ML20268A502
Text
A B
C D
en 0
N I
"1" 0
I C
r--,
01 0
"IJ
- C **
o OlQJ
~E I
I r-- <( "1" t"") V) 0,z Nr--N o-..
-OL 11 N
Q) er:: 0
(/)
w-=i f--
II l/lZO
<(C)<(
cr::ou 30A 31A 155A-E 34 32A 33A INTAKE STRUCTURE NOTE 2 II YARD TURBINE BLDG.
........-------'--'-----=----------t*_..... i------:=-----==----=----'--=-----==--=---
NOTE 3 MECH. SEE DWG. 500153 34A 35A E-1049-2 E-928-2 E-3/4" 8l 1-227 32 1----------r--~~I------I FCV-502 18 23 R-0107 I -45 31-E 15 7
I - I 36A r,
B-955-2
_© NOTE 16 G D
~ G-715-20 18 B-0 I I I 37A UN IT-I MAIN CONDENSER DC-663041 - I D-715-20 38A F-1881-8 E-2 3/4" R-0109
,.....,-E -I1/2 39A E
MECH NOTE I I CIVIL 2"DISCH TO OCEAN
~.D INTAKE STRUCTURE
~
SUMP PUMPS DI SCH
( 154A-AI 34)
EMBEDDED I
G-534 _20 G-710-20 R-0107 u D Du R-0107 NOTE 15 HEADER 22 39 -D>--'-G_-6_7_7_-_I 6--'----~------------------------l~f--l,-,----I _2_" _A_C_P_B_Y_C_I_V_I_L--1---.---l
_6_" --------il~t------1,;x f--______
G_-_9_5_4_-_I 6 __ _
B-0111 f
~
B-0111 FROM INTAKE CLR 62 63
-D
-D CWP 1-1 MECH SEAL 3
I.
~
SERVICE WATER E-3/4" HEAT EXCHANGER UNIT 2 E-929-2 B-0 I I I SERVICE WATER HEAT EXCHANGERS DC-663012-1 E-1050-2 r,
B-984-2 l-44 R-0107 TE D-2093-14 D-2226-10 D-2227-10
~
~
CIVIL-20 NOTE 6
( TYP. l F
E 1-226 FCV 503
~
<fil>
~
NOTE 12 18 MECH. E CIVIL SI E-4519-2 9
r---~~'--------'--------j~t------1
( 424[ -A I 32) 2 3 1-2
~ G - 7 I 6 - 2 0 B - 0 11-, I -'I--------:- l--"-
~-- b
- o~**
l::i ~~
- P, b*. b
'oC:_*.
b ~~
- P, b*_ b THRUST
- RINGS B-0107
( TYP. l -----~
I - I
'. 0: *;..
. *,v..
,.*. [7 * **
B-01 I I SI -4
~--------lil I
( 422D-A I 32)
M
- FCV-491 BY CIVIL PI TOT TUBE
( TYP. l NOTE
-13 MANOMETER CONN ( TYP. )
NOTE 5
' l
' I CIVIL 18" NOTE 14 ll.75'x 11.75' BY CIVIL G-711-20
- ....©.=:
A I C0j ~
NOTE 20 D-711-20 NOTE 20 12'x 16' BY CIVIL D-2092-14 V
V-0167 R-0107 u D Du 18 R-0107 1/2" ( I D ) x 1/s" ( W )
TYGON TUBING~~
(PVC CLEAR) u.l u
a:,
I NOTE 18 >
S2-3/'.
NOTE G-2224-10 I NOTE 18 l CIVIL-8" NOTE 7
( TYP. )
- o~**
b ~~
- P, b". b
- o~--
t:a ~~.*.
-*- b
.. *. [7..* - -
CIRCULATING WATER PUMPS DC-663021 NOTE CIVIL-8" NOTE 7
( TYP. )
I -2
- o:*.;.,
.. *. r,:,"':-
CWP I -2 (1 MECH SEAL 68A
~
E-4520-2 B-0107 SI -4 E MECH.
SICIVIL C-0253
,r+-----1 I F 2 - 3 8 3 6 - 4 F 2 - 7 0 8 -4 56 -D 60
-E F2 _3836 _4 CHLORINATION CWP MOT CLG SYS C-0253 SYSTEM G-2225-10 CIVIL 108" G
( TYP l
( 424D-A I 32)
M
- 61
-E FCV-492
~-+--BY CIVIL 1!
~:;:i I I 183-E 35 TE I I 11
~
254-E 33 /'-----"
I I NOTE 17
'---... ------I 11 11 11 11 J,L NOTE 13 34
-B 11.75' PIPE BY CIVIL,
( TYP. l (33B-A)
- 6.
- 7.
- 8.
- 9.
I O.
AIR RELEASE HEADER UNIT 2 NOTE 14
~
IB-o 1 1 1 D-2091 -14 A I 102
~
~
NOTE 20 D-710-20 NOTE 20 V-0167 55-B 02 NI V
( IOIA I
I 8-0 I I I
'----T-,c=,-~-1_-_l_~-----rcc=r--' I 2" I 9
~ y N5 N5
~
D CONDENSATE oc~tifii8-_2--~
COOLER DC-663042-1 V-0167 V-0167 D
y
,.-----f-lTEM I 21 'X 14'
( TYP. l DC-663318-2, 9, I I I TYP. )
I " ( I D ) x 1/s" ( W )
TYGON TUBING (PVC CLEAR) 12' x 16' BY CIVIL I I. 75' x I I. 75' BY CIVIL CIRCULATING WATER SYSTEM 3/4 NOMINAL WALL WELDED STAINLESS STEEL ASTM A358 TP316L, CLASS I I ( 33A-B)
TO BE FURNISHED UNDER CIVIL SPEC. 8842 (30A-E)(30A-C)
NOZZLE 71 INLETS AND OUTLETS CAPPED.
WHITEY SS-63TSl2 (3~-C)
DELETED 18, THIS LINE MEETS MATERIAL REQUIREMENTS OF PG&E SPEC "S2" BUT IS SCH 80 FOR STRENGTH AND TO ALLOW THREADING. REF AT-MM AR A0567627. ( 37A-C)
BUT IS SCH 80. (37A-C)
SW ITEM3(TYP.)
DC-663318-1,9 15' X 9' I I. 75' X I I, 75' CIVIL--~
" VENT CIVIL E-2 NOTE I I CIRC WATER SAMPLE 2"
R-0109 y4 II 3/4" TYGON TUBING I - I A SUMP 0-1 CIVIL DWG.
438131 TE-16 T 2403A IO'(TYP.)
NOTE 8 u.l u
( I 53C-E I 34)
DISCH GATE 7
E-2 E-2 I-1/2" PVC CIVIL 6" OVER-FLOW TO OCEAN GUARD PIPE ----11 FROM UNIT 2 UNIT ONE &
UNIT TWO CONTINUOUS CHLORINE MONITORS (LEASED)
DISCHARGE TO OCEAN ffi MANUALLY ADJUSTED WEIR K -3/~"
DISCH GATE 32 I I. 75' x I I. 75' CIVIL S-1313-1/2 E
TO OCEAN
---ill COND PPS DISCH HDR 108017 UNIT 2 I I
- I 2.
I 3
- I 4.
2"0 PVC BALL VALVE, UNION END TYPE, SIC 75-4713 (39A-A)
BL I ND SECT I ON OF SPECTACLE HAS BEEN REMOVED ( 32A-B)
FOUR CATHODIC PROTECTION TEST STATIONS (32A-C)(32A-D)
REFER TO DC-6009321-5 FOR DETAILS ON FLANGE CONNECTION FOUR CATHODIC PROTECTION TEST STATIONS EACH CONNECTION LINED WITH CURED-IN-PLACE PIPING FROM CW TUNNELS TO FIRST FLANGE K-2635-10 L-------~;'.)-~.l----+--....:.:..-=-:=-=-::__:_::_ ______
57 -A 02 18 VENT 15 ' x g* CIVIL MECH.
COND PPS 3NPGIC 3 size
( 30B-A)
NOTES:
I.
FOR RUBBER EXPANSION JOINT, SEE DC-663323-18(30A-C)
- 2.
VALVES IN THE INTAKE STRUCTURE WITH PG&E MARK NOS. ARE FURNISHED BY SPEC. 8749, UNLESS OTHERWISE NOTED ( 32A-A)
- 3.
VALVES IN THE TURBINE BLDG. WITH PG&E MARK NOS. FALL UNDER SPEC. 8711, UNLESS OTHERWISE NOTED (33A-A) 4, DELETED
- 5.
ALL VALVES, TUBING & PIPING BY CIVIL, SEE DWG. 438103(33A-B)
I 5.
I 6.
I 7.
( 34A-C)( 34A-D) 2" 150# PVC TYPE #346, STOCK CODE 75-4713 (39A-A)
USE PIPE SPEC. "B" TYPICAL FOR ALL VENTS, DRAINS AND INSTRUMENT TAPS FOR 1-1 AND 1-2 SERVICE COOLING WATER HEAT EXCHANGER CHANNEL HEADS ( 36A-A) ( 36A-B)
INSTRUMENT ABANDONED IN PLACE.(32A-B)(32A-D)
A I 102
~
03-04-20 I 9 ZNS4 FXC2 N/ A NOT REQUIRED PER CF3. I D5 DATE OWN RE IV PROFESSIONAL ENGINEER PE DISC.
IN TURBINE BUILDING. CREF:6033093)
SPOOLS TYP.-__
DC-663028-I 12" UN IT Revised Per DDN-2*1853 PE EXP, BY CIVIL DISCH HDR C-0244 DIABLO CANYON POWER PLANT SALTWATER SYSTEMS PG&E CO, DRAWING SHEET PAGE REV 020 7 3A 0
02 A
B C
D E