ML20268A450

From kanterella
Jump to navigation Jump to search
5 to Updated Final Safety Analysis Report, Chapter 3, Drawing 108003, Sheet 3, Rev. 81, Feedwater System
ML20268A450
Person / Time
Site: Diablo Canyon  
Issue date: 06/30/2020
From:
Pacific Gas & Electric Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20268B299 List: ... further results
References
DCL-20-075
Download: ML20268A450 (1)


Text

E D

C B

cD 0

N I

en I

en 0

J J,,-

I

  • 1 30 31 IK K.

694 8111P 3 0 -A O 2 6 9 1------"----'-----'---"---1 REC I RC TO CONS ENS ER

<3o-AI 02) 69 (v, 130131 s111P) 36C-A 36 FT 15 32 FCV-53

"----T-~(35B-E I 36) 6 II c---'-~

FCV-54

"----T-~(35C-E I 36) 511 2e (f\\16 552 8111P T

30 (33C-A I 36).

START-UP

,-,i 3,

SEE l*IOTE 8

~.12-;4" SPEC 1363 5

FE 33 PLUG

~STRAINER 1----'---"-----,--,------L-~-,------, ~

1------,-, ---

IKl2 504 24III I

II I II r LI 11 33 34 (252B-A I 35) TE 930 35 SPEC 1274

( TYP FOR 6 ~

I& 54 g,G,1546 11sfiD-rn-v 1(

!OJI K\\" ISC3'3 30

~-m~~

RO

<35-B I 34) 60 I

Cl9

.-....,tr,..J-,,-.IX:~r-o--fNI 2-IA I Cl3 D

L!J O

DC 6'73056-111 GD(o'J.1 l.!J Kl6 I~

(TELLTA.L-E TYP.FDR 3) p \\,-,.V (32-CIOS) 208 2-18 (32-BjOS) 2-1 C 36 D

LL

~~ LL pj0 419 37

=

Lf7 Ln I\\IQT E 12 f-llOTE 13---=i\\ I ;= "'

37-A 36 N

ttl m

e-----_,w <(

f---

,J

-A 36 o -

z~

NOTE 10 NOTE 7 38 39 kl6 5260 61Jl ( 3BB-B 135)

TE-C'"

  • I I 89 -

I I 89A 0

FE 1----T-r-'----:> 4 0 -A 530 31F-A 36 (35B-B I 35)

(K I 6 I 5 5 6 I 1 6 IJl )-\\

TE -

\\ I I 90-31 F -A 36

\\1190A

\\

6 ",If FE 2

2C NO TE "'@@r-_.______,-1,::--, --,-~-+--~--,----,-----r7 5 LJ O t----r"-r"-----7 4 0 -A (i0627 K" l7 540 l7 L t!OTE LJO LJO 13 K 154063 33 VI l<fG V

,7 M:JTe 7 (K I 6 I 5 5 5 I I 6 IJl )-.

31D-A 36 IJOT E I 3 6" 31G-A 36 78-E 36 306-6 35 TE-I I 9 I -

I I 91 A FT*

31E-A 36

~____,

TE-I I 92 -

I I 92A 521 ~

D TE 2A I

') (1 II f(l250424III L NOTf(o TE 2B Tl-~35 T22SIA (54C-B I 31)

(K16I %DZ) 310-A 35 r.12 501 30III 31-E 34 PT 156 8 9 -B O 2 >-a~"----'-------,--j L_J 35-E 35 92-E 02 FROM Fl-1916 PX 3

28

<34-E I 34)

D /

T>'.

L_J L__STRAII\\IER FLUSH CO ~J ~J K 16 552 8IIIP FWaHTRS 2-A 9 B&C FEEDWATER PUMPS 0C-653055-I & 5 T

29 OUTLETS D

L_J Kl2 503 24III 36B-A 36 FT I LI V

STRAINER FLUSH co~1ri -\\

7., i 11

--7 4 PIPE PLUG I

II

\\

<33B-A I 36)

PS 155 1D FE 32 LI II f--~~-~~~~__,

H I+1/4--

G-0323 L_J I

II (36B-A I 36)

D FROH 92-E 02 >------,

Fl-1917~-~~

l*IOTES:

I, ALL ISOLATION VALVES ON THIS SHEET WITH PG&E MARI< 1*10, SHALL BE UIIDER SPEC 871 I I KELLOGG I EXCEPT AS IIOTED, ALL PIPING ON THIS SHEET SHALL BE PG&E CODE CLASS E ALL MAIN FEEDWATER AND FEEDWATER BYPASS PIPING FROM THE CODE CLASS BREAK CHECK VALVE TO THE G-LINE ANCHOR AT THE TURBINE BUILDING WALL IS SEISMICALLY AI\\IALYZED, 3, ALL VALVES WITH ITEM 1'10, SHALL BE UIIDER SPEC, 8762 EXCEPT AS IWTED, 4, VALVES FCV-510, 520, 530, 540, 151 0,

1520, 31*P:OIC 3 Size ARE O SAFETY RELATED DESIGN CLASS I, Pv "

2 T

27

/

411\\'\\

DI/

\\,

,...,o LSTART-UP

\\ L II TE I B LJ STRA I IIER

\\

i SEE i')OTE 8 I \\

33-E 35 TE

(},1215o3l24III) NOTE 6 I A {,---~~

(31-E I 35)

S, SC-70 IS DESIGN CLASS I I AND SEISMICALLY ANALYZED IN ACCORDANCE WITH DESIGN CRITERIA MEMORANDUM M-61, Q9 6, FEEDWATER PUMP SUPERVISORY II\\ISTRUMEIITATIOl1 SHOWI\\I OIi I 08020, ( 33~s1c) 7, VELAII VALVE PER PO 4R-67229 IDC 663317-173-1 I, 8, START-UP STRAIIIERS TO BE 11\\ISTALLED AIID REMOVED AS I\\IEEDED, REF PROJECT FI LE 20 258 5,

( 32~B;C)

KIG53&~Jll FEEDWATER HEATERS 9, SOME Kl6 PIPING SECTIONS AND/OR FITTINGS HAVE BEEII REPLACED WI TH AL TERIIATE C2)

MATERIALS TO REDUCE EROSION/CORROSION OF THE PIPING, SEE DWG,500562 FOR DETAILS, I 0, BORG WAGIIER VALVE PER PO 4R 67228 IDC 6000235-42-1 I, 11, LATERAL BRAIICH I, D, CLAD WI TH IIKOl1EL, c::=)

12, BRANCH CONNECTION 1,0, CLAD WITH INCONEL

REF, MMD M000039-I, (IT])

13, PIPE SECTIOI\\I COIHAII\\IS A MIIL OF 0, IO;;

CHROMIUM,

,0-_

6-L

,r-~

-J 05-19-2016 Z11S4 FxC2 1,uA f)OT REQUIRED PER CF3, IDS ABANDONED IN PLACE-~

D "52.AA 3 SE.GON 5AHPL.lt,,,

51'eTEl"-1 G-09018 K.1,-83b 12 Ii P FCV-ISIO /NOTE.7

""'°7, --......... ~-

G~l 2 II D [~~


j I

v~*~-----+----v-"T" FCV-4 G-0627

\\

I YG-0901B DRAIN l~lsl 30-A*OZ.

MAIN CONDENSER 2

IlZP

f'(P FOR4 2

DIABLO CANYON POWER PLANT - PG&E CO" FEEDWATER SYSTEM DRAWi J\\IG SHEET PAGE REV 08003 j

0 8 REVISED PER DFT-7*3695 E

D C

B A