ys May-26,1989 s
~
Docket Nos.~'50-295 and 50-304 Mr. Thomas' J. Kovach 7,
- Nuclear Licensing Manager Conrnonwealth Edison Company
' Post Office Box 767-
- Chicago, Illinois 60690
SUBJECT:
REACTOR COOLANT PUMP TRIP FOR ZION UNIT NOS. liAND 2 (TACNOS.49683AND~49684)-
Dear Mr. Kovach:
-For the/ reactor coolant pump (RCP) trip issue defined in TMI' Action Plan Item
-II.K.3.5 (Multiplant Action G-01), the staff generically' approved the Westinghouse Owners Group (WOG) methodology in Generic Letter 85-12 with the condition that plant-specific information needs to be addressed. Our review of the Zion plant-specifi.c information has progressed.to a degree.that we can
' conclude that the WOG methodology has significantly improved the reactor safety, and there are no major safety-significant concerns for the plant-specific
.information.
Accordingly, we have completed our review of your plant-specific RCP. trip setpoint development and find it acceptable. This issue may be the subject of on-site.. verification.
Sincerely, t
Chandu P. Patel, Project Manager 7
9906060171 890526
?
Project Directorate III-2 DR ADOCK 0500 95 Division of Reactor Projects III, IV, V, and Special Projects
-cc: 'See next page l
DISTRIBUTION L'
^Dockettfile d
.NRC &. Local PDRs PDIII-2 r/f DMuller MVirgilio LLuther CPatel 0GC l
EJordan BGrimes ACRS(10)'
off Ofol PDIII-2:
PDIII-2 4 P
- CPatel:km LLuther D
1 i i
-5/A%/89 5/3 / /89 5/%/89-i w
> ~
.p u:
(
UNITED STATES -
.[,
- g NUCLEAR REGULATORY COMMISSION j
WASHINGTON, D. C. 20555 O
%,*..+;[
May 26,1989 l
Docket Nos. 50-295 and 50-304 Mr. Thomas J. Kovach Nuclear Licensing Manager Commonwealth Edison Comprny Post Office Box 767 Chicago, Illinois 60690
SUBJECT:
REACTOR COOLANT PUMP TRIP FOR ZION UNIT NOS. 1 AND 2 (TAC NOS. 49683 AND 49684)
Dear Mr. Kovach:
For the reactor coolant pump (RCP) trip issue defined in TMI Action Plan Item II.K.3.5 (Multiplant-Action G-01), the staff generically approved the Westinghouse.0wners' Group (WOG) methodology in Generic Letter 85-12 with the condition that plant-specific information needs to be addressed. Our review of the Zion plant-specific information has progressed to a degree that we can conclude that the WOG methodology has significantly improved the reactor safety, and there are no major safety-significant concerns for the plant-specific l
information.
Accordingly, we have completed our review of your plant-specific RCP trip setpoint development and find it acceptable. This issue may be the subject of on-site verification.
Sincerely,
?.f Chan'.lu P. Patel, Project Manager Project Directorate III-2 Division of Reactor Proje::ts III, IV, V, and Special Projects cc: See next page i
i 1
J
Mr.- Thomas J. Kovach Zion Nuclear Power Station Commonwealth Edison Company-Units 1 ano 2 cc:
Robert J. Yollen, Esquire Mr. Michael C. Parker, Chief 109 North Dearborn Street Division of Engineering
~
Chicago, Illinois 60602 Illinois Department of Nuclear Safety Dr. Cecil Lue-Hing 1035 Outer Park Drive, 5th Floor Director of Research and Development Springfield, Illinois 62704 Metropolitan Sanitary District of Greater Chicago 100 East Erie Street
' Chicago, Illinois 60611 Phillip Steptoe, Esq.
Sidley and Austin One First National Plaza Chicago, Illinois 60603 Mayor of Zion Zion, Illinois 60099 Illinois Department of Nuclear Safety ATTN: Manager, Nuclear Facility Safety 1035 Outer Park Drive, 5th Floor Springfield, Illinois 62704 U.S. Nuclear Regulatory Commission Resident Inspectors Office 105 Shiloh Blvd.
Zion, Illinois 60099 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road, Bldg. #4 Glen Ellyn, Illinois 60137
- _ _ - _