I

53 I

54 I

55 LINE DESCRIPTION UN IT I - I

  • uNIT I -2 UN IT I -3 AIR INTAKE
    • -2182-22
    • -2185-22
    • -2188-22 ENGINE EXHAUST
    • -2 I 83-20VI **-2 I 86-20VI **-2 I 89-20VI SILENCER EXHAUST K-44 I 3-22VI **-2 I 87-22VI "*-2 I 90-22VI CRANKCASE EXH.

K-2173-5IIIP K-2586-5l!IP K-2587-51IIP EXHAUST RISEN ORN K-4410-2 K-4411-2 K-4412-2 SILENCER ( EXH.)

K-4403-24VP K-4404-24VP K-4405-24VP EXHAUST SILENCERS UN IT I - I UNIT I -2 UNIT 1-3 RIGHT ANGLE STRAIGHT THRU STRAIGHT THRU DC-663082-13 DC-663082-26 DC-663082-26 INST. SERVICE INST TANK 1-1 TANK 1-2 TANK 1-3 TURBO CHARGER DISCHARGE AIR MANIFOLD FIELIEF VALVES Pl 822 RV 860 826 827 861 862 DC-663082-39,40

  • INTAKE ENGINE EXHAUST TO OUTSIDE OF BUILDING

~TYP.

r{K-4412-2 NOTE 8 K-441 I -2 LI+---[] ____ ---7 I

K-4403-24IIIP NOTE 8 rn I K-4410-2 EXHAUST DRAIN K-44l3-22Vl K - I 1/2 G-0627 ~*I1/2" NOTE 7 LJ D I

I I

I Q

  • EXHAUST SILENCER NOTE 6 DC-663082-26 DC-663082-13 EXHAUST DRAIN SEE TABLE NOTE 4
    • -2l83-20VI c::::=:>DC-663082-1 I COMBUSTION AIR FROM OUTSIDE OF BUILDING
  • AIR FILTER ~--*_*-~2~1Ts_2_-2_2 __

c~' SILENCER LJJ TURBO CHARGER


c:')I A FT ER V

COOLER DC-663082-22 NOTE 4 DC-663082-12 COMBUSTION AIR AND EXHAUST TYPICAL FOR THREE ENGINE-GENERATOR UNITS.

2021S5.MOI 12-6-95 \\:00 RJN HOM£3/... DC3.FMT 5/94 I

I I

I I

I I

56 I

\\

K-2173-51IIP I

4 II I

DEG I - I 8, I -2 ONLY A I

,57, 57 I

58 I

59 NOTES:

I. INDICATES PG&E PIPING CODE CLASS

2.
3.
4.
o.
  • DENOTES MANUFACTURER SUPPLIED INSTRUMENTS AND EQUIPMENT.

IT IS ACCEPTABLE TO REPLACE MANUFACTURER SUPPLIED INSTRUMENT TUBING WITH PG & E SUPPLIED S-SPEC STAINLESS STEEL TUBING

[J MANUFACTURER NUMBER IDENTIFICATION

    • PIPING TO BE INSTALLED UNDER SPEC.871 I & PROVIDED UNDER DC-663084-1 MOUNTED ON ENGINE CONTROL PANEL @9 DIESEL GENERATOR EXHAUST SILENCER SEISMICALLY QUALIFIED FOR HOSGRI CRITERIA. EQUIPMENT SUPPORTS FOR THE DIESEL GENERATOR EXHAUST SILENCER SEISMICALLY QUALIFIED IN ACCORDANCE WITH DESIGN CRITERIA

'IEMORANDUM M-72

', THE MODIFIED DRAIN PER AS-BUILT CONDITIONS IS APPLICABLE TO UNIT 1-1 ONLY

3. PG&E CODE CLASS J PIPING HAS BEEN DESIGNATED AS DESIGN CLASS I FOR HOSGRI SEISMIC QUALIFICATION PURPOSES ONLY. THERE ARE NO SYSTEM DESIGN REQUIREMENTS FOR ISOLATION VALVES TO ISOLATE CODE CLASS J PIPING FROM CODE CLASS E PIPING
  • , CRANKCASE EXHAUST TO
  • OUTSIDE OF BUILDING CRANKCASE EXHAUST TO INSIDE BUILDING VENT TO ATMOSPHERE OF (I 4"
  • ' WALL 4

~/

~

K-2587-51 I IP

-~

~WIRE SCREEN BETWEEN FLANGES VENT TO ATMOSPHERE

@]

[I DEG I -3 K-4 K-4 DIESEL ENGINE I -

I DC-663082-2 ONLY

[TDPGJ PI 822 NOTE 5 DC-663082-42

' - - - r - - - ~ -ill SYSTEM EXCEPT AS NOTED UNIT I

P.G.&E. co.

DRAWING NUMBER REV I 02021 58 SHEET 5 OF SHEETS I

(s~i.N 1 it (K. i l I MICROFILM I

A B

C D

E