ML20268A525
Text
C Ol A
B C
D a,
0 N
I N
0 I
N u
- C Ql
~E I
0 I'-
I ST N"'1Vl o'Z Nl'-N ON.*
-OL 11 N
(I) 0::: 0 U) w -
- J f--
II VlZO
<(0<(
o:::ou 30 31 32 NOTES:
I.
- 2.
- 3.
- 4.
- 5.
- 6.
- 7.
- 8.
- 9.
I O, I I.
I 2.
I 3, I 4, I 5.
I 6.
I 7.
I 8, I 9.
- 20.
21,
- 22.
- 23.
- 24.
ALL PIPING ON THIS SHEET SHALL BE PG&E CLASS "E" ALL PIPING TO BE "K" SPEC. UNLESS NOTED COMPONENT COOLING HEAT EXCHANGER SUMP DISCHARGE HEADER LINE 2986 TO SLOPE DOWN LIQUID RADWASTE@]>
TO BE USED ONLY AS STANDBY@])
DELETED K-5728-4 INSTALLED TO DRAIN FW HEATERS. HOSE REQUIRED TO DRAIN INTO TURBINE BLDG SUMP, 3"-150* FLANGED SWING CHECK VALVES, PACIFIC VALVE FIG.NO. 180-12H-CF8M OR EQUAL.
DELETED 4
11 C. S. 150# PPL PLUG VALVE 4" C.S, 150* FEP LINED 2-WAY PLUG VALVE, TUFLINE MOD.
4" S.S.300* CHECK VALVE, CHEXTER FIG. 1603-C <WAFER) 3/4" REGULATING VALVE, WHITEY, B-IKS6 OR EQUAL~
4" C.S. BUTTERFLY VALVES, TEFLON LINED, 150" RATING, POSACON PART *NTI00-4-SPI-BPI-GEI-FA-I-A (WATER TYPE) 061 I" C.S.PLUG VALVE, POLYPROPYLENE LINED, ANSI 150* FLANGE RATING DOW MODEL 0602011 3/4* HOKE, MODEL N0.3852 G 6Y NEEDLE VALVE 1/2" REGULATING VALVE, WHITEY, MODEL SS-7VS8 1/2", 3-WAY BALL VALVE, WHITEY, MODEL SS-45XS8 CAP IS ORIFICED TO PROVIDE APPROX. 2 GPM MIN. FLOW AND TO PREVENT SEDIMENT BUILD-UP EXTEND PURGE LI NE BELOW SUMP LOW WATER LEVEL. < SAME AS UN IT 2 l VELAN MODEL O I I 4C, S/C 76-5333 ~
CHECK VALVE STOCK CODE 70-0968 <TI:Q) 1/2" BALL VALVE, WHITEY, MODEL SS-45S8, STOCK CODE 72-9690.
1/2" BALL VALVE, WHITEY, MODEL SS-45F8, STOCK CODE 73-0154.
PORTIONS OF LINE ARE AL-6XN MATERIAL SCH. 40 PER NMOD 60025381.
25, VALVES ARE WELDED LADISH ASTM A351 -CN3MN GATE VALVES AND
--PIPING IS AL6XN PER NMOD 60088205. ______ _
~2§~_U!-I~A_S9~LC_f~QlfM_EJ~~Jl!_LS_l~~:TMOD PER 60123865 1:G'.
NEW RENTAL PRETREATMENT BRINE REJECT VENT S-1/2" 1/2"@
HOSE i-G-0283 l-+--1-J G-0283 I TBWP 1/2" 0-,---,--L---j -"\\.r-1/2 11 HYDROCYCLONE SEPARATOR (TYP) 3" x 2" SWAGE 52-2" REDUCER MTR PG&E I - I 5-1/2"
___l_
,........._<_I _-_2_l -'----+-------+-----:;:::~
COLUMN t=='.J~
BEARINGS (TYP 5)
_1;4 11 FLEX HOSE (TYP 5)
~
I I
I 76
-A 16 MAKE-UP EVAPORATOR E-6106-3 SLOWDOWN 20
-E 16 F-2768-4 SALTWATER EVAPORATOR DRIP PUMP I OVERBOARD 49
-A K-1/z" E-4" E-3" E-4" V
r7 16 G-0627 K-2785-4IIIP ffi c.::,
z Cl...
Cl...
0 w 0
0 w co
- E w
33 34 35 36 37 EFFLUENT K-2985-6 EMBEDDED PIP I NG n
r--------------~~~----<=-~;;;.;;:.;;:.,..;;:._ ______ ~~~...:...:,;~~-----LJli--------
- ~
ABANDONED IN PLACE I
I I
TBS-1-79 I
TRUCK FILL I
r, I
I I
TRUCK FILL I
(AT CREEK)
I I
r, r----------,
4" CIVIL MECH I
I 611 611
~, -~---~---~---:I
- wASTE POND:
6,,
I L...J LJD I
SAMPLE (REMOVED)
( AT CREEK l
~-------------------------------------~
5-3/a" P-0201 REVERSE OSMOSIS SUMP PUMP M
139
-0 SEC.CHEM LAB DRS CNDS POL SUMP PUMP I - I I -2 M
M 179 179
-c
-c 02 02 1 TEM 21 DC-663323-1 V-0673 (ill)
-~ K-2271-2
[-E---4-5_9_7 ___
2-+---'
G-0219 TO & FROM WHAT TANKS Fl -5932-3 33-E 27,--.--+----------------J U-2 TURB 32 BLDG -E SUMP 27
"'1
"'1
"'1 I
LD
"'1 l'-
"'1 I
20
-c 16 s:r I
co I'-
"'1 I
LL 40
-c 52-4 40
-8 NOTE I I 53-4 LCV 449 Fl -5601 -4 SALTWTR EVAP 45 BAROMETRIC
-o CONDENSER DR 16 FROM U-2 SUMP PPS Fl -5600-4 NOTE 14 FI -4
~
NOTE 10 G-0284 NOTE 9 Fl -2970-3 NOTE_ l~OTE 25 7 (illg)
NOTE 25 NOTE 52-3 7
52-4
@ill)
S2-4523-3 I "
1-+-11.,.__J V 52-5442-4 NOTE 24 111
,__5_h LD N
w l-o z CIVIL MECH I
"'1 co a,
N I
"'1 I
ST l'--
- 0)
N I
~
K-3 S2-3"
~
S2-4523-3 NOTE 24 69-0 L..J K-1 S2-3" RV 555 r,
ST I
LD a,
LD LD I
N Vl TO
~
R-0183
.--a~1--r+-------AIR
~
I N
Vl R-0183
~
I N
Vl RETENTION 2
'? S2-3/4" 0::
FI -2973-4 TANK 0- I co 1------1 ~I S2 a,
R-0183 R-0183 S2-3/4" R-0183 S 12-1" R-0183 L.J D 1/2" 38 39 s-3/4" SAMPLE SINK S-3/4" 246 INSTR AIR 25 PCV 2108 SAMPLE ~r-=J COLLECTION TANK 45V3 S-1/2" OVERFLOW TO FLOOR DRAIN L..__ _ _ _
L _
_J SAMPLE RETURN PUMP NOTE 15 1670-A (277-E I sv 1551 OILY WATER SEPARATOR 0- I DC-663251 -8 45C4 I "
ADJUSTABLE FLAT CONTROL WEIR--~
ADJUSTABLE FLOAT SKIMMER DRIVE S-1/2" NOTE 23 s:r I
co a,
l'-
N I
LL COND POL SYS WASTE WATER TRANSFER PPS DISCHARGE M
169 52-4 26
-B 16 WEST SIDE IEL. 120' CTYPJ IEL.105' r
55 GAL. DRUM EL.85' LD LD I
N Vl 0-94 1-F_1_-~2=s:9_1_8_-_4____ _ __.,.
1 *A 11/2" INFLUENT PI PE~
w r---
2 Fl -4846-3 323-B 33 LS 449 0...
l=l I
l'-
"'1 I
I -
I.. -
I I_ --,
I
\\
I I
I i
\\
I
\\
I I - I I -2 SUMP PUMPS
( SEE DETAIL "A")
EAST SIDE K-5728-4 IEL. 120' CTYPJ IEL.105' C-0651 OIL TANK OIL SKIMMER EL.70'6" K-2984-6 G-0219
- 5. C.
SLUDGE POCKET S-l/2" B-0102 r---
CT>
N K-2980-6 5-3/4" S-1/2" STANDPIPE DIST HX SHELL RV-17 OUTLET L.J LOCAL SAMPLE l:-
SCUPPER BOX EMBEDDED
<SEE DRAINAGE E L
- 5 6 ' - 6 " ---=-----=-----=-----=-----=-----=-----=-----=-----=---_---=-----=---
DWG.500116)
UNIT I TURBINE BLDG SUMP FLOOR DRN ~
RECEIVERS 19 62
-E K-2986-3 L..J THREADED CAP WITH 1/a" ORIFICE NOTE 18 DETAIL "A" NOTE 19 TBWP BEARING LUBE WATER SYSTEM (TYPICAL FOR TBWP 1-1 & I -2) 3NPGIC 3 Size TBWP I - I Pl-41 IA Pl-412A Fl-184A TBWP I -2 Pl-411B PI -4 I 2B Fl-184B
~
CIVIL NOT EMBED NORTH PIT UNIT I TURBINE BUILDING SUMP SPEC 8724 FROM ATMOSPHERE (STAND BYl
- FLOTATOR AIR COMPRESSOR 0-1 FLOTATOR AIR FILTER NOTE 4 RV 276 52-1/2" D[__..,~
40183
~
FLOTATOR AIR RECEIVER 0-1 DC-663251 -6 PCV-97 TURBINE BUILDING SUMP OILY WATER SEPARATOR
<MAXIMUM CAPACITY 100 GPMl G-0627 MUFFLER C-0656 SERVICE AIR 1---1 2_-...co-=2=----=2=--0_1....:.9--1-=z...cN...::.S_4-I--F_X_:_C =-2.J...-N_/_A'--J..'.NC...:O:....T __
R-=E=-=Q-=U....:.lc._R-=E.::.D--P.::.E'--'.R _C.::...F:....3=--*:.....:....:I D:...:5:.__j__ ____
___j ____
..L_ ____
_J R e v i s e d P e, DDT - 4,. I 9 0 4 DATE DWN RE IV PROFESSIONAL ENGINEER PE DISC.
p E" PE EXP.
K-1/2" 52-1/2" R-0183 I "
G-0627 PORTA (OFF SIT BLE PUMP E DISPOSAL)
--:1---...
t---...,----'-+----.-------+-' UN I T 2 I,
I r"\\
\\
CIVIL-6" K-2987-3 TEMP HOSE I CONNECTION I
l/1 l/1 I
I I PORTABLE, - ' I I
PUMPS (
I I
I i=--,,....---,-
"SLIDE-'.. sc*.
~GATE :-:.. ~-
'-=- VALVES ~c.
SLUDGE BOX 0-1 CIVIL DWG 438307 MECH DWG 500 I 16
~CIV 1*
- EMB
- sE 88
,CB IL -4" EDDED E SPEC 31 Y CIVIL)
CIVIL 6" OVERFLOW TO BLDG SUMP WATER DR AW OFF TO BLDG SUMP OILY WTR SEP HOLDING TANK 0-1 DC-678610-1 COMPONENT LJ N I T COOLING HX SUMP 1-1 DIABLO CANYON POWER PLANT - PG&E CO, OILY WATER SEPARATOR AND TURBINE BLDG. SUMP SYSTEM DRAWING SHEET PAGE REV 02027 3
0 53 A
B C
D E