Text
_
PECO Energy Fuel and Services Olvision PECO-COLRP2012 l P2012 Core Operating umits Report Page 1, Rev.4 l
CORE OPERATING LIMITS REPORT FOR l
PEACH BOTTOM ATOMIC POWER STATION UNIT 2 I
1 RELOAD 11, CYCLE 12 REVISION 4 4
Prepared By:
/'"""'I I' 0' 9 I Date:
A. b. Giancatarino Engineer Reviewed By:
Date: V/(/9(
V
/(
J.J.Tusar Engineer Le~M Date:
7MP
~'
Approved By
.a J. M. Carmody Manager Nuclear Design Branen 9906300089 900623 PDR ADOCK 05000277 l
P PDR.
l
PECO Energy Fuel and Services Division PECO-COLR P2CS3 l. P2C12 Core Operating Limits Report Page 2, Rev.4 4
LIST OF EFFECTIVE PAGES Page(s)
Revision 1
-l-1 - 24 4
l l
l I
PECO Energy Fuel and Sennces Division PECO-COLR<P2C12
[ P2C12 Core Operating Limits Report Page 3, Rev. 4 INTRODUCTION AND
SUMMARY
This report provides the following cycle-specific parameter limits for Peach Bottom Atomic Power Station Unit 2 Cycle 12 (Reload 11);
. Maximum Average Planar Linear Heat Generation Rate (MAPLHGR)
ARTS MAPLHGR thermal limit multipliers Single Loop Operation (SLO) MAPLHGR multipliers L
e Minimum Critical Power Ratio (MCPR)
ARTS MCPR thermal limit adjustments and multipliers e
Single Loop Operation (SLO) MCPR adjustment Rod Block Monitor (RBM) Analytical Limits, Allowable Values and MCPR Limits e
Linear Heat Generation Rate (LHGR).
e Turbine Bypass Valve Parameters These values have' been determined using NRC-approved methodology and are established such that all applicab!e limits of the plant safety analysis are met.
This report provides the means for calculating the Operating Limit MCPR and MAPLHGR thermal limits for the
. following conditions:
All points in the operating region of the power / flow map including Maximum Extended Load Line Limit
. (MELLL) down to 81% of rated core flow during full power (3458 MWt) operation increased Core Flow (ICF), up to 110% of rated core flow e
i End-of-Cycle Power Coastdown to a minimum power level of 40%
e Feedwater Heaters Out of Service (FWHOOS) to 55' F temperature reduction e
Final Feedwater. Temperature Reduction (FWTR) between End-of-Rated (EOR) and End-of-Cycle (EOC) to 80* F temperature reduction The Allowable Values, documented in Reference 21. for feedwater temperature as a function of thermal power for both FWHOOS and FWTR are specified in the appropriate Peach Bottom procedures.
Note that the term 'l EOR" refers to the cycle exposure.at which operation at " rated conditions" is no longer-!
possible (i.e., the' cycle exposure at which cycle extension begins) based on the EOR point as documented in the' !
. current revision of the Cycle Management Report.
i Preparation of this report was performed in accordance with PECO Energy Fuel and Services Division Procedure '
t FM-300 TReload Core Licensing". This report is submitted in accordance with Technical Specification 5.6.5 of Reference (1) and contains all thermal limit parameters related to the implementation of the ARTS Improvement '
- Program and Maximum Extended Load Line Limit Analyses (ARTS /MELLLA) for Peach Bottom Unit 2 Cycle 12.
PECO Energy Fuel and Services Division -
PECO COLR=P2C12
..} P2C12 Core Operating Limits Report Page 4, Rev.4
. ]AEkHGR LIMITS The bwnding MAPLHGR limits (kW/ft) for each fuel type are provided in Figures 1 through 4. The~ bounding MAPLHGR limits are the lowest kW/ft limits of the fuel lattices (excluding natural uranium) which comprise a given fuel type as a function of' average planar exposure. - The MAPLHGR figures are used when hand calculations are required as specified in Reference (4). All MAPLHGR values for each fuel type as a function of axial location and average planar exposure shall be less than or equal to the applicable MAPLHGR limits for the respective fuel and lattice types to be in compliance with Technical Specification 3.2.1. These MAPLHGR limit 2 are specified in References (2), (3),-(7) and (20) and the process computer databank. No reduction in the.
standard MAPLHGR limits is required under ARTS during_ single loop operation (SLO MAPLHGR multiplier =
1.0). The ARTS-based MAPLHGR power-dependent multipliers (MAPFAC(P)) are provided in Figures 5,6 and g 7J Figure 5 is-valid for.seven or more (of nine) Turbine Bypass Valves (TBVs) In-Service and temperature reduction of 55' F for FWTR operation._ Figure 6 is valid for seven or more (of nine) Turbine Bypass Valves (TBVs) In-Service and temperature reduction of 80' F for FWTR operation. Figure 7 is valid for three or more (of nine) TBVs Out-of-Service (OOS) and FWTR operation of 80* F. The flow-dependent multipliers (MAPFAC(F))
are provided in Figures 8 and 9 as a function of the number of recirculation loops in operation only. The power-and flow-dependent MAPLHGR multipliers were obtained from References (5), (12), (16), (19), (23), and (24).
MCPR LIMITS The Operating Limit MCPR (OLMCPR) for use in Technical Specification 3.2.2 for each fuel type is provided in Table 1. These values are determined by the cycle-specific fuel reload analyses in Reference (2). The OLMCPR is increased by 0.02 when operating in SLO (due to the safety limit increase). The Safety Limit MCPRs are documented in Section 2.1.1.2 of Reference (1).
h Control rod scram time verification is required as per Technical Specification 3.1.4, " Control Rod Scram Times".
l Tau, a measure of scram time performance to notch position 36 throughout the cycle, is determined based on the cumulative scram time' test results. The calculation of Tau shall be performed in accordance with site i procedures. Linear interpolation shall be used to calculate the OLMCPR value if Tau is between 0.0 (Tau Option
.B) and 1.0 (Tau Option A).
Separate MCPR values are presented herein (Table 1) for the following domains:
o Core Flow s 100% of Rated, No FWHOOS/FWTR, TBVs In-Service (seven or more in-service) o Core Flow > 100% of Rated, with or without FWHOOS/FWTR, TBVs In-Service o Core Flow 5100% of Rated, with FWHOOS or FWTR, TBVs in-Service o 'TBVs Out-of-Service (three or more out-of-service) with al! other domains h The OLMCPR values are documented in References (2), (19), and (25) for the GE11 and GE13 fuel designs.
The_ ARTS-based power-dependent MCPR limits, OLMCPR(P), for use in Technical Specification 3.2.2 are
-provided in Figures 10c 11, and 12, Figure 10 is valid for seven or more TBVs in-Service and temperature
' reduction of 55' F for FWTR operation. Figure 11 is valid for seven or more (of nine) TBVs In-Service and temperature. reduction _ of 80' F for FWTR operation. Figure 12 is valid for three or more TBVOOS and temperature reduction *of 80* F for FWTR operation. The flow-dependent MCPR limits, OLMCPR(F), are provided in Figure 13. The OLMCPR(P) values below the turbine scram bypass power are documented in
- Reference (19) and'(24). OLMCPR(P, F) curves were obtained from References (5), (16), (17), (19), (23), and.
j-(24)..
~
,I PECO Energy Fuel and Services Division PECO-COLR P2012
_ l P2C12 Core Operating Umits Report Page 5, Rev.4
'VERALL GOVERNING MCPR AND MAPLHGR LIMITS
,4RTS provides for power-and flow-dependent thermal limit adjustments and multipliers which allow for a more reliable administration of the MCPR and MAPLHGR thermal limits. At any given power / flow (P/F) state, I
all four limits are to be determined: MAPFAC(P), MAPFAC(F), OLMCPR(P), and OLMCPR(F) from Figures 5 l' through 13, inclusive. The most limiting MCPR and the most limiting MAPLHGR [ maximum of O and OLMCPR(F) and minimum of MAPLHGR(P) and MAPLHGR(F)] for a given (P,F) condition will be the governing limits. The OLMCPR for each fuel type is determined by the cycle-specific fuel reload analyses in Reference (2). Rated MAPLHGR values are a composite of results obtained from bundle-specific thermal-mechanical and emergency core cooling system analyses. Supporting documentation for the ARTS-based j limits is provided in References (5), (6), (12), (16), (17), (197, (23), (24) and (25).
. ROD BLOCK MONITOR SETPOINTS I
The RBM power-biased Analytical Limits, Allowable Values and MCPR Limits for use in Technical Specification 3.3.2.1 are provided in Tables 2 and 3 per Reference (5) with supporting documentation in References (2), (8), (14), (15) and (18). Table 2 must be utilized from Beginning-of-Cycle (BOC) to the End-of-Rated (EOR) - 2000 mwd /ST statepoint. Either Table 2 or Table 3 may be used from EOR - 2000 1
mwd /ST to End of-Cycle (EOC).
. LINEAR HEAT GENERATION RATES
-The beginning of life (maximum) LHGR values for each fuel type for use in Technical Specification 3.2.3 are provided in Table 4. Conservative LHGR values as a function of fuel exposure are provided in the process-omputer data bank. LHGR values are documented in References (4) and (13).
STEAM BYPASS SYSTEM OPERABILITY The operability requirements for the steam bypass system are governed by Technical Specification 3.7.6 and are further discussed in Reference (10). If the requirements cannot be met, the appropriate power / flow-l dependent limits for TBVOOS must be used (Table 1 with Figures 7 and 12). The minimum number of bypass valves to maintain system operability is seven as per References (9) and (10) and Table 5. Table 5 also includes other Turbine Bypass Valve parameters.-
l REFERENCES
- 1) " Technical Specifications for Peach Bottom Atomic Power Station Unit 2", Docket No. 50-277, Appendix A to License No. DPR-44,
- 2) " Supplemental Reload Licensing Report for Peach Bottom Atomic Power Station Unit 2, Reload 11, Cycle 12", GE Nuclear Energy Document No. 24A5366, Rev. O, September 1996.
- 3) " Lattice Dependent MAPLHGR Report for Peach Bottom Atomic Power Station Unit 2 Reload 10 Cycle 11",24A5154AA, Revision 0, September,1994.
- 4) " General Electric Standard Application.for. Reactor Fuel", NEDE-24011-P-A-13, August 1996; and I
l.
NEDE-24011-P-A-13 US, August 1996.
- 5) " Maximum Extended Load Line Limit and ARTS Improvement Program Analyses for Peach Bottom l
Atomic Power Station Unit 2 and 3", NEDC-32162P, Revision 2, March 1995.
- 6) " Level 8 Analytical Limit increase Engineering Report for Peach Bottom 2 and 3", NEDC-32231P, August 1993 :
PECO Energy Fuel and Services Division PECO-COLR P2012
- l P2C12 Core Operating Umits Report Page 6, Rev. 4 7)' " Lattice Dependent MAPLHGR Report for Peach Bottom Atomic Power Station Unit 2 Reload 9 Cycle 10",23A7188AA, Revision 0, September,1992.
- 8) ' Letter, G. V. Kumar to H. J. Ryan, " Justification for Reduction of Rod Block Monitor Systsm Downscale Trip Setpoint For Peach Bottom Atomic Power Station", May 23,1994.
9)," Letter from R. M.~ Butrovich to H. J. Diamond, " Peach Bottom-2 Cycle 12 Turbine Bypass Valve
- Capacity _ Variation from Design Basis", January 9,1995.
- 10) Letter from G. V. Kumar to G. C. Storey, "PBAPS Evaluation of Turbine Bypass Surveillance Requirements", January 19,1995,
- 12) Letter from G. V. Kumar to-G.'C. Storey, " Updated Peach Bottom ARTS Generic Limits / improved i
Technical Specification Validation", December 18,1995.
- 13) PECO Energy Company Design Record File (DRF) Number 2212.
I
- 15) Letter from M. G. Wiwel to A. S. Hegedus and R. C. Stott, " Rod Block Monitor Downscale Settings for ITS", March 14,1995.
- 16) Letter from Dan Waltermire to Jim Tusar, " Peach Bottom 2 Cycle 12 ARTS Data", September 12,1996.
- 17) Letter from R.' M. Butrovich to J. M. Carmody, " Peach Bottom 2 Cycle 12 Generic ARTS Data", August I
22,1996.
.10,1997.
- 19) " Peach Bottom Atomic Power Station Unit 2 Cycle 12 ARTS Thermal Limits Analyses", NEDC-
' 32706P, Revision 0, April 1997.
- 20) flattice Dependent MAPLHGR Report for Peach Bottom Atomic Power Station Unit 2, Reload 11, i
Cycle 12",24A5366AA, Rev. O, September 1996.
- 21) La tter, Jose L. Casillas to M. May, "PBAPS FFWTR - Core Power vs. FW Temperature Characteristics",
June 4,1997.
- 22) -10CFR50.59 Review for End of Cycle Operation with FFWTR of 80' F, Peach Bottom Atomic Power Station Units 2 & 3, Revision 0.
l
- 23) Letter, Jose L. Casillas to A. Olson. " Peach Bottom 2 Cycle 12 Evaluation of Fuel Thermal Limits at 60% and 30% Core Power for High Water Level Time Delay of 0.7 Seconds", December 16,1997.
- 24) Letter, Jose L. Casillas to A. Olson,"PB 2 Cycle 12 Evaluation of Generic Fuel Thermal Limits for less than 30% Core Power for High Water Level Time Delay of 0.7 Seconds", December 2,1997.
- 25)
- Peach Bottom Atomic Power Station Evaluation for Extended Final Feedwater Temperature Reduction", NEDC-32707P, Rev. 0, May 1997.
l PECO Energy Fuel and Services Division PECO-COLR.P2C12 l P2C12 Core Operaung Limits Report Page 7, Rev.4 FIGURE 1 MAXIMUM AVERAGE PLANAR LINEAR HEAT GENERATION RATE (MAPLHGR) VERSUS AVERAGE PLANAR EXPOSURE FUEL TYPE P9 HUB 334-10GZ1 (GE11) 14.00 THIS FIGURE IS REFERRED TO BY 12.00 TECHNICAL SPECIFICATION 3.2.1 10.00 e
mi 8 00 j
cc 6.00 A
l l
4.00 1
'2.00 0.00 0.0 10.0 20.0 30.0 40.0 50.0 60.0 Average Planar Exposure, GWd/ST Avg Plan Avg Plan Avg Plan Exposure MAPLHGR Exposure MAPLHGR Exposure MAPLHGR (GWd/ST)
(kW/ft)
(GWd/ST)
(kW/ft)
(GWd/ST)
(kW/ft) 0.0 10.63 7.0 11.70 25.0 11.02 0.2 10.68 8.0 11.81 30.0 10.49 1.0 10.82 9.0 11.93 35.0 9.90 f
2.0 11.01 10.0 12.07 40.0 9.31 3.0 11.20 12.5 12.13 45.0 8.61 4.0 11.37 15.0 11.97 50.0 7.85 5.0 11.48 17.5 11.74 55.0 6.93 6.0 11.59 20.0 11.50 58.2 6.36
PECO Energy Fuel and Services Division PECO COLR P2C12 l P2C12 Core Operating Limits Report Page 8, Rev. 4 i
FIGURE 2 l
i MAXIMUM AVERAGE PLANAR LINEAR HEAT GENERATION RATE (MAPLHGR) VERSUS AVERAGE PLANAR EXPOSURE l
FUEL TYPE P9 HUB 387-12GZ3 (GE11)
I 14.00 THIS FIGURE IS REFERRED TO BY 12.00 TECHNICAL SPECIFICATION 3.2.1 l
10.00 E
g 8.00 b
8 6.00 4.00 2.00 0.00 0.0 10.0 20.0 30.0 40.0 50.0 60.0 Average Planar Exposure, GWd/ST Avg Plan Avg Plan Avg Plan Exposure MAPLHGR Exposure MAPLHGR Exposure MAPLHGR (GWd/ST)
(kW/ftj (GWd/ST)
(kW/ft)
(GWd/ST)
(kW/ft) 0.0 11.13 7.0 12.15 25.0 11.01 0.2 11.18 8.0 12.30 30.0 10.29 1.0 11.28 9.0 12.44 35.0 9.59 2.0 11.42 10.0 12.58 40.0 8.90 3.0 11.56 12.5 12.66 45.0 8.22 4.0 11.70 15.0 12.42 50.0 7.54
- 5.0 11.86 17.5 12.10 55.0 6.85 6.0 12.01 20.0 11.74 57.89 6.45
PECO Energy Fuel and Services Division PECO COLR P2C12 l P2C12 Core Operating Limits Report Page 9, Rev.4 I FIGURE 3 MAXIMUM AVERAGE PLANAR LINEAR HEAT GENERATION RATE (MAPLHGR) VERSUS l
AVERAGE PLANAR EXPOSURE FUEL TYPE P9DTB39713GZ (GE13) l 14.00 I
THIS FIGURE IS REFERRED TO BY j
12.00 TECHNICAL SPECIFICATION 3.2.1 10.00 l
I l
4 8.00 l.
b 12:
6.00 a
4.00 t
2.00 l
0.00 0.0 10 0 20.0 30.0 40.0 50.0 60.0 Average Planar Exposure, GWd/ST Avg P:an Avg Plan Avg Plan Exposure MAPLHGR Exposure
@Vd/ST)
(kW/ft)
(GWd/ST)
(kWlft)
(GWd/ST)
(kW/ft) 0.0 10.89 7.0 12.10 25.0 11.17 0.2 10.91 8.0 12.23 30.0 10.44 1.0 10.99 9.0 12.37 35.0 9.73 I'
2.0 11.12 10.0 12.52 40.0 9.03 3.0
-11.29 12.5 12.61 45.0 8.34 4.0 11.47 15.0 12.51 50.0 7.65 l-5.0 11.67 17.5 12.24 55.0 6.95 6.0 11.89 20.0 11.90 58.22 6.49 i
PECO Energy Fuel and Services Division PECO-COLR-P2C12 l
l P2C12 Core Operating Umits Report i
Page 10, Rev. 4 FIGURE 4 MAXIMUM AVERAGE PLANAR LINEAR HEAT GENERATION RATE (MAPLHGR) VERSUS AVERAGE PLANAR EXPOSURE FUEL TYPE P9DTB392-15GZ (GE13) l 14.00 l
l THIS FIGURE IS REFERRED TO BY 12.00 TECHNICAL SPECIFICATION 3.2.1 10.00 t-d' 8.00 8
l 5
l 5 S 00 3
4.00 I
I 2.00 l
0.00 0.0 10.0 20.0 30.0 40 0 50.0 60.0 Average Planar Exposure, GWd/ST l
l Avg Plan Avg Plan Avg Plan Exposure MAPLHGR Exposure MAPLHGR Exposure MAPLHGR (GWd/ST)
(kWlft)
(GWd/ST)
(kW/ft)
(GWd/ST)
(kW/f_t1 0.0 10.64 7.0 11.69 25.0 11.06 i
l 0.2 10.69 8.0 11.86 30.0 10.34 l
1.0 10.80 9.0 12.03 35.0 9.64 2.0 10.93 10.0 12.21 40.0 8.94 3.0 11.07 12.5 12.33 45.0 8.26 l
4.0 11.22 15.0 12.33 50.0 7.57 l
5.0 11.37 17.5 12.11 55.0 6.88 6.0 11.53 20.0 11.78 57.88 6.48 l
i l.
\\
PECO Energy Fuel and Services Division PECO-COLR P2C12 l P2C12 Core Operating Limits Report Page 11, Rev,4 I
FIGURE 5 POWER-DEPENDENT MAPLHGR MULTIPLIER, MAPFAC(P)
)
THIS FIGURE IS REFERRED TO BY TECHNICAL SPECIFICATION 3.2.1
(
1 1
l VALID FOR 7 OR MORE TBVs IN-SERVICE AND MAX 55 F FWTR 0
i 1.0 0.946 1
0.9 --
l
\\
0.8 - -
0.787 l
{
0,7 - -
l l
l l
l O.s -
l s 60% Flow l
l l
l 0.511 0,,
0.5 O
l g
0.451, l.
'O.418 0.4 -
0.388 l
l l
- M APLHGRsta 0,3 -.
> 60% Flow l
MAPLHGRstd = Standard MAPLHGR Limits l
l l
l For 25% > P -
No Thermal Limits Monitoring Required No Limits Specified 0.2 --
{
{
For 25% s P< 30% ~ M APFAC(P) = 0 511 + 0.012(P - 30%)
l l
l For s 60% Cere Flow l
l l
M APFAC(P) = 0.418 + 0.006(P - 30%)
{
{
For > 60% Core Flow 0.1 --
l l
l l
For 30% s P < 60%: M APFAC(P) = 0.787+ 0.0053(P 30%)
{
l For 60% s P < 95%: M APFAC(P) = 0 946+0.00154(P - 60%)
l For 95% s P:
M APF AC(P) = 1.0 0.0 O
10 20 30 40 50 60 70 80 90 100 l
Power (% Rated) i
.__._.________.__m
E.
I PECO Energy Fuel and Services Division PECO-COLR P2C12 l
l P2C12 Core Operating Limits Report Page 12, Rev. 4 i
I i
FIGURE 6 POWER-DEPENDENT MAPLHGR MULTIPLIER, MAPFAC(P) l THIS FIGURE IS REFERRED TO BY TECHNICAL SPECIFICATION 3.2.1
+
VALID FOR 7 OR MORE TBVs IN SERVICE AND MAX 800 F FWTR I
l 1.0
~
0.964 0.9 --
0.8 --
1 i
l 0.7 - -
0.670 l
1 l
0.6 --
l s 60% Flow
{
l E
f_L 0.511 0.5 -
l
- n. -
3 0.451.
l
/l 0.418 l
l 0.4 - -
f 0.388; l
l l
i l
l MAPLHGRstd = Standard MAPLHGR Limits l
{
0.3 --
> 60% Flow
{
l l
l l
For 25% > P :
No Thermal Limits Monitoring Required j
{
No Limits Specified
{
For 25% s P< 30% - M APFAC(P) = 0.511 + 0.012(P - 30%)
0.2 l
i l
l For s 60% Core Flow
{
{
M APFAC(P) = 0.418 + 0.006(P - 30%)
l l
For > 60% Core Flow l
l 0.1 --
l l
For 30% s P < 75%: M APFAC(P) = 0.670+0.00653(P 30%)
{
{
For 75% s P < 95%: M APFAC(P) = 0.964+0.00180(P 75%)
j M APFAC(P) = 1.0 l
l For 95% < P:
0.0 0
10 20 30 40 50 60 70 80 90 100 Power (% Rated)
PECO Energy Fuel and Services Division PECO COLR P2C12 l P2C12 Core Operating Limits Report Page 13. Rev. 4 FIGURE 7 POWER DEPENDENT MAPLHGR MULTIPLIER, MAPFAC(P)
THIS FIGURE IS REFERRED TO BY TECHNICAL SPECIFICATION 3.2.1 AND 3.7.6 l ~
VALID FOR 3 OR MORE TBVs OOS AND MAX 80 F FWTR 0
1.0 i
0.926 I'
O.9..
I 0.866 i
0.8..
f 0.721 0.7..
0.6..
5 60% Flow E
5 0*5 0.53 0.451, j
- 0.418 0.38 M AFLHGH(F) a M AFF AG(F) ' MAFLHUHstd 0.3..
> 60% Flow MAPLHGRstd = Standard MAPLHGR Limits j
j For 25% > P :
No Thermal Limits Monitoring Required No Limits Specified 0.2 --
For 25% 5 P< 30%
M APFAC(P) = 0.511 + 0.012(P - 30%)
{
{
For s 60% Core Flow M APFAC(P) = 0.418 + 0.006(P - 30%)
For > 60% Core Flow O.1..
For 30% s P < 60%: MAPFAC(P) = 0.721+ 0.00483(P - 30%)
For 60% s P < 90%: M APFAC(P) = 0.866+0.002(P - 60%)
For 90% 5 P:
M APFAC(P) = 0.926+0.0074(P - 90%)
0.0 O
10 20 30 40 50 60 70 80 90 100 Power (% Rated)
l 1
PECO Energy Fuel and Services D?fision PECO-COLR P2012 P2C12 Core Operating Limits Report Page 14, Rev. 4 FIGURE 8 FLOW-DEPENDENT MAPLHGR MULTIPLIER, MAPFAC(F)
THIS FIGURE IS itEFERRED TO BY TECHNICAL SPECIFICATION 3.2.1 VAllD FOR 2 LOOP REClRC FLOW
~
l 1.0 l
0.9 l
(
1 0.8
)
0.7 l
l 0.6 6
ma 0.5 l
E MAPLHGR(F) = MAPFAC(F)
- MAPLHGR(std) 0.4 l
MAPLHGR(std) = Standard MAPLHGR Limits l
MAPFAC(F) = MIN (1.0, Af*We/100 + Bf);
0.3
- where, We = % Rated Core Flow Af = 0.6682, Bf = 0.5055 l
l 0.2 l
l' O.1 1
1 0.0 10 20 30 40 50 60 70 80 90 100 110 CORE FLOW (% RATED) i l
L
1 l.*
PECO Energy Fuel and Services Divisi:n PECO COLR-P2C12 l
l P2C12 Core Operating Umits Report Page 15, Rev. 4 FIGURE 9 FLOW-DEPENDENT MAPLHGR MULTIPLIER, MAPFAC(F)
THIS FIGURE IS REFERRED TO BY TECHNICAL SPECIFICATION 3.2.1 AND 3.4.1 VALID FOR SINGLE LOOP RECIRC FLOW 1.0 0.9 0.8 0.7 0.6 4 0.5 g
MAPLHGR(F) = MAPFAC(F)
- MAPLHGR(std)
E MAPLHGR(std) = Standard MAPLHGR Limits 0.4 MAPFAC(F) = MIN (0.9, Af*Wc/100 + Bf);
- where, 0.3 We = % Rated Core Flow I
Af = 0.6682. Bf = 0.5055 0.2 0.1 f_
' O.0 l
10 20 30 40 50 60 70 80 90 100
'110 l
CORE FLOW (% RATED) l l
l
PECO Energy Fuel and Services Division PECO COLR P2C12
} P2012 Core Operating Unists Repon Page 16, Rev. 4 TABLE 1 OPERATING LIMIT MINIMUM CRITICAL POWER RATIO (OLMCPR)
I 1
l Use in conjunction with Figures 10,11,12 and 13 Add 0.02 to the OLMCPR whenin Single Loop Operation l
These Tables are referred to by Technical Specification 3.2.2,3.4.1 and 3.7.6 CORE FLOW s 100%
CORE FLOW > 100%
NO FWHOOS/FWTR YES OR NO 4
_ _ _T_B,,Vs,1,,N_-S ER,VIC_E,_ _,
Fuel Type Exposure Opt. B Opt. A Opt. 8 Opt. A GE11 BOC 1.31 1.35 1.31 1.36 and MOC 1.30 1.35 1.31 1.36 GE13 EOC 1.37 1.45 1.38 1.46 CORE FLOW s 100%
TBVOOS FWHOOS/FWTR WITH TBVs IN SERVICE ALL OTHER DOMAINS Fuel Type Exposure Opt. B Opt. A Opt. B Opt. A GE11 BOC 1.31 1.36 1.38 1.43 and MOC 1.31 1.36 1.38 1.43 GE13 EOC 1.37 1.45 1.44 1.52 NOTES:
- 1) Opt. B: Tau =0.0
- 2) Opt. A: Tau =1.0
- 3) When Tau does not equal 0.0 or 1.0, use linear interpolation
- 4) BOC: Cycle exposure range from BOC to 1,000 mwd /ST
- 5) MOC: Cycle exposure range from 1,000 mwd /ST to EOR 2000 mwd /ST
- 6) EOC: Cycle exposure range from EOR 2000 mwd /ST to EOC
- 7) FWHOOS: Feedwater Heaters Out-of-Service (Maximum 55' F).
- 8) FWTR: Final Feedwater Temperature Reduction (Maximum 80' F).
l'
- 9) TBVOOS: Turbine Bypass Valves Out-of-Service (3 or more TBVOOS) l t
PECO Energy Fuel and Services Division PECO<COLR.P2012 l P2C12 Core Operating Limits Report Page 17, Rev.4 l
FIGURE 10 l
l POWER DEPENDENT MCPR LIMIT, OLMCPR(P)
THIS FIGURE IS REFERRED TO BY TECHNICAL SPECIFICATION 3.2.2 l
VALID FOR 7 OR MORE TBVs IN-SERVICE AND MAX SS F FWTR l
3.25 3.2 l
UPEIRITTRUTIMITMCPMP)TCp7PTRXTING UMITUCPMi00F j,
3.0
/
f FOR P425% :NO THERMAL LIMIT MONITORINO REQUIREO I
' > 60% Flow NO LIMITS SPECIFIED 2.91 FOR 25% < P < 30%: OLMCPR e K8YP + SLOPE (30%.Pl l
l KBYP = 2.26 FOR 5 60% CORE FLOW 2.3 l
= 2.91 FOR
- 60% CORE FLOW 2.78 stops e 0.104 FOR s 60% CORE FLOW e 0 066 FOR
- 60% CORE FLOW FOR 30% 5 & < 65% :
Kp = 1.13 + 0 00433(65%. P) 2.6
- y FOR 65% 5 P < 65% :
Kp = 1.056 + 0.0004(85% P) n g"
,/
l FOR 85% 5 P Kp = 100 + 0.00207(100%. P)
/
l 2.4
< 60% Flow '
l 2.26 l
2.2
{
j l
l l
l ABSOLUTE l
2.0 l
M U LTIP LIE R g
E 1.8 o
E" 1.6 l
w 3
a I
1.4 3
3 g
{
l1.282 1.130 i
]
l l
q 1.056 g
1.0 rm* ck-i f
0 10 20 30 40 50 60 70 80 90 100 Power (% Rated)
l PECO Energy Fuel and Services Division PECO COLR-P2C12 l P2C12 Core Operating Limits Report Page 18, Rev.4 l
l FIGURE 11 I
POWER DEPENDENT MCPR LIMIT, OLMCPR(P) i i
THIS FIGURE IS REFERRED TO BY TECHNICAL SPECIFICATION 3.2.2 l-VALID FOR 7 OR MORE TBVs IN-SERVICE AND MAX 800 F FWTR i
I l
l 3.25
~
3.2 3.249 l
l l
l 3.0
~OPER ATIMG~DMITMCPRlpiWF'DPER ATING DMITMCPRTTUDD 29I FOR P=25% :NO THERM AL LIMIT MONITORING REOUIRED
> 60% Flow i
l NO LIMITS SPECIFIED 2.8 2.78 FOR 25% 1P < 30%: OLMCPR = KBYP + SLOPE (30% - P) l KBYP = 2.26 FOR s 60% CORE FLOW l
= 2.91 FOR > 60% CORE FLOW l
SLOPE = o 104 FOR s 60% CORE FLOW l
2.6
{
{
O 'O " * '0" C O " E 0
- i E
l FOR 30% $ P < 65% :
Kp = 1.13 + 0.00329(6s%. P)
E i
i
/:
L l
FOR es% < P < es% :
K, = 1056 + 0 002(ass. P)
,/ ff 2.4 FOR ass s P : xp = 1.00 + o 0022(100% - P) i O
/
l l
l 160% Flow l
l l
2.26 2.2
{
{
l l
l ABSOLUTE 2.0 S
MULTIPLIER l
n a.
l l
1.8 7t l
l E.
l l
l w
l
.2 5
1.6 l
1 l
l 3
l l
0:
g, O
1.4 3
{
l 1.315 x
l 0:
l l
1.2 l
l 1130
{
j 1.096 1.056 l
5 1.0 1.0 O
10-20 30 40 50 60 70
'O 90 100 J
t l
. Power (% Rated)
PECO Energy Fueland Services DMslon PECO-COLR P2C12 l P2C12 Core Operating Umits Report s
Page 19, Rev. 4 FIGURE 12 POWE.".-JEPENDENT MCPR LIMITS, OLMCPR(P)
THIS FIGURE IS REFERRED TO BY TECHNICAL SPECIFICATION 3.2.2 AND 3.7.6 l ~
VAllD FOR 3 OR MORE TBVs OUT OF-SERVICE AND MAX 80 F FWTR 3.25 3.2 3.249 3.0 l
l O P E R ATING ITRITMCP RTPTi Kii'TPTRXTWGTlWTVCP RUUOT-
'/
2.91 FOR P<25% : NO THERM AL LIMIT MONITORING REOUIRED
> 60% Flow
{
{
NO LIMITS SPECIFIED 2.8 2.78 FOR 25% 1 P e 30%; OLMCPR = K8YP + SLOPE (30%. P) i K8YP = 2.26 FOR 5 60% CORE FLOW
= 2.91 FOR
- 60% CORE FLOW SLOPE = 0.104 FOR s 60% CORE FLOW 2.6
{
{
= 0. 68 FOR
- 6 % CORE HOW b
{
FOR 30% 5 P 4 65% :
K p = 1.13 + 0 0052W? S%. P)
~E O-l FOR 65% 5 P < 85% :
Kp = 1.056 + 0 002(85%. P) 2.4 O
/. {
{
FOR 85% 5 P : Kp = 1.00 + 0 0032(100%. P) l l
< 60% Flow
~
2.26 2.2 l
l l
l l
l ABSOLUTE at 2.0 M UL TIPLIER n
a.
g 1
18 n.
E.
g
=
1*8 a
E E
o, k
1'4 7
{
1.315 ti m
1.2 1.130
{
1.096 1.056 1.04o 1.0 0
10 20 30 40 50 60 70 80 90 100 Power (% Rated)
PECO Enesgy Fuoiand SeMees DMslon PECO-COLR P2C13 l P2C12 Core Operatang Umits Report Page 20, Rev. 4 FIGURE 13 FLOW-DEPENDENT MCPR LIMITS, OLMCPR(F)
THIS FIGURE IS REFERRED TO BY TECHNICAL SPECIFICATION 3.2.2 AND 3.4.1 3
1.90 For We (% Rated Core Flow) 2 40%
OLMCPR(F) = Max (1.25, Af*Wc/100 + Bf) 1.80 For We (% Rated Core Flow) < 40%
OLMCPR(F) = (Af
- We /100 + Bf)*(1 + 0.0032*(40-Wc))
Af = -0.5526*(1.11/1.07) 1.70 Bf = 1.6311 *(1.11/1.07) 1.80
~
SL.
EI 1.50 50 1.40 1.30
\\
1.20 l
1 1.10 l
10 23 30 40 50 60 70 80 90 100 110 Core Flow (% Rated)
PECO Energy Fuel and Services Division PECO COLR P2C12 l P2C12 Core Operating Umits Report Page 21, Rev. 4 TABLE 2 ROD BLOCK MONITOR ANALYTICAL LIMITS, ALLOWABLE VALUES, AND MCPR LIMITS THIS TABLE IS REFERRED TO BY TECHNICAL SPECIFICATION 3.3.2.1 Applicability:
Required ior BOC to EOR - 2000 mwd /ST Optional for EOR - 2000 mwd /ST to EOC ANALYTICAL ALLOWABLE M C Phi ~
FUNCTION LIMIT (1)
VALUE(1)
LIMIT Low Power Range - Upscale s 120.0 %
s 118.4 %
< 1.70 (*
Intermediate Power Range - Upscale s 115.2 %
s 113.6 %
< 1.70 (5 High Power Range - Upscale s 110.2 %
s 108.6 %
< 1.70 (4
< 1.40 ( )
Inop N/A N/A
< 1.70 (5
< 1.40 (')
Downscale 2 1.0%
2 2.5%
< 1.70 (0
< 1.40 ( )
Bypass Time Delay )
d (1)
These Trip Level Settings (with RBM filter) are based on a rated RWE MCPR limit of 1.30 and cre consistent with an RBM filter time constant between 0.1 and 0.55 seconds.
(2)
This is the MCPR limit (given THERMAL POWER 2 28.3% and < 90% RTP) below which the RBM is required to be OPERABLE (see COLR references 2 and 5 and TS Table 3.3.2.1-1).
(3)
This is the MCPR limit (given THERMAL POWER 2 90% RTP) below which the RBM is required to be OPERABLE (see COLR references 2 and 5 and TS Table 3.3.2.1-1).
(4)
This time delay option is currently not in use at Peach Bottom Unit 2 (see COLR reference 5).
PECO Energy Fuel and Services Divisi:n PECO-COLR P2C12 i P2C12 Core Operating Limits Report Page 22, Rev.4 TABLE 3 ROD BLOCK MONITOR ANALYTICAL LIMITS, ALLO'#ABLE VALUES, AND MCPR LIMITS THIS TABLE IS REFERRED TO BY TECHNICAL SPECIFICATION 3.3.2.1 Applicability:
Not Applicable for BOC to EOR - 2000 mwd /ST Optional for EOR - 2000 mwd /ST to EOC ANALYTICAL ALLOWABLE MCPR FUNCTION LIMITm VALUEW LIMIT Low Power Range - Upscale s 123.0 %
s;121.4 %
< 1.70 (2)
Intermediate Pnwer Range - Upscale s 118.0 %
s 116.4 %
< 1.70 m High Power Range - Upscale s 113.2 %
s 111.6 %
< 1.70 m
< 1.40 m Inop N/A N/A
< 1.70 m
< 1.40 m Downscale 2 1.0%
2 2.5%
< 1.70 m
< 1.40 W Bypass Time DelayW (1)
These Trip Level Settings (with RBM filter) are based on a rated RWE MCPR limit of 1.35 and are consistent wi.1 an RBM filter time constant between 0.1 and 0.55 seconds.
(2)
This is the MCPR limit (given THERMAL POWER 2 28.3% and < 90% RTP) below which the RBM is required to be OPERABLE (see COLR references 2 and 5 and TS Table 3.3.2.1-1).
(3)
This is the MCPR limit (given THERMAL POWER 2 90% RTP) below which the RCM is required to be OPERABLE (see COLR references 2 and 5 and TS Table 3.3.2.1-1).
(4)
This time delay option is currently not in use at Peach Bottom Unit 2 (see COLR reference 5).
PECO Energy Fuel and Services Division PECO-COLR P2C12 l P2C12 Core Operating Limits Report Page 23, Rev 4 i
I 4
TABLE 4 DESIGN LINEAR HEAT GENERATION RATE (LHGR) LIMITS' 1
l FUEL TYPE LHGR LIMIT GE11 14.4 kW/ft l
GE13 14.4 kWift l
1 l
l 1 The LHGR limits provided above are the beginning of life (maximum) values. Conservative LHGR limits as a function of fuel exposure are provided in the process computer data bank.
l
_-__ _ -- J
e PECO EnergyFueland Services DMalon PECO COLR P2C12 l P2013 Core Operating Umits Report Page 24, Rev.4 TABLE 5 TURBINE BYPASS VALVE PARAMETERS TURBINE BYPASS SYSTEM RESPONSE TIMES Maximum delay time before start of bypass valve opening following ganeratlN of the turbine bypass valve flow 0.10 sec signal Maximum time after generation of a turbine bypass valve flow signal for bypass valve position to reach 80% of full 0.30 sec.
flow (includes the above delay time)
Minimum required number of bypass valves to maintain system operability 7
l m:Widbkoir42c12 reve. doc