Application for Amend to License NPF-12,revising Tech Spec Tables 2.2-1 & 3.3-4 Re Reactor Trip Sys Instrumentation Setpoints & ESFAS instrumentation.WCAP-12190 & Proprietary WCAP-12189 encl.WCAP-12189 Withheld (Ref 10CFR2.790)
ML20247M808
Person / Time
Site: Summer 
Issue date: 07/21/1989
From: Bradham O
SOUTH CAROLINA ELECTRIC & GAS CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML19292J364 List:
References
NUDOCS 8908020233
Download: ML20247M808 (2)


Text

South C::rolin2 Eltetric & Gu CompIny Olli S.

r him Jenkinsville. SC 29065 Nuclear Operabons (803) 345-4040 SCE&G t u-w."

July 21, 1989 Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 Technical Specifications Change Request - RTD Bypass Elimination Gentlemen:

South Carclina Electric & Gas Company (SCE&G) hereby requests an amendment to Table 2.2-1 of Technical Specifications Section 2.2.1, " Reactor Trip System Instrumentation Setpoints," and Table 3.3-4 of Technical Specifications L

Section 3.3.2, " Engineered Safety Feature Actuation System Instrumentation."

Specifically, this proposed amendment supports a plant modification to remove and replace the existing resistance temperature detector (RTD) bypass manifold system with fast response RTDs located in the reactor coolant hot and cold leg piping. This modification is designed to eliminate the operating obstacles associated with the bypass system such as leakage through valves and flanges and radiation exposure during reactor building maintenance. The proposed Technical Specification amendments reflect revised instrumentation setpoints associated with the longer response times of the fast response RTDs.

The marked up pages for the proposed amendments to Tables 2.2-1 and 3.3-4 are g

provided in Attachment 1.

The proposed no significant hazards evaluation is provided in Attachment 2.

Also provided as Attachments 3 and 4 respectively, are Westinghouse WCAP-12189 (Proprietary Class 2) and WCAO-12190 (Non-Proprietary), "RTD Bypass Elimination Licensing Report for V. C. Summer Nuclear Station." These reports provide the technical basir for the modification and the requested Technical Specifications changes. Additionally as Attachment 5, Westinghouse Letter " Application for Withholding Proprietary Information from Public Disclosure" (CAW-89-065) with Affidavit CAW-88-131 are also provided.

As WCAP-12189 contains information proprietary to Westinghouse Electric Corporation, it is supported by an affidavit signed by Westinghouse, the owner of the information. The affidavit sets forth the basis on which the information may be withheld from public disclosure i>y the Commission and addresses with specificity the considerations listed in paragraph (b)(4) of Section 2.790 of the Commission's regulations.

APOl I f Ct4 6f_

I__76_

ENCA

@O J

33 09 3

CK05f939G

, ppg i

tre P

PDC tvS I C I

f^ A

/^#

/v4c /0/2 f

~

Document Control Desk

~ July 21, 1989-Page 2

'Accordingly -it is repertfully requested that the information which is l

proprietary to Westinghouse be withheld from public disclosure in accordance with 10CFR Section 2.790 of the Commission's regulations.

Correspondence with respect to the proprietary aspects of the Application for Withholding or the supporting Westinghouse Affidavit should reference CAW 065 and'should be addressed:

R. A. Wiesmann, Manager of Regulatory &

Legislative Affairs, Westinghouse Electric Corporation, P.O. Box 335, Pittsburgh, Pennsylvania. 15230-0355.

Thh request has been reviewed and approved by both the Plant Safety Review Committee and the Nuclear Safety Review Committee.

I declare that.the statements and matters set forth herein are true and correct to the best of my knowledge, information and belief.

Should you have any questions, please call at your convenience.

Very truly yours,

0. S. Bradham MDB/OSB:pkh Attachments c: