Proposed Tech Spec 15.5.4, Fuel Storage
ML20247D072
Person / Time
Site: Point Beach  
Issue date: 03/23/1989
From:
WISCONSIN ELECTRIC POWER CO.
To:
Shared Package
ML20247D057 List:
References
NUDOCS 8903300370
Download: ML20247D072 (1)


Text

___ _ _ _. - _ _ _

u t

15.5.4

' FUEL STORAGE Applicability-Applies to the capacity and storage arrays of new and spent fuel.

-Objective.

L

.To define those aspects of fuel storage relating to prevention of. criticality in fuel storage areas.

Specification l

1.

The new fuel storage and spent fuel pool structures are designed to withstand the anticipated earthquake loadings as Class I structures.

The spent fuel pool has a stainless steel liner to ensure against loss of water.

2.

The new-and spent fuel storage racks are designed so that it is impossible to store assemblies in other than the prescribed storage locations.

The l

fuel is stored vertically in an array with sufficient center-to-center distance between assemblies to assure K,f7<0.95 with the storage pool L

filled with unborated water and with the fuel loading in the assemblies limited to 44.8 grams of U-235 per axial centimeter of standard fuel assembly and 40.0 grams of U-235 per axial centimater of 0FA fuel assembly.

An inspection area shall allow ~ rotation of fuel assemblies for visual inspection, but shall not be used for storage.

3.

The spent fuel storage pool shall be filled with borated water at a concentration of at least 1800 ppm boron whenever there are spent fuel assemblies in the storage pool.

4.

Except for the two storage locations adjacent to the designated slot for 1

the spent fuel storage rack neutron absorbing material surveillance specimen irradiation, spent fuel assembly storage locations immediately adjacent to the spent fuel pool perimeter or divider walls shall not be occupied by fuel assemblies which have be.. subcritical for less than one year.

Unit 1 Amendment Unit 2 Amendment 15.5.4-1 8903300370 890323 PDR' AD

_=: - __[W_ _:__OCK 05000266

_ RDe.

_