_ _ _. _ _ -

b,r b,3 m

t o a:

Io,,

UNITED STATES y

g NUCLEAR REGULATORY COMMISSION 3

E WASH!NGTON, D. C. 20555

%5 CERTIFICATE OF REGISTRATION AND SAFETY ANALYSIS

SUMMARY

SEALED SOURCE Amended in Entirety 80-66 Manufacturer and Distributor Sealed Source Model Designation Minnesota Mining and 3E40 Manufacturing Company 3M Center St. Paul, Minnesota 55101 Isotope Maximum Activity Kr-85 1500 Millicuries Conditions of Normal Use The Model 3E40 is designed for industrial beta gauging applications for temperature range of 32-158'F (0 to 70'C) and atmospheric pressure.

Sealed Source Description The source consists of a titanium bar with a 0.187" slot milled 0.200" deep. The slot is covered with a 0.002" thick titanium window sealed by "GAPASIL 9" brazing. The source is filled through a 1/16" copper tube silver brazed after filling. The active dimensions of the source are l

1.125" by 0.187".

The overall dimensions are 3.370" long, 0.38" wide and 0.300" deep. Each flange has a #24 (0.152") hole, the holes are 3.00" apart center-to-center.

Prototype Testing This sealed source is designed to comply with requirements of American l

National Standards Institute ANSI N5.10-1968 classification 32231.

i l

9805280266 960126 PDR RC SSD PDR

Ik p

V 1

v

.'80-66 External' Radiation Levels The external radiation levels from the. source are as follows:

Dose. Rates From 3M 3E40 (1.0 C1)

Dose At Position 5 CM 30 CM

.4 Normal to window ( S )

1100 r/hr*

40 r/hr

. Normal to long side ( / )

140 mr/hr 25 mr/hr Normal to back side ( y )

100 mr/hr 20 mr /hr1

=e Labeling The source.-1s. labeled with: Manufacturer's name, isotope,. quantity, model and serial numbers, and date.-

Quality' Assurance and Control

.The source manufacturer maintains an acceptable quality control program for design, procurement, process,.ind final acceptance of the sealed source.

Limitations and/or Other Conditions of Use.

The source shall be distributed only to specific. licenses of NRC or an Agreement State.

Handling, Storage, Use, Transfer, and Disposal: To be determined by licensing authority.

The Model 3E40 shall not be. subjected to environmental or other conditions of use which exceed ANSI N5.10-1968 Classification 32231.

. References This safety review and registration of Model.3E40 sealed source design is based on information provided by 3M Company letter dated May 16, 1967. ' Amendment No. 1 is based on information contained in 3M Company letters dated September 3,1980 and September 17, 1980.

/[

A Date_ Sctober 7,1980 Reviewed By October 7,:1980 bt.

Y Date Concurre e as4

/// wg4 Cf,t(Ct

  • Estimated

~