f Mr. Martin LJ Bowling, Jr.'

'May 20, 1998 Recov;ry ONicer - Tcchnical Sirvic:s

. Northeast Nuclear En::rgy Comp ny c/o Ms. Patricia A. Loftus

' Director-Regulatory Affairs P.O.' Box 128 Waterford, CT 06385

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING GENERIC LETTER 97-04, " ASSURANCE OF SUFFICIENT NET POSITIVE SUCTION HEAD FOR EMERGENCY CORE COOLING AND CONTAINMENT HEAT REMOVAL PUMPS," AT THE MILLSTONE NUCLEAR POWER STATION, UNIT NO. 2 (TAC NO. MA0010)

Dear Mr. Bowling:

The NRC staff issued Generic Letter (GL) 97-04, " Assurance of Sufficient Net Positive Suction

. Head for Emergency Core Cooling and Containment Heat Removal Pumps," on October 7, J

1997. The GL requested that licensees provide information necessary to confirm the adequacy of the net positive suction head available for emergency com cooling and containment heat removal pumps. By letter dated January 5,1998, as sur ented on February 11,1998, Northeast Nuclear Energy Company'(NNECO) submittt day response to GL 97-04. The staff has reviewed NNECO's response, and has determin%. 4at additional information is -

necessary. Please provide the enclosed request for additionalinformation within 30 days from the date of this letter.

If you should have any questions regarding this request,' please contact me at (301) 415-1408, Sincerel Or signed by:

Daniel G. Mcdonald Jr., Senior Project Manager Special Projects Office - Licensing l Office of Nuclear Reactor Regulation Docket No. 50-336 DISTRIBUTION 90elest File.

DScrenci, RI POBLIC" LBerry

Enclosure:

A4 stated SPO-L Reading JKudrick SPO Reading OGC cc w/ encl: See next page WTravers' ACRS PMcKee KKavanaugh DMcDonald RCaruso JDurr,RI i

DOCUMENT NAME: G:\\ MCDONALD \\MA0010 RAI

- Indicate in box: "C"=Co ay_w/o enci "E"= Copy vvenct "N"=No Copy L.A OFFICE SPO-L:lA,a %PO-L:M Si$ _\\DD SFMB 6 SCSB /h1 r

NAME DMcDonal@

~

LBerry XCi/

PP Ick ed R R uso JKudrjic0d3/)f/ )

fDi DATE 05/ lT/98 ~

05/ J 6 /98 '

05/1D /98 05/ IK 198 05/lM/987[ F

/

OFFICIAL RECORD COPY g PU i

i 9905260172 980520

?

PDR ADOCK 05000336 5

P PDR s

a n.. *L w q,; *,** *.7C~~mm %m&,,

w - 6,, G Q ' p

p @ nliu p

t UNITED STATES g

j NUCLEAR REGULATORY COMMISSION g

WASHINGTON, D.C. 3086H201 May 20, 1998 Mr. Martin L Bowling, Jr.

Recovery Officer - Technical Services Northeast Nuc! ear Energy Company c/o Ms. Patricia A. Loftus Director-Regulatory Affairs P.O. Box 128 Waterford, CT 06385

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION REGARDING GENERIC LETTER 97-04, " ASSURANCE OF SUFFICIENT NET POSITIVE SUCTION HEAD FOR EMERGENCY CORE COOLING AND CONTAINMENT HEAT REMOVAL PUMPS," AT THE MILLSTONE NUCLEAR POWER STATION, UNIT NO. 2 (TAC NO. MA0010)

Dear Mr. Bowling:

The NRC staff issued Generic Letter (GL) 97-04, " Assurance of Sufficient Net Positive Suction Head for Emergency Core Cooling and Containment Heat Removal Pum;:s," on October 7, i

1997. The GL requested that licensees provide information necessary to confirm the adequacy j

of the net positive suction head available for emergency core cooling and containment heat removal pumps. By letter dated January 5,1998, as supplemented on February 11,1998, Northeast Nuclear Energy Company (NNECO) submitted its 90-day response to GL 97-04. The staff has reviewed NNECO's response, and has determined that additionalinformation is -

necessary. Please provide the enc!csed request for additonalinformation within 30 days from i

the date of this letter.

if you should have any questions regarding this request, please contact me at (301) 415-1408.

Sincerely, t

v s

Daniel G. Mc onald Jr., Senior oject Manager Special Projects Office - Licensing Office of Nuclear Reactor Regulation Docket No. 50-336

Enclosure:

As stated cc w/ encl: See next page 4

l'

REQUEST FOR ADDITIONAL INFORMATION GENERIC LETTER (GL) 97-04 MILLSTONE NUCLEAR POWER STATION. UNIT 2 DOCKET NO. 50-336 The fotbwing information is needed for the staff to complete its review of NNECO's responses to GL 97-04, " Assurance of Sufficient Net Positive Suction Head for Emergency Core Cooling and Containment Heat Removal Pumps," dated October 7,1997.

1.

What !s the maximum sump temperature assumed in the high pressure safety injection (HPSI) and the low pressure safety injection net positive suction head (NPSH) analyses?

2.

What is the NPSH required, and NPSH available for HPSl? Provide the actual numbers.

3.

In the GL response dated January 5,1998, the NPSH required and NPSH available for the containment spray pumps was provided based on subcooled sump water temperature.

What is the subcooled sump temperature that was used?

4.

In a letter dated February 11,1998, the NPSH required and NPSH available for the containment spray pumps was provided based on saturated conditions of 212 degrees.

Wnich NPSH analysis for containment spray is considered to be the Millstone 2 licensing basis?

Enclosure

Millstone Nuclear Power Station Unit 2 cc:

l Lillian M. Cuoco, Esquire Mr. F. C. Rothen l

Senior Nuclear Counsel Vice President-Work Services Northeast Utilities Service Company Northeast Utilities Service Company l

P. O. Box 270 P. O. Box 128 Hartford, CT 06141-0270 Waterford, CT 06385

~

Mr. John Buckingham Ernest C. Hadley, Esquire Department of Public Utility Control 1040 B Main Street Electric Unit P.O. Box 549 10 Liberty Square West Wareham, MA 02576 New Britain, CT 06051 Mr. John F. Streeter Mr. Kevin T. A. McCarthy, Director Recovery Officer - Nuclear Oversight Monitoring and Radiation Division Northeast Utilities Service Company Department of Environmental Protection P. O. Box 128 79 Elm Street Waterford, CT 06385 Hartford, CT 06106-5127 Mr. David B. Amerine Regional Administrator, Region i Vice President - Human Services U.S. Nuclear Regulatory Commission Northeast Utilities Service Company 475 Allendale Road P. O. Box 128 King of Prussia, PA 19406 Waterford, CT 06385 First Selectmen Mr. Allan Johanson, Assistant Director Town of Waterford Office of Policy and Management Hall of Records Policy Development and Planning 200 Boston Post Road Division Waterford, CT 06385 450 Capitol Avenue - MS# 52ERN P. O. Box 341441 Mr. Wayne D. Lanning Hartford, CT 06134-1441 Deputy Director of Inspections Special Projects Office Mr. M. H. Brothers 475 Allendale Road Vice President - Operations King of Prussia, PA 19406-1415 Northeast Nuclear Energy Company P.O. Box 128 Charles Brinkman, Manager Waterford, CT 06385 Washington Nuclear Operations ABB Combustion Engineering Mr. J. A. Price 12300 Twinbrook Pkwy, Suite 330 Director-Unit 2 Rockville, MD 20852 Northeast Nuclear Energy Company P.O. Box 128 Senior Resident inspector Waterford, CT 06385 Millstone Nuclear Power Station c/o U.S. Nuclear Regulatory Commission P.O. Box 513 Niantic, CT 06357

I t

  • g Millstone Nuclear Power Station Unit 2 cc:

Mr. B. D. Kenyon (Acting)

Attorney Nicholas J. Scobbo, Jr.

Chief Nuc,er Officer-Millstone Ferriter, Scobbo, Caruso, Rodophele, PC Northeast Nuclear Energy Company 1 Beacon Street,11th Floor P.O. Box 128 Boston, MA 02108 Waterford, CT 06385 Mr. J. P. McElwain l

Citizens Regulatory Commission Recovery Officer-Millstone Unit 2 ATTN: Ms. Susan Perry Luxton Northeast Nuclear Energy Company 180 Great Neck Road P. O. Box 128 l

Waterford, CT 06385 Waterford, Connecticut 06385 Deborah Katz, President Citizens Awareness Network P. O. Box 83 Shelburne Falls, MA 03170 The Honorable Terry Concannon Co-Chair Nuclear Energy Advisory Council Room 4035 Legislative Office Building Capitol Avenue Hartford, CT 06106 Mr. Evan W. Woollacott Co-Chair Nuclear Energy Advisory Council 128 Terry's Plain Road Simsbury, CT 06070 Little Harbor Consultants, Inc.

Millstone -ITPOP Project Office P. O. Box 0630 Niantic, CT 06357-0630 Mr. Daniel L. Curry Project Director Parsons Power Group Inc.

2675 Morgantown Road Reading, PA 19607 Mr. Don Schopfer Verification Team Manager Sargent & Lundy 55 E. Monroe Street Chicago,IL 60603 l

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _