ML20247Q303

From kanterella
Jump to navigation Jump to search
Registry of Radioactive Sealed Sources & Devices,Safety Evaluation of Sealed Source for Model 3E40. Certificate:NR-460-S-164-S
ML20247Q303
Person / Time
Site:
(NR-460-S-164-S, NR-460-S-900-S, SSD-91-71)
Issue date: 10/07/1980
From: Singer B, Wright E
NRC
To:
Shared Package
ML20247Q287 List:
References
SSD, NUDOCS 9805280243
Download: ML20247Q303 (3)


Text

_ _ _ _ - _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ - - _ - _ _ - _ _ _ _.

o o

REGISTRY OF RADI0 ACTIVE SEALED SOURCES At!D DEVICES SAFETY EVALUATION OF SEALED SOURCE i

t40. :

NR4605164S DATE:

October 07, 1980 PAGE 1 0F 3 SEALED SOURCE TYPE:

Beta Source I

i MODEL: 3E40 s

f4At:UFACTURE9/ DISTRIBUTOR:

tiinnesota Mining and Manufacturing 3M Center St. Paul, MN 55101 I

(4 MANUFACTURER / DISTRIBUTOR:

ISOTOPE: Krypton-85 MAXIMUM ACTIVITY: 1500 tail 11 curies

(.

1 LEAK TEST FRE00ENCY:

P_RINCIPAL USE:

Beta Gauges R

J CUSTOM SOURCE:

YES-X NO O

t V

9805280243 960126 PDR RC PDR SSD i

p O

REGISTRY OF RADI0 ACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF SEALED SOURCE

&: MR460S1645 DATE:

October 07, 1980 PAGE 2 0F 3 SEALED SOURCE TYPE:

Beta Source DESCRIPTION:

i The source consists of a titanium bar with a 0.187" slot millec 0.200" deep.

The slot is covered with a 0.002" thick titanium window sealed by "GAPASIL 9" brazing.

The source is filled through a 1/16" copper tube silver brazed afte.r filling.

The active dimensions of the source are 1.125" by 0.187".

The overall dimensions are 3.370" long, 0.38" wice and 0.300" deep.

Each flange has a =24 (0.152") hole, the holes are 3.00" apart center-to-center.

LABELING:

The source is labeled with: Manufacturer's name, isotope, quantity, model and serial numbers, and date.

f CONDITIONS OF NORMAL USE:

The Model 3E40 is designed for industrial beta gauging applications for temperature range of 32-158'F (0 to 70*C) and atmospheric pressure.

PROTOTYPE TESTING:

This sealed source is designed to comply with requirements of American National Standards Institute ANSI N5.10-1968 classification 32231.

EXTERNAL RADIATION LEVELS:

The external radiation levels from the-source are as follows:

Dose Rates From 3M 3E40 (1.9 Ci)

Dose At Position 5 CM 30 CM Nonnal to window -(beta) 1100 R/hr*

40 R/hr Normal to long side (garmna) 140 mr/hr 25 mr/hr Normal to back side (gamma) 100 mr/hr 20 mr/hr

  • Estimated

P Q

REGISTRY OF RADI0 ACTIVE SEALED SOURCES AhD DEVICES SAFETY EVALUATION OF SEALED SOURCE 1

NO.: NR460516,45 DATE:

October 07, 1980 PAGE 3 0F 3 SEALED SOURCE TYPE:

Bsta Source QUALITY ASSURANCE AND CONTROL:

The source manufacturer maintains an acceptable quality control program for design, procurerant, process, and final acceptance o# the sealed source.

LIMITATIONS AND/0R OTHER CONSIDERATIONS OF USE:

The source shall be distributed only to specific licensees of NRC or an Agreement State.

l'andling, Storage, Use, Transfer, and Disposal:

To be determined by licensing authority.

The Model 3E40 shall not be rubjecteo to environmental or other conditions of

'c use which exceed ANSI N5.10-1968 classification 32231.

REFERENCES:

This safety review and regi'stration of Model 3'd40 sealed source design is based on information provided by 3M Company letter dated May TS,1967. Amendment No. 1 is based on information containao in 3M Ccmoany letters dated September 3,1980 and September 17, 1980.

Date October 7, 1980 Reviewed By

/s/

Earl G. Wrignt Date October 7, 1980 Concurrence

/s/

Bernard 5inger

_ _ _ _ _