HBL-20-012, Responses to NRC Requests for Additional Information on the Final Status Survey Reports for the Humboldt Bay Power Plant
| ML20247J598 | |
| Person / Time | |
|---|---|
| Site: | Humboldt Bay |
| Issue date: | 09/03/2020 |
| From: | Welsch J Pacific Gas & Electric Co |
| To: | Document Control Desk, Office of Nuclear Material Safety and Safeguards |
| References | |
| HBL-20-012 | |
| Download: ML20247J598 (14) | |
Text
James M. Welsch Senior Vice President Generation and Chief Nuclear Officer Diablo Canyon Power Plant P.O. Box 56 Avila Beach, CA 93424 805.545.3242 E-Mail: James.Welsch@pge.com September 3, 2020 PG&E Letter HBL-20-012 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No. 50-133, License No. DPR -7 Humboldt Bay Power Plant, Unit 3 Responses to NRC Requests for Additional Information on the Final Status Survey Reports for the Humboldt Bay Power Plant
Reference:
- 1. PG&E Letter HBL-20-007, Final Status Survey Report for the Humboldt Bay Power Plant Reactor Caisson Survey Units, dated April 1, 2020 (ML20092M643)
- 2. PG&E Letter HBL-20-011, Response to NRC Request for Additional Information on the Final Status Survey Report for the Caisson, Survey Units NOL01-09 and NOL01-09-FSR, July 20,2020
- 3. PG&E Letter HBL-20-010, Final Status Survey Report for the Humboldt Bay Power Plant Trailer City Area, dated May 21, 2020 (ML20142A287)
- 4. Email from NRC Project Manager, John B. Hickman, FSSR Items, dated July 29, 2020
- 5. Email from NRC Project Manager, John B. Hickman, Last Question on Caisson FSSR, dated August 12, 2020
Dear Commissioners and Staff:
In Reference 1, Pacific Gas and Electric Company (PG&E) submitted the Final Status Survey Report for the Humboldt Bay Power Plant Reactor Caisson Survey Units and in Reference 2 provided responses to requests for additional information regarding this report. In Reference 3, PG&E submitted the Final Status Survey Report for the Humboldt Bay Trailer City Area. In References 4 and 5, the NRC provided requests for additional information (RAIs), regarding the reports. The Enclosure to this letter provides PG&E responses to the RAIs.
PG&E makes no new or revised regulatory commitments (as defined in NEI 99-04) in this letter.
m PacHic Gas and Electric Company*
Document Control Desk PG&E Letter HBL-20-012 September 3, 2020 Page 2 If you have any questions or require additional information, please contact Mr. Philippe Soenen at (805) 459-3701.
Sincerely, James M. Welsch Senior Vice President Generation and Chief Nuclear Officer Enclosure cc:
Humboldt Distribution cc/enc: John B. Hickman, NRC Project Manager Scott A. Morris, NRC Region IV Administrator
/Maureen Zawalick for James Welsch
Enclosure PG&E Letter HBL-20-012 Page 1 of 12 Responses to NRC Requests for Additional Information on the Final Status Survey Reports for Humboldt Bay Power Plant
References:
- 1. PG&E Letter HBL-20-007, Final Status Survey Report for the Humboldt Bay Power Plant Reactor Caisson Survey Units, dated April 1, 2020 (ML20092M643)
- 2. PG&E Letter HBL-20-011, Response to NRC Request for Additional Information on the Final Status Survey Report for the Caisson, Survey Units NOL01-09 and NOL01-09-FSR, dated July 20, 2020
- 3. PG&E Letter HBL-20-010, Final Status Survey Report for the Humboldt Bay Power Plant Trailer City Area, dated May 21, 2020 (ML20142A287)
The applicability of the above references to the requests for additional information (RAIs) is specified below.
RAI # 1 (References 1, 2, and 3):
No discussion is present regarding residual radioactivity in the groundwater media, please provide residual radioactivity concentrations.
Included below are well water monitoring results for 2015, 2016, and 2017, three of the years with the highest potential for ground water impact from cutter soil mix (CSM) wall and caisson excavation work. Essentially, these values have remained the same since the start of active DECON in 2009. It is PG&Es opinion that previous spent fuel leakage, prior to managing leakage by maintaining an inward differential, was eliminated through decay and water flow.
Enclosure PG&E Letter HBL-20-012 Page 2 of 12 Groundwater Monitoring Summary (2015-2017)
(Groundwater monitoring ceased 3rd quarter 2017)
All Indicator Location with Highest Annual Control Type and Total Lower Limit Locations Mean Locations Number of Non Medium or Pathway Year Number of Analyses of Detection routine Sampled Performed (LLD)
- Mean, Mean, Mean, (Fraction) Mean, Reported (Fraction) &
(Fraction) &
(Fraction) & Measurements
[Range] b
[Range] b
& [Range] b
[Range] b Co-60 Cs-137 Co-60 Cs-137 Co-60 Cs-137 Co-60 Cs-137 Co-60: 15pCill c:MDA c:MDA NIA NIA c:MDA c:MDA NIA NIA Gamma Isotopic (24)
Cs-137: 1 8 pCill (0/24)
(0/24)
(0/24)
(0/24) 0 2017 ----------- -------- I~~ - - !tl~L-
[NIA]
[NIA]
~--------------- --------
ODCM: 2.0E+03 Tritium (50) pCill c:MDA, (0/50), [NIA]
c:MDA, (0/50), [NIA] c:MDA, (0/50), [NIA]
NIA 0
Plant Policy: 400 Co-60 Cs-137 Co-60 Cs-137 Co-60 Cs-137 Waterborne Co-60: 15pCill c:MDA c:MDA Co-60 Cs-137 c:MDA c:MDA NIA NIA Gamma Isotopic (50) 0 Groundwater Cs-137: 1 8 pCill (0/50)
(0/50)
NIA NIA (0/50)
(0/50) 2016
[NIA]
[NIA]
[NIA]
[NIA]
(Monitoring wells)
-------- -------- --------~--------------- --------
ODCM: 2.0E+03
[pCi/L]
Tritium (50) pCill
<MDA, (0/50), [NIA]
<MDA, (0/50), [NIA] <MDA, (0/50), [NIA]
NIA 0
Plant Policy: 400 Co-60 Cs-137 Co-60 Cs-137 Co-60 Cs-137 Gamma Isotopic (56)
Co-60: 15pCill c:MDA c:MDA Co-60 Cs-137 c:MDA c:MDA NIA NIA 0
Cs-137: 1 8 pCill (0/56)
(0/56)
NIA NIA (0/56)
(0/56) 2015 l~~--!tl~L-
[NIA]
[NIA]
~--------------- --------
ODCM: 2.0E+03 Tritium (56) pCill c:MDA, (0/56), [NIA]
c:MDA, (0/50), [NIA] c:MDA, (0/56), [NIA]
NIA 0
Plant Policy: 400 I
Results identified as "c:" are not included in the calculation of average and maximum values I
I bThe mean and the range are based on detectable measurements only. The fraction of detectable measurements at speclfied locations ls indicated in parenthes,es; e.g., (10112) me.ans that 10 out of 12 samples contained detectable activity. The range of detected results is indicated [n brackets; e.91.,
[23 to 34].
Enclosure PG&E Letter HBL-20-012 Page 3 of 12 2017 Results (Groundwater monitoring ceased 3rd quarter 2017)
TABLE C-4 GROUNDWATER MONITORING WELL RESULTS Monitor Alpha Bet.a Gamma Tritium Well Sample Activity Activi.ty Activity Activity Number Date (pCi/L)
(pCi/L)
{pCi/L)
(pCi/L)
2/15/2017
< 4.39 (MOA) 2.53 +/- 1.13
<4.01 (MDAl
< 1.83 MDA
< 312 MDA)
R~W-SFP-2*
2/15/2017
< 35.6 (MOA)
< 13.7 (MDA)
<4.17 (MDA)
<4.56 MDA
< 312 MDA)
RCW-SFP-3*
2/15/2017
< 58.6 (MDA)
< 17.9 (MDA)
< 5.06 (MDA)
< 5.44 MDA
< 297 MDA)
RCW-SFP-4' 2/15/2017'
< 16.5 (MDA) 15.1 +/- 5.01
< 3.66 (MDA)
<4.25 MDA
< 311 (MDA)
RCW-SFP-5" 2/15/2017
<21.7 (MDA)
< 10.B <MDA)
< 5.16 !MDAl
< 4.41 MDA\\
<306/MDA)
RCW-SFP-6*
2/15/2017
<2.85 (MDA) 0.897 +/- 0.576
<4.03 (MDA)
<4.38 (MDA)
< 309 (MDA)
RCW~cs..s*
2115/2017
< 2.93 (MDA) 2.3+/- 0.783
< 3.03 (MDA)
< 3.51 (MDA)
< 295 (MDAt RCW-CS-.s*
2/15/2017
< 198 (MDA)
< 72.2 (MDA)
<4.06 (MDA)
< 3.07 MDA
<311 MDA)
RCW-CS-7" 2/15/2017
< 207 {MDA) 97.7 +/- 50
< 3.50 (MDA)
<4.05 (MDA)
< 299 (MDA)
RCW-CS-s*
2/15/2017
< 144 (MDA)
< 90.7 {MDA)
< 3.43 {MDA)
< 3.05 MDA
< 307 MDA)
RCW-CS-9" 2/15/2017
< 104 (MDA)
< 40.8 (MDA)
< 6.19 (MDA)
< 5.53 MDA
< 307 MDA)
RCW-Cs-10~
2/15/2017
< 35.9 (MDA)
< 12.3 (MDA)
< 4.05 (MDA)
< 3.98 MDA)
< 313 MDA)
- I d" t 12 n,ca es groun wa er mom onng we s.
d I
II Monitor Alpha Beta Gamma Tritium Well Sample Activity Activity Activity Activity Number Date (pCi/L)
(pCI/L)
(pCi/L)
(pCi/l)
5/5/2017
< 5.42 (MDA)
< 3.02 (MDA)
< 5.68 MDA)
< 4.91 (MDA)
< 305 MDA)
RCW-SFP-2*
5/512017
< 87.2 (MDA)
< 16.8 (MDA)
< 3.18 MDA)
< 3.05 (MDA)
< 308 MDA)
RCW-SFP-3*
515/2017
< 38.3 (MDA) 27.3-+/-8.17
< 3.00 MDA)
< 4.15 (MDA)
< 305 (MDA)
RCW-SFP-4*
5/5/2017
< 22.6 (MDA) 10.9'+/-4.19
< 3.36 {MDA)
< 3.83 {MDA)
< 304 (MDA)
RCW-SFP-5..
5/5/2017
< 24.1 (MDA)
< 16.6 (MDA)
< 4.94 (MDA)
<4.05 (MDA
< 296 MDA)
RCW-SFP*6*
5/5/2017
<2.92 (MDA) 2.01 +/- 0.964
< 3.48 (MDA)
< 3.20 (MDA)
< 296 (MDA)
RCW-Cs-s~
5/5/2017
< 2.77 (MDA) 3.02 +/- 1.07
< 3.03 (MDA)
<4.19 (MDA)
< 290 (MDA)
RCW-CS-6*
5/5/2017
< 138 (MDA)
< 92.8 (MDA)
<4.69( MDA)
<2.69 (MDA
< 310 MDA)
RCW*CS-7*
5/512017
<260 (MDA)
< 153 (MDA)
<4.441 MDA)
<3.96 (MDA
< 325 MDA)
RCW-CS-8" 5/5/2017
< 143 (MDA)
< 108 (MDA)
<4.641 MDA)
< 3.62 (MDA1
<320 MDA)
, RCW-CS-9" 5/5/2017
< 63 (MDA)
< 47.6 (MDA)
<4.08 MDAl
< 4.21 [MDA
<322 MDA)
. RCW-CS-10*
5/5/2017
< 33.5 (MDA) 17_3, +/- 9.45
<3.59 (MDA)
< 3.37 (MDA)
< 308 (MDA)
- rndicates 12 groundwater monitoring wells.
Enclosure PG&E Letter HBL-20-012 Page 4 of 12 Table C-4 Notes:
- 1.
Monitoring wells RCW-SFP-4 and RCW-CS-8 were located adjacent to each other in a small depression in the FSS area of the upper yard. During the first quarter well sampling event of 2017, some dirt and gravel were found to be covering the well lids. As a result, turbidity measurements for both wells were elevated. The increased sediment in the water was most likely due to surface influence rather than a significant disturbance in the water column or excessive stress placed on the formation. GEL Labs was advised of the higher than normal turbidity measurements and was requested to allow any sediment in the samples to settle before analyses Were performed. The GEL data report for monitoring wells RCW-SFP-4 and RCW-CS-8 appeared to be in line with values seen previously. This actfon was documented in corrective action SAPN 1428500.
- 2.
On February 27, 2017, GEL Labs advised via email that the H-3 sample for monitoring well RCW-CS-5 was damaged during shipment and the sample was lost. GEL collected a H-3 sample from the nitric acid preserved sample. GEL reported H-3 activity for RCW-CS-5 as less than 295 pCi/L, which is a normal value for H-3 activity in HBPP monitoring wells and less than the required LLD of 400 pCi/L. This action was documented in corrective action SAPN 1428501.
Enclosure PG&E Letter HBL-20-012 Page 5 of 12 2016 Results TABLE C-4 GROUNDWATER MONWTORING WELL IRIESULTS Monitor Alpllla Beta Gamma Tritium Welll Sample Activity Activity Activity Activity
!Number
- Date, fpCi/L)
(p:Ci/1L)
(pCI/L}
,(pCIIL),
Cs-137 Co-60 MW-1 1" 2/1112016
<3.58 6,59 +/- 1.97
<4,61
< 4,96
< 306 RCW-SFP-1~
2/11/2016
<21.8
< 12.2
<4.97
< 5.68
< 302 R!CW-SFP-2*
2/1H2016
< 25.9 17.2 +/- 10.9
< 5.12
< 4. 01
< 30:8 RCW-SFP-3"'
2/1112016
<45.6
< 30.8
< 6.. 17
<5.H
< 306 RCW-SF;P-4,"'
3/1112016
< 32.1
< 20.5
<4.77
< 4.61
<297 RCW-SFP-5"'
2/11/2016
.< 34.3
<20,5
< 5.83
< 5.74
< 307 I
RCW-SFIP-6
2/1112016
< 3.72
< 2.10
< 4.85
< 4.82.
< 306 RCW.CS*S" 2/1 1/2016
<2.61 3.90 +/-1.35
< 3.81
<4.79
< 308 RCW..CS*fl*
2/11/2016
< 112
< 104
< 5.13
<4!.34
<307 RCW-CS-7*
2/11/2016
< 169
< 102
<4.42
<4,67
< 303 Rew-es.a--
2/11/2016
< 201
< 143
< 4.87
<4.95
< 307 RCW-Cs.9*
2/11/2016
< 102
< 71.1
< 5.07
< 5.53
< 301 RCW..CS-1*0*
2/11/2016
<36.0
< 23.0
< 4.5:2
< 4!.83
<299 h
~ ndl1c:ates t irtee:n (1 3 ) groundwater rnonitorin! wells.
MW-11" 5110/2.016
< 1.95
< 2.15
<5.87
< 3.53
<336 RCW-SFP-1*
5/10.12016
< 4.79
< 5.1 1
< 3.90
< 4,96
<334 RCW-S'FP-2*
5110/2016
<22.a
< 23.6
<4.62
< 5.50
<339 RCW-SfP-3*
5/10/2016
< 68.7
< 25.2
<4.35
<4,08
< 335 RCW-SIFP-4,*
5110/2016
< 43.9
< 21.7
< 5.71
< 5.16
< 335 RCW-SFP*S*
5/10/2016
< 45,2
< 14.9
<4.77
< 3.53
< 339 RCW-S'FP-'6" 5/10/2016
< 3.14
< 1.70
<4.56
<4.38
< 336 RCW*C8'"5*
5/10/2016
< 3.08 4.46 +/- 2.39
< 3.72
<4.88
< 338 RCW-CS-6*
5/10/2016
< 123
< 129
< 5.3,7
<4.21
< 338 RCW-CS-7" 5/10/2016
< 112 104 +/- 59
< 4.49
< 5.47
.:342 I RCW-CS,-8,*
5/10/2016
< 105
< 85.1
<3.54
< 5.24
< 331 11 RCW-CS-8~
5/10/2016
< 75.8
< 58.3
< 2.88
< 3.10
< 301
, RCW-CS 10"'
5/10/2016
< 23.6
< 17.6
< 3.86
< 4.37
< 338
- l11dicates thirtee11 {13) groundwater mo11itorin! wells.
MW-HI~
812.3/2016
< 3.84 3.07 ;1;; 1.19
<3,34
<2.29
< 296 I RCW-SFP-2'"
8123/2016
< 46.2
< 23.4
< 3.23
< 3.49
< 302 RCW-SFP-3" 6123/2016
< 42,0
< 29.0
< 3.99
<2.33
< 288 RCW*SFP-4t 8/23/20116
< 57.1
< 35.0
< 3.31
< 4.46
< 292
, RCW*SFP-5" 8/23/2016
< 43.3
< 13.8 I
< 5.06
< 3.25
< 294 I RCW-SFP.S" 8/23/2016
< 2.27 1.99 +/- 0.98
< 4.04
< 3.97
< 298 RCW-CS-5" 8/23/2016
< 3.28 2.6"9 +/- O.M
< 4.15
< 4.00
< 2.98 RCW°CS-6*
8/23/20116
< 121
< 110
< 5.83
< 6.8,7
< 289 R-CW-CS-7" 8/2312016
< 255
< 119
< 5.13
< 4.68
< 299 R1CW-C.S-8" 8/23/2016
< 191
< 80.6
< 3.21
< 3.71
< 299 R*CW-C.S-r 8/23/201*6
< 84.4
< 57.0
< 3.94
< 5.21
< 298 RCW-C.S-10~
,8/23/2016
< 37.8
< 20.5
<4.51
< 6.76
< 304
- Indicates twelve, 12 t ) g m undwal.er mon llorir1 g wells.
Enclosure PG&E Letter HBL-20-012 6 of 12 2016 Results (continued)
Monitor Well Number MW-n*
R:CW-SFP'-2!
~CW-SFP-3~
RCW-SFP-4*
RCW-SFP*-:S*
RCW-SFP-e*
IRCW-CS-5t RCW-CS-s*
RCW-CS-7"'
RCW..CS-8..
RCW-CS*9" RCW-CS-10"'
TABLE C-4 (Continued)
GROUNDWATER M:ONITORING, WELL RES UL TS Al1pha Beta Gamma Sample Activtt.y ActivUy ActMly nate (pCil )
,(pCifL)
,{pCi/L)
Cs~137 11/10/2016
< 5.08 3.76 +/- 1.29
< 5.93 11/10/2016
<46.9
< 16,9
< 5.38 11/10/2016
<46.3
< 22.9
< 4.69 11/10/2016
<62.7
<24.2
< 6.02 111/10/2016
..:*25.1
..: 112.7
< 3.41 111/1012016
< 2.90 1.50 +/- 0.86
<3.80 11/10/2016
<2.94 2.63.+/- 1.05
< 3.91 11/10/2016
< 158
< 77.3
<3.29 11/10/2016
< 233
< 87.0
< 4.37 11/10/2016
< 210
<85.4
< 3.68 11/10/2016
< 91.2
<45.7
<3.87 11/10/2016
<43.4
<20,6
<3.95 Indicates twelve (12) groundwater monitoring wells.
Tritium Ac!Mty (pCi/L) 1C*0--'6101
< 4.05
< 281
< 6.25
<.284
< 3.92
<.282
< 4.28
<279
..: 3.69
<274
< 3.98
<.281
< 5.64
<275
< 3,85
<273
< 3.83
< 273
< 4.02
<280
< 4.30
<276
< 4_39,
<278
Enclosure PG&E Letter HBL-20-012 Page 7 of 12 2015 Results TABLE C-4 GROUNDWATER MONITORING WEL RIESULTS M'onitor Alpha Beta Gamma Tritium Well Samplo Activity Activity Activity Activity Number Date (pCif )
(pCI/L) fpCflL)
{pCi/L)
Cs-1137 Co~60 i MW-11*
2/1612015
< 5.36 (MDA) 8_14 + 2.17
<: 6.23 MDA
< 5.40(MDA)
< 321 (MDA)
RCW-SFM*
2/16/2015
< 2.36 [MDA) 4.19'+/- 1.25
<5.59 MDA
< 5.77(MDA]
< 324 IMDA)
RCW-SFP*2*
2/16/2015
< 9.97 (MDA)
<0,38 MDA
< 5_55 (MDA)
< 4.28(MDAl
< 314 (MDA)
RCW-SFP-3" 2/16/2015
< 6.66 (MDA) 7.63 :I: 2.97
< 4.72 MDA
< 5.20(MDAl
< 316(MDA)
RCW-SFP-4*
2/16/2015
< 5.62 [MDA) 4.7S +/- 2.31
<4.45 MDA
< 4.47 (MDAl
< 320{MDA)
RCW-SFP.-5,k 2116/2015
< 7.08 (MDA',
< 3.81 rMDA
< 5.14 MDA
< 4.10(MDA)
< 314{MDA)
RCW0SFP*6*
2/16/2015
< 12.2. [MDA)
< 10.0 MDA
<6.09 MDA
< 6.57 {MDA)
< 319<MDA}
i RCW-CS-3° 2/16/2015
< 1.75 (MDA"
< 1.94 MDA
< 4.70 MDA}
< 3.07 (MDA)
< 325(MDA}
RCW-CS-5" 2/16/2015
< 2. 90 (MDA),
3_81 +/- 1.60
< 4.93 CMDA
< 5.15(MDA)
< 328(MDA)
RCW-CS-6*
2/16..12015
< 115 CMDA\\
< 83.1 MDA
< 5.42 MDA
< 3.83 (MDA)
< 322{MDA}
RCW-CS-7" 2/1612015
< 135 (MDA}
< 87.2 (MDA
<6.26 MDA
< 6.74 (MDAl
< 334(MDA}
RCW*CS-8" 2/16/2015
< 147 (MDA)
< 92.7(MDA
< 5.07 MDA}
< 7.00(MDAl
< 311 (MDA}
RCW-CS-9*
2/16/2015
< 23.7 (MDA)
< 31.6 (MDA1
< 5.05 (MDA)
< 4.75 (MDA1
< 323(MDA)
RCW-CS-10" 2/16..12015
< 25.2 [MDA}
< 21.6 MDA
< 3.93 MDA
< 3.80(MDA)
< 325'MDA)
MW-11" 5/13/2015
< 1*1.2 rMDA)
< 10.70 (MDA
< 4.19 MDA
< 4.26 (MIDA)
< 346(MDA)
RCW-SFP-1~
5/1312015
< 2.97 [MDA}
< 3.56 MDA
<4.54 MDA
< 3.44 (MOA)
< 346(MDA}
RCW-SFP-2~
5/13.12:015
< 16.2 rMDAl
< 9.*68 MDA
<6.31 MDA
< 6.76(MDA)
< 347{MDA)
RCW-SFP-3."
5113/2015
< 25.8 (MDA)
< 15.90 CMDA
< 3.73 MDA
< 4.60 (MIJAl
< 343{MDA}
RCW-SFP-4*
5113/2015
< 10.8 fMDAl
< 8.73 rMDA
<: 4.69 MDA
< 3.01 (MOA)
< 347(MOA}
RCW-SFP.-5*
5/13/2015 8.73 :1: 4.47
< 3.80 MDA
< 5.24 MDAI
< 5.72 (MOA)
< 326(MOA}
RCW-SFP-6~
5/13/2015
< 13.8 (MDA}
< 11.90 {MDA
<4.20 MDA
< 3.22 (MDA)
< 332 (MDA}
RCW-CS-3*
5/13/2015
< 3.05 (MDA}
< 2.49 MDA)
< 4.51 MDA
<6,W(MDA)
< 342 (MDA)
RCW-Cs-s*
5/13/2015
< 4.25 (MDA}
4.45+/- 1.85
< 4.60 MDA
< 4.59(MDA)
< 349(MDA}
RCW-CS-G*
5/13/2015
< 217 (MDA)
< 90.4 (MDA)
< 4.1.4 MDA
< 4.76(MDAl
< 391 (MDA}
RCW-CS-1*
5/13/2015 Note 1 Note 1 Note 1 Note 1
< 344 (MDA)
RCW*Cs-o*
5/13/2015
< 240 (MDA)
< 153 (MDA
< 3.97 (MDA)
< 4.05, (MDA-l
< 346(MDA}
RCW-CS-9" 5113/2015
< 29.5 (MDA)
< 20.2 (MDA
< 4.47 MDA)
< 4.71 (MDAl
< 350(MDA)
RCW-Cs-10*
5113/2015
< 30.1 (MDA)
< 20.4 (MDA
< 3.45 MDA)
< 4.64 (MDAl
< 344 (MDA}
MW-11*
8113/2015
< 22.0 (MDA)
< 10.9 MDA
< 3.93 MDA
< 4.81 (MDAl
< 219 {MDA}
RCW-SFP-1*
8/13.12015
< 23.5 (MDA)
< 16.0 (MDA\\
< 3.54 MDA
< 3.91 (MDA)
< 239(MDA)
RCW-SFP-2' 8/13/2015
< 16.1 (MDA)
< 11.3 MDA
< 3.46 MDA
< 3.85(MDAl
< 229{MDA}
RCW-SFP--3*
8/1312015
< 44.5 (MDA)
< 30.1 MDA
< 3.85 MDA
< 4.57 (MDAl
< 236<MDA)
RCW-SFP-4*
8/13/2015
< 38.5 (MOA)
< 20.3 MDA
<4.J9 MDA
< 5.06(MDAl
< 237 {MDA)
RCW-SFP-5t 8113/2015
< 13.1 (MDA)
< 8.19 MDA
< 4.42 MDA
< 4.08(MDAl
< 237(MDA}
RCW-SFP-,Gt 8/13/2015
< 11.8 (MOA)
< 6.71 MiDA
< 3.75 MDA)
< 2.97 (MDAl
< 248(MDA}
RCW-CS~3*
8/1312015
< 3.15 lMOA}
2.53:t 1.14
< 3.86 MDA
< 3.84 (MDA)
< 236 (MDA)
RCW-CS-5*
8/1312015
< 2.74 (MDA) 2.71 +/- 1.10
< 4.6:2 MDA
< 4.51 (MDAl
< 235 (MDA}
Rew.cs.a*
8/13/2015
< 122 (MDA)
<: 103 I MDA
< 3.94 MDA
< 3.37 (MDA)
< 243 (MDA)
RCW-CS~7..
8/1312015
< 353 (MDA}
<: 1451 MDA
< 2.94 MDA
< 3.18(MDAl
< 248(MDA}
I RCW-CS-8*
8/13/2015
< 139 (MDA)
< 107, MDA
< 5.2:Q MDA
< 4.82 (MDA)
< 239(MDA)
RCW-cs.9~
8/13/201 5
< 136 (MDA)
< 86.2 MDA1
< 4.75 MDA
< 4.57 (MDA}
< 232(MDA}
RCW-CS-10" 8/13/2015
< 39.9 (MDA}
< 28.5 (MDA>
< 233(MDA)
- lndlcales fourteen (14) groundwater monitoring we1ls_
Enclosure PG&E Letter HBL-20-012 Page 8 of 12 2015 Results (continued)
RAI # 2 (Reference 3):
Not all radionuclides of concern in Table 6.4 of the LTP are addressed in the surveys. Usually, only Cs-137 is addressed directly while many ROCs are deselected and otherwise accounted for. This leaves 6-7 ROCs not accounted for in the surveys. Please provide data for these ROCs.
In the deselection process Humboldt Bay Power Plant (HBPP) Radionuclides of Concern ( ROCs) that were determined to be insignificant in a particular Survey Unit were eliminated from the Final Status Survey (FSS) process (i.e. statistical evaluation). Their potential dose contribution was conservatively accounted for in demonstrating compliance [Ref. NUREG-1757 Vol. 2]. The dose contribution is not considered a surrogate since there is no comparison of this dose to another known dose contributor (e.g. Cs-137 value representing a value for a radionuclide not assayed for).
TABLE C-4 (Continued)
G
- OUNDWATER MONITORING WELl RESULTS Monitor Allpha Sota Gamma Tr,iHu1m Wol Sample Acthdty Actilvlty Act1ivity Activity Number l:lat
,(pCilL)
(pCIIL)
(,PCIIL)
(.f>CfliL)
1110912.015
< 5.83 (MDA)
< 4.82 (MDAl
< 3.57 MDA)
< 2.80 /MDA)
< 296 (MIDA)
RCW-SFr>-1~
11,09/2015
< 16.9 [MDAl
.:: 8.70 (MDA
<4.60 MDA)
< 4.27 ~MDA}
< 292 (MDA)
RCW-SFP-l*
11/09/2015
< 31.3(MDA1
< 1i'.5{MDA
<li.55 (MDA)
< 4.57 (MOA~
< 28S (MDA)
RCW-SFP-3" 11/09/2015
< 44.2 (MDA)
< 35.6 (MDA
< 3.08 MDA}
< 3.70 (MDA)
..: :297,(MDA}
RCW*SFP*-4~
11/09/2015
< 31.0 {MDA)
< 15.0 {MDA
<4.48(MDA).
< 5.45 (MDA)
< 293 iMDA}
RCW..:SFP*5~
11f09J201 5
< 18.1 (MDA)
< 5.28 (MDA
< 3.67 MDA)
<4.66 {MDA)
< 297 (MDAl RCW-SFP-6" 11/091.2015
< 4.30 (MDA)
< 3.71 (MiDAI
< 4.05 MDA)
< 4.61 (MDA)
< 288 (MDA)
RCW-CS-3*
11I09t2015
< 2.27 !MOA}
1.70 +/- 0.872
<4.87 MDA}
< 3.74 (MDA)
< 293 lMDA)
RCW-CS.S*
11109/2016
< 3.06.(MDA~
1.9fS +/- 0.921
< 4.38 MDAl
< 3.71 {MDA)
<.284 (MDA)
RCW-CS-6*
11/09/2015
< 183 (MOAl
< 131 (MDA)
< 4.78 MDAl
<: 4. 76 (MDA)
<292 (MDA)
RCW-Cs-1~
11/0,9/2015,
< 150 (MDA)
< 0.2.1 ~MDA
<4.38 IMDA)
< 4.52 {MDA)
< 294 (MDA)
RCW-CS-8"'
11/09/2015
< 145 (MDA)
< 95.5 {MDA
< 4.43 MDA>
< 5.53 (MDA)
< 282 (MDA)
RCW-CSa9*
11109/2015 117 +61.8
< 64.6 (MDA
< 3,891 1 MDA)
< 5.89 (MDA)
< 2 92,(MDAl, RCW*CS-10~
11/0912015
<33.8 (MDA)
< 15.0 (MDA
<6.401 MDA)
< 6.83 (MD1A)
< 304 {MDA),
lndica,as (14} groundwater mom(onog wells..
Table C-4 Notes:
- 1.
RCW-CS-7 was uno11ble I.a be purged during Ille second que1rter1ly groundwater sampling event aind water monitoring parameters were not oolleoted (conductivity, pli and turb:idily). Adequate volume of sample for gross allpha, gross beta, Am-241, Cs-137, Co-60 and Total Slrontium could not be obtained.
TI,e onlly sample oblained for offslte analysis was 1he 1-1-3 samnple. This action was doct.1me:rited in corrective action SAPf,,I 1406334.
Enclosure PG&E Letter HBL-20-012 Page 9 of 12 All radionuclides not deselected were analyzed for in each sample, and radionuclides that were detected were included in the statistical analysis. When there were multiple radionuclides identified the unity rule was implemented in determining the acceptance, or rejection, of the null hypothesis. The 6-7 ROCs mentioned in the RAI, assayed below the Minimum Detectable Activity (MDA)/Lower Limit of Detection (LLD) for the analysis. The FSS Plan requires that the analyses attempt to meet an MDA that is 10 percent of the radionuclides Derived Concentration Guideline Level (DCGL). HBPP conservatively far exceeds that requirement. When actual reported activities are recorded and their fractional contribution to unity is determined their contributions are insignificant to the statistical analysis as shown in the table for the nuclides in OOL09-01.
OOL09-01 Nuclide Mean Scaled DCGL Fraction Fraction Toward Unity*
-1.13E-02 3.47E+00
-3.26E-03 0.00 Eu-152
-3.55E-02 9.14E+00
-3.88E-03 0.00 Eu-154
-3.43E-03 8.59E+00
-3.99E-04 0.00 H-3 7.00E-02 6.22E+02 1.13E-04 0.00 Nb-94
-1.27E-02 6.49E+00
-1.96E-03 0.00 Np-237 1.79E-02 1.01E+00 1.77E-02 0.02 Sr-90
-2.47E-02 1.37E+00
-1.81E-02 0.00 Am-241
-3.46E-02 2.28E+01
-1.52E-03 0.00
- Unity values must be from 0-1. There can be no negative unity values.
As shown in the above example of OOL09-01, sample results showing the analysis below the MDA/LLD for the analysis for the non-deselected radionuclides provide no statistical significance to the unity determination.
RAI # 3 (Reference 3):
Please clarify why the deselection listing of ROCs is different in NOL09-08 vs the other survey units.
Much of the initial data used for calculations were based on limited characterization/FSS data, and as such those data were used to base initial criteria in a conservative manner. Additional data was gathered during decommissioning and used to update prior, albeit conservative, assumptions as to the potential dose contributions of deselected radionuclides. As this data was analyzed, and the
Enclosure PG&E Letter HBL-20-012 Page 10 of 12 methodology was updated, the dose contributions were updated as well to further reflect a more accurate radiological status of the HBPP site upon license termination.
The dose selections for Survey Units OOL09-01 through OOL09-07 and OOL09-09 through OOL09-10 reflect the earlier calculations and are, as such, more conservative estimates of the potential dose contributions for the deselected radionuclides. The dose selection for OOL09-08 presents a more accurate representation of the potential radiological status and dose contributions based on the more recent data evaluated.
RAI #4 (Reference 3):
Provide the depth of backfill in each of the survey units. Also, clarify whether, in each case, the last few feet of backfill originated from off-site after the surveys were performed.
The approximate depth of backfill was less than 1 meter over the entire Trailer City Area except for OOL09-01, which has a backfilled depth of approximately 22 feet. The estimated backfill for the area of the circulating water excavation in OOL09-01 was approximately 3,442 cubic yards of reuse GARDIAN material over an area approximately 28 feet wide, 150 feet long, and 22 feet deep.
All Final Site Restoration (FSR) surveys were performed after reuse material backfilling was completed and before placement of any off-site material (topsoil, engineered rock/gravel, concrete or asphalt and plants) was applied. For most of the Trailer City area, the depth of the off-site topsoil was approximately 6 inches to 1 foot.
Survey Units OOL09-01 and OOL09-09 also had gravel, concrete, and asphalt poured on top. There was approximately 1 to 2 feet of offsite road-base material placed on top of the final surveyed area prior to asphalt paving. The depth of the gravel for the catch basins in the area ranged from 6 inches to one foot.
RAI #5 (Reference 3):
If the backfill exceeded a depth of 1 meter, provide information regarding the non-surface volume of backfill and how it was shown to meet the release criteria for all ROCs.
All areas in Trailer City that were backfilled with onsite reuse material were on an average less than 1 meter in depth with the exception of OOL09-01 circulating water excavation. The circulating water excavation was on average 22 feet in depth with an average of approximately 28 feet wide and 150 feet long.
All reuse material used to backfill the deep excavation in OOL09-01 was monitored to be acceptable for reuse through the GARDIAN bulk monitoring systems on site. This
Enclosure PG&E Letter HBL-20-012 Page 11 of 12 backfill material in the deep excavation is the same material that was used to complete the backfill of the entire Trailer City area and final elevation of the discharge canal area (top of the excavation).
From a review of the analytical sampling of this backfill material from these areas, an MDA of approximately 0.1 pCi/g for Cs-137 was estimated. This value would be indicative of the remainder of the reuse material used to complete the backfill of the discharge canal, area 51 and circulating water excavations. In addition, a review of GARDIAN system data indicates that the backfill material would have displayed an approximate average MDA of 0.30 pCi/g for Cs-137 through the less accurate bulk reuse protocol.
RAI # 6 (References 1 and 2):
In response to RAI 2 [Reference 2 of this submittal] for the Caisson, you had the following notes:
Note 1 - Production of Cs-137 is greater than Nb-94 to start. The ratio of half-lives is provided below: 30 years for Cs-137 divided by 2.1 E+4 years for Nb-94 equals 1.4 E-3 (combined with production difference, less than a significant number for the sum of fractions calculation).
Note 2 - Production of Pu-239 is much greater than that of Np-237 because of direct neutron capture by U-238 vs. multiple decays and capture to produce Np-237. The ratio of half-lives is provided below: 2.4 E+4 years for Pu-239 divided by 2.14 E+6 years for Np-237 = 1E-2 (combined with difference in production, less than a significant number in the sum of fractions calculation).
Could you clarify what is meant by Production is greater to start and less than a significant number in the notes. Additionally, it appears that you are claiming there is a surrogate relationship between the stated radionuclides. If so, what is the impact to the surrogate radionuclide DCGL value per MARSSIM methods? Please clarify that the surrogate relationship will remain consistent given the difference in environmental transport mechanisms for the specified radionuclides (e.g., Np-237 is extremely mobile environmentally).
It appears to us that the one nuclide (or two in this case) is being used as a surrogate for the unreported nuclide(s) based on known production ratios and similar characteristics for environmental transport, and doing so has no impact on the applicable DCGL due to the difference in production rates and specific activity of the radionuclides. If you can provide the math to demonstrate this per MARSSIMs surrogate measurement process and demonstrate that the change to the surrogate radionuclides DCGL value is negligible (e.g., a delta less than 0.05 pCi/g would be appropriate for Cs-137s DCGL of 7.9 pCi/g), then we can find the logic adequate.
Enclosure PG&E Letter HBL-20-012 Page 12 of 12 PG&E Response to RAI # 6:
PNL-4628, Residual Radionuclide Distribution and Inventory at the Humboldt Bay Nuclear Plant states, "Although substantial amounts of Nb-94 may be produced by neutron activation of steel components within the pressure vessel, the extreme insolubility of niobium apparently prevents its dissolution from the neutron-activated steel, thereby minimizing any subsequent redisposition throughout other systems of the plant." Therefore, it is evident that all significant amounts of Nb-94 would be captured in the reactor internals waste streams that have been removed as part of HBPP decommissioning activities. It is also reasonable to assume that there are no residual amounts of Nb-94 present based on the table in PG&Es response to RAI #2 in this submittal, which shows a Nb-94 Sum of Fractions for survey unit OOL09-01 of 0.00, and a comprehensive review of HBPP Laboratory gamma analysis reports from all FSS samples collected at HBPP from decommissioning activities that indicates no positive detection of Nb-94 greater than method detection levels. It should be noted that if Nb-94 had been detected in any FSS sample, the survey unit dose contribution from the nuclide would have been included in the Sum of Fractions calculation for consideration relative to the release criterion.
Np-237 is produced from neutron absorption of U-235, a primary constituent in nuclear fuel, with a secondary production method from alpha decay of Am-241 (daughter of Pu-241, produced from neutron absorption of Pu-240). Np-237s long half-life of 2.144E+04 years, compared with its parent, Am-241, of 4.33E+02 years, is a factor of almost 50 longer. Additionally, it is unlikely that Np-237 would be present in a sample without Am-241 also being present. It is also reasonable to assume that there are no significant residual amounts of Np-237 present based on the table in PG&Es response to RAI #2 in this submittal, which shows a Np-237 Sum of Fractions for survey unit OOL09-01 of 0.02. A comprehensive review of HBPP Laboratory gamma analysis reports from all FSS samples collected at HBPP from decommissioning activities indicates no positive detection of Np-237 greater than method detection levels. Comprehensive review of FSS samples collected indicate that Am-241 has only been identified in three samples, all investigation samples, from separate FSS survey units containing discrete commodities with various levels of activation products and fission products. None of the samples containing Am-241 identified Np-237 above the detection limits. It should be noted that if Np-237 had been detected in any FSS sample, the survey unit dose contribution from the nuclide would have been included in the Sum of Fractions calculation for consideration relative to the release criterion. It should also be noted that it is not appropriate to use the term surrogate ratio in this context between the Np-237 and Am-241 since there is no equilibrium between the long-lived daughter (Np-237) and the parent (Am-241).
Also, a surrogate makes the assumption that the nuclide being surrogated is not easily measured, which is not the case since Np-237 is measured during every gamma analysis.